You are on page 1of 5
Issued by Test certificate Nederlands Meetinstituut Number T6862 revision 0 Project number 509535 Page 1 of 5 NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands Notified Body Number 0122 In accordance Paragraph 8.1 of the European Standard on Metrological aspects of with Applicant In respect of Characteristics Electronic, self-indicating de\ Description and The instrument is describe non-automatic weighing instruments EN 45501:1992/AC:1993 and the Welmec guide for testing indicators (Welmec 2.1, August 2001). Mettler-Toledo (Changzhou) Precision Instrument Ltd. No.5 Middle HuaShan Road, ChangZhou 213022 Jiangsu China ‘The model of an indicator, tested as a part of a weighing instrument (for non-automatic weighing instruments class @D and GD), Manufacturer : Mettler-Toledo Type IND22x e, with single - or multi-range indication. The maximum number of verification scale intervals will be: 11s 6000 for class GD instruments (per weighing range) or 1 < 1000 for class GD instruments (per weighing range). maximum of two weighing ranges Temperature range -10 °C /-+40 °C In the description number TC6862 revision 0 further characteristics are described. in the description number TC6862 revision 0 and Documentation documented in the documentation folder number TC6862-1, appertaining to this Remarks test certificate, Summary of the test involved: see Appendix number TC6862 revi 13 December 2005 lanager Product Certification Nederlands Meetinstituut Hugo de Grootplein 1 3314 EG Dordrecht Telephone +31 78 6332332 Telefax +31 78 6332309 saa (Chamber of Commerce n9.27228.701) Subsidiary companies: NM Van swindon taboratorirn Bx, (27228703) INMiCertin 81. @7233.818) Verispect 8. (27 228.700) “This document i esved under the provision that MiB. nor Ks subsldlary companies seep any laity Reproduction ofthe complete document is ‘lowed, Parts ofthe document may only be Feproduced ater written permission, Description Number T6862 revision 0 Project number 509535 Page 2 of 5 1 General information about the indicator All properties of the indicator, whether mentioned or not, may not be in conflict with the standard mentioned in the test certificate. 1.1 Essential parts Description Drawing number | Rev. | Remarks Circuit block diagram 72183987 5 PCB IND221 Main board 177448 A 2 pages PCB IND226 Main board 181553 A 2 pages EMC protection measures: = Ferrite around the load cell cable, inside indicator housing (1 turn); - Ferrite around the DC cable between battery charge board and main board (2 turns); - Ferrite around the AC cable between battery charge board and main board (2 turns) 1.2 Essential characteristics List of devices: - Determination stability of equilibrium; = Semi-automatic zero-setting; = Initial zero-setting; = Zero-tracking; - Tare weighing; = (Semi-Jautomatic subtractive tare; + Indication of unstable equilibrium; = Gravity compensation; - Calibration / set-up mode via a switch on the main board; = Acting upon significant faults; = Checking the display; - Check weighing mode (Over/under function and target weight function); = Counting device (PCS); + Indications other than primary indications. Mi Description TL) nedertands Meetinstituut Number TC6862 revision 0 Project number 509535 Page 3 of 5 Connections: ~ Power supply of 100 - 240 V AC 50/60 Hz; - Internal rechargeable battery: - NiMH 6.9V DC or - lead -acid battery 5.6V DC or = dry battery 5.6 V DC; - The applied error fraction p, is 0.5; - The minimum value allowed for the signal voltage per verification scale interval is 1.6667 \V; ~The excitation power supply for the load cell is 5 V DC; - The minimum input impedance of the load cell is 87 2; = The maximum input impedance of the load cell is 350 0; = *Remote-sensing” is used; = _ No special cable length has to be provided for the connection between the indicator and the junction box or load cells. Software: = The software has the identification number: 178037 L1.2, where the xx part represents the non-essential software modifications. = The identification number will be displayed at start-up. 1.3. Essential shapes The indicator is built according to the drawings: = IND220 Head seal drawing, drawing number 72187101 rev. A; = IND226 Head seal drawing, drawing number 72187106 rev. A; - _IND220 Head seal drawing, drawing number 72182102 rev. A: = Exploded view IND220, drawing number 72187100 rev. A; = Exploded view IND221, drawing number 72186379 rev. A; - Exploded view IND226, drawing number 182976 rev. A. The data plate is secured against removal by sealing or will be destroyed when removed and contains the following information: - This test certificate number T6862; ~The calibration counter value; - Manufacturers name or mark. To secure components that may not be dismantled or adjusted by the user, the secured in a suitable manner on the locations indicated in the drawings: = IND226 Head seal drawing, drawing number 72187106 rev. A; = 1ND220 Head seal drawing, drawing number 72182102 rev. A. The securing component has to bear either: = Amark of the manufacturer laid down in a notified body approved quality system (Annex Il of the Directive 90/384/EEQ), or; - _Anofficial mark of a Member State of the EEC, or another party to the EEA agreement. Inside the cabinet is a calibration lock, located on the main board. After pressing the (L=->]-key, the display shall indicate "OIML;”. Description Number TC6862 revision 0 Project number 509535, Page 4 of 5 1.4 Conditional parts Description Drawing number | Rev. | Remarks “| IND22x recharge board 180217 A (NL-MH battery) IND22x recharge board 72187398 A (lead-acid battery) The interface section is located on the main board. The indicator may be equipped with one or more of the following protective interfaces that have not to be secured: = S232, 1.5 Non-essential parts Display; Keyboard. + Appendix Number TC6862 revision 0 Project number 509535 Page 5 of 5 ‘Tests carried out for this test certificate on the Mettler Toledo indicator: Test Type or version | Institute ‘Temperature effect on the sensitivity with minimum, IND226 NMi Certin B.V. weighing range and input impedance of 87 2. (20, 40, -10, 5 and 20 °C) Temperature effect on the no load indication with minimum | IND226 NMi Certin B.V. weighing range and input impedance of 87 2. (20, 40, -10, 5 and 20 °C) Damp heat, steady state IND226 NMi Certin BV. Repeatability IND226 NMi Certin B.V. Warm-up time IND226 NMi Certin B.V. Span stability IND226 NMi Certin B.V. Checklist IND226 NNMi Certin B.V. Cable length between the indicator and load cell IND226 NMi Certin B.V. Stability of equilibrium IND226 NMi Certin B.V. EMC tests are performed with a load cell impedance of 3502 Power voltage variation IND226, IND221_| NMi Certin B.V. Short time power reduction IND226, IND221_| NMi Certin BV. Electrical bursts 1IND226, IND221_| NMi Certin B.V. Electrostatic discharges IND226, IND221_| NMi Certin B.V. Electromagnetic susceptibility IND226, IND221__| NMi Certin B.V.

You might also like