You are on page 1of 1

'A'

Y 10 @ 200 C/C

T1 EMBANKMENT FILL EMBANKMENT FILL


100

FRL FRL Y 12 @ 200 C/C

200

200
600 THK. FILTER MEDIA (TYP.)
600 THK. FILTER MEDIA (TYP.) 05 05

WEEP HOLES OF 100mm Ø

Ld
AT 1000mm C/C STAGGERED (TYP.)
04
WEEP HOLES OF 100mm Ø
AT 1000mm C/C STAGGERED (TYP.)
EARTH FACE 01 01

04
175

03 + 04 03 + 04
H1

H1
GL GL GL GL

1100
CL*
CL*
02 02

TOP LEVEL OF
B2 B1 EQ EQ EQ RETURN WALL
EQ EQ EQ
07 07
100 100 450

250
H2
H2

(TYP.) (TYP.)
08 08
100

07 07

100

250
06 06 200
250

D2
D2

T2 B2 T2 B1

D1
D1

DETAIL - 'A'
11 09 + 10 10 11 09 + 10 10 (SCALE 1:50)

100 THK. PCC LEVELING COURSE 100 THK. PCC LEVELING COURSE CONCRETE & REINFORCEMENT DETAILS OF
REINFORCEMENT DETAILS OF RETURN WALL CRASH BARRIER OVER RETURN WALL
TYPICAL SECTION RETAINING WALL REINFORCEMENT DETAILS OF RETAINING WALL TYPICAL SECTION RCC RETURN WALL WITH CRASH BARRIER WITH CRASH BARRIER (REINFORCEMENT IN STEM IS NOT SHOWN FOR CLARITY)
(SCALE 1:50) (SCALE 1:50)
(SCALE 1:50) (SCALE 1:50)

NUMERATION AND REINFORCEMENT DETAILS OF RETAINING WALL AND RETURN WALL WITH CRASH BARRIER NOTES:
1. ALL DIMENSIONS ARE IN MM, UNLESS MENTIONED OTHERWISE.
SCHEDULE OF REINFORCEMENT
SCHEDULE OF DIMENSIONS 2. DIMENSIONS ARE NOT TO BE SCALED, ONLY WRITTEN DIMENSIONS
1 2 3 4 5 6 7 8 9 10 11 SHALL BE FOLLOWED
3. GRADE OF REINFORCEMENT SHALL BE Fe-415 CONFIRMING TO IS:1786
HEIGHT OF FILL GRADE DESIGN BASE 4. GRADE OF CONCRETE:
SL.
FROM GROUND OF H1 H2 B1 B2 D1 D2 T1 T2 CL*
NO. PRESSURE a) RETAINING WALL / RETURN WALL UP .......................M-25 / M-30
LEVEL CONCRETE
(mm) (T/Sq.m)
b) RCC CRASH BARRIER..............................................................M-40
c) PCC LEVELING COURSE ..................................................M-15
1. Upto 2000 M25 3500 1500 1675 900 300 600 200 400 1500 14.65 Y 12 @ 150 C/C Y 8 @ 150 C/C - Y 12 @ 150 C/C Y 8 @ 150 C/C Y 12 @ 150 C/C Y 8 @ 150 C/C Y 12 @ 150 C/C Y 12 @ 300 C/C Y 12 @ 300 C/C Y 8 @ 150 C/C
5. COVER TO REINFORCEMENT SHALL BE:
2. 2000 to 3000 M30 5000 2000 1950 1250 300 700 300 550 2100 21.43 Y 16 @ 200 C/C Y 8 @ 125 C/C Y 16 @ 200 C/C Y 16 @ 200 C/C Y 8 @ 125 C/C Y 16 @ 150 C/C Y 8 @ 150 C/C Y 16 @ 150 C/C Y 16 @ 300 C/C Y 16 @ 300 C/C Y 8 @ 150 C/C a) EARTHERN FACE - 75 mm
b) NON-EARTHERN FACE - 40 mm
3. 3000 to 4000 M30 6000 2000 2650 1500 300 800 300 650 2600 22.35 Y 20 @ 220 C/C Y 10 @ 125 C/C Y 20 @ 220 C/C Y 20 @ 220 C/C Y 10 @ 125 C/C Y 16 @ 125 C/C Y 8 @ 150 C/C Y 16 @ 125 C/C Y 16 @ 250 C/C Y 16 @ 250 C/C Y 8 @ 150 C/C
6. EXPOSURE CONDITION ........................MODERATE

4. 4000 to 5000 M30 7000 2000 3050 1750 300 900 300 800 3000 24.46 Y 20 @ 200 C/C Y 10 @ 125 C/C Y 20 @ 200 C/C Y 20 @ 200 C/C Y 10 @ 125 C/C Y 16 @ 100 C/C Y 8 @ 125 C/C Y 16 @ 100 C/C Y 16 @ 200 C/C Y 16 @ 200 C/C Y 8 @ 125 C/C 7. ALL LAPS SHALL BE SUITABLY STAGGERED AND MINIMUM C/C DISTANCE BETWEEN
THE ADJACENT LAPS SHALL BE 1.30 TIMES LAP LENGTH. NOT MORE THAN 50% OF
5. 5000 to 6000 M30 8000 2000 3500 2000 300 950 300 800 3400 26.59 Y 25 @ 220 C/C Y 12 @ 125 C/C Y 25 @ 220 C/C Y 25 @ 220 C/C Y 12 @ 125 C/C Y 16 @ 100 C/C Y 8 @ 125 C/C Y 16 @ 100 C/C Y 16 @ 200 C/C Y 16 @ 200 C/C Y 8 @ 125 C/C REINFORCEMENT SHALL BE LAPPED AT ANY LOCATION
8. SAFE BEARING CAPACITY SHALL BE GREATER THAN MAX. DESIGN
IMPORTANT NOTE:
BASE PRESSURE. SAME SHALL BE ENSURED AT SITE PRIOR TO
IN CASE OF AT THE PROPOSED FOUNDING LEVEL SHOWN IN THE DRAWING SAFE
EXECUTUION
BEARING CAPACITY (SBC) OF SOIL IS LESS THAN DESIGNED BASE PRESSURE THEN
9. EXPANSION JOINT SHALL BE PROVIDED FOR EVERY 40m C/C LENGTH
BETWEEN THE ADJACENT LAPS SHALL BE 1.30 TIMES THE LAP LENGTH
OF RETAINING WALL

CLIENT: CONCESSIONAIRE: PROJECT:

You might also like