GS GS GS GS GS GS GS GS GS GS GS GS GS GS
AH
N IF
----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- -----------
14 13 12 11 10 09 08 07 06 05 04 03 02 01
HA
TABLE :SUMMERY OF BUILDING D1-GS-03
DI
WA
ART
117000
Name of the Building Type of Construction DISTRICT
9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000 9000
DIRIYAH
DGDA NCD GOVERNMENT OFFICE Type II B NORTH
GS
----------- INDICATIVE M. TOILET
27 AREA O,L
L1-54
PLOT
AREA LIMIT
O,L
(M²)
16
(M²/P)
28
MEP SHAFT (M²) (M²/P)
12 28
OL
1
EXIT
1 STAIR 02
OL
1
EXIT
1 TRAVEL DISTANCE LIMITS
L1-10
ORIENTATION
9000
North
SSL 662.850 m OCCUPANCY TRAVEL DISTANCE (M) TRAVEL DISTANCE WITHIN UNIT (M) COMMON PATH (M) DEAD - END (M)
FFL 663.000
FFL 663.000 mSSL 662.650 m MAX. MAX. MAX. MAX. MAX. MAX. MAX. MAX.
mSSL 662.850 m
UP PROVIDED PERMITTED PROVIDED PERMITTED PROVIDED PERMITTED PROVIDED PERMITTED
GS
-----------
IDF ROOM
L1-20 Mecca
75 As per SBC.201 23 As per SBC.201 30 As per SBC.201 15 As per SBC.201
26
EXIT
DN
FD90
FD60 STORE NA NA NA NA
JANITOR ROOM Table 1017.2 Table 1006.2.1 Table 1006.2.1 Section 1020.4
FD60 L1-07
90 As per SBC.201 30 As per SBC.201 15 As per SBC.201 Disclaimer: By the Consultants ’review status indicated herein, the Contractor shall not be relieved of
FFL 663.000 BUISINESS 72.3 NA NA NA NA responsibility for any deviation from the requirements of the Contract Documents, unless the Contractor has
FFL 663.000 m PL. SHAFT mSSL 662.850 m Table 1017.2 Table 1006.2.1 Section 1020.4 specifically informed the Consultant of such deviation in writing at the time of the submission. The Contractor
9000
SSL 662.850 m shall not be relieved from responsibility for errors, omissions or uncoordinated information in the submission
MECH.SHAFT or non-compliance with the Contract Documents and Applicable Laws. The recipient is responsible to ensure
FD60 75 As per SBC.201 30 As per SBC.201 15 As per SBC.201
LIFT LOBBY MEP NA NA NA NA NA the contents of this disclaimer are understood by personnel in their organization.
FD90 SL2 Table 1017.2 Table 1006.2.1 Section 1020.4
L1-12 GENERAL NOTES
FD90
IT RISER FD90 PL3
GS
-----------
INDICATIVE F. TOILET
L1-55
GENERAL NOTE :-
25 AREA O,L
FFL 663.000 ELEC ROOM
L1-35
FD90 ALL SINGLE LEAF DOORS SHALL HAVE A MINIMUM CLEAR WIDTH OF NOT LESS THAN 800mm &
mSSL 662.650 m
(M²)
1160
(M²/P)
9.0
INDICATIVE ALL DOUBLE LEAVES DOOR SHALL HAVE ONE LEAF DOOR NOT LESS THAN 800mm
OL EXIT OFFICE ELEC.RISER
129 2
AREA MEP RISER AS PER SBC 201 SECTION 1010.1.1.
L1-08 PH RISER INDICATIVE
9000
EXIT
EXIT
mSSL 662.725 m 950 190
OPEN
9000
TO SKY
TERRACE
L1-16
FFL 663.000 m T.O.P 664.20 m
SSL 662.650 m T.O.P 664.20 m
GS
-----------
23
INDICATIVE OPEN
TO SKY OPEN
OFFICE TD = 63.3m TO SKY
AREA
9000
FFL 663.000
TD = 68.6m
mSSL 662.850 m
TERRACE
GS
-----------
L1-25
TERRACE
L1-24
22
TD = 61.0m
FFL 663.000
mSSL 662.725 m FFL 663.000 PLOT LIMIT
mSSL 662.725 m
OPEN
FFL 663.000 TO SKY FFL 663.000 m
mSSL 662.850 m T.O.P 664.10 m SSL 662.650 m
TERRACE
MECH.SHAFT L1-22
GS
108000
FD60
STAIR 03
L1-15
T.O.P 664.10 m
DN INDICATIVE F. TOILET
TD = 35.0m
L1-57
9000
mSSL 662.850 m
)
9000
T.O.P 664.20 m
3m
m
2.
