You are on page 1of 20

ECP190 / ECP290

DOOR CONTROLLERS

STAND ALONE
ACCESS CONTROL

Site Coded & Sequentially


Numbered Access Passes
for Security, Identification &
Operational Integrity.

nacd.co.uk
ECP190
ECP190
/ ECP290
/ ECP290
DOOR
DOORCONTROLLERS
CONTROLLERS
contents
Explanation of Noralsy ® Access Passes 3

General Door Controller Information 4

ECP 190 Door Controller schematic 5

ECP 290 Door Controller schematic 6

How to use the Telpro™ programmer 7-8

Programming

Set-up on installation 9-10

Block loading of Access Passes 10

Deleting individual Access Passes 10-11

Validating individual Access Passes 11

Block deletion of Access Passes 11

Changing lock output time 11

Changing the Master Code 11

ECP290 Additional Features 12-13

Dual Security, Code + Access Pass 13

Fail Safe locking schematic 14

Automation/Volt Free schematic 14

General Locking schematic 15

Din Rail Mounting 15

Din Rail Power Supplies 16

Powering ECP Door Controllers using Din Rail PSU 17

Programming Keypad Codes 18-19

2
NORALSY® ACCESS PASSES

ALL ACCESS PASSES ARE Numbered Rear of KCP300


Proximity Key
VISIBLY NUMBERED
The number of each and every Access Pass is visible. Just by looking at it,
you know which Access Pass you have. Noralsy® pre-number each Access
Pass because this is the only way you can know for sure what you have
received, what you need to program the system to accept (or, reject in the
case of loss, theft or non-return) and, who has been issued with which
Access Pass. TELBIPHF42 Numbered

ALL ACCESS PASSES ARE SITE CODED


An Access Pass is always part of a unique group referred to as a Site Code and
TELBIPHF42
represented by a 5 digit number. Your purchase of Noralsy® Access Passes buys you
that group (Site Code) regardless of how many Access Passes you require. That Site
Code belongs to you and you alone. Noralsy® will never make an Access Pass with
your Site Code for anybody else. That is your security.
Site
Code h eet
tion S
s In forma The first 3no. digits of the 5no. digit Site Code
s Pas Rear of KCP300
Acces
Date
are always engraved on each Access Pass. Proximity Key
e
Site Cod

Code
The last 2no. digits are usually the year of
USE ON
LY Set No.
NISO

er numb
ers
manufacture.
NACD Your ord
No.
e nu mbers

CUST
OM ER DE
TAILS

me
Invoic
Example: First 3 digits engraved on Access
mer na
Custo

Projec
t referenc
e

2 Pro
xim ity cards wit
h ma gnetic
strip
Pass are 494.
KBP0 tter
transmi

ACCE
SS PA
SS TY

CPAS
S
PE

Card
(magne
tic strip) TELB
IPHF4

IPH
2 Radio

FP423
Radio
transmi
tter wit
h prox
Year of manufacture 2001, therefore,
TELB
ity keys
KC P300

KBP0
Proxim

1 Pro
ximity
card
tter
Hand
s free

ur custo
mer. Yo
u will
need
this

Access
last 2n0 digits of site code are 01.
transmi e to yo sses. ved on the
ra-red is uniqu ss Pa
IP4 Inf e Code more Acce engra
TELB igit Sit ng nted or Code
.
The 5-d when orderi o. digits pri 5-digit Site

Site Code =
er 3n the
numb the first its of te
mber, rst 3no. dig indica
DES Reme fi Pass
SS CO Pass
are the Access
SS PA on the
ACCE raved
d/eng
printe
digits low.
Site co
de
Th e las
the Ho
t 4no.
lder Nu
mb er. See be
Engraved Not
s
From on Access Pass engraved* Site
r code
Holde
range
To
ion ad
dress Code
Installat

The full 5no. digit Site Code is written on the Access Pass Information Sheet supplied by Noralsy® with each
delivery of Access Passes.

*The full 5n0 digit site code is printed on KBP Proximity Cards.

