You are on page 1of 16
CONTENTS INTRODUCTION ELECTRICAL SPEQIFICATIONS TECHNICAL FEATURES BUSHINGS STANDARD PRODUCT ACCESSORIES TESTING PAINTING. INTRODUCTION United Transformers Electric Company (Utec) located in 2nd Industrial City, Riyadh - KSA. Established in 2001 with the aim to produce Distribution transformers to meet the needs of public utilities in particular and private industrial sector in general, as well as export markets. Utec is a joint venture between Al- Fozan Group and Wilson Transformer Company (WTO), Australia. WTC is one of the largest transformer producer in Australia established in 1933. Utec products range: Distribution transformers, Oil filled (Hermetically Sealed & Conservator type) as per IEC 60076 standard from 25kVA to 3150kVA up to 36KV (HV) & 1,100V (LV). With state of the art technology, expertise, competency, production equipments & facilities, Utec has executed various contracts for Local / Export Markets Since 2001, Utec has supplied thousands of Distribution Transformers in Local / Export Markets to various Utilities and private sectors. Our objective is to achieve customer satisfaction through timely compliance with customer demands & requirements. We strive constantly to exceed our customer expectations for quality, value, delivery and service ELECTRICAL SPECIFICATIONS STANDARDS TEC 60076 and IEC 60354 SEC Specification No: 51 -SDMS, 56-SDMS, 51-TMSS (including latest revisions) ‘CONSTRUCTION Corrugated or rigid tank, hermetically sealed with or without gas cushion, Immersed in mineral cil 1EC60296 - Class ) Natural cooling: ONAN (KNAN can be provided on raquest) WINDING Both HV and LV windings are made of copper (Aluminum on special request) High Voltage winding: Delta connected, Low Voltage winding: Star connected with neutral brought out. Connection Group: Dyn Other configurations like YNd11, Yan1 1 etc can be provided. ‘TEMPERATURE RISE LIMITS Maximum ambient temperature: 55°C (standard 50°C) Temperature rise of top oll: 40 -60 °C (as per customer request) standard 45°C Avg, Temperature rise of windings: 45 - 65°C (as per customer request) standard 50°C ELECTRICAL CHARACTERISTICS Frequency: 50 or 60 Hz High Voltage + Most used values: 138 kV or 33 kV + Also available: duakprimary voltage 13.8~ 11 kV, 11 ~6.6 kV. «Any voltage can be provided as per customer request. (Up to 36 kV class) Low Voltage (at no load): «Most used values: 231 or 400V + We may supply any voltage required by our client Tapping on HV side (by off-load tap changer}: £2.53 +5% (we may also supply any tapping required by client) Short Circuit withstand time = 2 seconds. (5 sec shot on customer request) Impedance voltage: +A per IEC 60076 -5 or as per customer request, FFSERR soyas em Br oeeKs! State of the art design tools and Engineering capabilities enable Utec to fulfil most stringent requirements . aed TECHNICAL FEATURES STANDARDS Transformers are manufactured according to IEC 60076 in general and in particular as per concerned Utility / Client Specifications. ‘CONSTRUCTION Tank construction can be of any type mentioned below. 