ITEM/PACKAGE TAG V-201 ITEM/PACKAGE TAG PKG-101 ITEM/PACKAGE TAG AR-101 ITEM/PACKAGE TAG P-201 ITEM/PACKAGE TAG SP-103

ITEM/PACKAGE TAG AR-101 ITEM/PACKAGE TAG P-201 ITEM/PACKAGE TAG SP-103 NOTES:
DESCRIPTION ANODE SEPARATOR DESCRIPTION WATER TREATMENT PACKAGE DESCRIPTION AIR CONDITIONER DESCRIPTION ANODE PUMP DESCRIPTION SPACE HEATER
MANUFACTURER ALPHA ECC MANUFACTURER GRÜNBECK MANUFACTURER HOLD-5 MANUFACTURER BEDU POWER 2 kW 1. WATER TREATMENT PACKAGE BY VENDOR.
MATERIALS SS316L CAPACITY ~1.5 m3/hr DUTY HOLD-5 kW MATERIALS SS316L 2. CONNECTED TO (ROOFTOP ) VENT .
3. OXYGEN AND HYDROGEN VENTS TO BE SEPARATED BY 2
OPERATING CAPACITY/SIZE 1.34m3 (Ø938mm x 1700mm) DESIGN PRESSURE ~6 barg POWER 37 KW METERS HORIZONTALLY.
DESIGN PRESSURE -0.5 / 4 barg DESIGN TEMPERATURE 80 °C HEAD 89 mlc 4. WATER TESTING SHALL BE PERFORMED PERIODICALLY TO
OPERATING PRESSURE 0.7 barg DESIGN TEMPERATURE 100 °C CHECK THE PRESENCE OF IRON OXIDE IN THE SYSTEM.
DESIGN TEMPERATURE -20/90 °C OPERATING FLOW 79.7 m3/hr VENT 5. INLET DEVICE HALF OPEN PIPE OPENING UPWARD.
TO SAFE 6. NITROGEN PURGING DURING TRIP DUE TO H2 CONCENTRATION
AC LOCATION IN O2 HEADER
7. OUTLET DEVICE POSITIONED AT OPPOSITE SIDE FROM INLET
GENERAL
20 FT. CONTAINER FAULT AR-101 ESD XA
SET @ 40 FT. CONTAINER NOTE 2 DEVICE.
8. 8 MM INSULATION THICKNESS TO BE CONSIDERED FOR ALL THE

3"-O2-216-1SS150-WT
1.1 barg
PSV
M
FAN-101 XI
AIR CONDITIONER 302C 302
201
NOTE 3 INSULATED LINES.
9. THE PORTION OF LINES BETWEEN TWO CONTAINERS (EXPOSED
105
UTILITY FAN 1.5F2 2"x3"
3"-O2-206-1SS150-NI
TO ATM) SHALL BE ELECTRICAL HEAT TRACED & INSULATED.
10. CONDENSATE TRAP TO BE POSITIONED AS LOW AS POSSIBLE.
OXYGEN VENT 11.FOR SAMPLE SYSTEM P&ID REFER TO P106088-PC-PID-005.
GENERAL GENERAL TP
START/ GENERAL FAULT FAULT 1/2" -O2-109-1SSTA-NI 004 12. CV-101 AND CV-102 INDIVIDUAL PRESSURE DROP SHALL BE
SPACE HEATER ESD ESD RUN FAULT - PROFIBUS -MODBUS RTU
HH=1% VOL/
3"-O2-215-1SS150-NI (TRACING)
BELOW 100 MBAR AT RATED FLOW, E.G. CRACK PRESSURE <=
100 MBAR AND CV VALUE > 8.8
SP-103 25% LEL

3/4"-O2-224-1SSTB-NI
MZ MZ XR XI XI XI AIT AA 13.FLOOR DRAIN OUTLET.
PKG-101A PKG-101B 101 102 103 104 102 102 14. CV-203 INDIVIDUAL PRESSURE DROP SHALL BE BELOW 30MBAR,
TS
TP 103 E.G. CRACK PRESSURE ≤ 30MBAR.
15. SIGNAL IS ADDITIONALLY HARDWIRED TO STACK WITH TRIP
001 2" BSPP-F AMPLIFIER TO STOP POWER TO STACK IN CASE OF TRIP.

1/2"-O2-217-1SSTA-NI
FROM WATER INLET
3/4" 3/4" -WA-101-2SSTB-NI PIPING TUBING

1 1/2"-O2-208-1SS150-NI
1/4"-O2-220-1SSTX-WT
CUSTOMER

BV-209 1 1/2"x3"
6 barg 4 barg
BV-101 3/4"
WATER TREATMENT PACKAGE
TP 1"
002 PKG-101 1" NOTE 10
CT-201

1 1/2"
REJECT WATER

LO
2 1/2" 2 1/2"-RE-102-2SS150-NI NOTE 1, 4 BV-102 CONDENSATE
CUSTOMER TRAP TP

1"-UPW-105-1SSTC-NI
BV-103
003
PCV SET @ 1" 1"-UPW-110-1SS150-NI TO OXYGEN HEADER
506 7 BAR(G) 1 1/2"-O2-207-1SS150-NI 1 1/2" 1 1/2" 1 1/2"
-

1"-UPW-111-1SS150-NI
6 barg PIPING CV-201 CV-202 BV-208
INSTRUMENT AIR

CV-203
1/2" BV-104 15 barg TUBING LC

1/4"
1"
CSO NOTE 14 HOLDS:
PACKAGE PKG-501 1"-UPW-104-1SSTC-NI CONTINUED FROM
RD-201 W P106088-PC-PID-002 1. DELETED.
RO 2. INSTRUMENT SET POINT.
SET @
REFER CSS - ALARM & TRIP SET POINT

1 1/2"-O2-211-1SS150-NI
1.2 BARG 201
1/2''-RE-225-1SSTA-NI TO DRAIN LIST - P106088-IC-CSS-001_0.4
TP 3. DELETED.
1/2"
012 H2 IN O2 P106088-PC-PID-004 4. DELETED.
NOTE 13 SAMPLE PANEL H2 5. VENDOR DETAILS UNDER HOLD.
1/2" W W

1 1/2"x1"
XI HH=1% H2 IN O2 (25% LEL)
NOTE 11
501 AIT AA
(TRACING) (TRACING)
201 201
FAULT I/P SDVS
ALARM 1"-UPW-107-1SSTC-WT PY NOTE 9

1 1/2"x1" FO
// 201
202
1"-UPW-106-1SSTC-WT
FALL
PCV
205
202 1 1/2"
LL
FO
1"

