You are on page 1of 2

96M11797 • Check that the AC input rated voltage of this unit is equal to

the voltage of the AC power supply.


• Do not connect the AC power supply to the DC output
NOTICE terminals.
• Do not disturb the convection of air near the vent of the
casing.
Compact Switching Power Supply
MS-E07/F07 Precautions on Regulations and Standards
 CE Marking
Keyence Corporation has confirmed that this product complies with the essential
Instruction Manual requirements of the applicable EC Directive, based on the following specifications.
Be sure to consider the following specifications when using this product in the
Member State of European Union.
 EMC Directive (2004/108/EC)
• Applicable Standard EMI: EN55011, Group1 Class A
EMS: EN61000-6-2
Remarks:
These specifications do not give any guarantee that the end-product with this
product incorporated complies with the essential requirements of EMC Directive.
The manufacturer of the end-product is solely responsible for the compliance on the
end-product itself according to EMC Directive.
 Low-Voltage Directive (2006/95/EC)
• Applicable Standard EN60950-1
• Overvoltage category II
• Use this product under pollution degree 2
• This product is an open type device. Therefore, it must be installed in an
enclosure with IP54 or higher. (Industrial control panel)
Intorduction • Use this product under conditions in which the load factor is 70% or less
Read this manual before using the product in order to achieve maximum • Be sure to install the wiring to the AC input terminals and FG terminal inside the
performance. industrial control panel.
Keep this manual in a safe place after reading it so that it can be used at any time.  UL Certificate
This product is an UL/C-UL Recognied product.
 Symbols • UL File No. E197232
The following symbols alert you to important messages. Be sure to read these • Category QQGQ2/QQGQ8
messages carefully. Be sure to consider the following specifications when using this product as an UL/
It indicates a hazardous situation which, if not avoided, will result C-UL Recognized product.
DANGER in death or serious injury. • Overvoltage category II
It indicates a hazardous situation which, if not avoided, could • Use this product under pollution degree 2
WARNING result in death or serious injury. • This product is an open type device. Therefore, it must be installed in an
enclosure with IP54 or higher. (Industrial control panel).
It indicates a hazardous situation which, if not avoided, could
CAUTION result in minor or moderate injury. • Be sure to install the wiring to the AC input terminals and FG terminal inside the
industrial control panel.
It indicates a situation which, if not avoided, could result in
NOTICE product damage as well as property damage.

Important It indicates cautions and limitations that must be followed during Part Names
operation.

−V
Point It indicates additional information on proper operation.
DC output terminals
Reference It indicates tips for better understanding or useful information. Connect the load cable
+V
MS-E07: 5 VDC
MS-F07: 12 VDC
Output indicator
Safety Information for MS Series Illuminates when DC output (+V,
-V) is ON.
• Do not use this product for the purpose to protect a human Output voltage adjustment trimmer
body or a part of human body. Adjusts output voltage within the
• This product is not intended for use as explosion-proof range of ±5%.
product. Do not use this product in a hazardous location and/
or potentially explosive atmosphere. FG terminal
• Do not perform any electrical wiring while electric current is Connect the grounding cable.
applied. Failure to follow this may result in an electric shock or
fire.
• Be sure to connect the grounding cable. Failure to follow this
may result in an electric shock or fire. AC input terminals
WARNING
• Do not touch this unit within 1 minute after AC input is turned Connect the input cable (100 to
off. Failure to follow this may result in an electric shock. 240 VAC)
• Do not modify or repair this unit. Failure to follow this may Note: This terminal is N.C. (not connected) unless otherwise specified.
result in an electric shock, accident, or product failure. Do not use this terminal.
• Do not touch any terminal of this unit while electric current is
applied.
Use the unit with the terminal cover installed to avoid an Installation Method
electric shock.
 Surrounding area
• When this unit is used in a system that may cause a serious For heat dissipation, leave the following space between this unit and
accident or damage if the unit fails, be sure to install a safety control console walls or other devices.
device. Every direction: 10 mm min. 10 mm or more
• Pay attention to prevent foreign matter such as metal particles,
dust, paper, or wood chips from entering the inside of this
unit. Failure to follow this may result in a fire or product failure. 10 mm or
CAUTION more 10 mm
• Do not touch any metallic part while electric current is applied or more
or immediately after input is shut off. Failure to follow this may MS-E/F
result in a burn due to a high temperature.
• If a failure or abnormality occurs while this unit is in use,
immediately shut off AC input and stop operation of this unit.
Failure to follow this may result in a fire or accident.
10 mm or more

1 MS-E07/F07-IM_E
 Installation orientation
Standard and upward installationis available as shown below. Output Derating Characteristic

100
* The characteristic data shown above are
90
80
obtained when this unit is installed as

Load factor (%)


70 described in this Manual.
60 * The maximum rated load is limited to the out-
50
put derating characteristic. We recommend
40
that you use this unit under conditions in
Installation Conditions 30
20 which the average load factor is 70% or less.
10
0
 Installation environment -10 0 10 20 30 40 50 60 70
(14) (32) (50) (68) (86) (104) (122) (140) (158)
• Install this unit indoors. Ambient temperature (°C (F°))
• Do not install this unit in locations exposed to direct sunlight.
• Do not install this unit in locations in which there is corrosive gas or flammable gas.


