Sp AUTOMATIC HEMATOLOGY ANALYZER esifikasi : Throughput of 60 samples per hour 20 parameter + 3 histograms Automatic clog clearing + Whole blood 14 ul and Pre-dilueted 20 UL + Memory of 35,000 sample results with + Reagent expired alarm * QC with L-J graph histogram HOSPITAL LABORATORY EQUIPMENT CHEMICAL MEDICAL SUPPLIES : Komplek Ruke Paradiso Residemce No.1 Jatimakmur, Pondok Gede - Bekasi NOTELPON — : 021-84977266 WA + 081513727371-08158807103 EMAIL : saranamedika99@gmailcom musrean counnr 5 Part Differential Hematology Analyzer ACCURACY GUARANTEED AT ITS BEST ‘Accutate and reliable Mispa Count X is a compact hematology system with 20 parameters and 3 Histograms. The Mispa Count X has a smart technology which requires only micro-sampling of 14 uL.ot ‘whole blood and 20 jLofprediluted torunany mode of blood sample. PRECISION REDEFINED High-Tech Lager cut Ruby aperture of 70 micron for RBC / PLT and 100 micron for WBC, the facets on brilliant cut gems known for its strength and high precision is designed to offer better impedance and interferencefree quality result. DESIGNED FOR SPACE Guaranteed to stand out with its classic good looks, Mispa Count X is designed to it in any lab as it offer small foot print and most ergonomic and minimalist design. Its front has an especially unique, particularly powerful design with curved sampling area which offers hazard free sampling process and provide more impressive look, Special highlight: The radial designed probe with broad aspiration switch ‘makessamplingeasy atbest of convenience. AFFORDABLE RELIABLE CH@ICE CH@ICE musrma coun. ' Part Differential Hematology Analyzer v J a Sed | Highly thermo-chemical resistant, corrosion resistant, Maintenance free and very low coefficients of friction make syringe highly durable. No stick- slip effect to ensure better sample aspiration and dispensing of reagents. Ruby apertures ensure high durability of the apertures and quality of the result as wel. Parameter Low Target High Target (unin) Values Value (95% Confidence Limit) WBC COL) >0<4 90 <1 REC (IOV) —>0<2 6.20 <1 HB (g/dl) >0<10 722.0 <1 PLT(LOYpL) —->0<100 900 PERFORMANCE AHEAD OF EXPECTATIONS TMS IPA SEED » porameters At Glance ‘5 Part Differential Hematology Analyzer Parameters:- WBC, LYM, LYM%, MID#, MID%, GRAN#, GRAN? RDW-CV, RDW-SD, MCH, MCHC, PLT, MPV, PCT, PDW, P-LCR , RBC, HGB, HCT, MCV, Mitograme-W8C REC PLT Henecencet! | eal | Rey, toms | Sars 8 ‘WBC (10'/pL) >6.0 < 2.5% MCV (fL) 285 «1.5% fr ns <58_|| _acroo seed aa ene +s <1oy | eowove —>120 <6 GRA% >50 <5% RDWSD. 225 <4% mecioniy, san |

You might also like