3/4"-O2-223-1SSTB-NI
TO IA CONSUMERS CV-101 W 1/4"-O2-218-1SSTX-WT
1" NOTE 12 SDV TO DRYER PACKAGE
CV-102 201 (TRACING) DX-601

1 1/2"-O2-205-1SS150-NI
1"-CL-417-2SSTC-NI
NOTE 9 P106088-PC-PID-004

1"-UPW-103-1SSTC-NI
FROM DOWNSTREAM HX201
HX-202
1"-UPW-214-1SSTC-NI
P106088-PC-PID-002 INLINE COOLER
1/2"-O2-212-1SSTA-NI

1 1/2"-O2-204-1SS150-NI
H 1/2"-O2-221-1SSTA-NI
LCV PIC SET @
HH=0.9 barg 0.7 barg
202
I/P 201 PI
LY // // // //
FC
201
L FROM CHILLER CH-101
TERMINATION POINT
201 LL=0.4 barg CT-202 P106088-PC-PID-003
1"-CL-411-2SSTC-NI TP DESCRIPTION SIZE
PT PG CONDENSATE
SET @ 202 202 TRAP TP001 WATER INLET 3/4"-O.D BULKHEAD
PCV 0 BARG PT
503 VENT TP002 REJECT WATER 2 1/2'' 150#
201 4barg ATM 1/2"-RE-219-1SSTA-NI
FROM STACK ELX-001 OXYGEN HEADER TO
1/2"-N2-509-2SSTA-NI N5A 4"-O2-203-1SS150-NI TP003 1 1/2'' 150#
CLIENT
INST. 1 1/2" P106088-PC-PID-002
1/2" 6"x4" OXYGEN VENT TO SAFE 3'' 150# HEADER WITH 6" OD
BV-201 TUBING TP004
INST. PIPING LOCATION VENT PIPE
NC
N1 N2 N3 N4 N5 N6 FLOOD DRAIN UTILITY
N11A TP012 1" 150#
1" 1/2" 1 1/2" 1/2" 6" AREA
3"
PIPING INST. 6"
HH=684mm
N12A NOTE 5
LSHH LAHH
1" 201 201
H HHLL +684
M1 REFERENCE DOCUMENT
LIC
201
SET @
500 MM
LT
201
HLL
NLL
+584
+484
V-201 20" P106088-PC-PFD-001 & 002 PROCESS FLOW DIAGRAM
N12B LLL +384
L
DP TYPE 1"
LSLL
202
LALL
202
LLLL +284 ANODE SEPARATOR P106088-PC-EQP-001 EQUIPMENT LIST
P106088-PC-BOD-001 BASIS OF DESIGN
N10
3/4" LL=284mm
3" NOTE 7 6" NOTE 15
N11B ALLAGASH_MANUAL_REV18.6 STACK MANUAL
N9
LEGEND SHEET PLUG POWER 10 x 1MW
INST. PIPING 4 barg 6"
BV-203 FOR 14.12
MZ C APPROVAL 2022 HLB MKu AKU KSI SDo
15 barg
P201 FOR 15.06
NOTE 6 B APPROVAL 2022 HLB MKu AKU KSI VRD
FOR 14.03
6"-UPW-201-1SS150-NI

FROM FIC-202 A APPROVAL 2022 HLB MKu AKU KSI VRD


SDVS
FOR 21.12
501 VFD P106088-PC-PID-002 O APPROVAL 2021 HLB MKu AKU KSI VRD
Check Check Check Appr.
Rev. Description Date Drawn
Proc. Mech. Instr.

SDV M TO ANODE HEAT


501 EXCHANGER HEX-201 CUSTOMER : PLUG POWER
FROM NITROGEN HEADER 3" 4"-UPW-202-1SS150-NI CUSTOMER REF. : PO134440
1/2"-N2-503-2SSTA-NI 1/2" 1/2" 1/2"-N2-511-2SSTA-NI P106088-PC-PID-002
PLUG REF. : P106088
P106088-PC-PID-002 6"x4" 4" 3"x4"
CV-502 FC NV-502 PROJECT : PLUG POWER 10x1 MW
1" TM
P.O. Box 15
BV-204
Alphen aan den Rijn
HH=90 °C The Netherlands

TAHH TT P-201 It is forbidden to copy or use in whole or in part outside the strict
contract terms, without the prior written consent of a Plug Power company.
206 206
ANODE PUMP Title:
TYP. DETAIL 1 FROM CATHODE PIPING AND INSTRUMENT DIAGRAM
SEPARATOR V-301 PLUG POWER 10x1 MW
3/4"-UPW-308-1SSTB-NI ANODE SEPARATOR & WATER TREATMENT PACKAGE
P106088-PC-PID-003

Drwg.No.:
Scale: NTS
CONTINUED FROM P106088-PC-PID-002 P106088-PC-PID-001 Size: A1
ITEM/PACKAGE TAG HX-201 ITEM/PACKAGE TAG FAN-201 ITEM/PACKAGE TAG ELX-001 ITEM/PACKAGE TAG P-401 ITEM/PACKAGE TAG V-501 ITEM/PACKAGE TAG AC-401 NOTES:
DESCRIPTION ANODE HEAT EXCHANGER DESCRIPTION VENTILATION FAN DESCRIPTION STACK DESCRIPTION COOLANT PUMP DESCRIPTION NITROGEN BUFFER DESCRIPTION AIR COOLER
MANUFACTURER ALFA LAVAL FLOW RATE 5000 @ 415 Pa m3/hr MANUFACTURER PLUG POWER MANUFACTURER BEDU MATERIALS SS304 MANUFACTURER COOL INDUSTRIES
1. AIR COOLER SHALL BE OUTDOOR INSTALLATION (LOCATED
MATERIALS (Plate/Frame) SS316L/CS+COATED POWER 1.5 kW MATERIALS SS316L MATERIALS SS316 CAPACITY 70 Ltr MATERIAL TUBES/FIN COPPER / ALUMINUM OVERHEAD OF 40FT. CONTAINER).
OPERATING FLOW/DUTY 79.65m3/hr/454.3 KW DESIGN PRESSURE 11/45 barg OPERATING FLOW/HEAD 60.31m3/hr/40m DESIGN PRESSURE 10 barg MATERIAL CASING GALVANIZED STEEL 2. MAINTAIN DE-IONIZED WATER LEVEL IN STACK WHEN NOT IN
DESIGN PRESSURE 16 barg ITEM/PACKAGE TAG T-402 DESIGN TEMPERATURE 80 °C DESIGN PRESSURE 15 barg DESIGN TEMPERATURE 60 °C DUTY 481.9 KW USE.
DESIGN TEMPERATURE -20 / 110 °C DESCRIPTION MOBILE RECEIVER TOTAL CELL 129 DESIGN TEMPERATURE 100 °C DESIGN PRESSURE 10 barg 3. ALL PIPING FOR OXYGEN SERVICE SHALL BE OXYGEN-CLEANED
CURRENT (MIN/MAX) 375/3750 Amps DESIGN TEMPERATURE 90 °C (OIL-FREE) AND PASSIVATED.
MATERIALS SS304
4. NITROGEN BUFFER VOLUME TO ENSURE COMPLETE FLUSHING
ITEM/PACKAGE TAG ST-201 CAPACITY 20 Ltr VOLTS (MIN/MAX) 1.99-2.40 (BOL/EOL) each cell OF CATHODE SIDE SECTION TO PREVENT DRY STACK IN EVENT
DESCRIPTION STRAINER (Y-TYPE) DESIGN PRESSURE ATM OF OVERALL POWER/CONTROL LOSS (BOTTLE WILL ENSURE
MATERIALS SS316L DESIGN TEMPERATURE AMB FLOW OF 15-30LPM FOR 30-60 SEC.)
MESH SIZE 40 MICRON FILTER 5. AT LEAST 25 LITER PIPE VOLUME AVAILABLE TO FLOW DOWN
DESIGN PRESSURE 15 barg TO STACK (IN SHUTDOWN)
DESIGN TEMPERATURE 90 °C FAN-201 6. QUICK CONNECTION FOR MANUAL NITROGEN FLUSHING FOR
MAINTENANCE (WITH FLEXIBLE HOSE)

