CONTENTS
INTRODUCTION
ELECTRICAL SPEQIFICATIONS
TECHNICAL FEATURES
BUSHINGS
STANDARD PRODUCT
ACCESSORIES
TESTING
PAINTING.INTRODUCTION
United Transformers Electric Company (Utec) located in 2nd Industrial
City, Riyadh - KSA. Established in 2001 with the aim to produce Distribution
transformers to meet the needs of public utilities in particular and private
industrial sector in general, as well as export markets.
Utec is a joint venture between Al- Fozan Group and Wilson Transformer
Company (WTO), Australia. WTC is one of the largest transformer producer in
Australia established in 1933.
Utec products range:
Distribution transformers, Oil filled (Hermetically Sealed & Conservator type) as
per IEC 60076 standard from 25kVA to 3150kVA up to 36KV (HV) & 1,100V (LV).
With state of the art technology, expertise, competency, production equipments
& facilities, Utec has executed various contracts for Local / Export Markets
Since 2001, Utec has supplied thousands of Distribution Transformers in Local /
Export Markets to various Utilities and private sectors.
Our objective is to achieve customer satisfaction through timely compliance
with customer demands & requirements. We strive constantly to exceed our
customer expectations for quality, value, delivery and serviceELECTRICAL SPECIFICATIONS
STANDARDS
TEC 60076 and IEC 60354
SEC Specification No: 51 -SDMS, 56-SDMS, 51-TMSS (including latest revisions)
‘CONSTRUCTION
Corrugated or rigid tank, hermetically sealed with or without gas cushion,
Immersed in mineral cil 1EC60296 - Class )
Natural cooling: ONAN (KNAN can be provided on raquest)
WINDING
Both HV and LV windings are made of copper (Aluminum on special request)
High Voltage winding: Delta connected,
Low Voltage winding: Star connected with neutral brought out.
Connection Group: Dyn
Other configurations like YNd11, Yan1 1 etc can be provided.
‘TEMPERATURE RISE LIMITS
Maximum ambient temperature: 55°C (standard 50°C)
Temperature rise of top oll: 40 -60 °C (as per customer request) standard 45°C
Avg, Temperature rise of windings: 45 - 65°C (as per customer request) standard 50°C
ELECTRICAL CHARACTERISTICS
Frequency: 50 or 60 Hz
High Voltage
+ Most used values: 138 kV or 33 kV
+ Also available: duakprimary voltage 13.8~ 11 kV, 11 ~6.6 kV.
«Any voltage can be provided as per customer request. (Up to 36 kV class)
Low Voltage (at no load):
«Most used values: 231 or 400V
+ We may supply any voltage required by our client
Tapping on HV side (by off-load tap changer}: £2.53 +5% (we may also supply any tapping required by client)
Short Circuit withstand time = 2 seconds. (5 sec shot on customer request)
Impedance voltage:
+A per IEC 60076 -5 or as per customer request,
FFSERRsoyas em Br oeeKs!
State of the art design tools and Engineering capabilities enable Utec to fulfil most
stringent requirements .aed
TECHNICAL FEATURES
STANDARDS
Transformers are manufactured according to IEC 60076
in general and in particular as per concerned Utility / Client
Specifications.
‘CONSTRUCTION
Tank construction can be of any type mentioned below. 5
Hermetically Sealed without gas cushion Figs
Sealed with gas cushion Magnetic Circuit
Conservator type with breather
Cooling with corrugated fin
Cooling with radiator
MAGNETIC CIRCUIT
The magnetic circuit (Fig.1) is made ofa high quality cold
rolled, grain oriented silicon stee! strips. Each strip i insulated
from both sides by Carlte and is cut with an angle 45°. Step lap.
and conventional mitered joint stacking is employed to reduce
the no-load losses and the exciting current.
