You are on page 1of 3

Bless Power

BP-G110P
Bless Power diesel generator sets can help you solve all your power needs. Bless Power can help protect your business
from the serious consequences of losing power, as almost all businesses are dependent on electrical power. Bless Power
global power system, can provide reliable emergency standby and prime power systems for homes and businesses that can
minimise downtime.

Standard Future
Perkins Engine Model 1104C-44TAG2
STAMFORD Alternator UCI 274C
DSE Controller 6020
MCCB - Breaker (Option)
Base Fuel Tank
Emergency stop button, alarm and panel light
12 VDC Maintenance free battery
Float battery charge
Battery isolator switch
Radiator with engine driven and fan mounted
Anti Vibration mounting
Silencer with flexible connections
Test report, Operation and maintenance book
*Designed to comply with ISO 8528 Standard tool for maintenance

General Main Data


Genset Model BP-G110P
Standby Power 110 KVA/ 88 KW
Prime Power 100 KVA/ 80 KW
Frequency 50 HZ
Speed 1500 RPM
Voltage 230 / 400 V
Power Factor 0.8
Phase Three Phase, Four Wire
Fuel Consumption (L/H) Prime Standby
Apprx. ±5% 100% 26.9 29.7
75% 20.2
50% 14.1
Opentype Silentype
Dimensions Apprx.(LxWxH) mm
1950*760*1250 2420*960*1350
Weight Approx.(Kg) 1050 1750
Base Fuel Tank (L) 150 150
PRIME POWER : The rating is available for an unlimited of annual operating hours in variable load applications, in
accordance with ISO8528-1.A 10% overload is available for a period of 1 hour within 12-hour period of operation, in
accordance with ISO 3046-1. STANDBY POWER : The rating is applicable for supplying emergency power in variable load
applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed.
All qualified generator sets are subjected to a comprehensive performance test until 100% load or base on rating conditions
and also verify that all control systems, alarm and shut-down protection
Engine Data
Perkins designs and manufactures all major components of our generator sets – engines, alternators and control systems.
This integrated approach means each element is matched to work in harmony from the start.
Engine Model 1104C - 44TAG2
Brand Perkins
Engine Speed 1500 Rpm
Standby 103 KWm
Engine Power
Prime 93.6 KWm
Bore x Stroke (mm) 105*127
Displacement (L) 4.4
Cylinder Arrangement In line type - 4 Cylinders
Stroke 4 - Stroke
Compression Ratio 18.2 : 1
Aspiration Turbocharger - Air to Air Charge air cooled
Cooling Method Water Cooled
Governor Type Electric Governor
Lub Oil Capacity - Total (L) 8
Colant Capacity - Total (L) 12
Fuel Consumption 100% - (L/H) PRP 26.9
Motor Starter 12-VDC
Alternator Charge 12-VDC

Generator Data
STAMFOR industrial generators meet therequirements of BS EN 60034 and the relevant sectionof other international
standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359.Other standards and certifications
can be considered onrequest.

Alternator Model UCI 274C


Brand STAMFORD
Output Power 100 KVA
Voltage Control AVR
Voltage 230 / 400 V
Phase 3
Power Factor 0.8
Insulation Class / Temp Rise H/H
Protection Level IP23
Number of Pole 4
Bearing Method Single Bearing
Coupling Model Direct Couple
Connection Series Star
Bless Power serves for the customers with improved products continually. Therefore specification and some materials will be changed
without notice.
Control Panel
Deepsea 6020 is an auto mains failure controller for single generator, it can monitor and protect the generator working
all the time. it has a LCD display which clearly shows the status of the engine. this controller include seven inputs and six
outputs. This controller can also be programmed using the frong panel or by using DSE configuration Suite PC software.

PARAMETERS :
This controller can provide Generator frequency, Under/over speed, Generator volts, Generator current, Engine oil
pressure, Engine coolant temperature, Flexible fuel level, Hours run counter, Battery volts, Fail to start/stop, Emergency
Stop. Failed to reach loading voltage/frequency, Charge fail, Loss of magnetic pick-up signal, Low DC voltage, CAN
diagnostics and CAN fail/error, Mains volts 3 phase, Mains frequency, AMF indications

PROTECTIONS : FEATURE :
Low Oil Pressure Automatic start stop load transfer and alarming of generator

High Water Temperature CAN and magnetic pick up versions


High Voltage and Under Voltage PC and front panel configurable
Overspeed 4 digital inputs and 3 analogue inputs
6 output ( 4 configurable on magnetic pick up, 6 configurable
Voltage Adjuster and Frequency Adjuster
on CANBUS version
Emergency Stop 3 phase generator and mains voltage monitoring
Fail to Start Remote start on or off load
Advance metering capability
Test button
Protected solid stage output
Transfer beetwen mains and generator power
User friendly set up and button layout
Multiple engine parameters monitored simultaneously
Module can be configurated to suit individual applications
IP 65 rating offers advanced resistance to water ingress when
gasket is fitted

Other Informations
CANOPY ADVANTAGE :
All metal canopy part are painted by powder
Thermally insulated engine exhaust system
coating
Doors in every side with steel palte material tch.2
Easy for moving and lifting
mm
The canopy design using MODULARS principies -
Easy for maintenance and operating
CKD
Bless Power silent generator is designed by professional
Emergency stop push button is installed outside of acoustic engineers based on years of experience.
the canopy The noise Level of the generator less than 80-85dB(A) at 1m, or
70-75dB(A) at 7m

CANDI INDUSTRIAL ESTATE 29-A1-No.26,


Semarang - CENTRAL JAVA, INDONESIA
Phone . +62 24 7627091, Fax . +62 24 76469143
Website. www.blesspowersystem.com

BLESS POWER reserves the right to modify the characteristics of its product at any time in order to incorporate the latest technological
developments.The information contained in this document may therefore be changed without notice.

You might also like