GENERAL NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE


SPECIFIED.
2. POWER SUPPLY SECURITY SYSTEM TO BE TAKEN FROM
500.00 NEAREST POWER SOURCES (UPS) (UN-INTERRUPTED
68.50 77.00 48.00 21.50 71.00 71.00 70.00 64.00 POWER SUPPLY).
HH-14 2.00 N: 26° 29.800' HH-13 N: 26° 29.811' HH-12 HH-11 N: 26° 29.821' N: 26° 29.852' 3. MINIMUM SIZE OF PVC / EMT / RGS FLEXIBLE CONDUIT
HH-44 HH-43 N: 26° 29.833' HH-42 N: 26° 29.842' HH-41 E: 049° 49.438'
N: 26° 29.753' E: 049° 49.228' E: 049° 49.273' E: 049° 49.316' E: 049° 49.537' E: 049° 49.398' SHALL BE 3/4 INCH.
E: 049° 49.201' 0.79 4. ALL CABLES AND DEVICES SHALL BE LABELED IN
N: 26° 29.754' N: 26° 29.819' N: 26° 29.832' N: 26° 29.843'
FC-28 N: 26° 29.801' FC-26 N: 26° 29.822' FC-17 FC-16 FC-15 N: 26° 29.852' ACCORDANCE WITH THE RELEVANT EIA/TIA
E: 049° 49.199' E: 049° 49.228' FC-27 E: 049° 49.300' N: 26° 29.813' FC-25 E: 049° 49.535' E: 049° 49.396' E: 049° 49.437' FC-14-CAM-042
N: 26° 29.812' E: 049° 49.302' E: 049° 49.316' HH-40 SPECIFICATIONS.
FC-28-CAM-083 E: 049° 49.272' FC-14-CAM-041 5. MAXIMUM 3 DATA CABLE TO BE PULL FROM 3/4" CONDUIT.
FC-27-CAM-073 FC-24-CAM-051 FC-24 FC-25-CAM-049 FC-17-CAM-047 FC-16-CAM-045 FC-15-CAM-043
N: 26° 29.861'
FC-28-CAM-084 FC-14-CAM-040 6. NETWORK SWITCH SHALL BE PLACED IN IT & FILED
FC-26-CAM-071 FC-25-CAM-050 FC-16-CAM-046 E: 049° 49.473'
FC-27-CAM-074 FC-17-CAM-048 EQUIPMENT CABINET.
FC-15-CAM-044
FC-28-CAM-085 FC-26-CAM-072 7. ALL OUTDOOR UNDER GROUND CABLES SHOULD BE
FC-24-CAM-052 FC-14
INSTALLED IN PVC SLEEVES.
N: 26° 29.859'
E: 049° 49.475' CCTV SYSTEM:
1. ALL CAMERAS AND ACCESS CONTROL PANEL SHALL BE
CONNECTED TO POE NETWORK SWITCH.
69.00

70.00
2. ALL DATA CABLING WILL BE DONE WITH CAT-6 CABLE FOR
CCTV AND SEPARATE CABLES TO BE CONSIDER FOR
EQUIPMENT CONNECTION.

70.60
WAREHOUSE STORAGE 3. MAXIMUM DISTANCE OF CAMERA FROM NETWORK SWITCH

104.00
SHALL BE MAXIMUM 90 METERS.
4. CCTV IP CAMERA WILL BE POWERED THROUGH IP BASED

100.31
SAND AREA WAREHOUSE STORAGE AREA
POE SWITCH.
5. OUTDOOR FIXED CAMERA SHALL BE INSTALLED WITHIN 5
METER FROM THE FLOOR LEVEL.
6. OUTDOOR RATED CABLE TO BE USED IN OUTDOOR AREA.

HH-15
2.00
N: 26° 29.719'
101.70 98.00 SAND AREA FC-13-CAM-039
FC-13-CAM-038
7. FIBER OPTIC CABLING TO BE DONE FOR NETWORK
COMMUNICATION.
N: 26° 29.719'
E: 049° 49.211'
FC-29 E: 049° 49.210' SECURITY EQUIPMENT ROOM:
FC-29-CAM-086
FC-33-CAM-076 FC-13 HH-39 1. 2ALL SECURITY EQUIPMENT SHALL BE PLACED IN
FC-23-CAM-053
FC-29-CAM-087 EQUIPMENT ROOM.
FC-33-CAM-075 N: 26° 29.825' N: 26° 29.824' 2. 3 DISPLAY OF VIDEOS AND ALARMS EVENTS SHALL BE
FC-23-CAM-054
FC-33 FC-23 E: 049° 49.486' E: 049° 49.485' PROVIDED IN GUARD ROOM.
N: 26° 29.763' N: 26° 29.784'
E: 049° 49.258' E: 049° 49.311'
N: 26° 29.764' SECURITY SYSTEM LEGENDS
HH-10 E: 049° 49.257' HH-09
FC-18-CAM-059 FC-18-CAM-061 FC-19-CAM-063 FC-19-CAM-065

