You are on page 1of 7
Manufactured and designed by Pariner for iwa i Energy Technology and Control Ltd. Located at | Sussex, United Kingdom | FUNCTIONAL SAFETY CERTIFICATE Kiwa Gastec Certification hereby declares that the | Integrated Burner Controller, series ETC60xx and the associated components as detailed in the appendices to this certificate are suitable for inclusion in a $.LL.3 loop. The compliance is based on an evaluation to EN 61508 (2001). Report number 1128836 ‘The systems and their associated components only comply with the above listed safoty requirements if the specifications and instructions as detailed in the commissioning manual are met. ‘The FTC60xx series Integrated Burner Controller provides fully integrated bumer control systems for industrial burners, providing a PID function to control the pressure /temperature of the boiler by modulating the fire rate, full burner ‘management functions including flame/air pressure monitoring and a fuel shut- off valve control. They can be complemented with various boiler sensors, servo motors, display boards, oxygen probe interface and daughter boards. ‘Where a safety limit function or gas valve proving function is mandatory for the application, the system shall be included with respectively an ETC fail safe temperature sensor or pressure sensor. Gastec ‘Kiwa Gastee Certification Wilmersdort 50 P.O. Box 157 7300 AC APELDOORN ‘The Netherlands Tel 631 $5 5393355 srw thiwa.com -Eivision Director. ee : kiwa [sed . Partner for progress 0063 Pago 1 of 4 ‘Appendix no. 1 Dated: December 2008 Examination report(s): 123836 dated November 2008 FUNCTIONAL SAFETY CERTIFICATE: E 1855 FS1 to FS4 Integrated Burner Controller, series ETCBOxx. List ofall avaiable tyees: firing algorithm when fr agen. | Oi. ‘As &TC6000 but operates as a single fuel Gas unit oniy. | As ETC000 but operates as silo fuel Ol union. Basic specification control. ‘As ETC6010 bul operates asa staged fring algorthm when fring on Ol. ‘As ETC5010 bul operates as a sinde fuel Gas unit on ‘As ETC6010 but operates_as a since fuel Oil unit only. List of approved combinations: Model: ‘Characteristics: ETC1021 Gas Pressure Sensor 600mBar_ ETC1030__| Steam Pressure Sensor 25Bar . [eretoa4 Pressure Sensor (Gas or Sleam) “Bar = ETCto40 Boiler Temperature Sensor 0= 150 ‘Temperature Sensor 0 — 400C "Daughter Board (comms only) ETC6051 Daughter Board (comms + 4-20mA) "ETCe052 Daughter Beard Comma? {verter interface) £T08087 | Daughter Board (comms + one VSO + one VG channel) = ETC6058 | Daughter Board (Qual Scanner + comms + 4-20mA) —_ ETC6059 Daher Boacs (Dual Sanne + comm + inveterate] erco0e0 isplay Unit12 key (Basic Function} TCB06 | Display Unit12 key (Including Relays @ RTC) ET C6070 ‘Display Unit9 key (Basic Function) ‘ETC6071___| Display Unit.9 key (Including Relays & RTC) ETCO7S 410.4" Touch Screen Display ‘ETC8O76 5.7” Touch Soreen Distiay ETC8080 | Oxyaen Probe In —— ETC6086 “Temp Sensor 06222 Ce 0063 Number E 1855 Gastec Certification B.V., hereby declares that the Integrated Burner Controller, series ETC60xx designed and made by Energy Technology and Control Ltd. in Sussex, United Kingdom complies with the essential requirements of the Gas Appliances Directive (90/396/EEC). The compliance is based on examination to: EN 298 (September 2003) EN 12067-2 (March 2004) EN 1643 (October 2000) PIN :0063BR1587 Report number 7 see appendix to certificate The products have been approved for all EU and EFTA countries. A description of the specific types is given in the appendix to this certificate. a "SastTec Apeldoorn, 27 Jul * pekioom, 27 sue Certification sot w Ir. yr. van Rij, Director. a NN eas wat ALVOlseILYAO File Issue: 004 HEADING SHEETS ne tee a. Report Number: 122587/1 Automatic burner control systems ago: HS 200 Responsible Test House: GASTEC Certfication BV Address: Wilmersdorf 50 7327 AC Apeldoorn P.O. Box 137 7300 AC Apeldoorn ‘The Netheriands Telephone: +31 555 393 393 Facsimile: +31 555 393 3901676 Name of the Applicant: Energy Technology and Control Ltd. Address: 25 North Street BN7 2PE, Lewes East Sussex United Kingdom Name of the Manufacturer: Energy Technology and Control Ltd. Address: 25 North Street BN7 2PE, Lewes East Sussex United Kingdom Test report of the examination of the modification and or extension to the: ‘Automatic burner control systems Series ETC60xx and ETC61xx Tested and examined to: EN 298 ‘Automatic gas burner control