You are on page 1of 8
Mussaffiah Otice Abu Dhabi - U.A.E @ Abu Dhabi A.E Fax : (971 2) 6674966 a Fax : (971 2) 5511590 aes tana il ec sal: stargatoencom e re Arabian Bureau of Services . 7 Certificate No: AD/10034/23 JA. Date of Certificate: 02/08/2023 The equipment detailed below was examined in accordance with UAE Law Decree 32 of 1982 Article 20, ADNOC Group Standard “HSE-OS-ST19” and Ref .Std : BS EN 361 :2002. ‘AMB HERTEL Owner P.O. Box: 113955, Abu Dhabi, UAE Equipment Name Safety Harness Location of Inspection Ruwais ‘Type of inspection | Thorough Examination | Date of Last Inspection 1170272023, Date ofLastNDT | N/A Date of Last Proof Load Test | N/A Summary: The following “Safety Harness" have been Thorough Examined Function tested and found to be suitable for further service with recommendations as given hereunder Serial No. Description S.W.L, | Recommendations SAFETY HARNESS 220025/0677/1235 220025/0972/1271 [Full body safety harness X c/w double 220025/0936/1608 lanyard 1.8mtr & Shock Absorber 100kg | Found Satisfactory 220025/0148/1637 and Safe to use 220025/0436/1387 [Make : STABLL. 220025/0088)1456 220025/0083/1915 220025/0090/1313 220025/0963/1339 220025/0326/1332 ‘THOROUGH EXAMINATION REVIEW: 1 is he ist examination ar instalation or assembly aa new site or aes AOL Tete answer (oe above questions YES, haste euipmen Been stale | yg NO ‘Was the examination | Examination | Exceptional carideut | 6Momts | ¥ [renomas] | PSR |v | en Identification of any part found to have a defect which is or could become danger to persons and description of | the defect: (if none state NONE) NONE Ts the above defects which isnot yet but of Nor Ind igo posn? Lnseticane | ¥ [vs [v0 (IFYES state the date by when) YESBy: a Particulars oF any repair, renewal o alteration required to remedy the Gees? | ony identified above: Particulars of any tests carried out as part oF the examination: it deusatte NONE ‘Thorough Examination 1S THIS EQUIPMENT SAFE TO OPERATE? ves| ¥ [No | Colour Code: BLUE 1 conify on behalf of the Third-Party Company named above that the Wiens described herein were Thoroughly Examined by myself being a Competent Person and were found at the time of inspection free from cracks, flaws, or ‘other defects, unless otherwise stated above and considered to be Safe for Further Use, subject to contimions maintenancabeing applied and qualified operator/user being employed ; 31/01/2024, Next Proof Load Test Duc.on: Not Applisatgy Jas Boris Becker Leodhas LS Services Attban Bees Of Serviced EF idity of Certificate: 6 months from the date of Inspection Form ABOS RC 008 Rev.07 BRINILABNLITY FOR THE ENGINEERING WORLD FULL MEMBER OF LIFTING EQUIPMENT ENGINEERS ASSOCIATION (LEE Certificate No: AD/10034/23 JA Satisfactory No, Safety Harness CHECK LIST Touney Remarks [Cook for frayed edges, Broken fibers, pulled sitehes, euts, burs] ——— 1 fond chemical damage vel [me] [val [D-Rings/Back Pads — Check D-rings for distortion, cracks, breaks) ——— 2 Jand rough or sharp edges, vel [x] [ral [Aftachment of Buckles — Inspect for any unusual wear, Fayed o 3 [cut fibers, or broken stitching of the buekle or D-ring attachments |[Y=]¥ |] _ [4] [Trongue/Grommets Inspect for loose, distorted or broker 4 grommets. Webbing should not have additional punched holes| [Ve] [Ne] [Nal ¥] [The outer bars and center bars must be straight FTongue Buckles — Buckle tongues should be five of distortion inl -——— 5. shape and motion Yel Tee] [eal [Friction and Mating Buckles — Inspect the buckle for distortion| 6 inspect buckle frame and sliding bar for cracks, distortion, of [¥e]_[8e] [Na] ¥] harp edges 7 [Quiek-Connect Buckles — Inspect the buckle for distortion ee] ‘Any Other Comments! fecommendations: signature: |). / Date: 0108/2028 Key: Satisfacto Yes: Suitable for Service No: Not Suitable for Service or Repair Required NIA: Not Applicable ‘This certificate will be null and void Tor any reason the Timitations and conditions set forth herein have been exeeeded an ‘or not adhered to. Tis certificate remains valid forthe period stated