5 Hermetically Sealed without gas cushion Figs Sealed with gas cushion Magnetic Circuit Conservator type with breather Cooling with corrugated fin Cooling with radiator MAGNETIC CIRCUIT The magnetic circuit (Fig.1) is made ofa high quality cold rolled, grain oriented silicon stee! strips. Each strip i insulated from both sides by Carlte and is cut with an angle 45°. Step lap. and conventional mitered joint stacking is employed to reduce the no-load losses and the exciting current. WINDINGS Both the Low Voltage andl High Voltage windings (Fig.2) are made (of copper. (Aluminum winding can also be provided upon special request). The high Voltage winding is wound directly on the Low Voltage winding, wit insulating paper and cooling duct, between ‘the two windings. Most modem techniques are used to provide adequate short circuit strength, Windings ‘TAP CHANGER Tappings are provided on the HV windings (number and step according to client requirements) with standard values of £2.5% & 45%, The step change from one tapping to another is done by operating an offload tap changer. Padlock for tap changer handle can be provided VOLTAGE SELECTOR For dual primary voltages (eg, 138-11, 11-6 KV, the switching from one primary voltage to the other is dane by a voltage selector Fig.3 OMLTYPE Transformers are supplied filed with mineral ail according to TEC 60296 - Class. In addition Silicon ot Midal il can be provided fon request Tap changer / voltage selector Fs hhandle (lockable ) BUSHINGS High voltage bushings DIN type, made of porcelain (Fig. 1, 2,3) Plug-in type (Fig. 4) BS type (Fig. 5,6) Low voltage bushings : DIN type, made of porcelain (Fig. 7, 8) Epoxy Bus bar type (Fig. 9) Mono block (Fig. 10) 14 vee oS Figs 2 Po Figo Fig6 . Fig = Figio Fateg Fated Fea) | | | | I | I { ‘can be fulfilled on request. 1250 2 tec standard values are provided. Customer spectic requirements 8 8 g 8 g 8 350 : KNAN Can be provided on request JTEC Standard designs for HV 33 KV & LV up to 1.1 KV (50/60 H2) eee eel NUL twa) ical and mechanical design) can be fulfilled. Wat (a) ‘ 105s) 5/50 ‘ 1405100) a5/50 ‘canbe fufled on request. 5 120m) 5/50 F i 6 wr 1051005 45/50 Utec standard values are provided . Customer specific requirements 6 seo 11001855 45/50 6 om 1000 tea 5/50 6 a ee 6 a ae eee 7 200151510) /60 Any specific customer requirement (regarding electrical and mechanical design) can be fulfilled. z & # 2 a g 8 & = g HENNEY 1 2 SE E eet am nee wary i les : ona | a fof l By 50 ge 435 1300 40 1400 45/50 Bi ow ee os PET TS Ci [ee | 33 | A is ii as is [own a ee ee &8 Ss} = i go om 0 co ara 5 rm Bees ‘l —— 0 a 0 ——_ 2% KNAN Can be provided on request bbb MTL da ACCESSORIES STANDARD ACCESSORIES Name plate & connection diagram (Fig.1) Earthing terminals on tank bottom (Fig.2) Gil filing plug Cl drain valve (Fig.3) Lifting lugs (Fig. 8) Bidirectional rollers (Fig.5) Top cil thermometer with a maximum Indicator (Fig.6) (with or without contacts) Pressure relief device (Fig.7) (with or without contacts) Oil level indicator: Vertical float type (Fig.8) Dial type (Fig.9) ‘OPTIONAL. Buchholz relay Silica gel Breather Winding temperature indicator with contacts DGPT2 multi-function protection relay (Fig.10) that detects and signals: (a)Reduction of oil level (b)Presence of gas (Over temperature Ee Rating Plate Fig.2 Earthing terminal Fig.6 ‘Top oil thermometer Gil leval indicator: vertical float type Fig.8 Gileveindicator: IBIS dial type ‘s A. Fig. Oildarin Valve Fi Adjustable roller Fig.7 Pressure relief device Fig.10 DGPT2 multi-funetion protection relay TESTING On each manufactured transformer the following routine tats will be conducted, in accordance to IEC 60076 prot to final inspection and dispatch to customer. ROUTINE TESTING:- ‘Measurement ofthe turns ratio and phase displacement. Measurement of