!! WARNING
• DO NOT connect a handset or laptop to the controller
network while using the Graphic Display panel in Service
Mode. Doing so can cause the controller programming to
be corrupted and the truck to run improperly.
NOTES:
• Ensure the First Stage (free lift) Switch is installed before
calibrating. Otherwise, the truck will think it is in second stage
and will inhibit the tilt range.
• The program WILL NOT SAVE changes if the Pump is running.
Allow the Pump to stop for 2-3 seconds before saving changes.
• Forward = Forks leading
• Reverse = Forks trailing
1. Turn the Key Switch ON (cycle the Brake Pedal if required).
2. IMPORTANT: Tilt the Mast to full forward tilt position.
3. Press FN 3 on the Meter Panel once to enter tech mode.
4. Enter 55555 (service password).
The Diagnostic Mode screen should now be displayed.
5. Press FN 2 and scroll down to the ADJUSTMENT MODE
SCREEN.
6. Press FN 6 to enter ADJUSTMENT MODE.
7. Press FN 2 to scroll down to ADJUSTMENT.
8. Press FN 6 to enter ADJUSTMENT.
TRACTION CONT RT screen should now be displayed.
9. Press FN 2 and scroll down until the PUMP CONTROL screen
is displayed.
This confidential document is intended ONLY for the internal use of UniCarriers Americas Corporation, its employees, and authorized Dealers. All information contained in this
bulletin was prepared based on the most current information available at the time of printing, is time sensitive, and subject to change without notice.
Verify Calibration
1. Tilt the Mast full forward and then full back.
2. Position the Mast to 90 degrees vertical position.
3. Lift the Carriage above free lift. Tilt and measure the Mast angle
from vertical at full forward and then full back.
The mast should now be limited to 3 degrees tilt forward and
3 degrees tilt back.
4. If the Mast tilts forward more than 3 degrees and tilts backwards
more than 3 degrees, repeat Steps 10-34.
5. Repeat the verification process to ensure the Mast is limited to
3 degrees tilt forward and back.
NOTE:
Please reference ‘Calibration Procedures; Multifunction Handle
(Joystick)’ in the CS Section of the Service Manual for calibration
procedure.