CONTINUED FROM P106088-PC-PID-001 STACK VENTILATION CONTINUED FROM P106088-PC-PID-003


7. 8 MM INSULATION THICKNESS TO BE CONSIDERED FOR ALL THE
INSULATED LINES.
8. OPERATOR HAVE TO STUDY THE INSTALLATION AND
40 FT. CONTAINER H2 HH=1% v/V (25% LEL) OPERATING MANUAL PRIOR TO DURING START-UP AND
AIT XA COMMISSIONING OPERATIONS OF THE STACK. (REFER TO DOC.
NO P106088-PC-IOM-001 FOR DETAILS).
305 305
H HH=80 °C HH=10°C NOTE 14 9. THE PORTION OF LINES BETWEEN TWO CONTAINERS (EXPOSED
TE TT TI TE TT TI DTI TO ATM) SHALL BE HEAT TRACED & INSULATED.
MZ 10.DURING DE-ENERGISE THE STACK, NITROGEN FLUSING WILL
203 203 203 INST. 202 202 202 202 M FS FALL
INST. F201 VENTILATION START & WILL PASS THROUGH TO STACK NOZZLE N4 TO
TO ANODE PIPING 204 204 L REMOVE THE H2 FROM STACK.
PIPING
SEPARATOR V-201 H2 LL=4500 Nm3/hr 11. CV-301 AND CV-302 INDIVIDUAL PRESSURE DROP SHALL BE
4"-O2-203-1SS150-NI 1/2" 1/2" NOTE 5 4 barg BELOW 60MBAR AT RATED FLOW, E.G. CRACK PRESSURE ≤
NOTE 3
P106088-PC-PID-001 60MBAR AND CV VALUE ≥ 1.7
CONDUCTIVITY 11 barg (A)
1/2" HH=75 °C (C) SDVS 12. CV-501 AND CV-503 INDIVIDUAL PRESSURE DROP SHALL BE
HH=11barg HH=0.2 μS/cm 100x80 HH=44barg
11 barg 45 barg 301 BELOW 30MBAR, E.G. CRACK PRESSURE ≤ 30MBAR.

1/2''-UPW-217-1SSTA-NI
PI TI FALL XA H H PI HH=80 °C 13.MAXIMUM INLET NITROGEN PRESSURE IS CONSIDERED AS 20
203 205 201 203 305 TT TI BARG.
N2 7/8"x3/4"
L 14.HIGH SENSITIVITY DETECTOR TO DETECT LEAKAGES WHILST
RO 301 301
LL=30 m3/hr VENTILATION.

226
202 NOTE 10
N4
PT TT TE FS AIT ANODE PT TE
203 205 205 INST. 201 203 SDV 305 301
INST. INST. 301 INST. TO CATHODE
N2 RELEASE TO H2 VENT PIPING 15 barg 11 barg
3/4''-N2-508-2SSTB-NI
PIPING 1/2" PIPING 1/2" 7/8"x3/4" 1/2" TUBING SEPARATOR V-301 HOLDS:
P106088-PC-PID-003 1/2" 1/2"
N1 N3 P106088-PC-PID-003
4"-UPW-210-1SS150-NI 4"x3" FC 3/4"x1" 1" 1" 1. SIGNAL EXCHANGE BETWEEN PACKAGES AND LCP WILL BE
3/4" 1"-H2-301-1SSTC-NI CV-301 CV-302 CONFIRMED DURING DETAIL ENGINEERING.
PSV
SET @
10 BARG
ELX-001 SDV-301 FH-02 2. DELETED.
CONTINUED FROM 3. DELETED.
P106088-PC-PID-001
502
STACK 4. DELETED.