as long as no modifications, alterations and/or repairs done ‘with inthe said period from the date of inspection. The inspeetion results are relating exclusively forthe equipment inspection caried out. The inspection certfiate/eport shall ‘not be reproduced except in fall without the approval of te inspection body andthe elient, LIABILITY ‘The Client or his assignee or successor in interest aares to indemnify and hold harmless Arabian Bureau of Services ftom and aginst any and alleaims, demands, lawsuits or actions for damages, including legal fes to person andor propery tangible, intangible or okerwise which ‘ay be brought agsinst Arabian Bureau of Services incidental to arising eut of er in connection with the work t be done, services to be Detformed or material tobe Tumished hereunder excep for those claims caused solely and completely bythe nepligence of Arabian Bureau of Services. its directors officers, employees, agents or sub-soniractos Under no circumstances whatsoever shall Arabian Buren of Services be lable or any injury or damage any person or property oecuring by reason ofany defect inte design, materials, machinery, equipment or ober tems whichis he responsibility of Arabian Bureau of Services to Inspect under the terms specifi hereunder. Nothing heten contained shal be deemed to relieve any see or manufacturer ofits warants expresso implied Inthe event Arabian Bureau of Services i proven negligent in any respect, the Habit of Arabian Bureau of Services, ts agents, employees and subcontractors, for Proprietor’ ciaims shall ot exceed he rete of US, $1,000 the total compensation paid to Arabian Bureau of Serves forthe wor. Proprietor shall ave, delend and hold Arabian Bureau of Services harmless against clams in excess of US. § 1,000 the ‘otal compensation pid te Arabian Bureau of Sevies for the work. Form ABOS RC 008 Rev.03 on 01/11/2021 Page 2 of 2 Head C P.O.Box : 47133 Abu DI Tel. : ( Fax : ( E-mail Web Mussaffah Office P.O.Box : 47133 Abu Dhabi - U.A-F Tel. : (971 2) 3511520 Fax : (971 2) 3511590 Dive Abu Dhabi abi - U.A.E 971 2) 6674166 971 2) 6674966 nea tesa gaps ass nal cages ‘i a ‘Arabian Bureau of Services aus [sobNo: __|_onoi372 Date of Inspection: 01/08/2023, ‘The equipment detailed below was examined in accordance with UAE Law Decree 32 of 1982 Article 20, ADNOC (Group Standard " HSE-OS-ST19” and Ref Std : BS EN 361 :2002, AMBHERTEL Ovmer P.O. Box: 113955, Abu Dhabi, UAE Equipment Name Safety Harness Location of Inspection [Ruwais Type of Inspection | Thorough Examination | Date of Last Inspection 11/02/2023 Date ofLastNDT | N/A Date of Last Proof Load Test_| N/A ‘Summary: The following “Safety Harness” have been Thorough Examined Function tested and found to be suitable for further service with recommendations as given hereunder Serial No. Description S.W.L. [Recommendations SAFETY HARNESS 220025/0685/1487 220025/0687/1333 |Full body safety harness X c/w double 220025/0370/1143 lanyard 1.8mtr & Shock Absorber 100kg | Found Satisfactory 220025/0700/1619 and Safe to use 220025/0456/1178 [Make : STABLL. 220025/0414/1193, 220025/6983/1833, 220025/0448/1151 220025/0374/1249 220025/0369/1917 THOROUGH EXAMINATION REVIEW: Is this the first examination after installation or assembly at a new site or ES no |v location? If the answer to the above question is YES, has the equipment been installed YES NO correctly? | Was the examination Examination Exceptional | carried out? othe! a ee Scheme | | Circumstances Identification of any part found to have a defect which is or could become danger to persons and description of | the defect: (if none state NONE) NONE Is the above defects which is not yet but of ‘NOT immediate danger to persons? appuicapie | Y | YES Ean: (FYES state the date by when) YES By: Particulars of any repair, renewal or alteration required to remedy the defect HONE, identified above: — Particulars of any tests carried out as part of the examination: "i | Gone state NONE) ‘Thorough Examination IS THIS EQUIPMENT SAFE TO OPERATE? yes | ¥ | No Colour Code: BLUE T certify