You are on page 1of 7

Make sure your Adobe Acrobat Reader is up

SCHEMATIC FEATURES AND TIPS


to date in order to access the latest features
of this schematic.

GET
Adobe Acrobat Reader

SAVE
a copy of this schematic

THE BOOKMARKS PANEL WILL ALLOW YOU TO THE FUNCTION ISOLATION TOOLS ISOLATE
QUICKLY NAVIGATE TO POINTS OF INTEREST. CIRCUITS FOR TRACING HYDRAULIC LINES

Function Isolation Tools

Grids On/Off

All Circuits Off


STANDARD VIEW
All Circuits On

021 (Orange) (Pilot Pump Output)

032 (Red) (Main Pump Output)

577 (Lt Green) (Drain/Return Line)

Machine Views

Machine View - Front

Machine View - Rear

Implement Stack 021 (Orange) (Pilot Output)


CIRCUIT ISOLATED
CLICK HERE TO VIEW THE SCHEMATIC
UTILIZE HYPERTEXT TO NAVIGATE TO COMPONENTS AND THEIR MACHINE LOCA- SYMBOLS AND DEFINITIONS PAGE
TION QUICKLY. HYPERTEXT IS INDICATED BY TEXT THAT IS BLUE AND UNDERLINED. ELECTRICAL SYMBOLS

Pressure Temperature Level


Switch Switch Switch Circuit Breaker

BASIC HYDRAULIC SYMBOLS

Fluid Pump Spring


Variability
Conditioner or Motor (Adjustable)

HOTKEYS (Keyboard Shortcuts)

FUNCTION KEYS
Zoom In “CTRL” / “+”
Zoom Out “CTRL” / “-”
Fit to Page “CTRL” / “0” (zero)
Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
WHEN ONLY ONE CALLOUT IS SHOWING ON A Search “CTRL” / “SHIFT” / “F”

MACHINE VIEW, CLICKING ON THIS BUTTON WILL


VIEW ALL CALLOUTS MAKE ALL OF THE CALLOUTS VISIBLE. THIS
Due to different monitor sizes and PDF reader
preferences there may be some variance in linked
BUTTON IS TYPICALLY LOCATED IN THE TOP RIGHT schematic locations. This document is best viewed at
CORNER OF EVERY MACHINE VIEW PAGE. a screen resolution of 1024 X 768.

© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
SCHEMATIC SYMBOLS AND DEFINITIONS
VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC
ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

PILOT CONTROL Line Restriction


MAIN AUX.

2-Section
RELEASED PRESSURE Variable and Pressure
ROTATING SHAFTS Compensated
Pump

External Return Internal Return Unidirectional Bidirectional


REMOTE SUPPLY PRESSURE Attachment Pump: Variable and
Pressure Compensated

Internal
Simplified Complete Supply Pressure Hydraulic Pneumatic
Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.). 111-7898 3E-5179
No circle indicates that the wire cannot be disconnected from the component. Part Number: for 1
Connector Plug
Ground (Wired): This indicates that the component is connected to a grounded wire. 2
The grounded wire is fastened to the machine.
Plug Receptacle
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity. 325-AG135 PK-14
It has a coil that makes an electromagnet when current flows through it. Harness identification code:
This example indicates wire group 325, Wire Gauge*
The electromagnet can open or close the switch part of the relay. wire 135 in harness "AG". Wire Color
*Wire gauge is shown in AWG (American Wire Gauge)
Solenoid: A solenoid is an electrical component that is activated by electricity. but could also be shown in metric denoted with mm
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work. 1 Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
2 sockets and the receptacle contains all pins.
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet 1 Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places of a Sure-Seal connector. The plug and receptacle
2 contain both pins and sockets.
the latch coil circuit open at the time the coil latches.

© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE


WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used
herein, are trademarks of Caterpillar and may not be used without permission.
M0136575
May 2022

785 Dynamic Gas Blend (DGB)


without the Economizer
Conversion System
YDG1-UP
APX1-UP

PUBLICATIONS.CAT.COM
© 2022 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Corporate Yellow”, the “Power Edge”
and Cat “Modern Hex” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION

Schematic Machine
Description
Location Location
Filter As B-5 1
Gauge - Pressure 1 D-4 2
Gauge - Pressure 2 D-4 3
Receptacle - Liquid Natural Gas E-7 4
Receptacle - Vent E-5 5
Regulator Gp B-4 6
Strainer - Liquid Natural Gas E-7 7
Tank - LNG Fuel E-6 8
Valve - Chassis Relief A-5 9
Valve - Check 1 (Not Shown) C-3 10
Valve - Defuel Relief C-4 11
Valve - Defuel Shut Off B-4 12
Valve - Engine Vent A-3 13
Valve - Excess Flow C-7 14
Valve - Fill Line Check C-7 15
Valve - Fill Line Shut Off D-7 16
Valve - Line Relief D-7 17
Valve - Primary Relief D-7 18
Valve - Secondary Relief C-7 19
Valve - System Vent A-6 20
Valve - Tank Isolation B-7 21
Valve - Vent Shut Off E-5 22
Valve As - Thermal Relief A-5 23
Valve Gp - Fuel A-3 24
Valve Gp - Gas Actuation A-4 25
Vaporizer As - Liquid Natural Gas A-6 26
7 6 5 4 3 2 1

(8) TANK - LNG FUEL


FILL RECEPTACLE 535-9639

(5) RECEPTACLE - VENT


(4) RECEPTACLE - LNG 469-0944
550-5381 DEFUEL & VENT RECEPTACLE
E E

(22) VALVE - VENT


(7) STRAINER - LNG
535-9641 SHUT OFF
459-9151

N1 LNG INLET (2) GAUGE - PRESSURE 1


N2 GAS VENT 459-9143
N3 LNG OUTLET
(18) VALVE - PRIMARY RELIEF
579-5197

D (3) GAUGE - PRESSURE 2 D


(17) VALVE - LINE RELIEF 459-9143
550-5376 N1 N2 N3

(16) VALVE - FILL LINE


SHUT OFF
535-9643

(15) VALVE - FILL LINE CHECK


550-5380

(19) VALVE - SECONDARY


RELIEF
C 459-9144 C

(10) VALVE - CHECK 1


(11) VALVE - 602-7236
DEFUEL RELIEF
459-9145 BOOST REFERENCE
(14) VALVE - EXCESS FLOW
550-5378

(12) VALVE -
DEFUEL
(Dimensions: 34 inches x 24 inches)

SHUT OFF (6) REGULATOR GP


(21) VALVE - TANK
459-9151 596-2998
ISOLATION
535-9642

B (1) FILTER AS B
VENT STACK LNG OUT
M0136575

465-3352

LINE PATTERNS
PRD

Pressure Line
(24) VALVE GP - FUEL
Pilot / Load Sensing Pressure
(26) VAPORIZER AS - LNG 596-1051
Drain / Return Lines
554-3064
Air Line

(25) VALVE GP - (13) VALVE - ENGINE VENT HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
Component Group
16 Page,

GAS ACTUATION 109-0897 HOT JACKET WATER CALLOUTS


GAS VENT LINE
516-8290 COMPRESSED NATURAL GAS
YY Taps (Pressure, Sampling, Sensor - by letter)
LIQUID NATURAL GAS
AIR LINE DL DL D Connectors (By letter)
A COLD JACKET WATER
Callout Number Component A
(52) VALVE GP - CONTROL
(20) VALVE - SYSTEM VENT (Machine Location from
Component LocationsTable)
138-1234 Part Number
Name

459-0623
THIS SCHEMATIC IS FOR THE 785 DYNAMIC GAS BLEND (DGB) WITHOUT
(9) VALVE - CHASSIS RELIEF (23) VALVE AS - THE ECONOMIZER CONVERSION SYSTEM
579-5197 THERMAL RELIEF Do not operate or work on this product unless you have MEDIA NUMBER: M0136575
read and understood the instruction and warnings in the
553-0293 relevant Operation and Maintenance Manuals and SCHEMATIC PART NUMBER: 457-6003, CHANGE: 04, VERSION: -
relevant service literature. Failure to follow the instruc- Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
tions or heed the warnings could result in injury or
in neutral and with parking brake set.
death. Proper care is your responsibility.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

7 6 5 4 3 2 1
ENGINE FRONT
VIEW ALL CALLOUTS

24

25

13

6
LIQUID NATURAL GAS TANK
VIEW ALL CALLOUTS

16

19

15

14

20 2 22 5 7 4
21

23

17

12

3
18
11
26 1

You might also like