1/2"x3/4" W 1/2"
TP BV-503
CATHODE 1/2"
VENT TO 007
SAFE LOCATION CV-505
1/2"-N2-504-2SSTA-NI NOTE 2, 8
NITROGEN VENT NOTE 6 INLET CONNECTOR
OUTLET CONNECTOR HH=9barg FOR FLEXIBLE HOSE
SET @ FOR FLEXIBLE HOSE
10 BARG PI NOTE 6
PALL
502
501 PSV SDVS LL=6barg SDVS
LL=6barg 501 502 SET @
BV-507 4.7 BARG 503
NOTE 13 SET @ BV-501 HH=1% v/V
1/2" PT H2
PS 7 BARG 1/2"
TP PCV SDV 502 PCV SDV AIT XA
INST. 501 BV-502
005 501 502 INST. 502 503 307 307
PIPING 1/2"
NITROGEN PIPING 1/2"
1/2" NV-503 1/2" W
1/2"-N2-501-2SSTA-NI 1/2" 1/2''-N2-510-2SSTA-NI 1/2" 1/2" 1/2" 1/2"-N2-502-1SSTA-W
CUSTOMER
NV-501 FO CV-501 FH-01 FC CV-503 1/2"-N2-505-2SSTA-NI FO FO CV-504
NOTE 12 NOTE 12
V-501 2SSTA 1SSTA MIN.
PRESSURE REDUCING NOTE 4
STATION
NITROGEN TO
NITROGEN TO V-201 V-301 VENT
1/2"-N2-503-2SSTA-NI 1/2"-N2-506-2SSTA-NI
P106088-PC-PID-001 P106088-PC-PID-003
TERMINATION POINT
SET @
DTC 4°C dT TP DESCRIPTION SIZE
204 COOLING RETURN
E&I AREA TP005 NITROGEN (NOTE 13) 1/2" O.D BULKHEAD
1 1/2"-CL-405-2SS150-NI
P106088-PC-PID-003 TP007 PSV OUTLET 1/2" O.D BULKHEAD
TO ANODE PUMP P-201 H
FIC FT
P106088-PC-PID-001 PIPING INSTR.
202 202
I/P H
L
FY FIC SET @ FT
COOLING TO
203 203 1.126 m3/hr 203 1"-UPW-213-1SSTC-NI TE TT E&I AREA
L 204 204 1 1/2"-CL-404-2SS150-NI
1/2" FI
//

FCV PIPING P106088-PC-PID-003


NOTE 9 203 401 GL-401
TUBING
TO WATER POLISHING
1/2"
1"-UPW-214-1SSTC-NI BV-207 REFERENCE DOCUMENT
P106088-PC-PID-001 1/2"
FC BV-407 P106088-PC-PFD-001 & 002 PROCESS FLOW DIAGRAM
3"-CL-403-2SS150-NI P106088-PC-EQP-001 EQUIPMENT LIST
ST-201

P106088-PC-BOD-001 BASIS OF DESIGN


2SS150 1SS150 4"-UPW-209-1SS150-NI RO
401
4"

ALLAGASH_MANUAL_REV18.6 STACK MANUAL


4"x3" 4"
H
1 1/2"-CL-414-2SS150-NI 1 1/2"-CL-413-2SS150-NI
T-402 LEGEND SHEET PLUG POWER 10 x 1MW
SET @
4" N3 N2 1SS150 2SS150 TIC
HH=2.4barg SET @ THERMAL EXPANSION/LEAKAGE
MOBILE FOR 14.12
403 65°C PSV C HLB MKu AKU KSI SDo
FROM ANODE PUMP P-201
4"x3"
L
PI 6 BAR(G)
401 RECEIVER APPROVAL
FOR
2022
15.06
4"-UPW-202-1SS150-NI 402 1/2"-CL-410-2SSTA-NI B APPROVAL 2022 HLB MKu AKU KSI VRD
P106088-PC-PID-001 LL=0.4barg FOR 14.03
4" N1 N4 A APPROVAL 2022 HLB MKu AKU KSI VRD
ET-401 MZ
1/2"-CL-406-2SSTA-NI
FOR 21.12
EXPANSION VESSEL P401
3"-CL-416-2SS150-NI
O APPROVAL 2021 HLB MKu AKU KSI VRD
3"-CL-407-2SS150-NI TCV PRECHARGED
PIT PG PIPING INST. Description
Check Check Check Appr.
403 NORMAL P_LOOP= 2 BAR(G) Rev. Date Drawn
HX-201 I/P
TY
402 405 3"-CL-401-2SS150-NI 3"-CL-402-2SS150-NI TCV Proc. Mech. Instr.

FO // 401
ANODE HEAT EXCHANGER 3" 403 INST.
BV-403
TE CUSTOMER : PLUG POWER
INST. PIPING 401 CUSTOMER REF. : PO134440
1/2" 3" 1/2"
PIPING M
PLUG REF. : P106088
1/2"
BV-404 3" AC-401 NOTE 1 TT PROJECT : PLUG POWER 10x1 MW
1/2" N1 N2
3" 2" 3"x2" BV-401
1/2" AIR COOLER REGULATING
401
BV-402 3-WAY VALVE TM
P.O. Box 15
SET @ 29 C (CRACK OPEN) Alphen aan den Rijn
BV-406 3" 41 C (FULL OPEN) The Netherlands
1/2"
3"-CL-408-2SS150-NI BV-405 TT It is forbidden to copy or use in whole or in part outside the strict
402 H contract terms, without the prior written consent of a Plug Power company.
P-401 AC-401 POWER TIC SET @ Title:
M DISTRIBUTION
COOLANT PUMP HH=80 °C
PANEL 401 45°C PIPING AND INSTRUMENT DIAGRAM
PLUG POWER 10x1 MW
(HIGH TEMP) TAHH
402 STACK & COOLANT CIRCULATION LOOP
TYP. DETAIL 2
MXA MXV
OUTSIDE AC-401 AC-401
Drwg.No.:
Scale: NTS
CONTINUED FROM P106088-PC-PID-001 CONTINUED FROM P106088-PC-PID-003
(TOP OF CONTAINER) P106088-PC-PID-002 Size: A1
ITEM/PACKAGE TAG V-301 ITEM/PACKAGE TAG FAN-301 ITEM/PACKAGE TAG CH-101 ITEM/PACKAGE TAG SP-101 ITEM/PACKAGE TAG SP-102 NOTES:
DESCRIPTION CATHODE SEPARATOR DESCRIPTION VENTILATION FAN DESCRIPTION CHILLER UNIT DESCRIPTION SPACE HEATER DESCRIPTION SPACE HEATER
MANUFACTURER ALPHA ECC FLOW RATE 4000 @ 340 Pa m3/hr DESIGN CAPACITY 33.5 kW POWER 2 kW POWER 2 kW
1. INLET SHALL BE PROVIDED WITH HALF PIPE INLET OPENING
MATERIALS SS316L POWER 1.5 kW CHILLER MEDIUM ETHYLLENE GLYCOL DOWNWARD.
SIZE Ø346x1500 mm CHILLER INLET/ 2. OXYGEN AND HYDROGEN VENTS SHALL BE SEPARATED 2
DESIGN PRESSURE -0.5 / 45 barg OUTLET TEMPERATURE 20/30 °C METERS HORIZONTALLY.
VENT TO
DESIGN TEMPERATURE -20 / 90 °C FANS 2 NOS. 3. STACK POWER SUPPLY SHALL GET DISCONNECTED WHEN ONLY
SAFE LOCATION
40 FEET CONTAINER DOOR IS OPENED WHILE THE UNIT IS IN
1/2"-N2-506-2SSTA-NI OPERATION.
40 FT. CONTAINER 4. RO IS SIZED IN SUCH A WAY THAT DEPRESSURIZATION OF

3"-H2-316-1SS600-WT
ESD XA CATHODE SECTION IS SLOWER THAN DEPRESSURIZATION OF
1/2"-N2-507-2SSTA-NI 10 BARG
301 301 ANODE SECTION.
45 BARG
5. CHILLER SHALL BE INSTALLED OUTDOOR.
CONTINUED FROM P106088-PC-PID-002 1/2" SET @ 6. CONNECTION FOR MANUAL NITROGEN FLUSHING FOR
RO CV-507 PCV
0 BARG NOTE 2 MAINTENANCE (WITH FLEXIBLE HOSE).
301 TP
504 7. 8 MM INSULATION THICKNESS TO BE CONSIDERED FOR ALL THE
FAN-301 006

CV-303
INSULATED LINES.

