You are on page 1of 35

QUALITY INTERNATIONAL (CALIBRATION DIVISION)

has been assessed and accredited in accordance with the standard

ISO/IEC 17025:2017
''General Requirements for the Competence of Testing &
Calibration Laboratories''
for its facilities at
PLOT NO 7A, AVINASH LOGISTIC PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR,
CHHATTISGARH, INDIA

in the field of

CALIBRATION
Certificate Number: CC-3039
Issue Date: 28/08/2022 Valid Until: 27/08/2024

This certificate remains valid for the Scope of Accreditation as specified in the annexure subject to continued
satisfactory compliance to the above standard & the relevant requirements of NABL.
(To see the scope of accreditation of this laboratory, you may also visit NABL website www.nabl-india.org)

Name of Legal Identity : QUALITY INTERNATIONAL

Signed for and on behalf of NABL

N. Venkateswaran
Chief Executive Officer
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 1 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Permanent Facility
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
1 AC Current 50 Hz Multimeter by Direct 1 A to 10 A 0.27 % to 0.22 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
2 AC Current 50 Hz Multimeter by Direct 100 µA to 100 mA 0.35 % to 0.30 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
3 AC Current 50 Hz Multimeter by Direct 100 mA to 1 A 0.30 % to 0.27 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
4 AC Voltage (50 Hz) Multimeter by Direct 10 mV to 100 mV 0.55 % to 0.30 %
Current (< 1
Method
GHz)
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 2 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
5 AC Voltage (50 Hz) Multimeter by Direct 10 V to 100 V 0.24 % to 0.20 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
6 AC Voltage (50 Hz) Multimeter by Direct 100 mV to 10 V 0.30 % to 0.24 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
7 AC Voltage (50 Hz) Multimeter by Direct 100 V to 1000 V 0.25 % to 0.15 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
8 Alternating 2 A to 10 A 0.40 % to 0.35 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
9 Alternating 200 mA to 2000 mA 0.35 % to 0.40 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 3 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
10 Alternating 0.2 mA to 200 mA 0.40 % to 0.35 %
to 1khz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO- Using 5½ Digit
TECHNICAL- Multifunction
AC High Current @
11 Alternating Calibrator with 10 A to 1000 A 2.5 % to 1.5 %
50 Hz
Current (< 1 Current Coil by
GHz) (Source) Direct Method
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
12 Alternating 10 mV to 200 mV 1.1 % to 0.30 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
13 Alternating 20 V to 200 V 0.35 % to 0.38 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
14 Alternating 200 mV to 20 V 0.30 % to 0.35 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
15 Alternating 200 V to 1000 V 0.38 % to 0.27 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 4 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
Using Standard
TECHNICAL-
Decade Capacitance
16 Alternating Capacitance @ 1kHz 1 nF to 100 µF 1.15 % to 1.17 %
Box by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Standard
TECHNICAL-
Decade Inductance
17 Alternating Inductance @ 1kHz 100 µH to 10 H 1.25 % to 1.24 %
Box by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using 6½ Digital
18 DIRECT DC Current Multimeter by Direct 1 A to 10 A 0.25 % to 0.2 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
19 DIRECT DC Current Multimeter by Direct 100 µA to 100 mA 0.60 % to 0.30 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
20 DIRECT DC Current Multimeter by Direct 100 mA to 1 A 0.30 % to 0.25 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
21 DIRECT DC Voltage Multimeter by Direct 10 mV to 100 mV 0.50 % to 0.20 %
CURRENT Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 5 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using 6½ Digital
22 DIRECT DC Voltage Multimeter by Direct 10 V to 1000 V 0.15 % to 0.10 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
23 DIRECT DC Voltage Multimeter by Direct 100 mV to 10 V 0.20 % to 0.15 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
24 DIRECT Resistance Multimeter by Direct 1 ohm to 100 Mohm 0.34 % to 0.50 %
CURRENT Method
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
25 DIRECT DC Current 0.2 mA to 200 mA 0.30 % to 0.20 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
26 DIRECT DC Current 2 A to 10 A 0.30 % to 0.28 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
27 DIRECT DC Current 200 mA to 2000 mA 0.20 % to 0.30 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 6 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO- Using 5½ Digit


