DC Exp
DC Exp
Banglore India
1.2
1.3
1.4
1.5
Same as workbook.
1.6
Copy the config from other devices like BGW1 and Dc2 N7K but ensure to edit it
correctly before pasting. don't waste time on troubleshooting
1.7
ebpg multi-hop missing on both sides. DCI Tracking missing on BGW1.
send community missed bgw1
1.8
Nothing needed here.
1.9
DCNM - Select SHA. Then MD5. It was up within in a minute.
no ip address on DCNM so take ref from BGW1
1.0
Fi-A
need to create 1/8 and 1/10
FI-B
1/9 and 1/11 and 1/12 needs config as per workbook
2.6
as per workbook
CCIE-SP-2
Note: it will show the diffrent pwwn on netapp leave that focus on target value
match that value with show flogi database, 2 mac address are bind on int e1/35
so i selected pwwn accordingly.
Both side all zoning config is there. We only edit pwwn and activate the zone.
2.9
3.1 - ACI
Legacy2 - 172.16.4.10
Legacy1 - 172.16.4.20
2 AEP for physical has been configured. One is "Entity-Phy" and "Baremetal-enty-
phy". so I have used which was mapped with Fex 102
VLAN - Both VLAN pools were setup "Inherit from parent". We need to change it to
dynamic/static accordingly.
FEX101 and FEX102 both are there. No CDP Enable policy create. I have created CDP
policy
Attach all this to Switch Profile and after that FEX ports are showing
****AMBER****** color.
3.2
3.3
Under VMM config - CDP was not mapped. I selected cdp enable. LLDP was already
pre-. need to enable.
VLAN pool was pre-config
3.4
create POD profile named as default. That is not mapped in POD policy. We need to
map it to the "default" which is already created.
VRF for L3out and Xandar BD was same (i.e common/default). Rest is all according to
workbook
Scope of Web to External contract needs to be changed from App Profile to VRF.
3.5
Same as workbook. In Route-map used aggregate option. 1 permit (web IP) and 1 deny
statement (entire network)
3.6
pre-config was with 239.0.0.0/8 and 225.0.0.0/8. I removed that and changed it as
per the workbook. Make sure to do this under VRF in IPN
3.7
All contracts were already provided and consumed. We need to check properly once
though.
3.8
So I used same parameter from above. Dont waste time on copy. type it with
alignmnet
its work and 100 epg created. I did not create VRF
bcoz question ask for create APP for each epg. so VRF not required.
Note:- During ACI verification , I just stop ping from epg from vcenter. Due to
this few epg not showing.
so, I again started continue ping.