CV-304
TUBING PIPING (45 BARG)
ON/OFF 8. TO BE USED TO DIVERT V-301 WATER DURING FIRST 24 HOUR
CONTAINER VENTILATION

1"
1"
(TRACING) OF STACK LIFE (CONTAMINATED WATER)
MZ TIC TT 3"-H2-305-1SS600-NI
M AMBIENT TEMP. 9. DELETED.
F301 305 305 MEASUREMENT 10. VISIBLE ALARMS TO BE GENERATED AT 23.5% OXYGEN IN AIR
FROM NITROGEN SUPPLY NOTE 4 1"x3"
CONCENTRATION.
1/2"-N2-506-2SSTA-NI 1"-H2-330-1SS600-NI 1"-H2-319-1SS600-NI CONTINUED FROM
P106088-PC-PID-002 11. CONDENSATE TRAP TO BE PLACED AS LOW AS POSSIBLE.
1/2"-H2-315-1SSTA-NI P106088-PC-PID-004 12.FEED-THROUGH CONNECTION TO GET FLEXIBLE HOSE TO
SDV
1/2''-H2-318-1SSTA-NI NITROGEN TO DEOXO VENT OUTSIDE, FOR INSTANCE TO CONNECT TO BV-303 OUTLET.
302
13.ESD BUTTONS A/B/C (C IN UTILITY CONTAINER) LOOPED INTO
SDVS P106088-PC-PID-004 ONE SIGNAL.
FO 14.FLOOR DRAIN.
302 CT-301
RELEASED N2 BOTTLE V-501 1/2" 15.IN OUTLET PRESSURE CONTROL MODE, DOWNSTREAM
3/4''-N2-508-2SSTB-NI 1/2''-H2-325-1SSTA-NI CONDENSATE TRAP TO DRAIN (BUFFER) PRESSURE IS USED AS INPUT TO CURRENT
P106088-PC-PID-002 NOTE 11 CONTROLLER. IN CURRENT CONTROL MODE, USER TO DEFINE
SET @ P106088-PC-PID-004 INPUT CURRENT LEVEL.
PSV
45 barg 1/2"-RE-331-1SSTA-NI 16.GRAVITY SHUTTERS FOR VENTILATION, EQUIPPED WITH A 10
301 FROM DRYER MICROMETER FILTER.
1/2"x1 1/2" 1 1/2"-H2-310-1SS600-NI
O2 HH=23.5% v/V PSV VENT
AIT XA NOTE 10 2"-H2-313-1SS600-NI
P106088-PC-PID-004
202 202 SDVS
H
LL=19.5% v/V 1/2"x3/4" 303 FROM DRYER
TI TT TE
H2 H2 VENT
HH=1% v/V (25% LEL) 302 302 302
1"-H2-329-1SS600-NI HOLDS:
AIT XA L P106088-PC-PID-004
INST. SDV
306 306
1/2" TUBING 303 TO DRYER PACKAGE 1. DELETED.
3/4"-H2-303-1SSTB-NI FH-03 3/4"-H2-304-1SSTB-NI 2. DELETED.
P106088-PC-PID-004 3. DELETED.
HH=46 °C FC 4. DELETED.
TT TI
3/4"-H2-309-1SSTB-NI

AMBIENT TEMPERATURE 3/4" 5. DELETED.


304 304 MEASUREMENT
1/2" 1/2"
LL=-20 °C CONNECTOR FOR CV-506 BV-504
FLEXIBLE HOSE INLET TO PC DRYER PACKAGE
PT NOTE9
P106088-PC-PID-004
XL XS 302
EMERGENCY FLASHER
304 304 LAMP (RED FLASHING) RESET BREAKER PSD TRIP INLINE COOLER HX-202
E & I AREA INSIDE 1"-CL-411-2SSTC-NI
P106088-PC-PID-001
STACK IN OPERATION XR XR XZ
INST.
XL
305
XS
305
FLASHER LAMP
(AMBER FLASHING) TUBING
40 FT CONTAINER 011A 011B 020 FROM
DRYER PACKAGE
1"-CL-412-2SSTC-NI
REMOTE REMOTE RUNNING GENERAL P106088-PC-PID-004
PSD SIGNAL ESD SIGNAL ESD TRIP START/RUN FEEDBACK FAULT
N4 N5
H
ESD XA 3/4" 1/2"
NOTE 13 XZ XZ XZ XR XY XY TE TT TI
302A/B 301 001 005 010 011C 016 017 404 404 404

ZSO XA DOORS (4X) N2 INST.


303 303 NOTE 3 3/4"
INST. TUBING TUBING
1/2"
HH=44 barg KEY LOCAL CONTROL RCP-001 1"-CL-409-2SSTC-NI
OVERRIDE
PI PIT N10 DOORSWITCH PANEL LCP-001 RECTIFIER CONTROL PANEL
301 301 1/2" HH=700mm
LL=30 barg LAHH HS NOTE 5
TUBING PIPING 301 303 GENERAL
TERMINATION POINT
T/R COMMI-
ESD LCP LOSS OF SSIONING COMMU- CURRENT VOLTAGE FAULT TP DESCRIPTION SIZE
FROM STACK ELX-001

TUBING
PUSH INTERNAL POWER MODE SOFT NICATION
1"-H2-301-1SSTC-W N1 BUTTON FAILURE SUPPLY SIGNAL LOSS XI

INST.
P106088-PC-PID-002 IIT EIT 3" 600# HEADER WITH
1 1/2" 013 015 110 TP006 VENT TO SAFE LOCATION
6" OD VENT PIPE
NOTE 1 LS XZ ESD XZ XZ XZ XZ
N6
301 008 001 002 003 009 004 CONTAMINATED DRAIN
1" TP010 1" 150#
(NOTE 8 & 12)

