Signal conditioner
FEATURES
py
o
DESCRIPTION
C
The IPC 704 signal conditioner converts the charge- grator to give a velocity output. Furthermore, RFI fil-
based signal from a piezoelectric transducer into a ters protect the input and output against radio-
w
current or a voltage signal. This current or voltage sig- frequency interference and other electromagnetic
nal is transmitted to the processing electronics via a influences.
ie
standard 2-wire or 3-wire transmission cable.
A range of installation options are available for the
v
The current modulation technique allows transmis- IPC 704 signal conditioner, including:
sion over a distance of up to 1 km. A GSI galvanic
e
separation unit is required for this configuration. ] A polyester enclosure providing environmental
protection against dust, oil and water jets
R
The electronic circuitry of the IPC 704 signal condi-
tioner is incorporated into a moulded aluminium ] A mounting adaptor allowing the IPC 704 signal
enclosure. The signal conditioner has configurable conditioner to be mounted on a DIN rail
high-pass and low-pass filters and an optional inte-
BLOCK DIAGRAM
U
I/P+ I +24V
COM or or COM
I/P– U O/P
U
symetrical
LP and HP filters
charge amp amplifier or output
Ground integrator stage
p y
SPECIFICATIONS
C o
ENVIRONMENTAL CHARACTERISTICS
Specifications according to iec 68.2 recommendations
w
General
ie
Temperature
• Operation -30°C to +80°C
• Storage -40°C to +85°C
v
Humidity Max. 95% non-condensing
e
Protection class IP 40 according to IEC classification
Vibration 2 g peak between 10 and 500 Hz
R
Shock 15 g peak, 11 ms, half-sine pulse
Explosive atmospheres
Without industrial housing (ordering options A2 and G0/G2)
• EC type examination certificate LCIE 02 ATEX 6085 X II 2 G (Zones 1, 2) EEx ib IIC T6 to T4
• cCSAus certificate cCSAus 1243981 Class I, Div 1, Groups A, B, C, D Ex ia (T6 to T4)
With industrial housing and stuffing glands (ordering option A2 and G1)
Industrial housing
Available in Ex-approved version for use in hazardous locations
• Environment II 2 G (Zones 1, 2)EEx ia IIC T6
• Surface resistivity for Ex version < 109 Ω (DIN 53482)
SPECIFICATIONS (Continued)
Stuffing glands
Available in Ex-approved version for use in hazardous locations
• Environment II 2 G/D (Zones 1, 2) EEx e II
For specific parameters of the mode of protection concerned and special conditions for safe use, please refer tothe “EC type
examination certificate” that is available from Vibro-Meter SA on demand.
y
Matching transducer Any piezoelectric transducer, symmetrical or non-symmetrical, case grounded or
p
insulated
Dynamic range 100 000 pC peak
o
Input sensitivity Accelerometer: 10 to 200 pC/g
Dynamic pressure transducer: 10 to 2000 pC/bar
C
Charge amplifier Symmetrical
RFI filter Symmetrical LC network
Resistance ≥ 50 kΩ (transducer and cable)
w
Capacitance ≤ 10 nF (transducer and cable)
ie
OUTPUT CHARACTERISTICS (ORDERING OPTION D)
v
Voltage 18 to 30 VDC
Current Max. 25 mA
Re
RFI filter Symmetrical LC network
The 3-wire voltage output without galvanic separation unit should only be used with piezoelectric transducers which are insensitive to frame
voltage. Dynamic pressure transducers should always be used with a GSI galvanic separation unit.
SPECIFICATIONS (Continued)
High-pass filter
• Cut-off frequencies (at -3 dB) 0.5, 1, 2, 5 and 10 Hz
• Slope 24 dB/octave (4th order)
When selecting a high-pass filter, be careful to select an appropriae cut-off frequency of the change amplifier (see graphs below).