TECHNICAL- Multifunction
28 DIRECT DC High Current Calibrator with 10 A to 1000 A 2.25 % to 1.25 %
CURRENT Current Coil by
(Source) Direct Method
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
29 DIRECT DC Voltage 1 mV to 20 mV 1.65 % to 0.30 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
30 DIRECT DC Voltage 20 mV to 200 mV 0.30 % to 0.25 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
31 DIRECT DC Voltage 20 V to 1000 V 0.20 % to 0.15 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
32 DIRECT DC Voltage 200 mV to 20 V 0.25 % to 0.20 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Standard
TECHNICAL-
Decade Resistance
33 DIRECT Resistance 1 ohm to 10 Mohm 0.43 % to 0.15 %
Box by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 7 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Decade
10 Mohm
34 DIRECT Resistance Resistance Box by 0.15 % to 2.8 %
to 1000 Mohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High Precision
B-Type
35 TEMPERATURE Thermometer by 600 °C to 1800 °C 2.0°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
E-Type
36 TEMPERATURE Thermometer by -200 °C to 950 °C 0.9°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
J-Type
37 TEMPERATURE Thermometer by -200 °C to 1200 °C 0.8°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
K-Type
38 TEMPERATURE Thermometer by -200 °C to 1360 °C 0.8 °C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
N-Type
39 TEMPERATURE Thermometer by -200 °C to 1300 °C 1.0°C
Thermocouple
SIMULATION Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 8 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using High Precision
R-Type
40 TEMPERATURE Thermometer by 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
41 TEMPERATURE RTD (PT-100) Thermometer by -200 °C to 800 °C 0.6°C
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
S-Type
42 TEMPERATURE Thermometer by 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
T-Type
43 TEMPERATURE Thermometer by -200 °C to 400 °C 0.8°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Multi Function
B-Type
44 TEMPERATURE Process Calibrator 600 °C to 1800 °C 2.0°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
E-Type
45 TEMPERATURE Process Calibrator -200 °C to 950 °C 0.9°C
Thermocouple
SIMULATION by Direct Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 9 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Multi Function
J-Type
46 TEMPERATURE Process Calibrator -200 °C to 1200 °C 0.8°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
K-Type -200 °C
47 TEMPERATURE Process Calibrator 0.8°C
Thermocouple to 1360 °C
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
N-Type
48 TEMPERATURE Process Calibrator -200 °C to 1300 °C 1.0°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
R-Type
49 TEMPERATURE Process Calibrator 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
50 TEMPERATURE RTD (PT-100) Process Calibrator -200 °C to 800 °C 0.6°C
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
S-Type
51 TEMPERATURE Process Calibrator 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION by Direct Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 10 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Multi Function
T-Type
52 TEMPERATURE Process Calibrator -200 °C to 400 °C 0.8°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digital
53 TIME & Frequency Multimeter by Direct 45 Hz to 1 kHz 0.03 % to 0.18 %
FREQUENCY Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
54 TIME & 1 s to 3600 s 0.06 s to 3.0 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
55 TIME & 3600 s to 36000 s 3.5 s to 33 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
56 TIME & 36000 s to 86400 s 33 s to 80 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
57 TIME & Frequency 45 Hz to 1 kHz 0.35 % to 0.15 %
Calibrator by Direct
FREQUENCY
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 11 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Using Digital
Tachometers, Tachometer and
MECHANICAL-
Digital/ Analog RPM Source By 5000 rpm to 99000
58 ACCELERATION 6rpm
Tachometers, (NON Comparison Method rpm
AND SPEED
Contact Type) By using SANAS
TR45-02
Using Digital
Tachometers, Tachometer and
MECHANICAL-
Digital/ Analog RPM Source By
59 ACCELERATION 50 rpm to 6000 rpm 5.04rpm
Tachometers, Comparison Method
AND SPEED
(Contact Type) By using SANAS
TR45-02
Using Digital
Tachometers, Tachometer and
MECHANICAL-
Digital/ Analog RPM Source By
60 ACCELERATION 10 rpm to 5000 rpm 5.55rpm
Tachometers, (Non Comparison Method
AND SPEED
Contact Type) By using SANAS
TR45-02
MECHANICAL-
DIMENSION Using master Dial
(BASIC Bore Gauge ( Calibration Tester
61 0 to 1 mm 4.1µm
MEASURING Transmission error ) and Plunder Dial by
INSTRUMENT, Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Depth Micrometer
62 By Comparison 0 to 200 mm 6.2µm
MEASURING L.C:- 0.01 mm
Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 12 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL- Using Extensometer