Do not install this unit in locations exposed to a lot of dust, soot, or steam.
Do not install this unit in locations in which water, oil, or chemicals may splash
Dimensions
onto the unit.
7
• When installing this unit in a location subject to vibration or impact, consider the 8.6 8.6

vibration proof mounting. 9.5

 When installing this unit in a control console 80 35.4 72

• The ambient temperature for this unit should not exceed the upper temperature
limit (refer to the derating characteristic). When the upper temperature limit may 22 70.7
Mounting hole
2 x ø5
be exceeded, install a forced fan or cooler so that the ambient temperature is 30 75

below the upper temperature limit.


• Leave a sufficient ventilation space around this unit for heat dissipation.
• Do not install this unit just above a device with high heat generation (heater,
transformer, large-capacity resistor, etc.). Warranties and Disclaimers
Wiring (1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
 Selecting cables and crimp terminals models or samples were shown to Buyer, such models or samples were used
Terminals Crimp terminals merely to illustrate the general type and quality of the Products and not to
represent that the Products would necessarily conform to said models or
Model Screw size Tightening torque 7 mm max. samples. Any Products found to be defective must be shipped to KEYENCE
MS-E/F M3 1.2N·m max. with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will
7 mm max. refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting
Cables from any action of Buyer, including but not limited to improper installation,
Select cables with a wire diameter suited to the output rated current. improper interfacing, improper repair, unauthorized modification,
misapplication and mishandling, such as exposure to excessive current, heat,
Specifications coldness, moisture, vibration or outdoors air. Components which wear are not
warranted.
Model MS-E07 MS-F07 (2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
Input voltage*1 85 to 264 VAC (50/60 Hz)
fitness of the Products for Buyer’s intended use. KEYENCE will not be
conditions

Efficiency 70 to 75% (typical)


responsible for any damages that may result from the use of the Products.
Input

Input current (100/200 VAC) 0.28/0.16 A max.


Leakage current (100/200 VAC) 0.5/1 mA max. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
Rush current (100/200 VAC) 18/36 A max. (at 25°C (77°F) cold start)
fail-safe systems, unless their written specifications state otherwise. Should any
Rated output voltage 5 VDC 12 VDC
Products/Samples be used in such a manner or misused in any way, KEYENCE
conditions

Rated output current 1.5 A 0.65 A


Output

assumes no responsibility, and additionally Buyer will indemnify KEYENCE and


Ripple/noise voltage 2% (p-p) max. hold KEYENCE harmless from any liability or damage whatsoever arising out of
Starting time*2 400 ms max. any misuse of the Products/Samples.
Output holding time 20 ms min. (100 to 240 VAC) (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
Overcurrent 1.9 A min. 0.79 A min. PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
tection
Pro-

EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,


Overvoltage *3 Provided WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF
-10 to +60°C (14 to 140°F), No freezing
Ambient temperature PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
(Refer to the derating characteristic.)
IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE
Relative humidity 25 to 85%, No condensation
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
Ambient temperature for INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
-20 to +70°C (-4 to 158°F), No freezing
storage
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM
3.0 kVAC, 50/60 Hz, 1 minute LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS
Environmental resistance

(between input and output terminals),


OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE
2.0 kVAC, 50/60 Hz, 1 minute
Dielectric strength COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR
(between input and FG terminals)
500 VDC, 1 minute. TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN
(between output and FG terminals) CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS,
300 m/s2 in X, Y, and Z directions, 2 times EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED
Shock immunity OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER
respectively
10 to 55 Hz, 1.5 mm (max.) double amplitude CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing
in X, Y, and Z directions, warranty disclaimers or damage limitations may not apply.
Vibration
2 hours respectively
(1 G max. when installed to DIN rail) BUYER'S TRANSFER OBLIGATIONS:
100 MΩ min. at 500 VDC If the Products/Samples purchased by Buyer are to be resold or delivered to a
(between input and output terminals) third party, Buyer must provide such third party with a copy of this document, all
Insulation resistance
(between input and FG terminals) specifications, manuals, catalogs, leaflets and written information provided to
(between output and FG terminals) Buyer pertaining to the Products/Samples.
UL: UL60950-1
Applicable
Standard

Safety Standard c-UL: CSA C22.2 No.60950-1 E 1110-2


EN: EN60950-1
FCC Part 15B Class A,
EMC Standard
EN55011 Class A, EN61000-6-2
Weight Approx. 140 g
*1 For conforming to safety standards show above, rated input voltage is 100 to 240 VAC (50/60
Hz).
*2 Specified with the rated input voltage (100 or 200 VAC) and 100% load applied.
*3 The MS-F Series is a Zener-diode clamp type. The unit does not restart after the protection
circuit is activated.

Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.


11797E 1081-1 96M11797 Printed in Japan

MS-E07/F07-IM_E 2