MID 036 - CID 0279 - FMI 04 Aftercooler Temperature short


to ground
SMCS - 1063-038
MID 036 CID 0279 FMI 04

Conditions Which Generate This Code:

The Electronic Control Module (ECM) reads an output voltage that is 0.2 VDC or less for one second.
The ECM has been powered for three seconds. The CID-FMI 262-03 and/or the CID-FMI 262-04 are
not active.

System Response:

The CID-FMI is logged in memory. The ECM no longer optimizes engine operation according to
aftercooler temperature. The ECM flags aftercooler temperature as invalid data. The engine
monitoring system is disabled for aftercooler temperature.

Test Step 1. Perform the following diagnostic procedure: "Engine Sensor Open/Short Test"

Results:

• OK - STOP

• REPAIRED, OK - STOP