0% found this document useful (0 votes)
243 views1 page

Fire Safety System Diagram

The document appears to be a building plan or schematic drawing. It includes notes about dimensions being in millimeters and elevations in meters. It also references other drawings for fire protection details, symbols, and abbreviations. The drawing shows various levels including a roof level at elevation +10 meters and another level at elevation +8.88 meters, and includes sprinkler and ventilation system details.

Uploaded by

omar esam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
243 views1 page

Fire Safety System Diagram

The document appears to be a building plan or schematic drawing. It includes notes about dimensions being in millimeters and elevations in meters. It also references other drawings for fire protection details, symbols, and abbreviations. The drawing shows various levels including a roof level at elevation +10 meters and another level at elevation +8.88 meters, and includes sprinkler and ventilation system details.

Uploaded by

omar esam
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Ir---......____________________ __________...______________________ _ - _ _ - - ______..

____ _ _ _ _ _ _ _ _ __ _ _ _ _ _ ----------------�
EL =+ 10.00 ROOF LEVEL N O T E S :
AAV TO SPRINKLERS I. ALL DIMENSIONS ARE IN MILLIMETERS & ELEVATIONS
' ARE IN METERS UNLESS OTHERWISE NOTED.
<I
0:
GV ... .., ....., ... .., ....., -- ....... >- �'�,
-
....., ....., ....... .......
\S)¥---EL+8.88M
\S1 lSl <FIELD VERIFY)
2. FOR FIRE PROTECTION GENERAL NOTES, SYMBOLS,
ABBREVIATION AND MISCELLANEOUS. DETAILS REFER
lSl lSl lSl TO DRAWING NO: RA-02054 l.001,RA-020542.001,
RA-020542.002,RA-020542.003, RA-020542.004 &
I
� � � �
I: - - •
N N
LL
1-
'1"0 4"0 4"0 ..;;.. 4"0 4"0 ;....,; 4"0 �"0 :::t;"0 """"'
4"0 ..;;..
4"0 ...._ �"0 �"0 �·;0 2"0 1 1/.,"0
3"0 .:a..: RA-020542.005 RESPECTIVELY. 0
EL+ 8.55M (FIELD VERIFY I------Ff!'---l►;;;;_---:::'."T" IS,:,.,
'--'-..;;..,1a �\S1_!+�\S1"r \S1� , ""-'.....i,�\S14"'"":\S1:'f �...:...�\S1"T'�\S1::t-�\S1� ::::\S1f-'�_\S1:i, 3 . ALL PRESSURE,FLOW AND SUPER�SORY SWITCHES SHALL
;....,;


BE CONNECTED TO BUILDING FIRE ALARM SYSTEM.
\Sl

-- ....... ,.--
\Sl

--
..- 3 "0 \ -;!:_ "' -;!:_ - -;!:_ -;!:_ -;!:_ - - - z
lSl
?"0

I
....., ....... ... ..,
l
..."_
- - ... .., ....., ....., ....... 4. PROVIDED PIPE ELEVATIONS ARE INDICATIVE ONLY,
SHALL BE FIELD VERIFIED.
ILi
VI
z
0
�lSl • u
'
v
I ½ TO SPRINKLERS TO SPRINKLERS
TO SPRINKLERS,\ z
TO FIRE ALARM SYSTEM • lSl ILi LEGEND
1-------------------------1�
,--'--"
..- t-•----r--t' TO
lSl l
_ 3"0 "-
SPRINKLERS
OS & Y GATE VALVE
>-
0:
-
"' 2"0 \ lSl WITAMPER SWITCH

lSl l N
w
"' I
2"0 l><1 GATE VALVE �
TO SPRINKLERS\
l lSl �
"' \S1 ALARM CHECK ::J

I\
0
I lSl VALVE

�-
N
I
"'

...
6"0 6"0
TO SPRINKLERS �

i--1=�----... ---,
I
I
�- DRAIN VALVE
C)
z
':!:.
t
� TEST VALVE i
i • <I
lSl lSl lSl lSl ---...---,2"0 0:

