You are on page 1of 5

Proposed Redesign Trailer (IS:897) Plan for

Punja & Sons Pte ltd


DRAWING INDEX: PROJECT INFORMATION: TRUCK INFORMATION

SHEET NAME SHEET NUMBER


Plate # IS : 898
Note: Chassis Vin #
Engine #
1) All sizes is to be adjusted on site while TRAILER INFORMATION
constructing the tray. Registration Plate No # IS : 897
2) All dimensions are in mm which is VIN #
converted to meters on site.
3) Truck dimension may defer on site
from what is in paper due to measurement
The contractor shall verify all dimensions
accuracy.
4) All welding bolt & nut and fixing to be done and approved drawing. DRAFTING your
by Truck Stop Motor Repair FUTURE is not liable for errors once
under senior supervision. construction has begun. While all effort has
5) All works done has to meet the requirements been made in the compiling of this plan to
of L.T.A
6) The contact surface of rear barrier bar is not avoid mistakes, the draftsman can not
to exceed more than 600mm from the ground guarantee against human error. The
with Vehicle unladen. contractor of the job must check all
7) the ends extend to within 300mm of each dimensions and other details prior to
side of the vehicle.
construction and to be responsible
thereafter. All calculations and member
sizing should be verified by building official.

SITE ANALYSIS.
See Site Plans.

STRUCTURAL DESIGN CRITERIA.

Punjas
Flour

Your
DRAFTING FUTURE
Architectural Drafting
MOBILE : 8415473 / 9078536
P. O. BOX 4035, Wairabeatia, Lautoka, Fiji Islands
Email : draftingfuture01@gmail.com
OWNER : Punja & Sons Pte Ltd
DRAFTING FUTURE
Your

1200
NO PART OF THIS DOCUMENT SHALL BE COPIED, MODIFIED, STORED OR REDESIGNED IN ANY RELEVANT SYSTEM WITHOUT THE CONCERNS OF

13100

1100

Trailer Plan with Size


N.T.S

1200
Turn Table lock
DRAFTING FUTURE
Your
copyright :

ISSUE FOR APPROVAL


Engineer Architecture REV DESCRIPTION DATE DWG. TITLE : PRINT SCALE 1:1 PROJECT No:
Your
Proposed Redesign Trailer (IS:897) Plan for DRAFTING FUTURE Existing Trailer Plan
SCALE as shown DWG. No.

A01
DESIGN Mahendran(raju)
Architectural Drafting
Punja & Sons Pte ltd MOBILE : 8415473 / 9078536 DRAWN Mahendran(raju)
P. O. BOX 4035, Wairabeatia, Lautoka, Fiji Islands
Email : draftingfuture01@gmail.com DATE Oct, 2020
DRAFTING FUTURE
Your
NO PART OF THIS DOCUMENT SHALL BE COPIED, MODIFIED, STORED OR REDESIGNED IN ANY RELEVANT SYSTEM WITHOUT THE CONCERNS OF

Turn Table lock


1200
DRAFTING FUTURE
Your
copyright :

ISSUE FOR APPROVAL


Engineer Architecture REV DESCRIPTION DATE DWG. TITLE : PRINT SCALE 1:1 PROJECT No:
Your
Proposed Redesign Trailer (IS:897) Plan for DRAFTING FUTURE Existing Truck & Trailer Plan
SCALE as shown DWG. No.

A02
DESIGN Mahendran(raju)
Architectural Drafting
Punja & Sons Pte ltd MOBILE : 8415473 / 9078536 DRAWN Mahendran(raju)
P. O. BOX 4035, Wairabeatia, Lautoka, Fiji Islands
Email : draftingfuture01@gmail.com DATE Oct, 2020
DRAFTING FUTURE
Your
NO PART OF THIS DOCUMENT SHALL BE COPIED, MODIFIED, STORED OR REDESIGNED IN ANY RELEVANT SYSTEM WITHOUT THE CONCERNS OF

13100

13000

11986
40 feet container
5853

20 feet container
5853 1804 5343
20 feet container 20 feet container
1510

1000 8419 1310 1310 1060


DRAFTING FUTURE
Your
copyright :

ISSUE FOR APPROVAL


Engineer Architecture REV DESCRIPTION DATE DWG. TITLE : PRINT SCALE 1:1 PROJECT No:
Proposed Redesign Trailer (IS:897) Plan for Your
Punja & Sons Pte ltd DRAFTING FUTURE Existing Trailer Elevation
SCALE as shown DWG. No.

A03
DESIGN Mahendran(raju)
Architectural Drafting
MOBILE : 8415473 / 9078536 DRAWN Mahendran(raju)
P. O. BOX 4035, Wairabeatia, Lautoka, Fiji Islands
Email : draftingfuture01@gmail.com DATE Oct, 2020
DRAFTING FUTURE

10400
Your

7800
NO PART OF THIS DOCUMENT SHALL BE COPIED, MODIFIED, STORED OR REDESIGNED IN ANY RELEVANT SYSTEM WITHOUT THE CONCERNS OF

2600

existing tank fixed with


Punjas existing tank fixed with
stifner plate
Flour stifner plate

600 6000 1200


container lock
mounted on trailer container lock
mounted on trailer

1510
1310
1000 4538 1310 952

180 Ub trailer joist 7800


ferocraft weld and fix
container lock M.20 nut and bolt fix to tank
mounted on trailer
ferocraft weld and fix

180 Ub trailer joist container lock


ferocraft weld and fix mounted on trailer
DRAFTING FUTURE

M.20 nut and bolt fix to tank ferocraft weld and fix
Your

100 PFC floor joist


copyright :

ISSUE FOR APPROVAL


Engineer Architecture REV DESCRIPTION DATE DWG. TITLE : PRINT SCALE 1:1 PROJECT No:
Proposed Redesign Trailer (IS:897) Plan for Your
Punja & Sons Pte ltd DRAFTING FUTURE Proposed Truck & Trailer Elevation
SCALE as shown DWG. No.

A04
DESIGN Mahendran(raju)
Architectural Drafting
MOBILE : 8415473 / 9078536 DRAWN Mahendran(raju)
P. O. BOX 4035, Wairabeatia, Lautoka, Fiji Islands
Email : draftingfuture01@gmail.com DATE Oct, 2020

You might also like