PLUMBING NOTES:

DS ABOVE

DS ABOVE

DS ABOVE
1. ALL PLUMBING HERE SHALL BE EXECUTED ACCORDING T THE REQUIREMENTS OF
THE PHILIPPINE PLUMBING CODE & THE RULES & REGULATIONS OF THE LOCAL
G O V E R N M E N T .
2 . C OO RD IN AT E T HE DRA W I NG W I T H T HE O T HE R REL AT E D DRA W IN GS AN D

GV
SPECIFICATI ONS, THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY

HBF

VSTR

VSTR
WT D I S C R E P A N C Y F O U N D H E R E I N .
GV

C
3. PIPES SHALL BE WITH THE PRIOR APPROVAL OF THE ARCHITECT AND THE

O
CB CB DS ABOVE E N G I N E E R .
GV
DS ABOVE

RISER

LAV

LAV
WC

WC
F F FD

FD
KS KS

KSF
4. HE PROPOSED SANITARY UTILITIES SHALL CONFORM THE ACTUAL LOCATION,

WC

WC
LF

LF
PT

SH

SH
CO CO DEPTH AND INVERT ELEVATION OF THE EXISTING PIPES AND STRUCTURE AS
V E R I F I E D B Y T H E C O N T R A C T O R .

CO
FD FD
VSTR 5. THE SLOPES FOR HORIZONTAL BRANCHES (SEWER) SHALL MAINTAIN 1% AS
M I N I M U M U N L E S S A S N O T I F I E D O T H E R W I S E .
SEPTIC 6. ALL FIXTURES SHALL BE VENTED, UNLESS OTHERWISE INDICATED.

CO
VAULT 7. AIR CHAMBER; ALL INDIVIDUAL BRANCHES TO FIXTURE OR GROUP OF FIXTURES

WC
WC AND /OR EQUIPMENT SHALL BE PROVIDED WITH AIR CHAMBER CAPPED VERTICAL
CB

FD
DS ABOVE
F

CB P I P E E X T E N S I O N O F D I M E N S I O N A S I N D E T A I L .
DS ABOVE 8. ALL SEWER LINES SHALL BE UPVC SERIES 1000 BY "NELTEX", "ATLANTA" OR
A P P R O V E D E Q U I V A L E N T
9. ALL VENT STACKS (VSTR) SHALL BE UPVC SERIES 1000 "NELTEX", "ATLANTA" OR
A P P R O V E D E Q U I V A L E N T .
10. ALL CIRCUIT VENT (CV) SHALL BE UPVC SERIES 1000 "NELTEX", "ATLANTA" OR
DS ABOVE
A P P R O V E D E Q U I V A L E N T .
11. ALL DOWNSPOUTS (DS) SHALL BE DIA 2" PVC SERIES 1000 "NELTEX", "ATLANTA" OR
CONCRETE CANOPY
DS ABOVE
CONCRETE CANOPY A P P R O V E D E Q U I V A L E N T .
12. ALL COLD WATER LINES SHALL BE DIA 1 / 2 " PVC PIPE (BLUE PIPE).
UP

UP
CB AD
CB PLUMBING LEGEND
CONCRETE CANOPY CONCRETE CANOPY

SEWER PIPING
DS ABOVE KS KITCHEN SINK

DS ABOVE
CO SEWER PIPE CLEAN - OUT
HB LAV LAVATORY DRAIN
GV SE CON D FLOO R COLD SECOND FLOOR DRAINAGE AND VP Ø2" VENT PIPE
Ø 4" OR 3" PVC DRAINAGE PIPE FD FLOOR DRAIN
WM WATER PIPING LAY-OUT SANITARY PIPING LAY-OUT
CV SCALE 1:100 MTRS SCALE 1:100 MTRS Ø 2" PVC DRAINAGE PIPE AD AREA DRAIN
CO DRAINAGE PIPE CLEAN - OUT DS DOWN SPOUT

T A P T O BTD BATH TUB DRAIN


WATER MAIN TO STREET TO STREET
DRAINAGE DRAINAGE COLD WATER PIPE RISER P I P E R I S E R
S Y S T E M S Y S T E M L I N E
SH SHOWER HEAD SHV SHOWER HEAD VALVE
F F A U C E T BTF BATH TUB FAUCET
GROUND FLOOR COLD GROUND FLOOR DRAINAGE AND