ALL ACCESS PASSES ARE SEQUENTIALLY NUMBERED


Access Passes are always supplied in groups that are
TELBIPHF42
sequentially numbered which simplifies programming because it
enables block loading and block deleting of Access Passes. It
also means that you can quickly and easily determine which
Holder
heet
Access Passes are missing and need, therefore, to be deleted
Number a tion S
s Pas
s Inform in order to restore the integrity of your system.
Acces
Date

e
Site Cod

Code Rear of KCP300


NISO
Proximity Key
LY Set No. ers
USE ON er numb
NACD Your ord
No. ers
e numb
ILS Invoic
DETA
OMER
CUST
me
mer na
Custo
nce strip
t refere gnetic
Projec with ma
cards
ximity

ACCE
SS PASS
TY PE
tic str
ip)
KBP0

TELB
2 Pro

IPH F4 2 Radio
transmi

dio tra
tter

nsmitte
r with prox Last 3 digits engraved
(magne
Card 423 Ra
CPAS
S

KCP3
00 Pro
ximity
keys

ity card
TELB

Hand
IPHFP

s free
u will
need
this
refer to Holder Number.
1 Pro
xim mer. Yo
KBP0 tter ur custo Access
transmi e to yo sses. ved on the
ra-red is uniqu ss Pa
IP4 Inf e Code more Acce engra
TELB igit Sit ng nted or Code
.
The 5-d when orderi o. digits pri 5-digit Site
er 3n the
numb the first its of te
me mber, rst 3no. dig ss indica
DES Re fi Pa
SS CO Pass
are the Access
SS PA on the
ACCE raved
d/eng
printe
digits low.
Site co
de t 4no. See be
The las r Number.
the Ho
lde
The Holder Numbers supplied are also recorded on
Holder
Holde
range
r code
s
From

To
ion ad
dress
the Access Pass Information Sheet. Number
Installat

3
Noralsy ECP Door Controllers

IMPORTANT –If NOT Monitoring Door Open/Closed Status


OR
ECP ALARM ELEC/INST/800
BUZZES CONTINUOUSLY

6 5 4 3 2 1 6 5 4 3 2 1

ON 1

ECP Door Controller

Standardisation of Terminal Numbering

Place Noralsy unit on a flat surface with PCB facing skywards.


View terminal blocks from the outside looking in. Terminal No. 1
is always the first on the left of every terminal block strip.

1 2 3 1 2 3 4 1 2 3
1 2
1 2 3
1 2 3

1 2 3 4 5 6

1 2 3 4
1 2 3 4 5
1 2 3 4 5 6
1 2 3 4 5 6 7
1 2 3 4 5

1 2 3 4 5 6 7 8
1 2 3

1 2 3 1 2 1 2 3 4 5 6

ELEC/INST/GEN

4
ECP190 Door Controller for
1 n0 Door/Access Point

■ Capacity 999 Users

ELEC/INST/801

ECP 190 Door Controller

Supply 12V DC ± 10%


Dimensions 103 L x 106 W x 83 D (6 DIN units)
Weight 0.44 Kg
3 2 1 2 1
Power Consumption 55mA quiescent
(—) (+)
CE Norms EN50082, EN55022 Class B

3 2 1 3 2 1 2 1

1 5
2 4
3 3
4 2
5 1

1 ON

1 2 3 4 5 6 1 2 3 4 5 6

=
1 2 3 4 5 6 =

If not used, link terminals 3 & 4 to


create a permanently closed circuit.

5
ECP290 Door Controller for
2n0 Doors/Access Points

■ Capacity 999 Users per door

ELEC/INST/830
ANTI-PASSBACK FEATURE AVAILABLE

ECP 290 Door Controller

Supply 12V DC ± 10%


Dimensions 163 L x 106 W x 83 D (10 DIN units)
Weight 0.56 Kg
* If not used, link terminals 3 & 4 to Power Consumption 160mA quiescent
create a permanently closed circuit. CE Norms EN50082, EN55022 Class B

6
Programming Stand-Alone
Access Control Systems
using TELPRO™ Programmer.

TELPRO™ PROGRAMMER Access Control Modules with integral Infra-Red


The TELPRO™ Programmer is a handheld MLP3 Proximity

keypad used for programming Noralsy® The TELPRO™ Programmer


stand-alone access control systems. can be used as a wirefree
infra-red programmer. Simply
Installation companies only ever need 1no. point at the reader/receiver
TELPRO™ Programmer. module to program.
TELPRO™ can be used on any system
provided, of course, the Master Code (also
referred to as the Engineer Code) which
grants access into programming mode is
known or, access to the ECP Door Controller
itself is available.