FLOOR DRAIN CONTROL


TUBING INST. TP011 1" 150#
ROOM
V-301 1"-CL-415-2SSTC-NI CH-101
N7A TP013A/B FLOOR DRAINS 1" 150#
NOTE 12
CATHODE SEPARATOR HHLL
HLL
+700 MM
+600 MM
3"
OPERATING
REMOTE
CURRENT
CHILLER PACKAGE
H MODE SETTING HH HH
NLL
LLL
+350 MM
+250 MM LT LIC SET @
II
H
EI TE (INCL PUMP)
XI XI XI 013 015 405
LLLL +150 MM 301 301 350 mm L
005 006 007 LL LL REFERENCE DOCUMENT
DP TYPE L
LLL TT P106088-PC-PFD-001 & 002 PROCESS FLOW DIAGRAM
HEARTBEAT
405 OUTSIDE AIR
N7B COUNTER P106088-PC-EQP-001 EQUIPMENT LIST
TS 3" EIC P106088-PC-BOD-001 BASIS OF DESIGN
101
CURRENT IIC 014
LS LALL HH
N8 CONTROL 012
VOLTAGE TI SET @ ALLAGASH_MANUAL_REV18.6 STACK MANUAL
SP-101 1" 302 302
LL=150mm
NOTE 15 CONTROL 405 30 °C LEGEND SHEET PLUG POWER 10 x 1MW
SPACE HEATER 3/4" TP
FOR 14.12
N3 011 C HLB MKu AKU KSI SDo
HEATER WITH INTEGRATED THERMOSTAT TUBING INST. APPROVAL 2022
NOTE 14 FOR 15.06
B APPROVAL 2022 HLB MKu AKU KSI VRD
FOR 14.03
COOLING MEDIUM A APPROVAL 2022 HLB MKu AKU KSI VRD
SYSTEM FROM COOLING CIRCUIT FOR 21.12
TS XY EFFICIENCY
1 1/2"-CL-404-2SS150-NI O APPROVAL 2021 HLB MKu AKU KSI VRD
018 CALCULATOR P106088-PC-PID-002
102 I/P Rev. Description Date Drawn
Check Check Check Appr.
L Proc. Mech. Instr.
LY
3/4"-UPW-307-1SSTB-NI

301
SP-102 COOLING MEDIUM
RETURN TO COOLING CIRCUIT
CUSTOMER : PLUG POWER
SDVS ATM CUSTOMER REF. : PO134440
SPACE HEATER 1 1/2"-CL-405-2SS150-NI
//

304 4 BARG AV-301 P106088-PC-PID-002 PLUG REF. : P106088


HEATER WITH INTEGRATED THERMOSTAT AUTOVENT
FROM FIC-301 PROJECT : PLUG POWER 10x1 MW
//

P106088-PC-PID-004 TM
P.O. Box 15
SDV LCV
1/2''-H2-327-1SSTA-NI Alphen aan den Rijn
304 301 The Netherlands
TO ANODE SEPARATOR V-201
CV-311 CV-312 3/4"x2" 2"x3/4"
3/4"-UPW-308-1SSTB-NI It is forbidden to copy or use in whole or in part outside the strict
P106088-PC-PID-001 contract terms, without the prior written consent of a Plug Power company.
FC FC 3/4" 3/4" 2''-UPW-321-1SS150-NI
1/2" 1/2" Title:
BV-301 BV-303 >500mm
FROM PIC-304 PIPING AND INSTRUMENT DIAGRAM
NOTE 8 45 barg 4 barg
PLUG POWER 10x1 MW
P106088-PC-PID-004
CATHODE SEPARATOR AND E&I AREA
NOTE 16

Drwg.No.:
CONTINUED ON P106088-PC-PID-002 CONTINUED ON P106088-PC-PID-004
Scale: NTS
TP TP TP
NOTE 14 013A NOTE 14 013B NOTE 12 010
P106088-PC-PID-003 Size: A1
ITEM/PACKAGE TAG V-601 ITEM/PACKAGE TAG V-602A/B ITEM/PACKAGE TAG HX-601 ITEM/PACKAGE TAG HX-603 ITEM/PACKAGE TAG F-601A/B, F-602A/B/C/D 10 BARG 45 BARG NOTES:
DESCRIPTION DEOXIDIZER DESCRIPTION DRYER A/B DESCRIPTION GAS COOLER DESCRIPTION COOLER DESCRIPTION CONDENSATE FILTER PCV SET @
1/2" 505 0 BARG
MANUFACTURER AQUAGAS MANUFACTURER AQUAGAS MANUFACTURER AQUAGAS MANUFACTURER AQUAGAS MANUFACTURER AQUAGAS 1. AUTOMATIC CONDENSATE TRAPS.
CV-508
MATERIALS CS MATERIALS CS MATERIALS SS316L MATERIALS SS316L MATERIALS SS 2. TEMPERATURE CONTROL OF V-601, V-602A & V-602B SHALL BE
TO XY-018 ACCOMPLISHED VIA RESPECTIVE TEMPERATURE
SIZE 220 x 1560 mm SIZE 170 x 1560 mm DESIGN PRESSURE 45 barg DESIGN PRESSURE 45 barg DESIGN PRESSURE 45 barg
P106088-PC-PID-003 TRANSMITTERS.
DESIGN PRESSURE 45 barg DESIGN PRESSURE 45 barg DESIGN TEMPERATURE 250 °C DESIGN TEMPERATURE 250 °C DESIGN TEMPERATURE 250 °C
TUBING PIPING 3. CORIOLIS FLOWMETER F-301 INSTALLED HORIZONTALLY UPSIDE
DESIGN TEMPERATURE 250 °C DESIGN TEMPERATURE 250 °C RO DOWN (GAS SERVICE) WITH 10 D UPSTREAM & 5D DOWNSTREAM
1SSTA 1SS600 1''-H2-329-1SS600-NI
302 STRAIGHT LENGTH.
ITEM/PACKAGE TAG HX-602 ITEM/PACKAGE TAG F-603 TO H2 VENT 4. DE-OXIDIZER AND DRYER ARE PART OF VENDOR PACKAGE.
1" 1"
DESCRIPTION ELECTRIC HEATER DESCRIPTION CARBON FILTER 1"-H2-306-1SS600-NI 5. ALL DRAINS ROUTED TO LOWEST POINT OF ENCLOSURE.
P106088-PC-PID-003 6. CONNECTIONS:
MANUFACTURER AQUAGAS MANUFACTURER AQUAGAS 1/2''-H2-323-1SSTA-NI CV-305 CV-306
FROM PT-302 GAS INLET/OUTLET: 16mm TUBE CONNECTOR
MATERIALS SS MATERIALS SS SVDS SDV CONNECTION COOLING WATER IN/OUT: 18mm TUBE
ON/OFF HH 80°C
DUTY 4.5 KW DESIGN PRESSURE 45 barg 608 H2 DEWPOINT P106088-PC-PID-003 CONNECTOR

