1. COSMO unit
The COSMO unit is a solution where duplex signal transmission were applied and
the connection of the headset uniphone and instruction panel were made with two
conductor line.
2. Intercom assembly.
2.1 Unit mechanical assembly.
The drawing presents span of the openings to the unit assembly and outdoor wall
cover.
• Cables from the power supply unit (AC 11,5 V) tighten to the clamps marked
~11,5V
• Wires of electromagnetic clamp to the terminals ZACZEP.
• Uniphone “hot” (+) end of the clamp UN1 and “cold” (-) end to the unit chassis
ground marked as MASA.
Fig. 1 The span of assembly openings of the unit including outdoor wall cover. The
dimension of the openings: 5 mm
WARNING:
The power supply unit shall be installed in such a way to prevent against water and
humidity. In the event of the power supply unit assembly in a significant distance from
the unit, the cross section of power supply cables shall be considered. For the cable
of the cable dimension 0,5 mm the distance not more than 10 meters is
recommended.
Prior to the assembly and configuration, the uniphone holder (base) shall be opened.
The holder of the SMART intercom unit can be quickly disassembled, two parts of the
cover are connected with one screw installed under the headphone speaker. In order
to disassemble the cover, the screw must be unscrewed, afterward grab the cover
edge of the holder in its upper part and pull. Repeat the operation by catching the
cover edge in its bottom part.
Upon the disassembly of the cover of uniphone holder, the UN and GDN installation
cables from the unit shall be conducted by the cover opening and connect to the
clamps marked as L+ and L-.
3. Two legs clamp – jumper – short circuit with a jumper transforms the uniphone
from no surveillance version into surveillance version, it is especially useful in
the installations in a single-family houses, where the entry surveillance and full
activity of the uniphone upon taking a receiver from the holder, without a need
of its call can be expected,
4. Button of lock opening,
5. Three positions switch of the ring volume:
The default settings are high sensitivity of the microphone – if there is too high sound
level in the external panel the cramp ring shall be disassembled
The multipurpose button is used for the connection of additional devices (light
switches, gate control etc.) It is independent from the intercom system and is regular
closed contact.
The COSMO intercom unit is equipped with the reader of RFID proximity pendants.
The reader is located directly under the backlit window of a business card. In order to
activate the grabble or program RFID pendant it is necessary to close it the window
of a business card to the distance of approx. 10 mm.
Two MASTER pendants can be programmed to the unit and allow to program and
remove additional pendants up to 98 pcs. The total capacity of the memory is 100
pendants.
• Assembly SW3 jumper marked on the unit plate as “MASTER PROG.” The
unit shall confirm programming mode with sound signals,
• Place, to the antennae located between backlight diodes, two RFID pendants
that are supposed to be programmed as MASTER,
• Registering the pendant is confirmed with sound signals,
• To quit the programming mode, it is necessary to remove SW3 jumper, the
unit is operational.
REMARKS:
REMARKS:
- The unit remains in the programming mode by 10 sec. every closing of a key
prolongs the time by next 10 sec.
The default setting is 4 sec. It can be adjusted within 1-15 sec. To set new time, the
following steps shall be done:
REMARKS:
- Activation of programming the opening time always resets the time to “1 sec”
- For example, to set the time “7 sec.” the button “UN1” shall be pressed six
times and wait 10 sec. for automatic quick from programming mode.