Insulation resistance, ‘Measurement of winding resistance. Separate source voltage withstand test. Induced over voltage withstand test Measurement of no load loss and magnetizing current. ‘Measurement of short circuit impedance and Load loss Dielectric strength test of Insulating ol, Following type tests and special tests can be performed, as per the design/customer request, according to the related IEC standards, Type Tests Temperature Rise Test. (intemal, Lightning Impulse Test (King Saud University — KSA or International Lab) Utec transformers have been subjected to special test performed by KEMA-Netherland and King Saud University-KSA, Special Tests: Sound Level Test. (Internal + External) Short Circuit Withstand Test. (International Laboratories) ST a Painting system Transformers are coated with heavy duty specialized alkyd system having proven track record under gulf atmospheric services. Our standard painting system is applied through flooding process to ensure uniform application including hard to reach area. Also Epoxy poly urethane system can be applied as primer coat of Epoxy zinc phosphate and top coat of aliphatic polyurethane Enamel by air spray gun to cover the need of highly corrosive areas in accordance of BS EN ISO 12944. DESCRIPTION LIST 1+ HVBUSHING LVBUSHING 5 - POSITION OFF - CIRCUIT TAP SELECTOR. PRISMATIC OIL LEVEL INDICATOR DIAL TYPE OIL THERMOMETER WITH 2 CONTACTS PRESSURE RELIEF DEVICE WITH 2 CONTACTS. DRAIN VALVE WITH SEALING PLUG RATING & DIAGRAM PLATE UNIT LIFTING Lucs 10- EARTH LUG WITH M12 BOLT 111-SKID UNDER BASE 12. RADIATORS 13- LOGO PLATE 14- HV CABLE BOX 15- LV CABLE BOX 16-JACKING PADS. 117-THERMOMETER POCKET 18- FILTER VALVE WITH SEALING PLUG. eeyEN EEN DESCRIPTION LIST ce 2-LV bushing 23- Conservator tank 3-5 position off—crcuittap selector 24- Prismatic oillevel indicator gg 4 4. Dial type oil thermometer 25- Double flanged ball valve Le 5 Pressure relief device with sealing 26 Silica gel breather = 6-Drain valve with sealing plug 27- Conservator cl drain valve 7- Rating & diagram plate 28-Conservator filer stackwith rI"plug 4 8-Unitlifting lugs 29: Buch holzelay 9-Earth lug with m12 bolt 1o-Base channel ae a 11-Side cooling, flexible fins 12. End cooling, flexible fins 13-Logo plate 14 LV phase markers 15- HV phase markers 16-Trunking HV & LV removable he wee tl} fe tp Hvcaleboe ea) 19 LV cable support 20- HV cable support 21-LV extension bus ber i io DESCRIPTION LIST 1+ HVBUSHING LVBUSHING 5 - POSITION OFF - CIRCUIT TAP SELECTOR. FILLER STACK WITH LEVEL INDICATOR, DIAL TYPE OL TEMPERATURE THERMOMETER PRESSURE RELIEF DEVICE DRAIN VALVE WITH SEALING PLUG LV CABLE BOX RATING & DIAGRAM PLATE 10-LVCABLE SUPPORT 11- UNITLIFTING LUGS 12. EARTH LUG WITH M10 BOLT (STAINLESS STEEL) 13 LV PHASE MARKERS (HV MARKERS ON LID) £ eeyEN EEN i 14- ANGLE FEET WITH 2 SLOTS 17120 E aw eer 116- ARRESTER BRACKET 17-LOGO PLATE DESCRIPTION LIST 1+ HVBUSHING LVBUSHING 5 - POSITION OFF - CIRCUIT TAPSELECTOR FILLER STACK WITH OIL LEVEL INDICATOR DIAL TYPE OIL THERMOMETER PRESSURE RELIEF DEVICE DRAINVALVE RATING & DIAGRAM PLATE UNIT LIFTING LUGS. 10- EARTH LUG WITH M12 BOLT 111- BASE CHANNEL WITH TWO SLOTS 17 x40, S&S 12. SIDE COOLING, FLEXIBLE FINS. 13- LOGO PLATE 14- END COOLING, FLEXIBLE FINS 15- FLANGE LV BUSHING 16- FLANGE HV BUSHING 17-LV & HV PHASE MARKERS, Utec) prea el | Peen eeeer | ete ee ene te +. eT PO. Box 385, Riyadh 11383 Pee Cy chee ae eo ee Lea CO ey

You might also like