�- i
\S1

X
C
FIRE DEPARTMENT CONNECTION
I I
2"0 2"0
-
I
VI
I
r----------.---- ---------------�-----------------� - -- -- -
1
I
.......,-- TO SPRINKLERS
'' '' CHECK VALVE
I
>-
----,
I I I
I
'' '' ::!ii
'' ''
I
0
I
I
FHC FHC FHC 0:
'� 2" FLUSH CONNECTION DRAIN LINE
I
I '� LL
I
- ---------------
- - - - -
-- -
------------ � - - -
-WITH GATE VALVE EL=+5.00 - FIRST FLOOR LEVEL C
I

ILi
TO SPRINKLERS
' , ABOVE GROUND FIRE WATER LINE

z

( i ID
--~ ,..lSl """"° ,.lSl ..., -lSl
� -- ... ..,-_ ... ..,-_ ....., 0
\S1 lSl IS) WATER FLOW DIRECTION
r-

= lSl lSl lSl w


� - =- =- :... :... N :... :_ - ID
4"0 4"0 4"0 4"0 4...:. 0 3"0 3"0 3"0 3"0 3"0 3"0 3"0 2"0 1 1/,"0
"0 4"0 3".lil:.l
_J
�Nri��Nr�� :r-:T'�':L---EL+ 3 6M ,FrELD vERIFY>
r--;;i..ll;�►-��;-t-;;�����"';�� r � r "'""":�:r-:_:-t'-:�'-;\Sl .a FLOW SWITCH ..J
\Sl �
�_ - \Sll - \Sl \Sl <I
..- -;!:_ -;!:_ - - ::::_: ::::_: - - :c
&1-•....a1..:...--r: �l-1\ ... .., ....., ...........,) ,. ..., --- ,. ..., --- ,. ..., PRESSURE GAUGE
3"0 ) � � -0::-
VI


..- 2"0 ) :
,
V
TO SPRINKLERS
V
TO SPRINKLERS PRESSURE SWITCH 0:
2"0
-----------------------------► ---------------------------------1 ,c(
EL+ 3.56M (FIELD VERJFYl---� el,-...,...;;--/\ L-------------------
a.
lSl
..- 3"0 ) � TAMPER SWITCH z
0::
TO FIRE ALARM SYSTEM SIGHT GLASS 0

_J
AU TOMATIC AIR VENT _J
::J
LL

rsi
2"0

i1
z
FIRE HOSE CABINET
'

lSl

6"0 I\ � 6"0 "'


lSl N
::J
C
0
I

0:
I

i--I=�---_..,. _ --, a.

t
lSl w
i 0:

' ' ______________________


TO SPRINKLERS 0
,__ z
-
I I A
2"0
- 1 _,
I

....... .......
I
r---�-----------------�
( - REFERENCE DRAMNGS ci
1-,D,_W--,G-. --, - TRc-0L- - F 0R J- .-,-0.- I _,-0-0
- ,-8,-6,-4,..,3,----,
0007 ----,-RD _020500----1 �
I --, "'=- =-,...,,-- --,---,-"' ,,..,,---,-,--,--=-cc
lSl lSl lSl CON
\S
"'
&'
- I
I
4"
=- � I =- FIRE PRO. GEN. NOTES,LEG., & ABBREVIATION RA-020541.001 �
-
:_ I
3"0
FIRE PRO. MISC. DETAILS RA-020542.001-005 <I
I I

2"0 \S1 \S1


I I
---------- ◄--- RA-020544.00 o
I
FPS SPRINKLER LAYOUT-GROUND FLOOR
I
-----'
::J
I I
lSl FPS SPRINKLER LAYOUT-FIRST FLOOR RA-020546.00 <I
I
0
....... ....... .......
I

1" ►----------,
1 N N
I I I

RA-020547.00 VI
L----------------------
FPS SPRINKLER LAYOUT-ROOF
I
I

'
N I
I

1ENLARGRD FIRE WATER LAYOUT- !SF AREA RA-020607.00 LL


I

__ _ ) TO FIRE ALARM
I

------------------+--------IO
I
I
( SYSTEM &•
I
I
V')
0::

