You are on page 1of 4

TECHNOLOGY IS

NOW FOR EVERYONE


THE NEW
WEB BASED
D-500
The D-500 is an
advanced genset
controller capable of
every possible
communication and
functionality.

COMMUNICATIONS FUNCTIONALITIES
Ethernet port (10/100Mb) AMF unit with uninterrupted transfer
GSM-GPRS ATS unit with uninterrupted transfer
Internal GPRS modem (optional) Remote start controller
Embedded web server Manual start controller
Web monitoring Engine controller
Web programming Remote display & control unit
Central Monitoring through internet 400 Hz enabled
SMS message sending Waveform display of V & I
E-mail sending Harmonic analysisof V & I
Free PC software: Rainbow Plus CTs at genset or load side
Free Central Monitoring (100 genset) Long term recording on flash card
Modbus RTU through RS-485
Modbus TCP/IP TOPOLOGIES
SNMP
USB Host (optional) 2 phases 3 wires, L1-L2
USB Device 2 phases 3 wires, L1-L3
RS-485 port, adjustable baud rate 3 phases 3 wires, 2 CTs
RS-232 (optional) 3 phases 3 wires, 2 CTs (L1-L2)
Micro SD card slot (optional) 3 phases 3 wires, 2 CTs (L1-L3)
J1939-CANBUS 3 phases 4 wires, star
3 phases 4 wires, delta
1 phase 2 wires
COMMUNICATIONS

USB
ho

TECHNICAL SPECIFICATIONS
Alternator voltage: 0 to 300 V-AC (Ph-N) Operating temperature: -20°C to 70°C (-4 to +158 °F)
Alternator frequency: 0-600 Hz. Storage temperature: -40°C to 80°C (-40 to +176°F)
Mains voltage: 0 to 300 V-AC (Ph-N) Maximum humidity: 95% non-condensing.
Mains frequency: 0-600 Hz. IP Protection: IP54 from front panel, IP30 from the
Topology: 1-2-3 phases, with or without neutral rear.
DC Supply Range: 8.0 to 36.0 V-DC. Dimensions: 200 x 148 x 46mm (WxHxD)
V-A-cos Accuracy: 0.5% + 1 digit Panel Cut-out Dimensions: 176 x 121 mm minimum.
kW-kVA-kVAr Accuracy: 1.0% + 1 digit Weight: 450 g (approx.)
Current consumption: 500 mA-DC max. Case Material: High Temperature, non-flammable
Current Inputs: from current transformers. ../5A. ABS/PC
Digital inputs: input voltage 0 to 36 V-DC. Mounting: Front panel mounted with rear retaining
Analog input range: 0-5000 ohms. plastic brackets.
Mains and genset contactor outputs: 16Amps@250V EU Directives Conformity
DC Outputs: Protected mosfet semiconductor outputs, -2006/95/EC (low voltage)
rated 1Amp@28V-DC -2004/108/EC (electro-magnetic compatibility)
Cranking dropouts: survives 0V for 100ms. Norms of reference:
Magnetic pickup voltage: 0.5 to 50Vpk. EN 61010 (safety requirements)
Magnetic pickup frequency: 0 to 20000 Hz. EN 61326 (EMC requirements)
Charge Alternator Excitation: 2W. UL Compatibility:
Ethernet Port: 10/100 Mbits UL 508 - Industrial Control Equipment
USB Device: USB 2.0 Full speed CSA Compatibility:
USB Host: USB 2.0 Full speed CAN/CSA C22.2 No. 14-2005 – Industrial Control
RS-485 Port: selectable baud rate Equipment
RS-232 Port: selectable baud rate
WEB SERVER

Digital Monitoring Event Log Display Web Programming