DIMENSION Calibration Fixture &
Extensometer /
(BASIC Digital Dial Gauge
63 LVDT / Displacement 0 to 10 mm 10µm
MEASURING (LC 0.1µm) as per IS
Device (L.C. 1µm)
INSTRUMENT, 12872, ISO9513 &
GAUGE ETC.) ASTM E83
MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC (Digital and
64 By Comparison 0 to 25 mm 1.4µm
MEASURING Analogue) LC - 0.001
Method
INSTRUMENT, mm and Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC (Digital and
65 By Comparison 0 to 300 mm 4.9µm
MEASURING Analogue) LC :- 0.01
Method
INSTRUMENT, mm and Coarser
GAUGE ETC.)
Fixture/moulds,
Cube Moulds /
MECHANICAL-
Flakiness &
DIMENSION
Elongation Gauge, Using Digital Caliper
(BASIC
66 Slump Cone, Core by comparison 0 to 300 mm 40µm
MEASURING
Cutter, Industrial Menthod
INSTRUMENT,
Templates (ID,
GAUGE ETC.)
OD,Height,
Thickness)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 13 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Using Slip Gauge Set
Groove Dial Gauge
(BASIC and Caliper Checker
67 (External) LC :- 0.01 10 mm to 300 mm 11.0 µm
MEASURING By Comparison
mm and Coarser
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
Groove Dial Gauge
(BASIC and Caliper Checker
68 (Internal) LC :- 0.01 10 mm to 300 mm 11µm
MEASURING By Comparison
mm and Coarser
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Caliper
Height Gauge LC :-
(BASIC Checker, Slip Gauge
69 0.01 mm and 0 to 600 mm 12.2µm
MEASURING Set By Comparison
Coarser
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Lever Dial gauge
Using master Dial
(BASIC (Digital analogue)
70 Calibration Tester by 0 to 0.14 mm 2.5µm
MEASURING L.C:- 0.001 mm and
Comparison Method
INSTRUMENT, Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION Lever Dial gauge
Using master Dial
(BASIC (Digital analogue)
71 Calibration Tester by 0 mm to 0.2 mm 3.0µm
MEASURING L.C:- 0.002 mm and
Comparison Method
INSTRUMENT, Coarser
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 14 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Tape & Scale
(BASIC Measuring Tape LC 1 600 x Sqrt (L)µm,
72 Calibrator, by 0 to 30000 mm
MEASURING mm Where 'L' is in m.
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Tape & Scale
(BASIC Pie Tape L.C. 1mm 366 x Sqrt (L)µm,
73 Calibrator, by 0 to 600 mm
MEASURING and coarser Where 'L' is in m.
comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Pistol Caliper LC :-
74 By Comparison 0 to 100 mm 80.2µm
MEASURING 0.1 mm
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Plunger Dial gauge
Using master Dial
(BASIC (Digital analogue)
75 Calibration Tester by 0 to 25 mm 2.5µm
MEASURING L.C:- 0.001 mm and
Comparison Method
INSTRUMENT, Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC
76 Radius Gauge Projector by 0.5 mm to 25 mm 15.3µm
MEASURING
comparison method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 15 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC
77 Snap Gauge and Length Bars By 2 mm to 125 mm 2.0µm
MEASURING
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Tape & Scale
(BASIC
78 Steel Scale LC 1 mm Calibrator, by 0 to 1000 mm 300µm
MEASURING
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC 35 µm
79 Test Sieves Projector By 9µm
MEASURING to 4 mm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Digital Caliper
(BASIC
80 Test Sieves By Comparison 4 mm to 150 mm 19µm
MEASURING
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Profile
(BASIC
81 Thread Pitch Gauge Projector by 0.5 mm to 7 mm 10.2µm
MEASURING
comparison method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 16 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
Vernier Caliper (Dial,
DIMENSION Using Calliper
Digital and
(BASIC Checker and Slip
82 Analogue) 0 mm to 600 mm 12.7µm
MEASURING Gauge Set By
Resolution:- 0.01
INSTRUMENT, Comparison Method
mm and Coarser
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Depth gauge Using Slip Gauge Set
(BASIC
83 LC :- 0.02 mm and By Comparison 0 mm to 200 11.6µm
MEASURING
Coarser Method.
INSTRUMENT,
GAUGE ETC.)
Using Digital
MECHANICAL- Analog Vacuum
Pressure Gauge and
PRESSURE Gauges, Digital
84 Hand pump By -0.90 bar to 0 bar 0.009bar
INDICATING Vacuum Gauges,
Comparison as per
DEVICES Vacuum Indicators
DKD R6-2
Hydraulic Pressure Using Digital
MECHANICAL- (Oil / Water) Analog Pressure Gauge and
PRESSURE Pressure Gauges, Pressure
85 0 to 700 bar 0.95bar
INDICATING Digital Pressure Comparator By
DEVICES Gauges, Pressure Comparison Method
Indicators as per DKD R6-1
Pneumatic Pressure
Using Digital
MECHANICAL- (Dry Air) Analog
Pressure Gauge and
PRESSURE Pressure Gauges,
86 Hand Pump By 0 to 40 bar 0.05bar
INDICATING Digital Pressure
Comparison Method
DEVICES Gauges, Pressure
as per DKD R6-1
Indicators

