You are on page 1of 10

DOTec Corp.

Design of Pile Cap Raft (ACI 350-06)

10.6.4.1 — In normal environmental exposure areas

β ≔ 1.2 γ ≔ 1.4 fy ≔ 60 ksi


⎛ 320 ⋅ ksi ⎞
fs.max ((s)) ≔ max ⎜24 ksi , ―――――― ⎟
⎜ ‾‾‾‾‾‾‾‾‾‾
⎛ s ⎞2 ⎟
⎜⎝ β ⋅ ⎜―― ⎟ + 25 ⎟
⎝ 1 in ⎠ ⎠

fs.max ((8 in )) = 28.267 ksi

fs.max ((9 in )) = 25.901 ksi

fs.max ((10 in )) = 24 ksi

ϕ ≔ 0.9

ϕ ⋅ fy
Sd ((s)) ≔ ――――
γ ⋅ fs.max ((s))

Sd ((8 in )) = 1.365 environmental durability factor

Sd ((9 in )) = 1.489 environmental durability factor

Sd ((10 in )) = 1.607 environmental durability factor

fc ≔ 4 ksi fy ≔ 60 ksi h ≔ 24 in

db ≔ h - 3 in - 1 in = 20 in

dt ≔ h - 2 in - 1 in = 21 in
DOTec Corp.

1) Design for one way shear


DOTec Corp.

b ≔ 30 ft 30ft design strips will be used for one way shear

Vu ≔ 585 kip

ϕVc ≔ 0.75 ⋅ 2 ‾‾‾‾‾


fc ⋅ psi ⋅ b ⋅ db = 683.052 kip

if ⎛⎝Vu ≤ ϕVc , “Safe” , “UNSAFE”⎞⎠ = “Safe”

2) Design for Punching


DOTec Corp.

2) Design for Punching

Punching shear will be checked using the Structural analysis program


DOTec Corp.

3) Design for Radial Flexure


DOTec Corp.

MuTop ≔ 282 kip ⋅ ft Negative moment at r =0

b ≔ 5 ft

Sd ((10 in )) ⋅ MuTop
Ku ≔ ―――――― = 205.539 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00394 As ≔ b ⋅ dt ⋅ ρ = 4.962 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 6.281 S ≔ ―= 9.552 in
⎝ 0.79 in ⎠ n

Use #8 @9" Top rebars at r = 0'

MuTop ≔ 240 kip ⋅ ft Negative moment at r =34'

Sd ((12 in )) ⋅ MuTop
Ku ≔ ―――――― = 174.927 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00333 As ≔ b ⋅ dt ⋅ ρ = 4.2 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.316 S ≔ ―= 11.286 in
⎝ 0.79 in ⎠ n

Use #8 @11" Top rebars at r = 34'

MuTop ≔ 211 kip ⋅ ft Negative moment at r =8.5', 17', 25.5

Sd ((12 in )) ⋅ MuTop
Ku ≔ ―――――― = 153.79 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00292 As ≔ b ⋅ dt ⋅ ρ = 3.679 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 4.656 S ≔ ―= 12.886 in
⎝ 0.79 in ⎠ n

Use #8 @12" Top rebars at r =8.5', 17', 25.5'


DOTec Corp.
DOTec Corp.

MuBot ≔ 270 kip ⋅ ft Positive moment

b ≔ 5 ft

Sd ((10 in )) ⋅ MuBot
Ku ≔ ―――――― = 216.964 psi
b ⋅ db 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00417
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

As ≔ b ⋅ db ⋅ ρ = 4.999 in 2

⎛ As ⎞
n ≔ max ⎜――― 2
⎟ = 6.328
⎝ 0.79 in ⎠

b
S ≔ ―= 9.482 in
n

Use #8 @9" Bottom rebars

5) Design for Circumferential Flexure


DOTec Corp.

5) Design for Circumferential Flexure

MuTop ≔ 266.7 kip ⋅ ft Negative moment

Sd ((11 in )) ⋅ MuTop
Ku ≔ ―――――― = 194.388 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ ⎜1 - 1 - ―――⎟ = 0.00372 As ≔ b ⋅ dt ⋅ ρ = 4.683 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.928 S ≔ ―= 10.121 in
⎝ 0.79 in ⎠ n

Use #8 @10" Top rebars


DOTec Corp.

MuTop ≔ 240 kip ⋅ ft Positive moment

Sd ((11 in )) ⋅ MuTop
Ku ≔ ―――――― = 174.927 psi
b ⋅ dt 2

0.85 ⋅ fc ⎛ ‾‾‾‾‾‾‾‾‾‾
Ku ⎞
ρ ≔ ――― ⋅ 1 - 1 - ―――⎟ = 0.00333
⎜ As ≔ b ⋅ dt ⋅ ρ = 4.2 in 2
fy ⎜⎝ 0.383 ⋅ fc ⎟⎠

⎛ As ⎞ b
n ≔ max ⎜――― 2
⎟ = 5.316 S ≔ ―= 11.286 in
⎝ 0.79 in ⎠ n

Use #8 @11" Bottom rebars