You are on page 1of 1

DO NOT SCALE FROM THIS DRAWING.

ALL DIMENSIONS ARE


TO BE CHECKED ON SITE. THIS DRAWING IS TO BE READ IN
CONJUNCTION WITH ALL CONSULTANTS INFORMATION.

TAYLORHARE ARCHITECTS IS A LIMITED LIABILITY


PARTNERSHIP REGISTERED IN ENGLAND AND WALES: NO.
0C397240.

13.90m 13.92m
13.84m 13.84m

Clay Tile
Clay Tile

12.33m
12.16m
12.09m
11.88m 11.82m
W.07
Repair and
redecorate existing
sash window. If W.08 W.09
repair not feasible
then allow for
replacement Repair and Repair and
casement redecorate existing redecorate existing
sash window. If sash window. If
repair not feasible repair not feasible
10.66m then allow for then allow for 10.66m
replacement replacement
casement casement
line of existing wall unknown

*existing brickwork to
be repaired like for
like where necessary

9.60m
W.04
9.26m Repair and
redecorate existing
sash window. If
repair not feasible 8.96m
then allow for

1000
replacement 1350
line of existing wall unknown

casement

W.06 W.05
44 x 19mm cedar/larch cladding
with 16mm gap. Coated with
765 44 x 19mm cedar/larch cladding envirograf intumescent paint
with 16mm gap. Coated with (setting out to be agreed on site)
envirograf intumescent paint
Painted Brick (setting out to be agreed on site)

7.58m - existing parapet wall level


7.46m
Wienerberger Wienerberger
Olde Wells Rustica Olde Wells Rustica
(laid as Soldier Course - mid level (laid as Soldier Course - mid level
recessed 25mm)
6.97m recessed 25mm) The Standard Patent Glazing Company (SPG)'Rafter Line' double glazed Rooflight
W.01 (25 degrees pitch)
Repair and DG.01
redecorate existing Retain existing
sash window. If door w/ fanlight
repair not feasible and carefully
then allow for inserted into new
replacement location
casement Proposed Garden Wall
client to confirm
Wienerberger
1650

decoration (if
required) Olde Wells Rustica

3075
2325

2325
W.03 Proposed Boundary Wall
Wienerberger

2250
Olde Wells Rustica
900
DG.04 DG.04
675

Wienerberger
Olde Wells Rustica
4.74m 4.70m 4.69m 4.63m - proposed FFL 4.63m - proposed FFL

Retain existing
external steps.
4.55m - proposed terrace level 4.55m - proposed terrace level
Painted TBC
Brick planter to
take RWP 4.35m - existing garden level 4.35m - existing garden level
discharge

REV DATE DESCRIPTION


A 01.11.2022 Building Control Comments (31.10.22)

A 25.01.22 Building Control Comments (31.10.22)

Existing Existing Existing


South East Elevation (front) North West Elevation (rear) North West Elevation (rear)

TaylorHare
Architects
01227 668 073 The Cowshed
hello@taylorhare.com Overland Lane
taylorhare.com Ash, CT3 2LE

PROJECT:

1822 GRFI
Proposed Renovation and Extension at
14 St George's Road, Deal
DRAWING TITLE:

Proposed
Sections
SCALE: DRAWN BY:

1:50 @ A1 03
DATE DRAWN: CHECKED BY:

SEPTEMBER 2020
STATUS:

TENDER
DRAWING NUMBER: REVISION:

0 0.5 1 2 3M 1822_210 B