The final customer only needs a TELPRO™


MIR Infra-Red
unit if they wish to effect programming
themselves.

TELPRO™
Programmer

Access Control Modules, Readers, Receivers without integral Infra-Red

The TELPRO™
Programmer is
LPT03 MILB
supplied with a Office Proximity Reader Card Reader
connector cable.
Simply connect to
ECP Door Controller
to program.

ECP190
ECP290
TELPRO™ ECP100
Programmer ECP200
Dim: LHF42
Radio receiver
120L x 60W x 25D

If the entrance or door panel includes a MICAM/MICIM Keypad Module connected to the ECP Door Controller, all
programming can be effected directly via the MICAM/MICIM Keypad ie. TELPRO™ Programmer would not be
required. You would also then have the option of having keypad access codes.

All measurements in millimetres. 7


Programming using TELPRO™ as a remote
wire-free programmer.
Remote Programming Range:
Infra-Red Receiver 20 cms - 5 metres
Proximity Reader 5 cms - 10 cms

How to use the TELPRO:

Important: Flick TELPRO switch to ON - Red LED on the right must light up.
Dimensions (mm):
Each press of a button (Remember to turn unit off when finished) 120L x 60W x 25D
is confirmed (as
received) by the
reader/receiver by a
single beep. Press the Point TELPRO at the reader/receiver.
TELPRO™ buttons
gently.

Enter the Master Code and wait for the reader/receiver to start beeping every 4 seconds

OR

Flick Programming Switch SW1 and wait for the reader/receiver to start beeping every 4 seconds
(Remember to turn off the programming switch SW1 when you have finished programming).

Follow programming instructions

Note: An incorrect programming operation is signalled by a series of 3 beeps.

Programming using TELPRO™ as a


hard-wired programmer
ECP290/ECP200
How to use the TELPRO as a hard wired unit: J5 = Access Point 1
J6 = Access Point 2
Insert the jack connection into the top of the TELPRO unit.

Plug the connector terminal onto J5 on ECP Door Controller.

Enter the Master Code and wait for the unit


to start beeping every 4 seconds
OR
Flick Programming Switch SW1 and wait for the unit
to start beeping every 4 seconds Important:
(Remember to turn off the programming switch SW1 Each press of a button is confirmed (as
when you have finished programming) received) by the Door Controller by a
single beep.
Press the TELPRO™ buttons gently.
Follow programming instructions.

8
ECP Door Controller with PROGRAMMING
ACCESS PASS CONTROL
TOP POINTS TO REMEMBER

■ Programming is effected via the TELPRO programming keypad.

■ Site Code is always a 5 digit number.


■ Site Code is always stored in Slot No. 01.

■ Master Code (Programming Access Code) is always a 5 digit number.


■ Master Code is always stored in Slot No. 06.

TIP - WHEN YOU ARE PROGRAMMING

It is a good idea to have written down in advance what you want to program. Enter the numbers in quick succession
after a beep. Do not wait more than 2-3 seconds in between entering numbers as this will confuse the system.

SET-UP ON INSTALLATION

Wire up according to appropriate electrical wiring schematic for your installation, then power up the Door Controller.
Flick the Programming Switch SW1. The unit will start beeping every 4 seconds.

STEP 1

Decide Now -- For how many seconds do you want the door to open: Example

08 seconds

Basic configuration,
After a beep enter on the TELPRO: 000005 08 just do it!