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 17 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Laboratory Glass
Ware( Volumetric
By Gravimetric
Instruments)
MECHANICAL- Method using
87 Burette, Measuring 20 ml to 100 ml 2ml
VOLUME Weighing Balance of
Cylinder, Flask,
L.C:- 0.0001 g
Beakers (Graduated
/ One Mark Type)
Laboratory Glass
Ware( Volumetric
using Weighing
Instruments)
MECHANICAL- Balance of L.C:-
88 Burette, Measuring 1 ml to 20 ml 0.2 ml
VOLUME 0.0001 g by
Cylinder, Flask,
Gravimetric Method
Beakers (Graduated
/ One Mark Type)
Digital/Analog
Using Master
Thermo
Temperature and
Hygrometers, Data
THERMAL- Humidity Meter with
Loggers, 10 °C
89 SPECIFIC HEAT Sensor, and 0.54°C
Temperature/Humidi to 50 °C
& HUMIDITY Humidity Generator,
ty meters With
by Comparison
Sensor, RH Sensors
method
@ 50%RH
Digital/Analog
Using Master
Thermo
Temperature and
Hygrometers, Data
THERMAL- Humidity Meter with
Loggers,
90 SPECIFIC HEAT Sensor, and 15 %rh to 95 %rh 1.68%rh
Temperature/Humidi
& HUMIDITY Humidity Generator,
ty meters With
by Comparison
Sensor, RH Sensors
method
@ 25°C

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 18 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Using RTD with


Liquid in Glass
THERMAL- Indicator & Oil Bath 50 °C
91 Thermometers, Dial 1°C
TEMPERATURE as source, By to 250 °C
Thermometers
Comparison method
Using RTD with
Liquid in Glass Indicator & Low
THERMAL- -80 °C
92 Thermometers, Dial Temperature Liquid 0.5°C
TEMPERATURE to 50 °C
Thermometers Bath as source, By
Comparison method
RTD’s &
Thermocouple with /
without Indicator, Using RTD with
THERMAL- Temperature Indicator, Oil Bath as 50 °C
93 0.25°C
TEMPERATURE Gauges, Digital Source, By to 250 °C
Temperature Comparison method
Indicators with
Probe, Data Loggers.
RTD’s &
Thermocouple with /
Using RTD with
without Indicator,
Indicator & Low
THERMAL- Temperature -80 °C
94 Temperature Liquid 0.34°C
TEMPERATURE Gauges, Digital to 50 °C
Bath as source, By
Temperature
Comparison method
Indicators with
Probe, Data Loggers.