1/2''-H2-324-1SSTA-NI
TI H 40°C 305
DESIGN PRESSURE 45 barg DESIGN TEMPERATURE 250 °C H= -38C @30 barg/5ppmv CONNECTION CONDENSATE TRAP OUTLET: 8mm TUBE
303 O2 IN H2
DESIGN TEMPERATURE -20 / 450 °C AA SDVS 1/2" H CONNECTOR
SOV PIC SET @ =5 PPM SAMPLE
601 ZSO 305 FO AA AIT TO SAFETY VALVE: 12mm TUBE CONNECTOR
608 302 41 barg PANEL
NOTE 11 308 308 7. HEAT TRACING APPLICABLE FOR DEXO AND DRYER VESSEL
CONTINUED FROM P106088-PC-PID-003 SET @ S 608B H
FROM NITROGEN SUPPLY 40 FT. CONTAINER 45 barg
I/A // // //
PI
TT DT FIC
L
NOTE 8 PIC SET @
TO IIC-012 AND SHALL NOT BE MORE THAN 250 °C.
8. CONTROLLER UTILIZED TO ADJUST PRODUCTION CONTROL
I/P P106088-PC-PID-002
1/2"-N2-506-2SSTA-NI PSV 64.1 303 304 40 barg (STACK CURRENT) BASED ON DOWNSTREAM PRESSURE, TO
P106088-PC-PID-003 64-V66 XV 301 301 PY 1/4''-H2-326-1SSTY-NI

//

//
302 XV L KEEP DOWNSTREAM H2 BUFFER PRESSURE CONSTANT.
AIT 608B L 302 SDVS INST. 9. 8 MM INSULATION THICKNESS TO BE CONSIDERED FOR ALL THE
TO H2 VENT 608A PG TE
ZSO 601 SDV 307 TUBING INSULATED LINES.
2"-H2-313-1SS600-NI 1/2"x2" 601 303 PT

//
P106088-PC-PID-003 608A 306 10. CV-309 & CV-310 INDIVIDUAL PRESSURE DROP SHALL BE BELOW
INST. FT TP
3/4"-H2-314-1SSTB-NI PCV 304 100 MBAR AT RATED FLOW E.G CRACK PRESSURE <=100 MBAR &
1 1/2''-H2-317-1SS600-NI 301 1/2" SDVS SDV
FC FC TUBING 008 CV VALUE.=1.2
1/2"x3/4" 66-V1 BV-610 302 FO 306
66-V1 1/2" 307 TO H2 HEADER 11.DENSITY MEASUREMENT TO INDICATE H2 PRODUCT PURITY.
64-V9 1/2"
12. SOV-603 (64-V2) & SOV-604 (64-V1) VALVES ASSUME TO BE

SET @
DRYER PACKAGE DX-601 16mm 3/4"-H2-311-1SSTB-NI
C
FC FC 3/4" 3/4" 3/4"
CUSTOMER OPERATED BASED ON STEP 1 OF DRYER PACKAGE FACILITY.
13. SKIN TEMPERATURE MEASUREMENT HARDWIRED TO ON/OFF
45 barg NOTE 4, 6
SDVS
64.1 NOTE 3 3/4" BV-302 CV-309 CV-310 TO HYDROGEN BUFFER THERMOSTAT TO STOP HEAT INPUT.
3/4"-H2-312-1SSTB-NI NOTE 10
603
ON/OFF F-603
PSV SOV
303 603 PARTICLE FILTER GS ZSC
S NOTE 12 64.1.2 604B
1/2"x1 1/2" I/A // // // // // // // // // // // // // // // // // // // //
// // // // // // // // // // // // // // // // // // // // // // // // // // // //
64-V2

//
HOLDS:

//
1/2"x3/4" SDVS
// // // // // // // // // // // // // // // // // //

//
604 ON/OFF XV
GS ZSC XV
HH SET @ 250 °C 604B 1. DELETED.
64.1.1 604A

//
//

//
SOV 604A 2. DELETED.

//

//
TI TI
61.1 603 604 3. DELETED.
H

//
S NOTE 12 64-V4.1 FC TI TI

//
//

//
//
I/A //
//
// // // // // // // // // //
64-V4.2
607B 64.8

//
TT TT 64-V1 XV XV
TT GS ZSC GS ZSC L
61.1 603 64.6 604C 603B
64.1.3 603A 64.1.4 603B

//
H
3/4''-H2-320-1SSTB-NI

16mm-H2-314-1SSTX-NI 64-V4.3
TI TT

//
TT TT
607A 607A NOTE 2, 7 HH FC 64-V4.4 NOTE 2, 7 607B 64.8
NOTE 2, 7 L TAHH NOTE 13

//
HH=250 °C TI 609
61 TI TI 64.6 ON/OFF
TS HH

//
602 60.2
V-601 NOTE 2, 7 MZ
TS
609
TS 64.2 TAHH TAHH I/P
XV SOV SDVS
602
602 602
HX602 601 601 64.2 FC

//
FY
DEOXIDIZER 403 64.1 S
TT TT FC
// //
// I/A
HE-64.1

//
602 60.2 64-V7
HE 61.1 MCC 64-V3
HH
HX-602

//
EHT-601 TS TAHH SDVS ZSO GS 64B
608 608 NOTE 13
ELECTRIC 601 602 64.3

//
TIC TS
DEOXOHEATER V-602B
TT TIC TI
604 604
HEATER SOV

//
60.1
59-T1
601 601
L SET @ 16 MM 64-V14.1 S
601
DRYER B
TT

//
60 °C
//
// I/A
60.1 BV-603
HX-601 ON 65°C 64-V14
XV
64-V8 FCV E-601 64-T4
OFF 60°C
64A 601

//
MCC TERMINATION POINT

//
601
GAS COOLER EJECTOR
V-602A
// // // // // //
FROM CATHODE FC

//
TP DESCRIPTION SIZE
SEPARATOR V-301
MZ DRYER A FO
TP008 H2 HEADER 3/4"-O.D. BULKHEAD

//
P106088-PC-PID-003 ZSO GS 64-V6
EHT601 601 64.2 64-T1 TP009 REJECT WATER 1/2" O.D BULKHEAD

//
3/4"-H2-304-1SSTB-NI

HX-603

//
H H
TT TI TT TI
COOLER

//
606A 606A 606B 606B
16 MM L L 16 MM
BV-605 TT TI TT TI BV-607

//
16 MM 64.5 64.5 64.7 64.7
64-V10 NC NC 64-V11
16mm-H2-328-1SSTX-NI

BV-601 // // // // // // // // // // // // // // // // // // //
NC

//
61-V1 CONDENSATE FILTER ZSO CONDENSATE FILTER REFERENCE DOCUMENT

//
64-V15 F-602A F-602C 605
GBV-602
F-602D F-602B P106088-PC-PFD-001 & 002 PROCESS FLOW DIAGRAM
16 MM P106088-PC-EQP-001 EQUIPMENT LIST
64-F1.1 64-F1.2 64-F2.2 64-F2.1

