You are on page 1of 1
Al Mawazeen Soil Testing Sh Neat cotileet (Onshore / Offshore, Soil Investigation AARU Ay Sly Lyre! Slt ya!) and Construction Materials Testing) olga logondy M/s. SQUARE METER CONSTRACTION CO. Dubai, United Arab Emirates Our Ret + ¢4-23-0435 Date 16-10-2023 Attention Project Engineer Subject Proposed Villa G#2+ + swimming pool , for Mrs. Zubsida Hammood Mohammad Al Attar on Plot No. 9132693, Umm Nahad 3° = Soil Bearing Capacity (SBC) & Level Confirmation for Shallow Foundation Formation Level at Villa, Boundary Wall, driver room, swimming pool and water tank. Dear Sir, Further to your instructions regarding site inspection for the subject project please note the following. ‘© The site had been excavated up to a depth of approximately -1.00m for main villa and driver room, 1.20m for boundary wall and 1.35m for swimming pool and water tank below the average existing ‘ground Level and then compacted in preparation for the construction of Shallow foundations. ‘© Total of Nine (09) nos. of in-situ density tests and One (01) no. of Proctor tests were carried out by us (Al Mawazeen Lab) at formation layer of 1.0m for main villa and driver room, 1.20m for boundary wall and 1.35m for swimming pool and water tank below the average existing ground Level, Test results are presented in our lab report (Attached), ‘© Degrees of compaction obtained from the tests for sand were 95% to 97% of Maximum Dry Density (mop). ‘©The recommendations are given in soil report and DM Approved Drawing Ref No. 380830-4-1 dated 29 July 2023, ‘© Examination of the formation level and sidewalls indicated that subsurface conditions are consistent with those explained in the above-mentioned report. ‘© No additional comment is required here as the DM Approved Drawing Ref No. 380830-4-1 is being followed. Conclusior Based on the above results and careful observation of soll report and DM Approved Drawing ref-no 380830-4- 1 table 1 can be used safely for Shallow foundations to be set at foundation level of -1.00m for main villa and driver room, 1.20m for boundary wall and 1.35m for swimming pool and water tank below the average existing ground Level. allow Foundation at Villa, Boundary Wall, driver roo! Foundation Depth wpe ot Modus of aw the average | soundations | Footing With (m) Reaction ig Br eve (kien?) 1.0m- Villa 3.110 5.0 150 19,200 am Prermoom™| conventional pad/ 110m - Driver Roo enionalead/ 34t—50 | 150 20 | 3.2m Boundary wall 3150 150 19,200 1.35m- Water Tank fait >a 180 10,200 135m: Swimming Poot | _afe >a 10 10,200 We hope that the above information will satisfy your requirements, however if you require further information, please do not hesitate to contact us. Thanking You, For Al Mawazeen Soll Testing Lab Engr. Ahmed Salah Geotechnical Manager Sed gtd EAONO igen HAYNE TOA OYE GuSL HAV) £ YOAY OFT cisla rt gags Dubai ; Tel. : 4971 4 2583 533 , Fax : +971 4 2583 534 , P..Box : 48595 , Dubai - United Arab Emirates ST Mea eae a

You might also like