Technical specification
Curves according to: Water, pure Water, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
100
96
92
88
84
80
76
72
68
64
60
56 63.6%
52
48
44
40
271 257mm
36
32
28
24
20
16
12
8
4
0
0 10 20 30 40 50 60 [l/s]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
Configuration
be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Discharge diameter
100 mm
Inlet diameter
150 mm
Number of blades
2
Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.90 93.0 % 0.212 kg m² 30
Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.87 93.5 % 560 A
Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.80 93.0 % 187 A
Curves according to: Water, pureWater, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
100
96
92
88
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
44
40
271 257mm
36
32
28
24
20
16
12
8
4
[%]0
Efficiency
60 Overall efficiency
50 271271 257mm
257mm
42.7 %
40
39.8 %
30
20
10
0
[kW] Power input P1 271 257mm (P1)
45 Shaft power P2 271 257mm (P2)
40 39.3 kW
35 36.7 kW
30
25
20
15
10
[m] NPSH-values
271 257mm
14
12
10
NPSHR = 10 m
8
6
4 4.46 m
19.9 l/s
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees. Curve: ISO 9906
Xylect-21594127 AYON BOSE
0 Created on 12/16/2023 Last update 12/16/2023
[m] Head
100
96
92
88
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4
19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Spec. Energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 19.9 80.3 36.7 19.9 80.3 36.7 42.7 % 0.549 4.46
96
92
88
0.549 kWh/m³
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz 0.213 kWh/m³
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4 11.924 l/s
30 Hz 19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 50 Hz 19.9 80.3 36.7 19.9 80.3 36.7 42.7 % 0.549 4.46
1 45 Hz 17.9 65 26.8 17.9 65 26.8 42.7 % 0.444 3.77
1 40 Hz 15.9 51.4 18.8 15.9 51.4 18.8 42.7 % 0.354 3.12
1 35 Hz 13.9 39.3 12.6 13.9 39.3 12.6 42.7 % 0.277 2.52
96
92
88
0.549 kWh/m³
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz 0.213 kWh/m³
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4 11.924 l/s
30 Hz 19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 30 Hz 11.9 28.9 7.93 11.9 28.9 7.93 42.7 % 0.213 1.97
700
135 565
115
3" Guidebars
1275
Z Z
400
405
270
15
50
110
min 200
45°
250
1180
Ref. line 950
23
250
250
200
250
Outlet center line
VIEW Z Z