1.9
(4
=9
0m
TERRACE
L1-23
7.
TERRACE
ES
OPEN
12
GS
----------- FFL 663.000 TO SKY
L1-03
=
19 mSSL 662.725 m
DD
SSL 662.850 m
OPEN
TO T.O.P 664.20 m T.O.P 664.10 m
9000
ROOF BELOW
53 m²
IT
L1-58 FFL 663.000
MECH.SHAFT
EX
mSSL 662.650 m
FD60 FFL 663.000
STAIR 01 INDICATIVE DN mSSL 662.850 m
L1-17 AREA O,L OFFICE
9000
(M²) (M²/P)
LIFT LOBBY 2948 9.0 AREA
L1-13 FD90 OL EXIT L1-08
327 5
L1-02
ELEC. ROOM FD90 mSSL 662.850 m TD = 46.9m TD = 72.3m
GS
-----------
L1-05
17 MECH.SHAFT
T.O.P 664.80 m
AREA O,L MECH.SHAFT
(M²) (M²/P) MECH.SHAFT MECH.SHAFT F 100% DETAILED DESIGN GP SYS 30 OCT 2023
248 9.0
FFL 663.000 E 50% DETAILED DESIGN GP SYS 18 SEP 2023
OL
28
EXIT
1 mSSL 662.850 m
OPEN D 100% SCHEMATIC DESIGN RESUBMISSION SGA SYS 12 APR 2023
OPEN
9000
PROVISION
PROVISION 30 Minutes FIRE RATED WALL
EXIT
FFL 663.000
VOID
mSSL 662.850 m 1 HOUR (60 Minutes) FIRE RATED WALL
FD60
7747 UMRO ADHAMRY STREET,
FD90
LIFT LOBBY VL1 2 HOUR (120 Minutes) FIRE RATED WALL DIPLOMATIC QUARTER
GS
-----------
EXIT L1-52
TERRACE FD20 20 Minutes FIRE RATED DOOR SET
UNIT #2, RIYADH 12512,
KINGDOM OF SAUDI ARABIA
WWW.DGDA.GOV.SA
15 FD90
DN
FFL 663.000
mSSL 662.650 m
L1-28
FFL 663.000 m
FD60 1 HOUR (60 Minutes) FIRE RATED DOOR SET PROGRAMME MANAGEMENT CONSULTANT
SSL 662.650 m
PLOT LIMIT MECH.SHAFT AL RAIDAH DIGITAL CITY, BUILDING WH14, 2ND FLOOR,
FD90 PRINCE TURKI IBN ABDULAZIZ AL AWWAL ROAD,
2 HOUR (90 Minutes) FIRE RATED DOOR SET AL NAKHEEL DISTRICT,12384 RIYADH
WWW.ARCADIS.COM
T.O.P 664.80 m 20 Minutes FIRE RATED OPENING / FIRE SHUTTER
STAIR 05 SCHEDULE OF OCCUPANT LOAD CONSULTANT
L1-51
1 HOUR (60 Minutes) FIRE RATED OPENING PO BOX 333256 OFFICE NO.A201-203
BUILDING 6 , DUBAI DESIGN DISTRICT
USE / LOCATION AREA (m2) OCCUPANT LOAD FACTOR (m2/PERSON) OCCUPANT LOAD (PERSON) 2 HOUR (120 Minutes) FIRE RATED OPENING DUBAI
UNITED ARAB EMIRATES
DIAGONAL DISTANCE - DD = ##.#m (31 OF DIAGONAL)
OFFICE ( EAST WING) 1501 9.0 167 SUB CONSULTANT
EXIT SEPARATION - ES = ##.#m
OFFICE (NORTH WEST WING) 1160 9.0 129
TRAVEL DISTANCE - TD = ##.#m
OFFICE (SOUTH WING) 1290 9.0 143
ALTERNATIVE PATH TO AN EXIT
PROJECT TITLE
CEO OFFICE 248 9.0 28 TRAVEL DISTANCE WITHIN THE UNIT - TDWU = ##.#m
DGDA NCD GOVERNMENT OFFICE
MEP AREA 142 28.0 5 COMMON PATH DISTANCE - CP = ##.#m
PROJECT ADDRESS: AD DIRIYAH, RIYADH, KINGDOM OF SAUDI ARABIA