The last 2no. digits, shown as underlined, set the door open time in seconds. You can choose any length between 01 -
99 seconds. For automation control, 01 seconds is usually more than adequate.

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds -
resumes.

STEP 2
Basic configuration,
After a beep enter on the TELPRO: 02A0 just do it!

A sharp beep confirms that you have correctly entered the above. Programming mode beep - every 4 seconds -
resumes.

STEP 3

You must now set the Master Code of your choice. This is the code that allows you to access programming mode
without having to open up the Door Controller and flicking switch SW1.

The Master Code is always stored in Slot No. 06.


The Master Code must be a 5 digit number, for example: 19388.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the Master Code. Programming mode beep - every 4 seconds -
resumes.

9
STEP 4

You must now inform the Door Controller of the Site Code of the Access Passes supplied.

The Site Code is always stored in Slot No. 01.


The Site Code is always a 5 digit number.

Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you the Site Code of the Access
Passes delivered.
*
Example: Site Code = 45801

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the Site Code. Programming mode beep - every 4 seconds -
resumes.
*KBP Proximity Cards have the full site code printed on each card.

STEP 5

You must now inform the Door Controller of the Access Pass Holder Numbers supplied.

Check the Access Pass Information Sheet delivered with the Access Passes. It will tell you which Holder Numbers we
have supplied.

Example: 150no. Access Passes Supplied........HOLDER NUMBERS 001-150.


*See Tip Wizard
on page 13
After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have correctly entered the Holder Numbers.
Programming mode beep - every 4 seconds - resumes.

STEP 6

Turn off programming switch SW1 in the Door Controller. You have successfully programmed the system. The Access
Passes should now all work.

ADVANCED PROGRAMMING

In the following examples of programming we are assuming that the Master Code = 19388. This is purely for
demonstration purposes. When programming for real, you must enter the Master Code that you chose and set when
the system was installed.

Example A: Block Loading/Validation of Access Passes.

You have just received an additional 25no. Access Passes for the system. Holder Numbers 151- 175.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming
Mode.

After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have correctly entered the Holder Numbers.
Programming mode beep - every 4 seconds - resumes.

Example B: Deletion of 1no. Access Pass

You have just been informed that Alan Jones has lost his Access Pass. Alan was Holder Number 074. You have to
delete it immediately to restore system security. Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds
indicate that you have accessed Programming Mode.

10
After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly deleted Holder Number 074. Programming mode beep - every 4
seconds - resumes.

Example C: Validation of 1no. Access Pass

You have just received the additional Access Pass ordered for Alan Jones who had lost his earlier in the week. The last
3no. digits on the Access Pass are 176. Alan Jones is now Holder Number 176 and you have to program the system to
accept Holder Number 176.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming
Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly programmed new Holder Number 176. Programming mode beep - every
4 seconds - resumes.

Example D: Block Deletion of Access Passes

You have just been informed that a set of 20 Access Passes reserved for visitors and held in reception have been
stolen. You have to immediately delete them to restore system security. The Holder Numbers stolen were 080-099.

Enter the Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed Programming
Mode.

After a beep enter on the TELPRO:

A series of 3no. beeps followed by a sharper beep confirms that you have deleted the Holder Numbers. Programming
mode beep - every 4 seconds - resumes.

Example E: Changing the Relay/Lock Output Time

You have been asked to change the Relay Output Time to 12 seconds.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed
Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly reprogrammed the relay output time for 12 seconds. Programming
mode beep - every 4 seconds - resumes.

Example F: Changing the Master Code

You have been asked to change the Master Code to 11821.

Enter the current Master Code 19388 on the TELPRO. Beeps every 4 seconds indicate that you have accessed
Programming Mode.

After a beep enter on the TELPRO:

A sharp beep confirms that you have correctly entered the new Master Code. Programming mode beep - every 4
seconds - resumes.
11
ECP290 DOOR CONTROLLER FOR 2 DOORS – IMPORTANT
INFORMATION
FLICKING PROGRAMMING SWITCH SW1.
The access control readers on both doors will start to beep every 4 seconds indicating programming mode status. Only
1 no. access point (door) can be programmed at a time.

