Column Footing and Gravel Bedding Details

The document provides details for reinforced concrete lintels, hollow concrete blocks, and column footings. It specifies dimensions and reinforcement for a 200mm x 150mm concrete lintel beam with continuous steel bars and C-clamps spaced at 200mm. 150mm concrete blocks are shown with dowel bars and mortar filling. A 200mm x 150mm concrete wall footing has continuous steel bars spaced at 150mm. Concrete spaces and gravel bedding are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views1 page

Column Footing and Gravel Bedding Details

The document provides details for reinforced concrete lintels, hollow concrete blocks, and column footings. It specifies dimensions and reinforcement for a 200mm x 150mm concrete lintel beam with continuous steel bars and C-clamps spaced at 200mm. 150mm concrete blocks are shown with dowel bars and mortar filling. A 200mm x 150mm concrete wall footing has continuous steel bars spaced at 150mm. Concrete spaces and gravel bedding are also specified.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

200mm x 150mm REINFORCED CONCRETE

LINTEL BEAM with CONTINUOUS 2-10mm


DIA. CORRUGATED REINFORCING STEEL
BARS with 10mmØ C-CLAMP SPACED AT
200mm ON CENTERS.
600 300 600
40 220 40 150mm CONCRETE HOLLOW BLOCKS with
10mmØ DOWEL BARS with 100mm 90deg.
HOOK ON TOP and BOTTOM SPACED AT
600mm ON CENTERS, EACH CORE IS
FILLED with MORTAR MIXTURE.

200mm x 150mm REINFORCED CONCRETE


WALL FOOTING with CONTINUOUS 2-12mm
DIA. CORRUGATED REINFORCING STEEL
BARS with 10mmØ C-CLAMP SPACED AT
150mm ON CENTERS.

75mm x 75mm x 75mm CONCRETE SPACES,


LOCATED AS SHOWN.
±600mm TOP OF LINTEL BEAM
200

3
100mm THK. WELL COMPACTED 4
CRUSHED GRAVEL GRAVEL BEDDING.
600
400

±0.00mm GRADE LINE


100150

1000mm x 1000mm x 250mm REINFORCED


±150mm BOTTOM OF WALL FOOTING CONCRETE COLUMN FOOTING with 6-16mm
±250mm BOTTOM OF GRAVEL BEDDING Ø TEMPERATURE BARS SPACED EQUALLY
ON CENTERS EACH WAY.
H=1000
500

75mm x 75mm x 75mm CONCRETE SPACES,


LOCATED AS SHOWN.
±750mm TOP OF COLUMN FOOTING
D=250

3
100mm THK. WELL COMPACTED 4
±1000mm BOTTOM OF COLUMN FOOTING CRUSHED GRAVEL GRAVEL BEDDING.
100

±1100mm BOTTOM OF GRAVEL BEDDING


WELL COMPACTED EXCAVATED NATURAL
GRADE LINE 99% MDD.

COLUMN FOOTING-1 SECTION ELEVATION DETAILS

COLUMN AND COLUMN FOOTING DETAILS


01-S1 NTS

100
D=250
500
150
400
200
H=1000
600
40
220
40
300
600
600
100
±600mm TOP OF LINTEL BEAM
±0.00mm GRADE LINE
±150mm BOTTOM OF