A.

GENERAL NOTES
IN THE INTERPRETATION OF THESE DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN AND DISTANCES
OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES.
THE CONTRACTOR SHALL COORDINATE WITH THE AR, ME, EE AND OTHER UTILITIES AND EQUIPMENT 3000
PLANS FOR THE EXACT SIZE, NUMBER AND LOCATIONS OF ALL SLEEVES OR OPENINGS THRU FLOOR 40 402200
SLABS, BEAMS AND WALLS AND ALSO BUILDING DIMENSIONS.
300mm X 300mm REINFORCED CONCRETE
ALL REINFORCED CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH THE ACI - 318 - 89 BUILDING
COLUMN with CONTINUOUS 4-16MM DIA.
CODE, AND ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS
(LATEST EDITION) IN SO FAR AS THEY DO NOT CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENTS. and 4-12mm DIA. MAIN BARS with 300mm
90deg. BEND and 10mm DIA. LATERAL TIES

40
ALL SLABS, BEAMS, GIRDERS AND OTHER STRUCTURAL ELEMENTS WHICH ARE NOT INDICATED, DETAILED, SPACED AS FOLLOWS:
DESIGNATED OR INADVERTENTLY OMITTED BUT ARE NECESSARY TO BE COORDINATED WITH ARCHITECTURAL

3000
3 @ 50 mm
AND OTHER ALLIED ENGINEERING PLANS AS WELL AS TO COMPLETE THE STRUCTURAL WORKS IN ACCORDANCE
WITH THE INTENT OF THE PLANS AND SPECIFICATIONS SHALL BE BROUGHT UP DURING PRE-BIDS/MEETINGS/ 3 @ 100mm

40
NEGOTIATIONS. IT IS UNDERSTOOD THAT THE CONTRACTOR HAS PROVIDED AND INCLUDED ALL THESE ITEMS 5 @ 150mm
IN THEIR BID. REST AT 200mm ON CENTERS and BOTH
WAYS.

B. NOTES ON CONCRETE MIXES AND PLACING


UNLESS OTHERWISE INDICATED IN PLANS OR NOTED IN THE SPECIFICATIONS, THE MINIMUM 28-DAYS
CYLINDER COMPRESSIVE STRENGTH OF CONCRETE f'C, SHALL BE AS FOLLOWS:
1.1 FOUNDATION 21.0 MPa (3000 psi)
COLUMN PLAN DETAILS
1.2 COLUMNS 21.0 MPa (3000 psi)
1.3 FLOOR SLABS, BEAMS & GIRDERS 21.0 MPa (3000 psi)
1.4 PARAPET WALLS AND OTHER STRUCTURAL ELEMENTS 21.0 MPa (3000 psi)
1.5 PARTITIONS, CURTAIN WALLS, BEDDEDSLABS, SIDEWALKS, 17.0 MPa (2500 psi)
CURB, GUTTER & OTHER STRUCTURAL ELEMENTS
1.6 LEAN CONCRETE 10.0 MPa (1500 psi)
1500
CONCRETE SHALL BE DEPOSITED IN ITS POSITION WITHOUT SEGREGATION, RE-HANDLING 75 1350 75
OR FLOWING. PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEEL BARROWS.
NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPERS TO BUGGIES,

75
WHEEL BARROWS OR BUCKETS, IN WHICH CASE, THEY SHALL NOT EXCEED SIX THOUSAND
(6000mm) IN AGGREGATE LENGTH.
NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS, UNLESS 1000mm x 1000mm x 250mm
AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER AND ONLY FOR UNUSUAL CONDITIONS REINFORCED CONCRETE COLUMN
WHERE VIBRATION IS EXTREMELY DIFFICULT TO ACCOMPLISH. FOOTING with 6-16mm DIA.
TEMPERATURE BARS SPACED
EQUALLY ON CENTERS EACH WAY
C. NOTES ON FOUNDATION: and 75mm x 75mm x 75mm
1. BUILDING ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 96Kpa (200Psf) AT A DEPTH OF 0.60 METER CONCRETE SPACERS, LOCATED AS
FROM LOWER GROUND FLOOR LEVEL. CONTRACTOR SHALL REPORT IN WRITING TO THE STRUCTURAL DESIGNER ON THE

1500
1350
SHOWN.
ACTUAL SOIL CONDITIONS UNCOVERED AND CONFIRM ACTUAL BEARING CAPACITY OF SOILS BEFORE DEPOSITING OF CONCRETE.

2. FOOTING FOR CHB WALLS AND OTHER MINOR STRUCTURES SHALL BE EMBEDED AT LEAST 600mm FROM THE NATURAL GRADE LINE.
3. PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION. DEWATERING SHALL BE CAREFULLY
AND PROPERLY PERFORMED TO AVOID DISTURBING THE FOUNDATIONS AND SLAB BEARING SURFACES.
4. PREPARE CONDITIONS OF CONCRETE SUPPLY AND PLACEMENT OF THE COMPLETE FOUNDATION FOR THE FULL THICKNESS
AS A CONTINUOUS MONOLITHIC CASTING.

75
D. NOTES ON MASONRY WALLS.
1. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE APPLICABLE STANDARDS AND SPECIFICATIONS
OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND UNIFORM BUILDING CODE.
2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM "LOAD BEARING BLOCKS"
COLUMN FOOTING-1 PLAN DETAILS
3. MORTAR AND GROUT FOR ALL REINFORCED MASONRY SHALL CONFORM TO ASTM 270-TYPE M AND SHALL HAVE A MINIMUM
28-DAYS STANDARD CYLINDER COMPRESSIVE OF 20.7 Mpa (3000psi)

4. ALL CELLS CONTAINING REINFORCING BARS OR INSERT SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT.

5. FOR TYPICAL CONNECTION DETAILS ON MASONRY UNITS, REFER TO DETAILS.