Professional Documents
Culture Documents
Hexing DCU Data Model Object Model DCU V1.1
Hexing DCU Data Model Object Model DCU V1.1
3 time_zone -60 --
4 status --
5 daylights_savings_begin "FFFF03FE07020000 --
008000FF"
6 daylights_savings_end "FFFF0AFE07030000 --
008000FF"
7 daylights_savings_deviation 60 --
8 daylights_savings_enabled 1 --
9 clock_base 1 --
Abstract objects - Push setup
Push Setup - On Connectivity 40 0 0-0:25.9.0.255
1 logical_name "0000190900FF" --
2 push_object_list --
3 send_destination_and_method {[0..4],*,0} --
4 communication_window --
5 randomisation_start_interval 0 --
6 number_of_retries --
7 repetition_delay --
1 push --
Remote communication - Abstract Objects for
Network Mgmt
Auto Connect 29 2 0-0:2.1.0.255
1 logical_name "0000020100FF" --
2 mode 101 --
3 repetitions 0 --
4 repetition_delay 0 --
5 calling_window --
6 destination_list --
1 connect --
Image Transfer 18 0 0-0:44.0.0.255
1 logical_name "00002C0000FF" --
2 image_block_size --
3 image_transferred_block_status --
4 image_first not_transferred_block_number --
5 image_transfer_enabled --
6 image_transfer status --
7 image_to_activate_info --
1 image_transfer_initiate --
2 image_block_transfer --
3 image_verify --
4 image_activate --
-- Get
-- Get
Get
Set Get, Set
-- Get
-- Get, Set
-- Get, Set
-- Get, Set
-- Get, Set
-- Get, Set
-- Get, Set
Action Action
-- Get
-- Get, Set
-- Get, Set
-- Get, Set
-- Get, Set
-- Get, (Set)
-- Action
-- Get
-- Get, (Set)
-- Get
-- Get
-- Get, Set
-- Get
-- Get
-- Action
Action Action
-- Action
-- Action
-- Get
-- Get, Set
-- Get, Set
-- Get, Set
Comments
Comments
E-meter serial number (Serial number of the device, handled by the manufacturer); ASCII coded
Current date and time as local time, deviation can be handeled or set to 0x8000, status must be handled.
With Set deviation=0x8000 and status=0xFF
Randomiztion time in seconds, 0 = no randomization at start of the first window defined in calling_window
An APN with a size of 64 bytes at least is supported, i.e. [0.64] is mandatoty but can be longer
Standard Event Log Fraud Detection Log
0-1:96.11.0.255 0-1:96.11.1.255
Code Name Code
1 Clock adjusted(old date/time) 1
2 Clock adjusted(new date/time) 2
3 Replace battery
8 Power up
9 Power down
Fraud Detection Log
0-1:96.11.1.255
Name
Main cover removed
Main cover closed