NP 3202 SH 3~ 271

Patented self cleaning semi-open channel impeller, ideal for pumping in


most waste water applications. Modular based design with high
adaptation grade.

Technical specification
Curves according to: Water, pure Water, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
100
96
92
88
84
80
76
72
68
64
60
56 63.6%
52
48
44
40
271 257mm
36
32
28
24
20
16
12
8
4
0
0 10 20 30 40 50 60 [l/s]
Curve: ISO 9906
Nominal (mean) data shown. Under- and over-performance from this data should
Configuration
be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.

Motor number Installation type


N3202.185 30-27-2AA-W P - Semi permanent, Wet
47KW
Impeller diameter Discharge diameter
257 mm 100 m m

Pump information Material


Impeller diameter Impeller
257 mm Hard-Iron

Discharge diameter
100 mm

Inlet diameter
150 mm

Maximum operating speed


2955 rpm

Number of blades
2

Max. fluid temperature


40 °C

Project Xylect-21594127 Created by AYON BOSE


Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
Technical specification
Motor - General
Motor number Phases Rated speed Rated power
N3202.185 30-27-2AA-W 3~ 2955 rpm 47 kW
47KW
Approval Number of poles Rated current Stator variant
No 2 73 A 5

Frequency Rated voltage Insulation class Type of Duty


50 Hz 440 V H S1
Version code
185

Motor - Technical
Power factor - 1/1 Load Motor efficiency - 1/1 Load Total moment of inertia Starts per hour max.
0.90 93.0 % 0.212 kg m² 30

Power factor - 3/4 Load Motor efficiency - 3/4 Load Starting current, direct starting
0.87 93.5 % 560 A

Power factor - 1/2 Load Motor efficiency - 1/2 Load Starting current, star-delta
0.80 93.0 % 187 A

Project Xylect-21594127 Created by AYON BOSE


Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
Performance curve
Duty point
Flow Head
19.9 l/s 80.3 m

Curves according to: Water, pureWater, pure [100%],4 °C,999.9 kg/m³,1.569 mm²/s
[m] Head
100
96
92
88
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
44
40
271 257mm
36
32
28
24
20
16
12
8
4
[%]0
Efficiency
60 Overall efficiency
50 271271 257mm
257mm
42.7 %
40
39.8 %
30
20
10
0
[kW] Power input P1 271 257mm (P1)
45 Shaft power P2 271 257mm (P2)
40 39.3 kW
35 36.7 kW
30
25
20
15
10
[m] NPSH-values
271 257mm
14
12
10
NPSHR = 10 m
8
6
4 4.46 m
19.9 l/s
0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees. Curve: ISO 9906
Xylect-21594127 AYON BOSE
0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
Duty Analysis

Curves according to: Water, pure [100%] ; 4°C; 999.9kg/m³; 1.569mm²/s

[m] Head
100
96
92
88
84
80 80.3 m
76
72
68
64
60
56 63.6%
52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4
19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating characteristics
Pumps / Flow Head Shaft power Flow Head Shaft power Hydr.eff. Spec. Energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 19.9 80.3 36.7 19.9 80.3 36.7 42.7 % 0.549 4.46

Project Created by AYON BOSE


Block Xylect-21594127 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
VFD Curve

Curves according to: Water, pure ,4 °C,999.9 kg/m³,1.569 mm²/s


[m] Head
100
95
90
85
80
75
70
65
60
55 63.6%
50
45 63.6%
40
271 257mm
35 63.6%
30 45 Hz
25 63.6%
40 Hz
20 63.6% 35 Hz
15 30 Hz
10
5
[%]0
Efficiency
60 Overall efficiency 30 Hz 35 Hz 40
40 Hz
Hz 45
45 Hz 271
Hz 271 257mm
257mm
50 30 Hz 35 Hz
40
30
20
10
0
[kW] Pow er input P1 271 257mm (P1)
271 257mm (P2)
Shaft pow er P2
40
45
45 Hz
Hz
30
40
40 Hz
Hz
20
35
35 Hz
Hz
10 30
30 Hz
Hz
[m] NPSH-values 271 257mm
14
45 Hz
12
10 40 Hz
35 Hz NPSHR = 10 m
8
6 30 Hz
4
2
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances. Curve: ISO 9906
Please consult your local Flygt representative for performance guarantees.
Project Xylect-21594127 Created by AYON BOSE
Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 999.9kg/m³; 1.569mm²/s


[m] Head 1 Specific energy
100 [kWh/m³]

96
92
88
0.549 kWh/m³
84
80 80.3 m
76
72
68
64
60
56 63.6%

52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz 0.213 kWh/m³
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4 11.924 l/s
30 Hz 19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 50 Hz 19.9 80.3 36.7 19.9 80.3 36.7 42.7 % 0.549 4.46
1 45 Hz 17.9 65 26.8 17.9 65 26.8 42.7 % 0.444 3.77
1 40 Hz 15.9 51.4 18.8 15.9 51.4 18.8 42.7 % 0.354 3.12
1 35 Hz 13.9 39.3 12.6 13.9 39.3 12.6 42.7 % 0.277 2.52

Project Xylect-21594127 Created by AYON BOSE


Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
VFD Analysis

Curves according to: Water, pure [100%] ; 4°C; 999.9kg/m³; 1.569mm²/s


[m] Head 1 Specific energy
100 [kWh/m³]

96
92
88
0.549 kWh/m³
84
80 80.3 m
76
72
68
64
60
56 63.6%

52
48
63.6%
44
40
271 257mm
36 63.6%
32 45 Hz 0.213 kWh/m³
28 63.6%
24 40 Hz
20 63.6% 35 Hz
16
30 Hz
12
8
4 11.924 l/s
30 Hz 19.9 l/s
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 [l/s]
Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances.
Please consult your local Flygt representative for performance guarantees.
Operating Characteristics
Pumps / Frequency Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific energy NPSHre
Systems
l/s m kW l/s m kW kWh/m³ m
1 30 Hz 11.9 28.9 7.93 11.9 28.9 7.93 42.7 % 0.213 1.97

Project Xylect-21594127 Created by AYON BOSE


Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT
NP 3202 SH 3~ 271
Dimensional drawing

700
135 565
115
3" Guidebars

Min water level*


250
DN100

1275
Z Z
400

405
270
15

50
110
min 200

45°
250

1180
Ref. line 950

23
250

250

Ø20(4x) 22 Ref. line


100

200

250
Outlet center line

VIEW Z Z

Weight (kg) Pump Discharge


withcooling jacket 550 42
* Only applicable for intermittent duty.
Consult the IOMfor more info. without cooling jacket 500 42
D ischarge DN 100 S cale Date
FP,NP 3202 SH outlet
P ump outlet DN 100 1:40 220921
P ump inlet Revision
D raw ing number
095,185,350,390,660,670 S uction
inlet
7632100 5

Project Xylect-21594127 Created by AYON BOSE


Block 0 Created on 12/16/2023 Last update 12/16/2023

Program version Data version User group(s)


71.0 - 17/11/2023 (Build 91) 13/12/2023 10:49 Xylem: India - EXT