You are on page 1of 6

……….. pumps are used in M/E L/O system.

A) Actuator Pump and Camshaft Pump


B) Actuator Pump and Crosshead Pump
C) LO Pump and Crosshead Pump
D) Actuator Pump and LO Pump
E) LO Pump and Camshaft Pump

How much bar is the fuel oil pressure at M/E inlet?

A) 9.5
B) 7.5
C) 5.5
D) 3.5
E) 1.5

Excessive MDO must return back(or be directed to) ……… when M/E maneuvering is carried on by
MDO?

A) HFO settling tank


B) Vent(mixing) tank
C) MDO service tank
D) MDO settling tank
E) HFO service tank

M/E system must heated with ……

A) All
B) Auxilary LTFW Pump
C) No:1 or No2 HTFW Pump
D) NO:1 or No:2 LTFW Pump
E) Auxilary HTFW Pump

Which of the following is the function of Slowturn?

A) To turn engine to check that M/E pneumatic system is running properly


B) All
C) To turn main engine to check that there is any liquid in cylinder or not
D) To turn main engine with 5-7 rpm before starting with 30 bars pressurized air
E) To turn maing engine with 5-7 rpm to lubricate before starting with 30 bars pressurized air

Auxililary SW pump can not beused in sail because its ……… is not enough

A) Current
B) Flow rate
C) Pressure
D) Voltage
E) All

………….. room is defrosted when evaporator coils are frosted.

A) Vegetable
B) All
C) Meat
D) Lobby
E) Dry Provision

Which of the following occurs when Safematic Valve position doesn’t change to cross in Steering
Gear?

A) Hard over to Portside can’t apply


B) None
C) Both sides of the vanes can’t be used
D) Hard over to Starboard can’t apply
E) Hard over to Starboard and Portside can’t apply

M/E Aux. LTFW pump is used …………..

A) Only in sail
B) Only in port
C) As stant-by pump while No:1 LTFW pump is running
D) As stant-by pump while No:2 LTFW pump is running
E) None

HFO borularda boru ısıtma (steam tracing) sisteminin kullanılmasının nedeni aşağıdakilerden
hangisidir?

A) Yakıt sıcaklığı hızlı bir şeklide arttırmak için


B) HFO’da M/E durdurulursa yakıt sıcaklığı korumak için
C) Dizelden fuel oile geçişi sağlamak için
D) Akaryakıttan motorine geçişi sağlamak
E) Hiçbiri

High gravity tank in stern tube system is used in …….

A) In shallow water
B) Balasted ship
C) In deep Water
D) Fully loaded ship
E) All

Which of the following is opened firstly while preparing Steam Generating Plant(Boiler)?

A) Fuel solenoid valves


B) Fuel changeover valve
C) Air vent valve
D) Steam supply (stop) valve
E) None

Which of the following is the reason of installation of SW recirculation line shut off valve

A) None
B) To increase the temperature of sea water in cold seas
C) To decrease the temperature of LTFW
D) To decrease the temperature of sea water in hot seas
E) To increase the temperature of LTFW

Which of the following is not one of the factors that affects interface on conventional seperators?
A) Temperature
B) Disck Stack
C) Gravity Disc
D) Density
E) Viscosity

Which of the following is the function of the salinometer at Fresh Water Generator?

A) Measuring the salinity of sea water


B) Measuring the salinity of produced distilled water
C) Measuring the salinity of feed water
D) Measuring the salinity of vapor
E) Measuring the salinity jacket cooling water

Hfo in DB Bunker Tanks is kept at least …………..C*?

A) 145
B) 40
C) 115
D) 10
E) 85

HFO in Service Tanks is drained to ……..

A) Resdue tank
B) Feed tank
C) Bilge tank
D) Inspection tank
E) Sludge tank

Kurum üflemenin(hava veya buharla) kullanılmasının nedeni aşağıdakilerden hangisidir?

A) Petrol Yakıtlı Kazanda verimli yanma için yangın tüplerinin temizlenmesi


B) Petrol yakıtı kazanın yakıtını temizlemek için
C) Egzos kazanında verimli yanma için su borularının temizlenmesi
D) Yağlı kazanlarda verimli yanma için su borularının temizlenmesi
E) Egzos kazanında egzos gazı geri basıncını azaltmak için yangın tüplerini temizlenmesi

In HFO seperator, ………… is used to keep moisture the sludge.

A) Operating Water
B) Closing Water
C) Displacement Water
D) Conditioning Water
E) Opening Water

Which of the following is not the cause of boiler trip?

A) Low-Low level
B) High-high pressure
C) Flame out
D) Low-low pressure
E) High-high level

In which condition is high suction sea chest not used?

A) In deep water
B) Balasted ship
C) None
D) Half loaded ship
E) Fully loaded ship

Which of following valves is not used on steering gear?

A) Sea Water discharge valve


B) Directional control valve
C) Non return valve
D) Air vent valve
E) Safety valve

Which of following takes place when oil content in oily water is 25 ppm?

A) Overboard is closed, outlet to the bilge tank is opened


B) None
C) Overboard is opened, outlet to the bilge tank is opened
D) Overboard is closed, outlet to the bilge tank is closed
E) Overboard is opened, outlet to the bilge tank is closed

Which of following is the reason of using sootblowing (by air or steam)?

A) To clean water tubes for efficient combustion in Oil fired boiler


B) To clean Fire tubes for decreasing exhaust gas back pressure in Exhaust boiler
C) To clean water tubes for efficient combustion in Exhaust Boiler
D) To clean the fuel for Oil Fired Boiler
E) To clean fire tubes for efficient combustion in Oil Fired Boiler

Which of the following is/are false for fuel seperators?

I-Seal liquid; determines interface position,

II-High pressure operation water;ensures closing the bowl,

III-Low pressure operating water;ensures opening the bowl,

IV-Conditioning water;keeps the sludge moisturized

A. II-IV
B. I_II
C. II-III
D. I-IV
E. III-IV

Fuel oil Transfer Pump can suck only from ………

A) Spill oil tank


B) Residue Tank
C) Sludge tank
D) Inspection Tank
E) Feed Tank

D/G veya M/E’yi çalıştırmak için en az ne kadar basınçlı hava gereklidir?

A) 30 bar
B) 7.5 bar
C) 18 bar
D) 25 bar
E) 12 bar

How many bearings exist in Main Engine?

A) 14
B) 13
C) 6
D) 12
E) 7

Which of the following has not filter on D/G system?

A) S/W system
B) None
C) L/O system
D) F/W system
E) F/O system

Which of the following is not true for exchanger at Fresh Water Generator?

A) Sea water passes through tube pipes in vertical type heat exchanger
B) Generaly, jacket cooling water temperature is at 65-85 C which is used in heat exchangers
C) Heat exchangers are located at lower side of Fresh Water Generator
D) Heat exchanger are operated under approximately 0.30-0.40 bar vacuum
E) Jacket cooling water passes throught tube pipes in horizontal type heat exchanger

Scavenge in Stuffuing Box of M/E is drained to ……….

A) Inspection tank
B) Feed tank
C) Sludge tank
D) Residue Tank
E) Spill oil tank
Which sequence is correct in the boiler?

A) Burner air-Flame-Purge on-Burner oil-Igniter on


B) Burner air-Purge on-Burner oil- Ignıter on-Flame
C) Purge on-Burner oil-Burner air-Ignıter on-Flame
D) Burner air-Burner oil-Purge on-Igniter on-Flame
E) Burner air-Burner oil-Purge on-Flame-Igniter on

You might also like