on behalf of the Third-Party Company named above that the items described herein were Thoroughly Examined by myself being a Competemt Person and were found at the time of inspection free from cracks, flaws, or other defects, unless otherwise stated above and considered to be Safe for Further Use, subject to continuous ‘maintenange being applied and qualified operator/user being employed 2 31/01/2024 Validity of Certificate: 6 months from the date of Inspection Form ABOS RC 008 Rev.03 TAIA/ABWN LITY FOR THE ENGINEERING WORLD FULL MEMBER OF LIFTING EQUIPMENT ENGINEERS ASSOCIATION (LEEA) - UK Certificate No: AD/10035/23 JA ‘Satisfactory No. Safety Hamess CHECK LIST vader Remarks [Look for Fayed edges, broken fibers, pulled stitches, cuts, barns) —— 1 fend chemical damage rely [ee] [val ID-Rings/Back Pads — Check D-rings for distortion, cracks, breaks 2 vel [se [_1sal ind rough or sharp edges ‘tachment of Buckles — Inspect for any unusual wear, frayed > 3 |eut fibers, or broken stitching ofthe buckle or D-ring attachments ||] [+] [4] [Tongue/Grommets Inspect for loose, distorted or broken] 4 lbrommets. Webbing should not have additional punched holes| [Ye] [s+] _|a] ¥] [The outer bars and center bars must be straight. [Tongue Buckles — Buckle tongues should be free of distortion io 7 5 Lape and motion, velY [ss] [4l Tietion and Mating Buckles — Inspect the buckle for distortion : 6 Inspect buckle frame and sliding bar for cracks, distortion, of [Ye] [+] [a] ¥] harp edges 7 _(Quiek-Connect Buckles — Inspect the buckle for distortion. sl a] ‘Any Other Comments/ Recommendations: Signature: Date: 0108/2023 Key: Satisfactory! Yes: Stitable for Service No: Not Suitabie for Service or Repair Required INIA: Not Applicable ‘This certificate will be null and void if for any reason the limitations and conditions set Tor herein Rave been exceeded and! or not adhered to. Tis certificate remains valid forthe period stated as long as no modifications, alterations and/or repairs done ‘with inthe aid period from the date af inspection, The inspection results are relating exclusively forthe equipment inspection carried out. The inspection eertifcatereport shall not be reproduced except in fall without the approval of the inspection body andthe elit. LIABILITY “The Client or his assignee or successor in interest agrees indemnify and ho harmless Arabian Bureau of Services fom and agains any and all claims, demands, lawsuits or ations for damages including legal fees to person and/or propety tangible, intangible or otherwise which may be brought against Arabian Bureau of Services incidental. aising out of or in coanection withthe work toe done, services to be perfoemed o material wo be furnished hereunder except for these claims caused solely and completely by the negligence of Arabian Bureau of Serves, is iectors, offices, employees, agents or sub-contractrs. Under no circumstances whatsoever shall Arabian Butea of Services be Hable foray injury or damage t any person o property occuring by reason of any defect i the design, materials, machinery, equipment or othe tems which isthe esponsibility of Arabian Bureau of Serves to inspect under the terms specified hereunder” Nahing herein contained shall be deemed to relieve any seller or manufacturer of ts warrants, expres implied Inthe event Arabian Bureau of Services is proven negligent in any respect, the ibility of Arabian Bureau of Services, its agents, employees and subconracors, for Proprieto' clans shall ot exceed the rete of (#U.S.