systems for gas burers and gas burning appliances with or without fans (September 2003) EN 12067-2 _Gas/air ratio contro's for gas burners and gas buming appliances, part 2: Electronic types (March 2004), EN 1643 Valve proving systems for automatic shut-off valves for gas bumers and gas appliances (October 2000). EN 230 Automatic burner control systems for oll burners (June 2006). EN 298 ‘Automatic gas burner control systems for gas burners and gas burning appliances with or without fans (September 2003), This report should be used in conjunction with report(s) no: 122587 Te tenn tor mesa fists . Partner for progress 0063 Page 2 of 12 EC TYPE-EXAMINATION CERTIFICATE: E 1855 Appendix no. 4 Dated: July 2007 P.LIN.: O063BR1887 Examination report(s): 122587/1 dated July 2007 ‘This appendix supersedes appendix no. 1 dated July 2006. Integrated Burner Controller, series ETC60xx (PLN. 00638R1587). aileble Model: ‘Characteristics: - ETC6000 Standard control, ETC6002 ‘As ETC6000 but operates as a staged firing algorithm when firing on Oil ETC6003 ‘As ETC6000 but operates as.a singe fuel Gas unit only. ETC6004 ‘As ETC6000 but ozerates as a sins fuel Oil unit oni ETC6006 Basi specification contro. ETC6010 Standard contro, ETC6012 ‘As ETGB010 but operates as ETC6013 [ETC6o14 but operates as a single fuel Oil unt only List of approved combinations: Model ‘Characteristics: eTC1021 Gas Pressure Sensor 600mBar a a ETC1030 ‘Steam Pressure Sensor 25Bar ETC1034 Pressure Sensor (Gas or Steam) 48a ETC1040 Boller Temperature Sensor 0 ~ 150°C ETCt0da Boller Temperature Sensor 0 ~ 400 ETC2012 Oxygen Probe - ‘Servo Interface Servo 4Nm —PServe AEN ‘Servo 20Nm ‘Servo 40Nm 027 | Servo 10Nm ETC0028 ‘Servo 20Nm = = ETC6032 ‘Servo 20Nm ETC6033 ‘Servo 50Nm ETC6040 ‘Servo Stepper 1.5Nm [eTC6050 ‘Daughter Board (comms only) [eTC6051 Daughter Board (comms + 4-20mA) [Erce9s2 Daughter Board (comms + inverter interface) ETC6057 ‘Daughter Board (comms + one VSD + one {iO channel) ETC6058 Daushiter Board (Dual Sean 4-20mA ETC6059 Daughter Board (Dual Scanner + comms + inverter interface) | eTC6060 Display Uni 12 key (Basic Function) ETC6061 | Display Unit, 12 key 765002 | Display Unit 12 key incusina Relays. RTC, Data Loosing) |[erc6070 Display Unit key (Basic Function) ‘C6071 | Display Unit.9 key (Including Relays & RTC) ETC6072 Display Unit @ key (Including Relays, RTC, Data Logging) [eTceo7s Touch Screen Display ETC6076 "Touch Screen Display —s: LETCB080 Oxsen Probe interface: . ETC6OBE Temp J 06223 Number E 1855 ( € 0063 Gastec Certification B.V., hereby declares that the Fuel Air Ratio Control, series ETC61xx designed and made by Energy Technology and Control Ltd. in Sussex, United Kingdom complies with the essential requirements of the Gas Appliances Directive (90/396/EEC). The compliance is based on examination to: EN 12067-2 (March 2004) PIN :0063BR1587 Report number : $6e appendix to certificate The products have been approved for all EU and EFTA countries. A description of the specific types is given in the appendix to this certificate. Apeldoom, 27 July 2 TSastTec i Ir. MJa0. van Rij, Director. "aan mat JALVOIsILYSAO TOV Rheinland Immissionsschutz und Energiesysteme GmbH A TUVRheinland® Genau. Richtig. Prafstelle far energietechnische Einrichtungen Typpriifung nach TRD 411:02.97 und TRD 412:06.98 an GAS-/OL-Brennersteuerung mit Brennstoff-Luft- Verbundregelung und Dichtheitskontrollsystem Hersteller / Auftraggeber: Produkt: Typbezeichnung, Technische Daten: Geraitebeschreibung: Prifaniass: Priffergebnis Bemerkung: KOln, 30.07.2007 432/schu Bearbeiter (futh Dip|4ng. O. Schulte Auttrag Ne-21207786 Energy Technology and Control LTD 25 North Street Lewes, East Sussex BN7 2PE (UK) Kombinierte Gas-/Olfeuerungssteuerung mit Luftverbund- regelung System: ETC 60xx ETC 61xx siehe unter 2, ‘System ETC 60xx Die Gerdte werden zur fehlersicheren Steuerung von Ol- und Gasbrennemn eingesetzt und erméglichen eine siche- re Brennstoff-Luft-Verbundsteuerung sowie Dichtheitskon- trolle der Absperreinrichtungen ETC 61xx: Das Gerét ist zur sicheren Steuerung des Brennstoff-Luft- Verhaittnisses vorgesehen und bildet eine Teilmenge der vorgenannten Gerate. Der Prifling hailt die Anforderungen der oben genannten Prufrichtlinien/Normen ein Prifstelle for energietechnische Einrichtungen DIN- und DVGW-Prifstelle Stlv. Leiter der Prafstelle | Px Dipl ot dee Ruckwart Seite 214 Bericht Nr. $282 2007 T1

You might also like