20.40
FOR DETAIL REFER TO DRAWING N: 26° 29.785' 100MM HDPE DUCT
NO.EX00-CCTV-DT-XX0001 -001001 E: 049° 49.311' FC-18-CAM-060 FC-18-CAM-062 FC-19-CAM-064 FC-19-CAM-066
110MM PVC PIPE
N: 26° 29.772' N: 26° 29.788'
134.00 WARNING TAPE
FC-18 FC-19
66.60

E: 049° 49.314' E: 049° 49.387'

69.00
N: 26° 29.789' N: 26° 29.766' CONCRETE TILES
N: 26° 29.765' E: 049° 49.394'
HH-05 HH-06 E: 049° 49.386' E: 049° 49.393' HH-07
POWER CABLE

FOC SENSING CABLE

49.60
SWITCH (FC)

NETWORK SWITCH 48P (INDOOR)

54.20
CCTV BILL OF MATERIAL QTY
N: 26° 29.713' SR # PART NO. DESCRIPTION FC-12-CAM-037 CORE SWITCH
N: 26° 29.713'
E: 049° 49.212' FC-30 E: 049° 49.211' FC-12-CAM-036
1 XX BULLET CAMERA 101 FILED CABINET (FC)
HH-16
FC-30-CAM-088 FC-32-CAM-077
FC-31-CAM-080
FC-22-CAM-056 TOTAL CAMERA 306 CHAIN LINK FENCE
FC-30-CAM-089 FC-31-CAM-081 FC-32-CAM-079 FC-32-CAM-078
FC-12 HH-38
10.50

FC-22-CAM-057 FC-22 N: 26° 29.797' HH-08


N: 26° 29.723'
FC-31-CAM-082 FC-31 E: 049° 49.249' FC-32 E: 049° 49.430' N: 26° 29.798' N: 26° 29.789' N: 26° 29.787'
N: 26° 29.744' QTY
HH-17
N: 26° 29.714' N: 26° 29.731'
E: 049° 49.325' FC-20 E: 049° 49.430'
BILL OF MATERIAL E: 049° 49.497' E: 049° 49.495' REFERENCE DRAWING:
E: 049° 49.214' E: 049° 49.281'
2.00 SR # PART NO. DESCRIPTION SL
FC-20-CAM-067 NO DRAWING NUMBER DESCRIPTION
HH-18 N: 26° 29.724' HH-03 N: 26° 29.733' N: 26° 29.743' HH-04 FC-20-CAM-069
E: 049° 49.248' E: 049° 49.279' E: 049° 49.325' FC-22-CAM-055 FC-20-CAM-068 36 FIBER CABLE CONDUIT EXTERNAL NETWORK
1 XX POLES
61.00 58.30 75.50 FC-22-CAM-058 FC-20-CAM-070 1 EX00-CCTV-CN-XX0001 -001005
GENERAL LAYOUT

2.00 2 XX FIELD CABINET 37 POWER CABLE CONDUIT EXTERNAL NETWORK


2 EX00-CCTV-CN-XX0002 -001005
GENERAL LAYOUT

51.00
Road 3 EX00-CCTV-GN-XX0001 -001005 EXTERNAL NETWORK GENERAL LAYOUT
50.00

70.00
4 EX00-CCTV-FV-XX0001 -001005 EXTERNAL NETWORK FIELD VIEW LAYOUT
63.30

5 EX00-CCTV-RD-XX0001 -001001 EXTERNAL NETWORK RISER DIAGRAM LAYOUT

FC-21-CAM-031 6 EX00-CCTV-TN-XX0001 -001001 EXTERNAL NETWORK TOPOLOGY LAYOUT

FC-21-CAM-030 EX00-CCTV-ED-XX0001 -001001


FC-21-CAM-029 7 EXTERNAL ELECTRICAL SINGLE LINE DIAGRAM
HH2C-02 N: 26° 29.709' HH2C-01 FC-21-CAM-028
N: 26° 29.719' 9 EX00-CCTV-DT-XX0001 -001001 MANHOLE AND POLE TRENCH TYP. DETAILS
Type 2 E: 049° 49.285' Type 2 8
E: 049° 49.322'
N: 26° 29.725' WAREHOUSE 07 CCTV - CONDUIT LAYOUT
70.80 106.00 E: 049° 49.360'
10 WH07-CCTV-CN-XX0001-001003
N: 26° 29.682' EX-W08-SW02-091 HH-27 FC-11-CAM-035 LOWER LEVEL 0.00 FFL
FC-34
E: 049° 49.222' 11 WH10-CCTV-CN-XX0001-001003
N: 26° 29.683' FC-11-CAM-034 WAREHOUSE 08 CCTV - CONDUIT LAYOUT