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 19 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

RTD’s (upto 400°C)


& Thermocouple
Using S-type
with / without
Thermocouple with
Indicator,
THERMAL- Indicator and Dry 250 °C
95 Temperature 2.51°C
TEMPERATURE bath & Furnace as to 1200 °C
Gauges, Digital
source, By
Temperature
Comparison method
Indicators with
Probe, Data Loggers.

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 20 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Site Facility
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
1 AC Current 50 Hz Multimeter by Direct 1 A to 10 A 0.27 % to 0.22 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
2 AC Current 50 Hz Multimeter by Direct 100 µA to 100 mA 0.35 % to 0.30 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
3 AC Current 50 Hz Multimeter by Direct 100 mA to 1 A 0.30 % to 0.27 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
4 AC Voltage (50 Hz) Multimeter by Direct 10 mV to 100 mV 0.55 % to 0.30 %
Current (< 1
Method
GHz)
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 21 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
5 AC Voltage (50 Hz) Multimeter by Direct 10 V to 100 V 0.24 % to 0.20 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
6 AC Voltage (50 Hz) Multimeter by Direct 100 mV to 10 V 0.30 % to 0.24 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
TECHNICAL-
Using 6½ Digital
Alternating
7 AC Voltage (50 Hz) Multimeter by Direct 100 V to 1000 V 0.25 % to 0.15 %
Current (< 1
Method
GHz)
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
8 Alternating 2 A to 10 A 0.40 % to 0.35 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
9 Alternating 200 mA to 2000 mA 0.35 % to 0.40 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 22 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Current @ (50 Hz Multifunction
10 Alternating 0.2 mA to 200 mA 0.40 % to 0.35 %
to 1khz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO- Using 5½ Digit
TECHNICAL- Multifunction
AC High Current @
11 Alternating Calibrator with 10 A to 1000 A 2.5 % to 1.5 %
50 Hz
Current (< 1 Current Coil by
GHz) (Source) Direct Method
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
12 Alternating 10 mV to 200 mV 1.1 % to 0.30 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
13 Alternating 20 V to 200 V 0.35 % to 0.38 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
14 Alternating 200 mV to 20 V 0.30 % to 0.35 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
AC Voltage @ (50 Hz Multifunction
15 Alternating 200 V to 1000 V 0.38 % to 0.27 %
to 1 kHz) Calibrator by Direct
Current (< 1
Method
GHz) (Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 23 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
Using Standard
TECHNICAL-
Decade Capacitance
16 Alternating Capacitance @ 1kHz 1 nF to 100 µF 1.15 % to 1.17 %
Box by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
Using Standard
TECHNICAL-
Decade Inductance
17 Alternating Inductance @ 1kHz 100 µH to 10 H 1.25 % to 1.24 %
Box by Direct
Current (< 1
Method
GHz) (Source)
ELECTRO-
TECHNICAL- Using 6½ Digital
18 DIRECT DC Current Multimeter by Direct 1 A to 10 A 0.25 % to 0.2 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
19 DIRECT DC Current Multimeter by Direct 100 µA to 100 mA 0.60 % to 0.30 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
20 DIRECT DC Current Multimeter by Direct 100 mA to 1 A 0.30 % to 0.25 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
21 DIRECT DC Voltage Multimeter by Direct 10 mV to 100 mV 0.50 % to 0.20 %
CURRENT Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 24 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using 6½ Digital
22 DIRECT DC Voltage Multimeter by Direct 10 V to 1000 V 0.15 % to 0.10 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
23 DIRECT DC Voltage Multimeter by Direct 100 mV to 10 V 0.20 % to 0.15 %
CURRENT Method
(Measure)
ELECTRO-
TECHNICAL- Using 6½ Digital
24 DIRECT Resistance Multimeter by Direct 1 ohm to 100 Mohm 0.34 % to 0.50 %
CURRENT Method
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
25 DIRECT DC Current 0.2 mA to 200 mA 0.30 % to 0.20 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
26 DIRECT DC Current 2 A to 10 A 0.30 % to 0.28 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
27 DIRECT DC Current 200 mA to 2000 mA 0.20 % to 0.30 %
Calibrator by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 25 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO- Using 5½ Digit