IF USING THE TELPRO PROGRAMMER IN WIREFREE INFRA-RED MODE:


Simply point at the relevant reader to effect programming for its related access point (door). Repeat the process for the
2nd access control reader on the ECP290. Remember to turn off programming switch SW1 when finished.

IF USING TELPRO PROGRAMMER IN HARDWIRED MODE:


Connect as follows:
J5 for the reader connected to I2A1, Access Point 1.
J6 for the reader connected to I2A2, Access Point 2.
Remember to turn off programming switch SW1 when finished.

Note: Programming mode can, of course, be accessed via entering the Master Code (the code stored in Slot No. 06)
as explained earlier.

ADDITIONAL FEATURES OF ECP290


Activating one of the additional features offered by the ECP290 is very straightforward and involves a very slight
modification of Step 1 (see page 9) of the Programming Operation.

Remember: The programming operation has to be effected for each access point (door).

00000508 = Standard Set-Up, adequate for the vast majority of installations. If this is sufficient, simply copy the
procedure, as explained on page 9, for both doors.

Mode 2 - Access Pass to Operate Only if Vehicle Present

00200500 = Set-Up, Mode 2


®
Alarm delay time in minutes. A 00 setting disables the alarm function.

When a valid access pass is presented to the reader, the relay output will be activated for 2 seconds BUT ONLY IF the
Magnetic Induction Loop (M.I.L) contacts, terminals 1 & 2 of J10A1 or J10A2, have closed ie a vehicle is present. If the
M.I.L contacts remain closed for longer than the preset alarm delay time, the access control reader/receiver/keypad will
sound an alarm.

Mode 3 - Access Pass to Operate Only if Door Closed

00300500 = Set-Up, Mode 3


®
Alarm delay time in minutes. A 00 setting disables the alarm function.

The status of the door is controlled by 2no. sets of contacts as follows:

Open Position Reached (OPR) Contacts: Terminals 2 & 3 of J10A1 (Access Point 1)
Door Open Contacts (DO): Terminals 3 & 4 of J9A1 (Access Point 1)

Open Position Reached (OPR) Contacts: Terminals 2 & 3 of J10A2 (Access Point 2)
Door Open Contacts (DO): Terminals 3 & 4 of J9A2 (Access Point 2)

When a valid access pass is presented to the reader, the relay output will be activated for 2 seconds BUT ONLY IF the
related Access Point (Door) is closed. If the Access Point (Door) remains open for longer than the preset alarm delay
time (DO Contacts OPEN and OPR Contacts CLOSED) or, if the Access Point (Door) is blocked/stuck for longer than
the preset alarm delay time (DO Contacts OPEN and OPR Contacts OPEN), the access control reader/receiver/keypad
will sound an alarm. 12
Mode 4 - Dual Security, Access Pass + Keypad Code

00400508 = Set-Up, Mode 4


®
Relay output time in seconds

User required to present a valid access pass and then enter a valid code or vice versa in order to gain access. A
maximum of 27no. 5 digit keypad codes can be set at any one time. Any 1no. of these keypad codes together with a
valid access pass is sufficient to gain entry. This feature is also available on the ECP190 Door Controller.

Mode 5 - Anti-Passback

00500508 = Set-Up, Mode 5


®
Relay output time in seconds (this is an example only).

For Anti-Passback to operate, terminals 3 and 4 of J9A1 and J9A2 must be connected to the
Door Contacts fitted to the controlled doors. This is imperative because the Door Controller
cannot operate Anti-Passback if it does not know whether the door was opened or not.

Basic operation is as follows:

The presentation of a valid Access Pass on Door 1 activates the relevant lock release relay. If Door 1 is opened, this
Access Pass is immediately and automatically barred on Door 1 until it has been presented on Door 2 with Door 2 then
being opened. As soon as this Access Pass is presented on Door 2 with Door 2 being opened, it is immediately and
automatically barred on Door 2 until it has been presented on Door 1 with Door 1 then being opened etc etc.