$ |,000#) the total compensation paid wo Arabian Bursou of Services for the work. Proprietor shall sve, defend and hold Arabian Burea of Srviees harmless against cai in exoess oF US. § 1,000 the total compensation paid te Arabian Bureau of Services for he work Form ABOS RC 008 Rev.03 on 01/11/2021 Page 2 of 2 Head Office Abu Dhabi i Mussaffiah Orie P.O.Box : 47133 AN P.O,Box : 47133 Abu Dhabi - U.A.E j Abu Dhabi - U.A. Tel. : (971 2) 6674166 Tel, : (971 2) 551 Fax : (971 2) 6674966 a Fan : (971 2) 551159 E-mail : abosad@eim.a I: abos@abosad.com Web : www.abosad.com Pe Web : www.abosad.com Arabian Bureau of Services MINISTRY OF LABOUR APPROVED CRANE & LIFTING EQUIPMENT INSPECTION ENGINEERS Job No: OR 01372 Date of Inspection: 01/08/2023 Certificate No:__| _AD/10036/23. A. Date of Certificate: 02/08/2023 The equipment detailed below was examined in accordance with UAE Law Decree 32 of 1982 Article 20, ADNOC Group Standard “HSE-OS-ST19” and Ref .Std : BS EN 361 :2002, ‘AMB HERTEL, Owner P.O. Box: 113955, Abu Dhabi, UAE Equipment Name Safety Harness Location of Inspection Ruwai Type of inspection | Thorough Examination | Date of Last Inspection 11/02/2023 Date of Last NDT | N/A Date of Last Proof Load Test NA ‘Summary: The following “Safety Harness” have been Thorough Examined Function tested and found to be suitable for Surtver service with recommendations as given hereunder. Serial No, Description S.W.L._[_ Recommendations SAFETY HARNESS 220025/0180/1342 220025/0392/1312 |Full body safety harness X e/w double 220025/0230/1203 lanyard 1.8mtr & Shock Absorber 100kg | Found Satisfactory 220025/0955/1032 and Safe to use 220025/0085/1358 Make : STABLL, 220025/0100/1521 220025/0953/1147 220025/0234/1246 220025/0347/1034 220025/0232/1354 ‘THOROUGH EXAMINATION REVIEW: 1s this te frst examination affer installation or assembly at a new site or ves wo 17 location? acre aee the above question is VES, has the equipment been installed | ye WO ‘Was the examination ] Examination Exceptional carried out? S Monti | | 1a Monts Scheme | ¥ | circumstances Identification oF any part found to have a defect which is or could become danger to persons and description of the defect: (if none state NONE) NONE sf Is the above defects which is not yet but of NOT ] immediate danger to persons? appuicasie | | YES Poe (IEVES state the date by when) YESBy: Particulars of any repair, renewal or alteration required to remedy the defect identified above: ne Particulars of any fests eartied out as part ofthe examination: ooo (fnose state NONE) ‘Thorough Examination 1S THIS EQUIPMENT SAFE TO OPERATE? yes | ¥ | No "Colour Code: BLUE 1 certify on behalf of the Third-Party Company named above that the items described herein were Thoroughly Examined by myself being a Competent Person and were found at the time of inspection feee from cracks, flaws, or other defects, unless otherwise stated above and considered to be Safe for Further Use, subject 4g_continuous ‘maintenancg being applied and qualified operator'user being employed 310172024 NextProofLoad Test Due on: Not App} Reviewed Authorized By:h Boris Becker Leodhas OF Services Arabian Bureau Of Services alidity of Certificate: 6 months from the date of Inspection Form ABOS F008 Rev.03 ERUIMAARBIALITY FOR THE ENGINEERING WORLD Page Lot? FULL MEMBER OF LIFTING EQUIPMENT ENGINEERS ASSOCIATION (LEEA) - UK Certificate No: AD/10036/23 JA Satisfactory No. Safety Harness CHECK LIST (eine Remarks ICook for Fayed edges, broken fibers, pulled sitches, cus, burn ind chemical damage [D-Rings/Back Pads ~ Check D-rings for distortion, cracks, break — 2 fond roush or sharp edges re [Artachment of Buckles ~ Inspect for any unusual wear, frayed 3. [cut fiers, or broken stitching ofthe buckle or D-ring attachments [=] ve] [se] [al 7 Ts] [l is] JTongue’Grommets Inspect for loose, distorted or broker] 4 grommets. Webbing should not have additional punched holes] [¥s] [se] [Na] ¥] [The outer bars and center bars must be straight Tongue Buckles — Buckle tongues should be ffee of distortion i — 5 hape and motion. re] 7 [xe] _ [sa] [Friction and Mating Buckles — Inspect the buckle for distortion. 6 inspect buckle frame and sliding bar for cracks, distortion, of [Ye] [se] _ [Na] ¥] Karp edges uick-Connect Buckles — Inspect the buckle for distortion. 