TECHNICAL- Multifunction
28 DIRECT DC High Current Calibrator with 10 A to 1000 A 2.25 % to 1.25 %
CURRENT Current Coil by
(Source) Direct Method
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
29 DIRECT DC Voltage 1 mV to 20 mV 1.65 % to 0.30 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
30 DIRECT DC Voltage 20 mV to 200 mV 0.30 % to 0.25 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
31 DIRECT DC Voltage 20 V to 1000 V 0.20 % to 0.15 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
32 DIRECT DC Voltage 200 mV to 20 V 0.25 % to 0.20 %
Calibrator by Direct
CURRENT
Method
(Source)
ELECTRO-
Using Standard
TECHNICAL-
Decade Resistance
33 DIRECT Resistance 1 ohm to 10 Mohm 0.43 % to 0.15 %
Box by Direct
CURRENT
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 26 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Decade
10 Mohm
34 DIRECT Resistance Resistance Box by 0.15 % to 2.8 %
to 1000 Mohm
CURRENT Direct Method
(Source)
ELECTRO-
TECHNICAL- Using High Precision
B-Type
35 TEMPERATURE Thermometer by 600 °C to 1800 °C 2.0°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
E-Type
36 TEMPERATURE Thermometer by -200 °C to 950 °C 0.9°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
J-Type
37 TEMPERATURE Thermometer by -200 °C to 1200 °C 0.8°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
K-Type
38 TEMPERATURE Thermometer by -200 °C to 1360 °C 0.8 °C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
N-Type
39 TEMPERATURE Thermometer by -200 °C to 1300 °C 1.0°C
Thermocouple
SIMULATION Direct Method
(Measure)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 27 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using High Precision
R-Type
40 TEMPERATURE Thermometer by 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
41 TEMPERATURE RTD (PT-100) Thermometer by -200 °C to 800 °C 0.6°C
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
S-Type
42 TEMPERATURE Thermometer by 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using High Precision
T-Type
43 TEMPERATURE Thermometer by -200 °C to 400 °C 0.8°C
Thermocouple
SIMULATION Direct Method
(Measure)
ELECTRO-
TECHNICAL- Using Multi Function
B-Type
44 TEMPERATURE Process Calibrator 600 °C to 1800 °C 2.0°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
E-Type
45 TEMPERATURE Process Calibrator -200 °C to 950 °C 0.9°C
Thermocouple
SIMULATION by Direct Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 28 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Multi Function
J-Type
46 TEMPERATURE Process Calibrator -200 °C to 1200 °C 0.8°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
K-Type -200 °C
47 TEMPERATURE Process Calibrator 0.8°C
Thermocouple to 1360 °C
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
N-Type
48 TEMPERATURE Process Calibrator -200 °C to 1300 °C 1.0°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
R-Type
49 TEMPERATURE Process Calibrator 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
50 TEMPERATURE RTD (PT-100) Process Calibrator -200 °C to 800 °C 0.6°C
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using Multi Function
S-Type
51 TEMPERATURE Process Calibrator 0 °C to 1750 °C 1.5°C
Thermocouple
SIMULATION by Direct Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 29 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