Tip Wizard
Access Passes can be programmed into the access control system even if
they have not yet been manufactured by Noralsy® . Your customer may have
ordered only 50no. Access Passes and would have had delivered, for
example holders 001-050 on their unique Site Code but, there is nothing to
stop you from block programming all 999 holders. It takes the same
amount of time to program 1no. Access Pass into the system as it does to
program 999 Access Passes! So, future supplies of Access Passes are
already programmed into the system and your customer should only ever
have to delete lost or stolen Access Passes!

It is so easy: B001 B999.

VERY IMPORTANT
Noralsy® Access Passes must not be compared or confused with random Access Passes-
for example, certain brands of proximity key - where the onus is on the installation
company to “accurately” identify each Access Pass programmed into the system and
physically mark them so that they can be “sure” who is issued with what or, those
systems, which rely on shadow cards or master keys/fobs for programming purposes.

13
Noralsy® ECP Door Controller

Fail Safe Locking

3 2 1 3 2 1 2 1
(—) (+)

ECP190 Door Controller ELEC/INST/802

Automation Control / Volt Free

3 2 1 3 2 1 2 1

ECP190 Door Controller ELEC/INST/803

Entrance/Exit
Access point requiring access control on both
sides of the door, gate or barrier. 1 2 3 4 5 6 6 5 4 3 2 1
ie. Access Pass to be presented to enter and
again to exit through the same control point.

Note: In this type of installation, programming


can take place via the TELPRO
programmer at either one of the Access
Pass readers/receivers or, alternatively, at
the Door Controller itself.
You only need to program at 1no. point.
6 5 4 3 2 1 6 5 4 3 2 1
* Terminal numbering shown for
reasons of schematic clarity.
Terminal 1 is actually first on left.

ECP190 Door Controller ELEC/INST/804

14
Noralsy® ECP Door Controller

Locking

3 2 1 3 2 1 2 1
(–) (+)

ECP190 Door Controller ELEC/INST/805

DIN Rail Mounting

DIN Rail

ELEC/INST/806

Wall Mounting

ELEC/INST/807

15
Noralsy® DIN Rail Power Supplies

ARE121 12V AC/DC ARE122 12V DC


1 AMP MAXIMUM OUTPUT 2 AMP MAXIMUM OUTPUT

ELEC/INST/808 ELEC/INST/809

ARS122 12V DC AB126 BATTERY STANDBY


2 AMP MAXIMUM OUTPUT

ELEC/INST/810 ELEC/INST/811

16
Noralsy®
Powering ECP Door Controller(s)
using Noralsy® DIN Rail Power
Supply Units

ARE121 + ECP190

ELEC/INST/812

ARE122 + ECP290

ELEC/INST/812A

17
ECP190 DOOR CONTROLLER with
KEYPAD ACCESS CODE CONTROL

TOP POINTS TO REMEMBER

■ Programming is effected directly via the keypad.

■ Master Code (Programming Access Code) is always a 5 digit number.


■ Master Code is always stored in Slot No. 06.

■ Keypad Access Codes are always 5 digit numbers.


■ Keypad Access Codes can be stored in Slot Nos. 03 - 05 and 07 - 30 only.

SET-UP ON INSTALLATION

Proceed exactly as detailed before in section ECP Door Controller with Access Pass Control. Stop when you have
completed Step 3. Then - Turn off programming switch SW1 in the Door Controller.

PROGRAMMING KEYPAD ACCESS CODES

Keypad Access Codes must be 5 digits in length and can only be stored in Slot Numbers 03-05 and 07-30.

Example: You want to program codes: 46296 for Alan


78327 for Tony
32534 for Alex

Enter the Master Code on the keypad:

Beeps every 4 seconds indicate that you have accessed Programming Mode.

After a beep enter on the keypad:

A sharp beep confirms that Alan’s code is recorded. Programming mode beep - every 4 seconds - resumes.

After a beep enter on the keypad:

A sharp beep confirms that Tony’s code is recorded. Programming mode beep - every 4 seconds - resumes.