7 ve] [xe] [al v] Any Other Comments/ flecommendations: ee aes Y Yas: Suitable for Service No: Not Suitable for Service or Repair Required NIA: Not Applicable Koy: Satisfacto ‘This certificate will be null and void If for any reason the limitaiions and conditions set forth herein have been exceeded and ‘or not adhered to. Ths certificate remains valid forthe period stated as long as no modifications, alterations andor repairs done ‘with inthe said period from the date of inspection. The inspection results are relating exclusively forthe equipment inspection carried out. The inspection certiticatelreport shall, not be reproduced except in full without the appraval ofthe inspection body and the client. LIABILITY ‘The Client or his assignosor successor in interes ages to indemnity and hold harmless Arabian Bureau of Services fom and aginst any and allelaims, demands, lawsuits or actions for damages, including legal Tes to person andor precy tangible, intangible or olerwise which ‘nay be brought against Arabian Bureau of Services incidental to arising cut of or in connection with the work t be done, services to be ‘etfonmed or material tobe furised hereunder exsep for those claims easse solely and completely bythe negligence of Arabian Bureau of Services. its diretos officers, employees, agents or sib-ontractos. Under no circumstances whatsoever shal Arabian Bureau of Services be liable for any injury o damage reason of any defect inthe design, materials, machinery, equipment or oer tems whichis the respons inspect under dhe terms specified hereunder. Noshing herein contained sal be deemed to eleve any exes or implied. Inthe event Arabian Burea of Services i proven negligent in any respect, the Lalit of Arabian Bureau of Services, its agent, employees an subcontractors, foe Proprietor’ claims shall ot exced he greater of (US. $1,000) the total compensation paid to Arabian Bureau of Services forthe work. Proprctor shall ave, defend and hol! Arabian Bureau of Secvioes harmless against claims in exoess af US. § 1,000 the {ofl compensation paid te Arabian Bureas of Services forthe work any person ot property occuring by ‘of Arabian Bureau of Sewvices (> ve manaictre ois wavranis, Form ABOS RC G08 Rev.03 on 01/11/2021 Page 2 of 2 Head Office Abu Dhabi P.O.Box : 47133 Abu Dhabi - U.A.E Tel. : (971 2) 6674166 Fax : (971 2) 6674966 E-mail : abosad@eim.ae itt Web : www.abosad.com ne ge ee take Arabian Bureau of Services Mussaflth Office P.O.Box : 47133 Abu Dhabi - U Tel. :(971 2) S51 Fax : (971 2) 3511590 -mail : abos@abosad.com. Web : www.abosad.com MINISTRY OF LABOUR APPROVED CRANE & LIFTING EQUIPMENT INSPECTION ENGINEERS | Job No: OR 01372 Date of Inspection: 1082023 Certificate No:__|_AD/10037/23 JA Date of Centficat: 02/08/2023 The equipment detailed below was examined in Group Standard “HSE-OS-ST19" and Ref Std : BS EN 361 002 ardance with UAE Law De ‘AMB HERTEL, Owner P.O, Box: 113955, Abu Dhabi, UAE Equipment Name Safety Harness | Location of Inspection Ruwais Type of Inspection ‘Thorough Examination Date of Last Inspection jt 1/02/2023 Date ofLastNDT_[ N/A Date of Last Proof Load Test | N/A Summary: The following “Safety Harness” have been Thorough Examined Function tested and found to be suitable for further service with recommendations as given hereunder. Serial No. Description S.Wike Ree ommendations ‘SAFETY HARNESS 220028/0226/1703 220028/0951/1485 |Full body safety harness X c/w double 220025/0081/1451 lanyard 1.8mtr & Shock Absorber 220025/0147/1471 220025/0182/1192 |Viake : STABLL. 220025/0187/1 122, 100kg Found Satisfactory and Safe to use identified above: 220025/0112/1290 220025/0145/1997 220025/0228/1969 220025/0164/1759 THOROUGH EXAMINATION REVIEW: Ts this the first examination after instalation or assembly at a new site or location? NES nor the answer to the above question is VES, has the equipment been installed an " Yes No ‘Was the examination | Examination Exceptional Sematoa? =" [6memis | ¥ [rooms] | ERE | | cpus Identification of any part found to have a defect which is or could become danger to persons and description of the defect: (if none state NONE) NONE Ts the above defects which is not yet but oF Nor immediate danger wo persons? appuicanue | “| YES Ne CIFVES state the date by when) YES By: Particulars oF any repair, renewal or alteration required to remedy he defect | Noy