Road
E: 049° 49.223' FC- 34-CAM-090
WAREHOUSE 10 CCTV - CONDUIT LAYOUT
HH-19 FC-11
HH-37

38.20
U.T.M.
N: 26° 29.752' N: 26° 29.751' WAREHOUSES GRID
NORTH

E: 049° 49.509' E: 049° 49.507' LOCATION

15°
PROJECT
NORTH
FC-21-CAM-027
42 41 40 39 38 37 36 35 34

MA
KK
WAREHOUSE-07
FC-21-CAM-025

AH
FC-21-CAM-026 L
HH-28
WAREHOUSE NO.7
N: 26° 29.732' K
FFL +0.00 E: 049° 49.391'

WAREHOUSE-08
FC-21
J
I
67.70

26.70

70.00
Road

EX-W08-SW02-092 H
EX-W10-SW01-042 EX-W10-SW01-043
G
WAREHOUSE NO.8
N: 26° 29.700' IT CABINET-W10-01 F
E: 049° 49.399' FOR CONTINUATION REFER DRAWING
N: 26° 29.712' E
E: 049° 49.395' NO.WH10-CCTV-CN-001003 REV-00
HH2C-30 D
HH-29
Type 2
C
FC-10-CAM-033
N: 26° 29.646' B
FC-35 E: 049° 49.233' FC-10-CAM-032
HH-20
FC-35-CAM-100 KEY PLAN
N: 26° 29.647'
FC-10
E: 049° 49.234'
WAREHOUSE-10 N: 26° 29.715'
E: 049° 49.520'
HH-36
N: 26° 29.714'
E: 049° 49.517'
REVISION:

WAREHOUSE NO.10
EX-W08-SW02-093

EX-W08-SW02-094 EX-W08-SW02-095 EX-W08-SW02-096 EX-W07-SW03-097 EX-W07-SW03-098 EX-W07-SW03-099


90.00
00 05/05/2022 ISSUED FOR APPROVAL. -
EX-W10-SW01-045
REV. DATE DESCRIPTION OF REVISION APP.
69.70

EX-W10-SW01-046

70.00
DRAWN BY: DESIGNED BY: REVIEW BY: APPROVED BY: DATE:
EX-W10-SW01-044
AQM AQM SAM/MM AMH 05/05/2022

Road PROJECT

CCTV CAMERA FOR


FC-37-CAM-013 N: 26° 29.652'
FC-37 E: 049° 49.414'
FC-09-CAM-019 DACO WAREHOUSES
WAREHOUSE STORAGE AREA
FC-36 FC-09-CAM-018
HH-21 FC-37-CAM-014
CLIENT:
N: 26° 29.610' N: 26° 29.651'
N: 26° 29.611' E: 049° 49.244' FC-09
E: 049° 49.245'
FC-36-CAM-101
E: 049° 49.413'

HH-31
SAND AREA N: 26° 29.679'
E: 049° 49.532'
HH-35
N: 26° 29.678'
E: 049° 49.529'

CONTRACTOR:
63.00

64.00
65.00

DRAWING TITLE:
FC-01-CAM-003 FC-08-CAM-015
FC-01-CAM-002
FC-02-CAM-005
FC-05-CAM-008 FC-06-CAM-009 FC-07-CAM-011 FC-08-CAM-016 WAREHOUSE EXTERNAL NETWORK
FC-03-CAM-006 FC-04 GENERAL LAYOUT
N: 26° 29.576' FC-01 N: 26° 29.577' FC-05
FC-06-CAM-010 FC-07-CAM-012 FC-08-CAM-017
E: 049° 49.254' E: 049° 49.254' FC-02-CAM-004 FC-02 FC-06 FC-07
FC-04-CAM-007
FC-03 N: 26° 29.593' N: 26° 29.645'
HH-22 N: 26° 29.584' N: 26° 29.583' N: 26° 29.594' N: 26° 29.604' N: 26° 29.603' N: 26° 29.614' N: 26° 29.624' N: 26° 29.635' FC-08
E: 049° 49.334' E: 049° 49.539'

2.00
E: 049° 49.295' E: 049° 49.294' E: 049° 49.334' E: 049° 49.374' E: 049° 49.374' E: 049° 49.425' E: 049° 49.455' E: 049° 49.499'

HH-23 HH-24 HH-25 N: 26° 29.617' HH-32 N: 26° 29.626' HH-33


HH-26 N: 26° 29.646' HH-34
FC-01-CAM-001 E: 049° 49.425' E: 049° 49.455' N: 26° 29.636' PROJECT NUMBER DRAWING NUMBER SHEET REV.
E: 049° 49.539'
E: 049° 49.499' DACP-SS01
69.30 70.40 69.50 85.20 54.20 75.00 71.00 001
SCALE (A1) EX00-CCTV-GN-XX0001 01
N.T.S 005

You might also like