After a beep enter on the keypad:

A sharp beep confirms that Alex’s code is recorded. Programming mode beep - every 4 seconds - resumes.

Note Carefully:
Never program a keypad access code into Slot Numbers 01, 02 or 06.

DELETING KEYPAD ACCESS CODES

Example: You want to delete Alan’s code 46296 which is stored in Slot No. 03
You want to delete Alex’s code 32534 which is stored in Slot No. 07

Enter the Master Code on the keypad:

Beeps every 4 seconds indicate that you have accessed Programming Mode.

18
After a beep enter on the keypad:

A sharp beep confirms that you have deleted Alan’s code. Programming mode beep - every 4 seconds - resumes.

After a beep enter on the keypad:

A sharp beep confirms that you have deleted Alex’s code. Programming mode beep - every 4 seconds - resumes.

Note 1. You do not need to know the actual code itself which needs to be deleted, only the Slot Number in which it is
stored.

Note 2. Capacity is never reduced as a result of deleting codes. You can always add or change codes.

CHANGING THE MASTER CODE

Refer to page 11.

CHANGING RELAY/LOCK OUTPUT TIME

Refer to page 11.

Automatic Time-Out – whenever programming accessed via Master Code


System automatically reverts to normal mode approximately 20 seconds after the last
programming operation. A single longer sharp beep signals that the system has exited
from programming mode and returned to normal mode.

19
ECP 190 DOOR CONTROLLER ARE122 POWER SUPPLY
Input 85VAC - 264VAC
Supply 12V DC ±10%
Output 12V DC - 2AMP
Dimensions 103 L x 106 W x 83 D (6 DIN units)
Dimensions 160 L x 106 W x 85 D (10 DIN units)
Weight 0.44 Kg
Weight 0.5 Kg
Power Consumption 55mA quiescent
CE Norms EN55022 Class B, EN 60950, UL 94 VO
CE Norms EN50082, EN55022 Class B

ARS122 POWER SUPPLY WITH STAND-BY FACILITY


ECP 290 DOOR CONTROLLER Input 85VAC - 264VAC
Output 12V DC - 2AMP
Supply 12V DC ± 10% Dimensions 160 L x 106 W x 85 D (10 DIN units)
Dimensions 163 L x 106 W x 83 D (10 DIN units) Weight 0.5 Kg
Weight 0.56 Kg CE Norms EN55022 Class B, EN 60950, UL 94 VO
Power Consumption 160mA quiescent
CE Norms EN50082, EN55022 Class B
AB126 BATTERY STANDBY
Battery 12V/6A.H.
ARE121 POWER SUPPLY WITH STAND-BY FACILITY Output 12V DC - 2AMP
Input 85VAC - 264VAC Dimensions 162 L x 106 W x 112 D (10 DIN units)
Output 12V AC/DC - 1AMP Weight 3.0 Kg
Dimensions 135 L x 106 W x 85 D (8 DIN units) CE Norms VDS, IEC 1056
Weight 1.05 Kg
CE Norms EN50082, EN55022 Class B

ACCESS CONTROL MODULES

REFERENCE DESCRIPTION POWER CONSUMPTION

MIR Infra-Red Receiver 25mA quiescent

MILB Card Reader Insert 47mA quiescent

MICAM/MICIM Keypad 50mA quiescent

MLP3 Proximity Reader 120mA quiescent

LHF42 Radio Receiver 50mA quiescent

LPT03 Proximity Reader (office) 120mA quiescent

N.A.C.D. Limited Unit 10, Avebury Court, Mark Road, Hemel Hempstead, Herts HP2 7TA.
TEL: 01442 211848 FAX: 01442 212776 EMAIL: sales@nacd.co.uk WEB: www.nacd.co.uk

www.telephoneentry.co.uk
Our policy is one of continuous product improvement, we reserve the right to change specifications and prices without notice. All information is given in good faith. No responsibility can be accepted for errors, omissions or incorrect
assumptions. Picture reproduction of products are within the limitations of both colour and black and white printing and are intended as a guide only. © Copyright 2008 N.A.C.D. Limited. All rights reserved.

You might also like