You are on page 1of 1

TỦ ĐIỆN TRẠM SẠC TĐ.

TSXĐ
TỪ TRẠM BIẾN ÁP TBA MỚI CẤP ĐẾN
CÁP CẤP NGUỒN CU/XLPE/PVC (3x1Cx240)+(1CX120)MM2+E120MM2
/SOURCE CABLE LUỒN TRONG 01 ỐNG HDPE D195/150, CHÔN NGẦM

CHỈ THỊ
CC TĐ.TSXĐ
3x2A (1400x800x200)mm

TỦ ĐIỆN LOẠI LẮP NGOÀI TRỜI


MCCB
MÁY CẮT TỔNG
3P
/ MAIN CB
400A
50kA
Pđ = 150 kW , Kđt = 1
THANH CÁI Ptt = 150 kW
/ BUS BAR

MÁY CẮT LỘ RA MCCB RCBO MCB MCB MCB


4P 2P 1P 1P 1P
/ OUTGOING CB
400A 16A 10A 10A 20A
42kA 6kA 6kA 6kA 6kA
30mA
ĐIỀU KHIỂN
/ CONTROL

LỘ RA / OUT CODE

® ¾

Cu/XLPE/PVC (3x1Cx185+1Cx95)mm2+E(1x95)mm2
CHÔN NGẦM, ỐNG HDPE D160/125

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2

Cu/PVC/PVC (2x2.5)+E(1x2.5)mm2
CHÔN NGẦM, ỐNG HDPE D32/25

CHÔN NGẦM, ỐNG HDPE D32/25

CHÔN NGẦM, ỐNG HDPE D32/25


CÁP NGUỒN/
CÁCH LẮP ĐẶT
CABLE /
HOW TO INSTALL

PHA ABC A B C A
/PHASE

CẤP NGUỒN HỆ THỐNG ĐIỆN NHẸ


DỰ PHÒNG KHÔNG GIAN LẮP ĐẶT
TRỤ SẠC DC 150KW (TRỤ 1)

CHO TRỤ MÔ HÌNH 60KW


PHỤ TẢI

BIỂN NHẬN DIỆN


/LOAD

CHIẾU SÁNG

DỰ PHÒNG
CÔNG SUẤT (kW) /CAP (kW) 150.0 - - - - -

GHI CHÚ:
- CÁP TRUNG THẾ TỪ ĐIỂM ĐẤU NỐI ĐIỆN LỰC ĐẾN TRẠM BIẾN ÁP XÂY MỚI TẠM TÍNH 250M,
SỐ LƯỢNG CHÍNH XÁC THEO THỰC TẾ THI CÔNG
- KÍCH THƯỚC TỦ ĐIỆN PHÂN PHỐI TRẠM SẠC XE SẼ ĐƯỢC CẬP NHẬT
THEO THỰC TẾ THIẾT BỊ NHÀ THẦU CHẾ TẠO
- KÍCH THƯỚC TỦ ĐIỆN PHÂN PHỐI SẼ ĐƯỢC THAY ĐỔI THEO THIẾT BỊ NHÀ THẦU SẢN XUẤT
- ĐỐI VỚI TRẠM SẠC CẤP ĐIỆN TỪ ĐIỆN LỰC THÌ KHÔNG CẦN TRANG BỊ CÔNG TƠ ĐIỆN
- CHI TIẾT TRẠM BIẾN ÁP XEM HỒ SƠ TRẠM BIẾN ÁP
- CẤU HÌNH THAY ĐỔI THEO THỎA THUẬN ĐẤU NỐI VÀ YÊU CẦU ĐIỆN LỰC ĐỊA PHƯƠNG