Particulars of any tests carried out as part of the examination: (if none state NONE) Thorough Examination IS THIS EQUIPMENT SAFE TO OPERATE? YES v NO. Colour Code: BLUE 1 certify on behalf of the Third-Party Company named above that the items described herein were Thoroughly Examined by myself being a Competent Person and were found atthe tine of inspection free from cracks, flaws. or other defects, unless otherwise stated above and considered to be Safe for Further Use, subject to continuous ‘maintenance being applied and qualified operator/user being employed Boris Becker orm ABOS RC 008 Rev.03 UdiML BYALITY FOR THE ENGINEERING 31/01/2024 ‘Next ProofLoad Test Ducon; Not Ap Reviewed! Authorized By: Leodhas Arabian Bureau OF Services WORLD vf INS Page T of 2 FULL MEMBER OF LIFTING EQUIPMENT ENGINEERS ASSOCIATION (LEEA)- UK Certificate No: AD/10037/23 JA No. Safety Hamess CHECK LIST a [Cook Tor Fayed edges, broken fibers, pulled sitehes, cuts, burn find chemical damage P.RiresBack Pads — Check D-rings for distortion, cracks, breaks| 2 hand rough or sharp edges, Remarks vel” [se] [8a] vel [se] sa] Tlachment of Buckles — Inspect for any unusual wear, Rayed off — = 3 cut fibers, or broken stitching of the buckle or D-ring attachments | [¥s|% [|__|] ‘onguelGrommets Inspect for loose, distorted or broker 4 grommets. Webbing should not have additional punched holes) [Ye] [%»] [Na] ¥] [The outer bars and center bars must be straight. [Tongue Buckles — Buckle tongues should be free of distortion i Shape and motion. Friction and Mating Buckles — Inspect the buckle for distortion 6 [inspect buckle frame and sliding bar for cracks, distortion, of [Ye] [8°] [84] ¥] harp edges uick-Connect Buckles — Inspect the buckle for distortion, ree] [re] _ [8a ve]_[s] [sa] ¥] Any Other Comments) Recommendations: Sonar ATL Date: 01/08/2023 Key: Satistactor Vos Sutabo for Service No: Not Suitable for Service or Repair Required INIA: Not Applicable ‘This certificate will be null and void If for any reason the linitalions and conditions set forth herein have been exceeded and ‘or not adhered to. Ths certificate remains valid forthe period stated as long as no modifications, alterations andlor repairs done with inthe said period from the date of inspection ‘The inspection resulis are relating exclusively forthe equipment inspection caried out. The inspection cectficate/teport shall not be reproduced except in fll without the approval of the inspection body and the elfen. LIABILITY. “The Client or his assignee or successor in interes agrees indemnify and hold harmless Arabian Bureau of Services from and aginst any and all claims, demands, lawsuits or actions for damages, including legal Fes to person andor property tangible, intangible or otherwise Which may be brought aguinst Arabian Bureau of Sevices incidental aising ou of in connect with tbe werk to be done, services to be Performed or material wo be furnished hereunder except for these claims caused solely and completely by the negligence of Arabian Bureau of Serves, directors, offices, employees, agents or sub-contractors. Under no circumstances whatsoever shall Arabian Buren of Services be Hable for ay injuy o damage wo any person or property occuring by reason of any defect in the design, materials, machinery, equipment o othe items which s the esponsibility of Arabian Bureau of Services to Inspect under the terms specified hersunder” Nothing heen comand shall be deemed to relieve any seller or manufacturer ts warrants ‘express or implied, Inthe event Arabian Bureau of Sarvices is proven neligent in any respect. the ibility of Arabian Bureau of Services, agents, employees and subvontractrs, or Propristor’s claims shall not exceed the greater of BUS § 1,000) the total compensation pad to Arabian Bureau of Serves forthe work. Proprietor shall ave, defend and old Arabian Bureau of Services harmless against claims in excess of US. $1,000 the tol compensation paid to Arabian Bureau of Services forthe work Form ABOS RC 008 Rev.03 on 01/11/2021 Page 2 of 2

You might also like