I
w
' I
'
'' N
' _J �
0:
'
N,
I -0::
""
z 0:
ILi
a.
I a_ 0
I V') 0:

'
I
a.
6"0

JACOBS ZATE ®
0
..... , >-
ILi
_J
0
VI
I
I
I
w
I I

:c
I
I
I
&'
I '

'

I I
I I
' I
I

�--------- ►◄ ILi
I

I 0:
lSl <I
I

&•
u _,, -w
' I
,N1
I
z
____ .J
RELIEF VALVE TEST VALVE IN READILY 0:
(PRESSURE SETTING _._,._,i:_::,SIBLE LOCATION ILi
I75PSI> C+5FT FFLl I

FHC
- FHC
- FHC FHC
SCALE: NTS.
C
w
z
TI11--- --
-#'---/I TO FIRE ALARM 1-------------------------1�
1-'.-:'-1 ,, ( SYSTEM �
_.. ....
__ L
I
-
- -. 1-------------------------1z
REVISION VAL IDATION
.,....,... ..... ,' 0
'' u
/ THIS REVISION NO. 121121 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION

X X
/

'
/ REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
I '
\
10-08643-0007-002 z
1----------=--=====;====:==:======------.-------IO
' \
6"0 (150mm)
I I \
I
I \
DESIGtl CERTIFICATIOtl REVIEW FOR KEY DRAWltlGS OTHER -
FIRE DEPARTMENT
I \
I l-
1"0 INSPECTOR TEST CONNECTION
(DESIGN AGENCYI O REQUIRED ISAUOI ARAMCO)
<I
I
I I
CONNECTION 2 NOS
1 1-- - �- - - -
- -+-- - - - �- - - - t--- - -
--<
:::,
: \ I I
,
E N G G ./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
,' PIPE FOR DETAIL REFER TO DWG.
I
', 0::

OF 65MM INLET '
I I
' KSK
1---0-3/�30_ 1_ 2 ,_ __0,_
MAR KXD
_ 1 _,0_12_ ,_.___0_,1_ , 0_ 1_2 3_ ___c__
AAK
0,_1 ,_ 0_12_ ,_.__ ___--I Q
'-"
0 I I
\ / RA-020542.002.002 AND SEE DETAIL-8
u
I I

DISCHARGE TO :
I
\ ',
'' ''
I '''
I
'''
I
REV.NO. DATE REVISION DESCRJPTION LL.
z
''
\
00 03/30/23 ISSUED FOR CONSTRUCTION
ATMOSPHERE i ''
'
\

V') :::, 45 ° ELBow-�',c",, '\)// '


�,-------- >-5 ------ __,...
JOB ORDER/EWO NO. LLI
TO BE USED FOR
':.;;,._,________'�__c,,-___;;2" FL LISH CONNECTION
0 , ..... _
10-0864 3-0007
THIS REVISION IS NOT
:C
1------------�-------------1�
aJ I W CONSTRUCTION UNTIL CERTIFIED AND DATED
>- _J
WITH GATE VALVE SAUDI ARABIAN OIL COMPANY o
EL=+0.00 -
0-
GROUND LEVEL
FPS RISER DIAGRAM "f'p�f' �
ADMINISTRATION BUILDING •5500
1--------------------------< �
i
I ZULUF AH ISF <1
6"0 PIPE FOR CONT. 1 6"0 (150mm) FW LINE 1-------------------------1 0:
REFER TO ENLARGED I FPS RISER DIAGRAM SAF ANIY A SAUDI ARABIA o
FIRE WATER LAYOUT � I SCALE NTS. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO. 1,/)

A88 B RA-020548 001 00 �


SH
DWG NO: RA-020607.001
...(..,

�I
Saudi Aramco 2615 ENG. (05/05)
R_ES
_T_R_ICT--B-D�I I VECTORI CADD-05