WINDINGS
Both the Low Voltage andl High Voltage windings (Fig.2) are made
(of copper. (Aluminum winding can also be provided upon special
request). The high Voltage winding is wound directly on the Low
Voltage winding, wit insulating paper and cooling duct, between
‘the two windings. Most modem techniques are used to provide
adequate short circuit strength,
Windings
‘TAP CHANGER
Tappings are provided on the HV windings (number and step according
to client requirements) with standard values of £2.5% & 45%, The step
change from one tapping to another is done by operating an offload tap
changer. Padlock for tap changer handle can be provided
VOLTAGE SELECTOR
For dual primary voltages (eg, 138-11, 11-6 KV, the switching
from one primary voltage to the other is dane by a voltage selector
Fig.3
OMLTYPE
Transformers are supplied filed with mineral ail according to
TEC 60296 - Class. In addition Silicon ot Midal il can be provided
fon request
Tap changer / voltage selector
Fs hhandle (lockable )BUSHINGS
High voltage bushings
DIN type, made of porcelain (Fig. 1, 2,3)
Plug-in type (Fig. 4)
BS type (Fig. 5,6)
Low voltage bushings :
DIN type, made of porcelain (Fig. 7, 8)
Epoxy Bus bar type (Fig. 9)
Mono block (Fig. 10)
14
vee
oS Figs
2
Po
Figo
Fig6
.
Fig
=
FigioFateg
Fated Fea)
| | | | I | I {
‘can be fulfilled on request.
1250
2
tec standard values are provided. Customer spectic requirements
8
8
g
8
g
8
350
: KNAN Can be provided on request
JTEC Standard designs for HV 33 KV & LV up to 1.1 KV (50/60 H2)
eee eel
NUL twa)
ical and mechanical design) can be fulfilled.
Wat (a)
‘ 105s) 5/50
‘ 1405100) a5/50
‘canbe fufled on request.
5 120m) 5/50
F i
6 wr 1051005 45/50
Utec standard values are provided . Customer specific requirements
6 seo 11001855 45/50
6 om 1000 tea 5/50
6 a ee
6 a ae eee
7 200151510) /60Any specific customer requirement (regarding electrical and mechanical design) can be fulfilled.
z
&
#
2
a
g
8
&
=
g
HENNEY
1
2 SE
E eet am nee wary
i les : ona
| a
fof l By
50 ge 435 1300 40 1400 45/50 Bi ow
ee os PET TS Ci
[ee | 33 |
A is ii as is [own
a ee ee
&8 Ss}
= i go om
0 co
ara 5
rm Bees
‘l
——
0
a
0
——_
2% KNAN Can be provided on request
bbbMTL da
ACCESSORIES
STANDARD ACCESSORIES
Name plate & connection diagram (Fig.1)
Earthing terminals on tank bottom (Fig.2)
Gil filing plug
Cl drain valve (Fig.3)
Lifting lugs (Fig. 8)
Bidirectional rollers (Fig.5)
Top cil thermometer with a maximum
Indicator (Fig.6) (with or without contacts)
Pressure relief device (Fig.7)
(with or without contacts)
Oil level indicator:
Vertical float type (Fig.8)
Dial type (Fig.9)
‘OPTIONAL.
Buchholz relay
Silica gel Breather
Winding temperature indicator
with contacts
DGPT2 multi-function protection relay
(Fig.10) that detects and signals:
(a)Reduction of oil level
(b)Presence of gas
(Over temperature
Ee Rating Plate
Fig.2
Earthing terminal
Fig.6
‘Top oil thermometer
Gil leval indicator:
vertical float type
Fig.8
Gileveindicator: IBIS
dial type ‘s
A.
Fig.
Oildarin Valve
Fi
Adjustable roller
Fig.7
Pressure relief device
Fig.10
DGPT2 multi-funetion
protection relayTESTING
On each manufactured transformer the following routine tats will be conducted, in accordance to IEC 60076 prot
to final inspection and dispatch to customer.
ROUTINE TESTING:-
‘Measurement ofthe turns ratio and phase displacement.
Measurement of Insulation resistance,
‘Measurement of winding resistance.
Separate source voltage withstand test.
Induced over voltage withstand test
Measurement of no load loss and magnetizing current.