Low-pass filter
y
• Cut-off frequencies (at -1 dB) 200, 500, 1000, 2000, 5000, 10 000, 20 000 Hz
p
• Slope 12 dB/octave (2nd order)
o
Charge amplifier cut-off frequencies versus transfer unit
C
a) Accelerometer (acceleration output) b) Accelerometer (velocity output)
w
12.7 25.4 50.8 127 254 508 1270 2540
100 100
ie
50 50
Transducer sensitivity (pC/g)
Transducer sensitivity (pC/g)
v
Hz
20 20
Hz
.5
e
<0
.5
<0
Hz
Hz
10
1
10
Hz
R
Hz
2
2
Hz
Hz
3
1 1
1 2 5 10 20 50 100 200 0.5 1 2 5 10 20 50 100
Output sensitivity (mV/g or µA/g) Output sensitivity (mV/mm/s or µA/mm/s)
C) Pressure sensor
Output sensitivity (mV/psi or µA/psi)
250 17.2
Hz
190 13.1
1
Hz
2
Hz
3
25 1.7
10 0.69
0.02 0.05 0.1 0.2 0.5 1 2 5 10 20
SPECIFICATIONS (Continued)
PHYSICAL CHARACTERISTICS
y
• Cover seal Silicone gasket
• Mounting M6 x 30 mm Allan screws
p
• Dimensions Refer to mechanical diagram
o
Input/output stuffing glands (ordering options H and I)
C
• Type See ordering information
• Material Nickel-plated brass with viton seal
w
Signal conditioner with mounting adaptor (ordering option G2)
ie
Universal DIN rail holder type TSH35
DIN rail type EN50022-35 x 7.5 or EN50022-35 x 15
v
MECHANICAL DIAGRAMS
Re
Signal conditioner without industrial housing (ordering option G0)
p y
Signal conditioner with mounting adaptor (ordering option G2)
C o
ie w
e v
R
ORDERING INFORMATION
Ordering number :
244 - 704 - 000 - 042 A B C D E F G H I
ENVIRONMENT (A)
Standard 1
Explosive 2
y
pC/g mV/mm/s 04
μA/in/s
p
pC/g 05
pC/g mV/in/s 06
o
pC/bar μA/mbar 07
pC/bar mV/mbar 08
C
pC/psi μA/psi 09 INPUT SENSITIVITY (C)
pC/psi mV/psi 10 Sensor sensitivity
w
OUTPUT SENSITIVITY (D)
Value per mechanical unit
v ie
High-pass filter HP FILTER (E)
0.5 Hz Value in Hz
e
1 Hz
2 Hz
R
5 Hz Low-pass filter LP FILTER (F)
10 Hz 200 Hz Value in Hz
500 Hz
1000 Hz
2000 Hz INSTALLATION (G)
5000 Hz Without industrial housing 0
10 000 Hz With industrial housing 1
20 000 Hz Mounted on mounting adaptor 2
ACCESSORIES
p y
C o
ie w
e v
Ordering information: ABA 160 industrial housing
R
Type and designation: ABA 160 industrial housing
Ordering number: Refer to the ordering instructions below
Ordering number :
830 - 160 - 000 - 111 A B1 C1
ENVIRONMENT (A)
CABLE FITTING OUTPUT (C)
Standard polyester 1 (1) NO HOLE 00
Explosive polyester 2
M16 x 1.5 with plug 01
Cable gland M12 x 1.5 for transducer cable 03
CABLE FITTING INPUT (B) Ø4 - Ø8 mm
(1) NO HOLE 00 Cable gland M16 x 1.5 for transducer cable 04
M16 x 1.5 with plug 01 Ø6 - Ø11 mm
Cable gland M12 x 1.5 for cable Ø4 - Ø8 mm 03 Adapter M16 x 1.5/PG9 to be used for KS 106 08
Cable gland M16 x 1.5 for cable Ø6 - Ø11 mm 04 (flexible protection tube)
(1): With option B00, only option C00 is available. For special options (ie. B01/03/04 and C00 or C01/03/04/08 and B00), please
contact your nearest Vibro-Meter sales office.
ACCESSORIES (Continued)
y
SELF-TAPPING CROSS
p
RECESS SCREWS.
TYPE: WN1411, KA40x10
MOUNTING TORQUE: 0,4 Nm
C o
x 4 (SUPPLIED)
ie w
e v
R
Ordering information: MA 130 mounting adaptor
ACCESSORIES (Continued)
This aluminium base plate can be used when an old IPC 620 unit is replaced by an IPC 704 signal conditioner. The
housing of the IPC 620 can be recuperated and the IPC 704 mounted on it.
p y
C o
ie w
Ordering information: base plate for IPC 704 signal conditioner
v
Type and designation Base plate for IPC 704 signal conditioner
e
Ordering number 244-620-002S034
R
In this publication, a dot (.) is used as the decimal separator and thousands are separated by spaces. Example : 12 345.678 90. Although care has been
taken to assure the accuracy of the data presented in this publication, we do not assume liability for errors or omissions. We reserve the right to alter any
part of this publication without prior notice.
www.vibro-meter.com