6 / 1 kV PVC izoleli Giig Kablolai 6/1 kV PVC Insulated Power Cables = 6©oo9 1) Som veya Orguli Bakar Solid or Stranded Copper 2) PVC lzole PVC Insulation 3) PE Dolgu PE Filler 4) PVC Kilt PVC Sheath Soba Single Round Conductor Gok Tall Yuva ioe Thu Wie Round Concvtor STANDARD TS IEC 60502-1 TEKNIK BILGILER lain veriien igletme sicakign Kisa devre sieakligr ‘Test gefilim (AC) Serim sicakligi min Minimum Bakme Yani Gap! ‘Anma geri KULLANIM ALANLARI 70°C 160°C ak 5°C 12x0 g/tkV Mokanik zorlanmanin az oldugu yerlerde siva ustinde, kablo kanaltiginde toprak altinda geboke vo aydinlatma kablosu olarak kullanil. TECHNICAL DATA Permissible operating temperature Shor circuit temperature Test Voltage (AC) Installation temperature minimum, Minimum Bending Radius Rated Voltage USAGE AREAS 70°C 160°C ay 58°C 12D o.g/tkv It is used in places where the mechanical stresses are low. used as surface mounted. in ducts. underground. as mains and lighting cable. ax Operating ‘Seat Seri sake Daim panotan o | (acianv O 0 Aovedaposiik Karine Soma — ER icy e r TO ABEOCOS OEE TEKNIK OZELLIKLER TECHNICAL DATA NYY /YVV (0.6/1kV) Nominal Kablo Dig | Akim Tagua Kapasitesi | UletkenDC | NetAGik | Ambala Kesit | Gapi(Vakiagk) | Havada Toprakta -Ditenci(20°C) — (Yakiagk) milan Ambala fata | Overahbumeterot | CuneniCamyng Canacyin Conduct BC_ NSE WAGRE pay Cross-section Cable (Approx) ar “Ground Resistance al 20°C (Approx) "e ne mit mm A A ohm / km kg/km m rere aX1Sre 1 195 z 121 189 100 100 2.5 v0 121 25 36 7a1 243 100 <_100 Aare 141 3a a7 461 aa7 100 100 2X5 15.4 ° 9 3.08 a7 100 ¢_100 |__AX10 rm 18.90 59 79. 1.83 698 1000 R 1200 axi6 rm 212 79 102 115 968 1000 1300. 4x25 1m 254 108 133 o727 as 1000, 1500. 435 rm 282 129 159 Os24 1882 000 1600 2x50 1m 325 157 1388 0397 2517 1000) 1700. 470m 369 199 232 0268 348s 500, 1500. 4x95 1m 225 24s 280 0198 aris 500 #1600. 120 1m 465 285 318 0.159 5838 500, 1800. 4x150m sha 326 359 O12 7155 250 1500. 2185 m a7 v4 408 0.0991 9009 350, 1600. 44240 rm 65.5 445 473 0.0754 ne 250 1709) exisre 129 W93 2 121 249 1000 R800. 5x25 re ie 25 36 7a a7 1009) R900. SKé re 16.3 34 AT 4.61 449 1000 R 1000 5X60 v7 2 59 Soa 572 1009) W100 Sx10rm 209 59 7 183 as 000 1200, SxI6rm 235 7 102 18 178 1009) R300, | 5X25 rm 28.4 106 133 0.727 W773 1000 R 1500 5x35 1m a8 129 159 0524 2333 1000 R600, 5X50 rm 358 157 188 0307 3040 000 R700. 570m “13 199 22 0268) 2250 500 1600. EX95 1m a77 24s 280 0.198 5798 500 1700. 3x120+m sia 285 a8 0153 7093 250 1500. 5X150 rm 369 326 359 O14 8703 250 1600. Sx185 em 642 4 405 0.0997 10969 250 1800. 5X240 rm 72 44s 473 0.0754 14230 250 1800 7x15. 138 195 2 iz 300, 1000) 800 7925 1m 15 26 36 741 390 000 2900 10xi.5m 168 195 2 121 450 1000, 1000 1042.5 rm 18.4 25 36 7at 530 000 1000 1241.5 172 195 7 121 490 1000, 1000. [120255 rm 189 25 % Tal eo 1000 RT00. 14x15 em 18 19.5 7 121 540, 1000 R1000 4x2'5 rm 197 25 % Tal 710 1000 R100. 15x1.5 mm 183 95 2 121 590 1000) R 1100 (152255 rm 207 25 % Tat 720 1000 e100. 16x15 em 188 Ws 2 121 600 1000) R100 1612'5 rm 207 25 % Tal 800, 1000 R00. 19415 em 197 95 Ey 2 670 1000, 19425 rm 27 25 46 7a 900, 1000 #1200 2a Sem 232 95 7 121 900 1000 R200 24x2'5 rm Qua 25 36 Tal N60 1000 #1900 3X16=10 rm 21 7 102 115/1.83, 910 1000 R200 3225416 rm 245 106 133, 0727/15 1323 1000 #1900 3335416 rm 265 129 159 0.524/1.15 1640 1000 R400 3x50+25 rm 307 157 188 0.367/0.727 2a 1000 R500 3x70+35 rm 347 199 22 0.268/0.524 3056 1000 R600, 3x95050 mm 401 248 220 0193/0387 113 500 R500, 3X120*70 em 43.8 285 a8 0.153/0.268 S217 500 1500. 3X150470 rm a5 226 359 0.124/0.268 $201 500 1600. 3X185095 om 542 4 406 | 0.0991/0.193 7972 250 R500. 3X240+120Tm 60.30 44s a7 0.754/0.153, 10230 250 1500 @borsan cable’ js

You might also like