ELECTRO-
TECHNICAL- Using Multi Function
T-Type
52 TEMPERATURE Process Calibrator -200 °C to 400 °C 0.8°C
Thermocouple
SIMULATION by Direct Method
(Source)
ELECTRO-
TECHNICAL- Using 6½ Digital
53 TIME & Frequency Multimeter by Direct 45 Hz to 1 kHz 0.03 % to 0.18 %
FREQUENCY Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
54 TIME & 1 s to 3600 s 0.06 s to 3.0 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
55 TIME & 3600 s to 36000 s 3.5 s to 33 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Time Interval (Timer, Using Digital Time
TECHNICAL-
Stopwatch,Time Interval Calibrator
56 TIME & 36000 s to 86400 s 33 s to 80 s
Interval by Comparison
FREQUENCY
Meter/Calibrator) Method
(Measure)
ELECTRO-
Using 5½ Digit
TECHNICAL-
Multifunction
57 TIME & Frequency 45 Hz to 1 kHz 0.35 % to 0.15 %
Calibrator by Direct
FREQUENCY
Method
(Source)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 30 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

RPM Sources,
Centrifuges( up to
MECHANICAL- 10000rpm), Stirrers, Using Digital
1000 rpm to 99000
58 ACCELERATION Rotating Machine & Tachometer by 6rpm
rpm
AND SPEED RPM Generators Comparison Method
(Non Contact
method)
RPM Sources,
Centrifuges, Stirrers,
MECHANICAL- Using Digital
Rotating Machine &
59 ACCELERATION Tachometer by 50 rpm to 1000 rpm 2.6rpm
RPM Generators
AND SPEED Comparison Method
(Non Contact
method)
MECHANICAL- Using Extensometer
DIMENSION Calibration Fixture &
Extensometer /
(BASIC Digital Dial Gauge
60 LVDT / Displacement 0 to 10 mm 10µm
MEASURING (LC 0.1µm) as per IS
Device (L.C. 1µm)
INSTRUMENT, 12872, ISO9513 &
GAUGE ETC.) ASTM E83
Using Digital
MECHANICAL- Analog Vacuum
Pressure Gauge and
PRESSURE Gauges, Digital
61 Hand pump By -0.90 bar to 0 bar 0.009bar
INDICATING Vacuum Gauges,
Comparison as per
DEVICES Vacuum Indicators
DKD R6-2
Hydraulic Pressure Using Digital
MECHANICAL- (Oil / Water) Analog Pressure Gauge and
PRESSURE Pressure Gauges, Pressure
62 0 to 700 bar 0.95bar
INDICATING Digital Pressure Comparator By
DEVICES Gauges, Pressure Comparison Method
Indicators as per DKD R6-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 31 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Pneumatic Pressure
Using Digital
MECHANICAL- (Dry Air) Analog
Pressure Gauge and
PRESSURE Pressure Gauges,
63 Hand Pump By 0 to 40 bar 0.05bar
INDICATING Digital Pressure
Comparison Method
DEVICES Gauges, Pressure
as per DKD R6-1
Indicators
Force Verification of Using Force Proving
MECHANICAL-
Static Uniaxial Instruments (Load
UTM, TENSION
Testing Machines: Cell Device / Proving
CREEP AND
64 Calibration of Rings of Class 0.5 & 0.5 kN to 100 kN 1.10%
TORSION
Machines of Class 1) As per IS 1828
TESTING
0.5 & Coarser (PART-1) / ISO 7500
MACHINE
(Tension Mode) (PART-1)
Force Verification of Using Force Proving
MECHANICAL-
Static Uniaxial Instruments (Load
UTM, TENSION
Testing Machines: Cell Device / Proving
CREEP AND
65 Calibration of Rings of Class 0.5 & 0.5 kN to 2000 kN 1.11%
TORSION
Machines of Class 1 1) As per IS 1828
TESTING
& Coarser (PART-1) / ISO 7500
MACHINE
(Compression Mode) (PART-1)
Using Standard
MECHANICAL- Weight(s) of E2
Weighing Balance d
WEIGHING Class (1 mg to 200
66 = 0.001 g Class II 10 mg to 220 g 1.5mg
SCALE AND gram) and F1 (500 g
and Coarser
BALANCE to 20 Kg) Method as
per OMIL R-76-1

