Data sheet
105108_en_01 © PHOENIX CONTACT 2012-05-07
1 Description
The plug set is used to connect capacitive loads up to 2,2 µF
to any of the outputs listed in the ordering data for the safety
modules.
Remember to consider the full length of the go and return
path.
2 Ordering data
3 Technical data
General data
Weight 100 g
Ambient temperature (operation) -25 °C ... 55 °C
Ambient temperature (storage/transport) -25 °C ... 70 °C
Permissible humidity (operation) 10 % ... 85 % (Take suitable measures against increased air humidity within the
permitted temperature range.)
Permissible humidity (storage/transport) 10 % ... 85 % (Take suitable measures against increased air humidity within the
permitted temperature range.)
Air pressure (operation) 80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport) 66 kPa ... 108 kPa (up to 3500 m above mean sea level)
Degree of protection IP20
Protection class III, IEC 61140, EN 61140, VDE 0140-1
Connection data
Name Inline connectors
Connection method Spring-cage connection
Conductor cross section solid / stranded 0.2 mm² ... 1.5 mm²
Conductor cross section [AWG] 24 ... 16