GV
KSF KITCHEN SINK FAUCET
G A T E V A L V E
LF LAVATORY FAUCET
WATER PIPING LAY-OUT SANITARY PIPING LAY-OUT

CV
SCALE 1:100 MTRS SCALE 1:100 MTRS HBF HOSE BIB FAUCET C H E C K V A L V E
WC WATER CLOSET
WATER METER

WM
DS
DS

DS
TR
VS DS
SH R
SH LF V ST
DS
SH DS
WC 0.500
SH
V
V 3.500
F 0.125 0.125 0.125 0.125
LF F 0.900 0.900 1.200 0.300

DS
0.500 0.500 0.500
WC TR 0.100 0.100

0.125
VS
LA .05 .05
V
DS .05 .05
WC CO
FD DIA 4' DI A 4'
FD P V C P V C

1.500
1.250
LA FD
V
WC 0.5000 I N L E T OUTLET
CO DS P I P E P I P E
HB FD A
O
C

F A
CO CO CO
AD INLET OUTLET
INLET

0.125
PLAN VIEW

IC
T

T
UL

P
E
CB VA

S
3.500 CATCH BASIN PLAN
KS
F 0.125 0.125 0.125 0.125
CO 0.900 0.900 1.200
HB KS 0.500 0.500 0.500
GV M
GV W KS CB TOP OF SV
CO CO CO

0.300
GV CV

VARIES ON

INLET PIPE
SLOPE OF
CO

ACTUAL
C O V E R
F

AIRGAP

AIRGAP

AIRGAP
0.500
T

VARIES

VARIES

VARIES
W

TA
G

NGL / FGL
WC P
WA TO
T

T INLET PIPES
P

MA ER 0.300
IN CB FD CB INLET
WC Ø5" S-600 PVC Ø5" S-600 PVC Ø5" S-600 PVC
INLET PIPE INLET PIPE INLET PIPE 0.100 0.100 DIA 10MM
CO
PLASTERED 5" CHB PLASTERED 5" CHB PLASTERED 5" CHB
SV CHAMBER SV CHAMBER SV CHAMBER .05 .05 MH COVER
PARTITION PARTITION PARTITION HANDLE
CB T .05 .05
ST O NGL
DR REE DIA 10MM

2.50
A T
SY INAG W A L L
ST E
EM LEACHING LEACHING DIGESTIVE VERTICAL
CB CHAMBER CHAMBER CHAMBER B A R S
ISOMETRIC VIEW OF COLD WATER DIA 10MM

VARIES
P I P I N G L A Y - O U T W A L L
HORIZONTAL
SCALE 1:100 MTRS
SV FLOOR
T INLET B A R S
S O S L A B
DRTRE SLOPE

0.150
SLOPE
AIN ET F I N I S H
SY AG DI A 4' OUTLET
ST E BOT. OF SV P V C
EM
I N L E T DI A 4'
SECTION VIEW P I P E P V C
CATCH BASIN DETAIL
OUTLET
ISOMETRIC VIEW OF DRAINAGE P I P E
AND SANITARY PIPING LAY-OUT
SCALE 1:100 MTRS
SEPTIC VAULT PLAN AND DETAIL
SCALE 1:40 MTRS
CATCH BASIN PLAN AND DETAIL
SCALE 1:40 MTRS

LOGO SANITARY ENGINEER PROJECT TITLE BUILDING OWNER NO R E V I S I O N S DATE SHEET CONTENTS SHEET NUMBER
1 COLD WATER PIPING LAY-OUT
P R O P O S E D O F T W O - S T O R E Y 2 DRAINAGE AND SANITARY PIPING LAY-OUT P-01
ENGR. JENNA LIZA M. LAYNO MR. EDUARD JOSEPH M. DELA CRUZ 3 ISOMETRIC VIEW COLD WATER PIPING LAY-OUT
R E S I D E N T I A L B U I L D I N G 4 ISOMETRIC VIEW DRAINAGE AND SANITARY PIPING LAY-OUT
LOCATION OF CONSTRUCTION 5 PAGE
PRC: 14451 ADDRESS SEPTIC VAULT PLAN AND DETAIL
PTR. 0000000 6 CATCH BASIN PLAN AND DETAIL
DATE : 01 - 03 - 24 A. H. BANZON ST., BALANGA CITY, BATAAN CATANING, BALANGA CITY, BATAAN 7 NOTES 01
PLACE: BALANGA CITY, BATAAN 8 LEGEND

You might also like