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 32 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Using Standard
MECHANICAL- Weight(s) of E2
Weighing Balance d
WEIGHING Class (1 mg to 200
67 = 0.01 g Class III 100 mg to 600 g 30mg
SCALE AND gram) and F1 (500 g
and Coarser
BALANCE to 20 Kg) Method as
per OMIL R-76-1
Using Standard
MECHANICAL- Weight(s) of E2
Weighing Balance d
WEIGHING Class (1 mg to 200
68 = 1 g Class III and 1 g to 30 kg 3.0g
SCALE AND gram) and F1 (500 g
Coarser
BALANCE to 20 Kg) Method as
per OMIL R-76-1
Using Standard
MECHANICAL- Weight(s) of E2
Weighing Balance d
WEIGHING Class (1 mg to 200
69 = 10 g Class III and 0.1 kg to 100 kg 20g
SCALE AND gram) and F1 (500 g
Coarser
BALANCE to 20 Kg) Method as
per OMIL R-76-1
Temperature
Indicator of
Environmental Using Master
THERMAL- Chambers, Humidity Temperature and
70 SPECIFIC HEAT Chambers,Temperat Humidity Meter with 15 %rh to 95 %rh 1.5%rh
& HUMIDITY ure and Humidity Sensor, by
Chambers, Humidity Comparison method
Generators. (Single
Position) @ 25°C

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 33 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Temperature
Indicator with sensor
of Environmental Using Master
THERMAL- Chambers, Humidity Temperature and
71 SPECIFIC HEAT Chambers,Temperat Humidity Meter with 10 °C to 50 °C 0.3°C
& HUMIDITY ure and Humidity Sensor, by
Chambers, Humidity Comparison method
Generators. (Single
Position) @ 50%RH
RTD’s &
Thermocouple with /
without Indicator, Using RTD with
THERMAL- Temperature Indicator, Oil Bath as 50 °C
72 0.25°C
TEMPERATURE Gauges, Digital Source, By to 250 °C
Temperature Comparison method
Indicators with
Probe, Data Loggers.
RTD’s (upto 400°C)
& Thermocouple
Using S-type
with / without
Thermocouple with
Indicator,
THERMAL- Indicator and Dry 250 °C
73 Temperature 2.51°C
TEMPERATURE bath & Furnace as to 1200 °C
Gauges, Digital
source, By
Temperature
Comparison method
Indicators with
Probe, Data Loggers.

This is annexure to 'Certificate of Accreditation' and does not require any signature.
QUALITY INTERNATIONAL (CALIBRATION DIVISION), PLOT NO 7A, AVINASH LOGISTIC
Laboratory Name : PARK, PHASE-II, SILTARA INDUSTRIAL AREA, SKS ROAD, RAIPUR, CHHATTISGARH,
INDIA
Accreditation Standard ISO/IEC 17025:2017
Certificate Number CC-3039 Page No 34 of 34
Validity 28/08/2022 to 27/08/2024 Last Amended on 14/12/2022

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Temperature
Indicators With S-Type
THERMAL- Sensor of Dry Baths, Thermocouple with 250 °C
74 3.73°C
TEMPERATURE Furnaces, Oven(upto Indicator by to 1200 °C
400°C) (Single comparison method.
Position)
Temperature
Indicators With
Sensor of Dry Block
Furnace, Ovens, Using RTD with
THERMAL- 50 °C
75 Incubators, BOD’s, Indicator by 0.63 °C
TEMPERATURE to 250 °C
Environmental comparison Method
Chambers, Melting
Point Apparatus
(Single position)
Temperature
Indicators With Using RTD Sensor
THERMAL- -25 °C
76 Sensor of Freezers, with Indicator By 0.63 °C
TEMPERATURE to 10 °C
Refrigerators (Single Comparison Method.
Position)
* CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, using a coverage factor of k = 2.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

You might also like