//
BV-604 64-V30 16 MM
OPEN - B P106088-PC-BOD-001 BASIS OF DESIGN
BV-606
GBV-601 16 MM OPEN - A 64-V16
59-V1 BV-602
ALLAGASH_MANUAL_REV18.6 STACK MANUAL
61-V2 64-V13
ON/OFF LEGEND SHEET PLUG POWER 10 x 1MW
XV
1"-CL-412-2SSTC-NI CONDENSATE FILTER SDVS
606
SOV
16 MM
605
16 MM C
FOR 14.12
HLB MKu AKU KSI SDo
606 SDVS APPROVAL 2022
TO CHILLER CH-101 BV-612 BV-613
18 MM
F-601A F-601B S 64-V32 66-V33 607
ON/OFF B
FOR
APPROVAL
15.06
2022 HLB MKu AKU KSI VRD
P106088-PC-PID-003 I/A //
// //

61-F1.1 61-F1.2 XV A
FOR 14.03
HLB MKu AKU KSI VRD
//

64-V17 SOV APPROVAL 2022


FROM INLINE RO 1.0 MM 607 FOR 21.12
64-T2 607
COOLER HX-202
O-DEOXO O-DRYER O APPROVAL 2021 HLB MKu AKU KSI VRD
601 S
18 MM 64-V12 Check Check Check Appr.
Rev. Description Date Drawn
P106088-PC-PID-001 H FC
// //
// I/A Proc. Mech. Instr.
LO 66-V31 64-1 66-V12
PI PT
XV
1"-CL-417-2SSTC-NI 61-V3 602 602 CUSTOMER : PLUG POWER
606
16 MM L CUSTOMER REF. : PO134440
BV-611 RO 1.2 MM PLUG REF. : P106088
ZSC GS
602 PROJECT : PLUG POWER 10x1 MW
607 64-T2
FROM O2 CONDENSATE TRAP
1/2''-RE-225-1SSTA-NI TM
P.O. Box 15
P106088-PC-PID-001 Alphen aan den Rijn
The Netherlands
W It is forbidden to copy or use in whole or in part outside the strict
1/2"-RE-322-1SSTA-W
contract terms, without the prior written consent of a Plug Power company.
Title:
1/2"-RE-108-2SSTA-NI
PIPING AND INSTRUMENT DIAGRAM
TP PLUG POWER 10x1 MW
FROM H2 CONDENSATE TRAP
009 DRYER PACKAGE
P106088-PC-PID-003 TO REJECT WATER
1/2''-RE-331-1SSTA-NI
CUSTOMER
Drwg.No.:
Scale: NTS
CONTINUED FROM P106088-PC-PID-003 P106088-PC-PID-004 Size: A1
V-201 NOTE A ANODE SEPARATOR ITEM/PACKAGE TAG SP-201 NOTES:
DESIGN PRESSURE -0.5 / 4 barg DESCRIPTION SPACE HEATER
DESIGN TEMPERATURE -20 / 90 °C POWER 140 W 1. INLET IN TOP OF HEADER
OPERATING PRESSURE 0.7 barg
OPERATING TEMPERATURE 70 °C
SIZE ID x TT 938 x 1700 mm
MATERIAL SS316L

1/4" 1/4"-O2-220-1SSTX-WT
GENERAL NOTES:
CV-203
A. DELETED.

NOTE 1 TO VENT

W
0 BAR(G)

HOLDS:
H2 in O2
BREATHER
ANALYSER CABINET

H2
HH=1% H2 IN O2 (25% LEL)
AIT XA H=0.9%
201 201

FILTER 7 MICRON
F-202

FS-205
FI
1-1/2"-O2-211-1SS16-NI

SP-201 FS FALL
RO 205 205
201
CABINET HEATER LL = 80 CC / MIN

1/4"
SDVS NV-201
1-1/2"x1" H2 in O2 ANALYZER SYSTEM
201 BREATHER

I/P
PY
// // FO 1-1/2"
202
FO
PCV 1-1/2"x1"
202 SDV
201 (TRACING)
W COOLING LIQUID RETURN
1"-CL-417-2SSTC-NI
1-1/2''-O2-204-1SS16P-NI

H
PIC SET @
202 0.7 barg 1/2"-O2-221-1SSTA-NI HX-202
L 1/2"-O2-212-1SSTA-NI INLINE COOLER

1/4"-O2-218-1SSTX-WT
PT PG
202 202

COOLING LIQUID
(FROM CHILLER)
N5A 1"-CL-411-2SSTC-NI
INST. 1-1/2" MAX 20 C
TUBING

N4 N5
1/2"
6"

FOR 14.12
B APPROVAL 2022 HLB MKu AKU KSI SDo
FOR 15.06
CT-202 A APPROVAL 2022 HLB MKu AKU KSI VRD
CONDENSATE FOR 14.03
O APPROVAL 2022 HLB MKu AKU KSI VRD
TRAP
Check Check Check Appr.
Rev. Description Date Drawn
Proc. Mech. Instr.

TO DRAIN
CUSTOMER : PLUG POWER
1/2"-RE-219-1SSTA-W
CUSTOMER REF. : PO134440
PLUG REF. : P106088
PROJECT : PLUG POWER 10x1 MW

TM
P.O. Box 15
Alphen aan den Rijn
The Netherlands

It is forbidden to copy or use in whole or in part outside the strict


contract terms, without the prior written consent of a Plug Power company.
Title:
PIPING AND INSTRUMENT DIAGRAM
H2 IN O2 SAMPLE SYSTEM

Drwg.No.:
Scale: NTS
P106088-PC-PID-005 Size: A1