Professional Documents
Culture Documents
NP 3202 SH 3 272
NP 3202 SH 3 272
Technical specification
Curves according to: Water, pure Water, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
88
84
80
76
72
68
64
60
56
52
65%
48
44
40
36
32 272 244mm
28
24
20
16
12
8
4
0
0 10 20 30 40 50 60 [l/s]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
Configuration
be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Discharge diameter
100 mm
Inlet diameter
150 mm
Number of blades
2
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.90 93.0 % 0.207 kg m² 30
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.87 93.5 % 560 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.80 93.0 % 187 A
Curves according to: Water, pureWater, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
88
84
80
76
72
70.5 m
68
64
60
56
52
65%
48
44
40
36
32 272 244mm
28
24
20
16
12
8
4
[%]0
Efficiency
60 Overall efficiency
272272 244mm
244mm
50 45.6 %
40 42.6 %
30
20
10
0
[kW] Power input P1 272 244mm (P1)
Shaft power P2 272 244mm (P2)
36 32.8 kW
32
28 30.7 kW
24
20
16
12
[m] NPSH-values
272 244mm
14
12
10
NPSHR = 10 m
8
6
4 4.48 m
20.2 l/s
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees. Curve: ISO 9906
Xylect-21593995 AYON BOSE
0 Created on 12/16/2023 Last update 12/16/2023
[m] Head
88
84
80
76
72
70.5 m
68
64
60
56
52
65%
48
44
40 65%
36
272 244mm
32 65%
28
45 Hz
24 65%
40 Hz
20
65%
16 35 Hz
12 30 Hz
8
4
20.2 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Spec. Energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 20.2 70.5 30.7 20.2 70.5 30.7 45.6 % 0.451 4.48
72
70.5 m
68
64
60
56
52
65%
48
44
40 65%
36
272 244mm
32 65%
28 0.179 kWh/m³
45 Hz
24 65%
40 Hz
20
65%
16 35 Hz
12 30 Hz
8
4 12.15 l/s
30 Hz 20.2 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 50 Hz 20.2 70.5 30.7 20.2 70.5 30.7 45.6 % 0.451 4.48
1 45 Hz 18.2 57.1 22.4 18.2 57.1 22.4 45.6 % 0.367 3.79
1 40 Hz 16.2 45.1 15.7 16.2 45.1 15.7 45.6 % 0.293 3.14
1 35 Hz 14.2 34.6 10.5 14.2 34.6 10.5 45.6 % 0.231 2.53
72
70.5 m
68
64
60
56
52
65%
48
44
40 65%
36
272 244mm
32 65%
28 0.179 kWh/m³
45 Hz
24 65%
40 Hz
20
65%
16 35 Hz
12 30 Hz
8
4 12.15 l/s
30 Hz 20.2 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 30 Hz 12.1 25.4 6.64 12.1 25.4 6.64 45.6 % 0.179 1.98
700
135 565
115
3" Guidebars
1275
Z Z
400
405
270
15
50
110
min 200
45°
250
1180
Ref. line 950
23
250
250
200
250
Outlet center line
VIEW Z Z