You are on page 1of 7

END-TO-END

TEST AUTOMATION

Demo Report
Failure Analysis
SEGRON Business Solutions

© SEGRON, s.r.o. all rights reserved


SEGRON Automatic Testing Framework (ATF)
Demo Report - Overview

Test Run Duration


including automatic
re-execution One Case FAILED out
of 11 Cases

© SEGRON, s.r.o. Slide 2


SEGRON Automatic Testing Framework (ATF)
Demo Report - Failed Case Analysis LTE Attach failed also during
re-execution.
The Message gives already a
hint to the error cause.

© SEGRON, s.r.o. Slide 3


SEGRON Automatic Testing Framework (ATF)
Demo Report - Failed Case Error Message LTE Attach failed also during
re-execution.
The Message gives already a
hint to the error cause.

© SEGRON, s.r.o. Slide 4


SEGRON Automatic Testing Framework (ATF)
Demo Report - Failed Case Error Cause ERROR CAUSE:
We made the test fail by intention
as we used an Austrian SIM in SK
Telekom network and initiated an
LTE Attach, knowing that there is
currently no 4G roaming enabled.

The Error Cause displayed by the


ATF show’s this problem.