‘Measurement of short circuit impedance and Load loss
Dielectric strength test of Insulating ol,
Following type tests and special tests can be performed, as per the design/customer request, according to the
related IEC standards,
Type Tests
Temperature Rise Test. (intemal,
Lightning Impulse Test (King Saud University — KSA or International Lab)
Utec transformers have been subjected to special test performed by KEMA-Netherland and King
Saud University-KSA,
Special Tests:
Sound Level Test. (Internal + External)
Short Circuit Withstand Test. (International Laboratories)ST a
Painting system
Transformers are coated with heavy duty specialized alkyd system having proven track record
under gulf atmospheric services. Our standard painting system is applied through flooding
process to ensure uniform application including hard to reach area.
Also Epoxy poly urethane system can be applied as primer coat of Epoxy zinc phosphate and top
coat of aliphatic polyurethane Enamel by air spray gun to cover the need of highly corrosive areas
in accordance of BS EN ISO 12944.DESCRIPTION LIST
1+ HVBUSHING
LVBUSHING
5 - POSITION OFF - CIRCUIT TAP SELECTOR.
PRISMATIC OIL LEVEL INDICATOR
DIAL TYPE OIL THERMOMETER WITH 2 CONTACTS
PRESSURE RELIEF DEVICE WITH 2 CONTACTS.
DRAIN VALVE WITH SEALING PLUG
RATING & DIAGRAM PLATE
UNIT LIFTING Lucs
10- EARTH LUG WITH M12 BOLT
111-SKID UNDER BASE
12. RADIATORS
13- LOGO PLATE
14- HV CABLE BOX
15- LV CABLE BOX
16-JACKING PADS.
117-THERMOMETER POCKET
18- FILTER VALVE WITH SEALING PLUG.
eeyEN EEN
DESCRIPTION LIST ce
2-LV bushing 23- Conservator tank
3-5 position off—crcuittap selector 24- Prismatic oillevel indicator gg 4
4. Dial type oil thermometer 25- Double flanged ball valve Le
5 Pressure relief device with sealing 26 Silica gel breather =
6-Drain valve with sealing plug 27- Conservator cl drain valve
7- Rating & diagram plate 28-Conservator filer stackwith rI"plug 4
8-Unitlifting lugs 29: Buch holzelay
9-Earth lug with m12 bolt
1o-Base channel ae a
11-Side cooling, flexible fins
12. End cooling, flexible fins
13-Logo plate
14 LV phase markers
15- HV phase markers
16-Trunking HV & LV removable he
wee tl} fe
tp Hvcaleboe ea)
19 LV cable support
20- HV cable support
21-LV extension bus ber
i ioDESCRIPTION LIST
1+ HVBUSHING
LVBUSHING
5 - POSITION OFF - CIRCUIT TAP SELECTOR.
FILLER STACK WITH LEVEL INDICATOR,
DIAL TYPE OL TEMPERATURE THERMOMETER
PRESSURE RELIEF DEVICE
DRAIN VALVE WITH SEALING PLUG
LV CABLE BOX
RATING & DIAGRAM PLATE
10-LVCABLE SUPPORT
11- UNITLIFTING LUGS
12. EARTH LUG WITH M10 BOLT (STAINLESS STEEL)
13 LV PHASE MARKERS (HV MARKERS ON LID) £
eeyEN EEN
i
14- ANGLE FEET WITH 2 SLOTS 17120 E
aw
eer
116- ARRESTER BRACKET
17-LOGO PLATE
DESCRIPTION LIST
1+ HVBUSHING
LVBUSHING
5 - POSITION OFF - CIRCUIT TAPSELECTOR
FILLER STACK WITH OIL LEVEL INDICATOR
DIAL TYPE OIL THERMOMETER
PRESSURE RELIEF DEVICE
DRAINVALVE
RATING & DIAGRAM PLATE
UNIT LIFTING LUGS.
10- EARTH LUG WITH M12 BOLT
111- BASE CHANNEL WITH TWO SLOTS 17 x40, S&S
12. SIDE COOLING, FLEXIBLE FINS.
13- LOGO PLATE
14- END COOLING, FLEXIBLE FINS
15- FLANGE LV BUSHING
16- FLANGE HV BUSHING
17-LV & HV PHASE MARKERS,Utec)
prea el | Peen eeeer | ete
ee ene te
+.
eT
PO. Box 385, Riyadh 11383
Pee Cy
chee ae eo
ee Lea
CO ey