GAS DETECTION NO CALIBRATION - Cutting-edge infrared sensor technology From Zone 0 to inert atmospheres - with means it’s immune to sensor poisoning. the MED Approved TRIPLE-C detector NO CHARGING - 3 years of battery life which includes up to you’re always good to go. 90 seconds of alarm each day, so you never need to charge Innovative 3-year battery life and cutting- the detector. edge infrared technology removes the need to calibrate, meaning no NO COSTS - This detector requires no maintenance, unproductive maintenance breaks and servicing or sensor replacement. no expensive sensor replacement. NO OXYGEN - This detector will even work in completely This all-in-one solution guarantees inert (oxygen free) and Zone 0 (flammable) environments. compliance and reduces risk whilst saving time and money - all at the touch NO MAINTENANCE - Unbox and you’re good to go. This of a single button. detector comes with a lifetime warranty.
NO LIMITS - MED Approved with an IP68 rating, it’s safe
from the finest dust and can even be submerged 1.5 metres underwater for 30 minutes.
NO CONFUSION - This detector is customisable, the sensor
and alarm levels can be adjusted and each device can be digitally assigned. Bump test reminders can be configured as per company standards.
READY TO DISCOVER SIMPLICITY?
CALL THE MARTEK TEAM TODAY TRIPLE-C Technical Specifications
SIZE & WEIGHT GASES
120.65 X 69.85 X 31.75mm (4.75”H x 2.75”W x H2S...........................0 - 100 PPM (0.1 increments) 1.25”D) CO............................0 - 500 PPM (1ppm increments) 220.2G (7.675 Oz.) Combustible (LEL)....0 - 100% LEL (0.1% increments) O2.............................0 - 30% vol. (0.1% increments) TEMPERATURE -20o to +50oC (-4o to 122oF) SENSOR TYPE H2S, CO, O2...............Plug-In Electrochemical Cell HUMIDITY Combustible (LEL)....Soldered Infrared (IR) 5% TO 95% RH (non-condensing) CALIBRATION BATTERY LIFE Can Be Calibrated If Customer Standard Operating 1095 Days Continuous (Inc. daily bump testing & up Procedures Require, Dock Required. to 1.5 min of alarm/day) CERTIFICATIONS & APPROVALS ALARMS CAN/CSA C22.2 152 CSA 16.70084100 Visual, Vibrating & Audible (minimum 95 dB) ANS/UL-913 and ANSI/ISA-S12.13 Low, High, STEL, TWA & OL (Over Limit) Intrinsically Safe/Securite Intrinseque LEDS CSA: Class I, Division 1, Group A,B,C, and D 4 Red Alarm Bar LEDs Class I, Zone 0, AEx ia IIC T4 Ga Yellow Back-Light (activated on button press) UL 60079-0, UL60079-11 Red Back-Light (activated on alarm condition) Yellow Maintenance Notification LED IECEx: IECx CSA 16.0038 IEC 60079-0:2011 DISPLAY IEC 60079-11:2011 High Viewing Angle Alphanumeric Liquid Crystal EX ia IIC T4 Ga Display (LCD) ATEX: Sira 16ATEX2288 LOGS CE II G Ex ia IIC T4 Ga 25 Bump Tests EN 60079-02012/A11:2013 25 Events EN 60079-11:2012 25 Calibrations Continuous 1 Second Data Logging (typical capacity MANUFACTURER LOCATION > 2 months) TRIPLE-C is manufactured by Gas Clip Technologies and is assembled In USA. TESTS Full Function Self-Test Upon Activation USER OPTIONS Sensors, Battery & Circuitry Tests Run Continuously Custom User Message, TWA/STEL Intervals, Languages (6), Latching Alarms, Self-Test Lock, IP RATING Bump Test Interval, Low/High Alarm, Maintenance IP68 Notification, TWA Method, Sensor Enable/Disable, SAFE display, Dock Lock, Span Gas Concentration, WARRANTY Calibration Interval, TWA/STEL Alarm, %LEL or % Full 3 Years CH4 by-vol. Subject to adjustments and updates. Martek Marine Ltd standard Terms & Conditions apply E & O E
Martek Marine www.martek-marine.com
Adwick Park, Manvers, info@martek-marine.com Rotherham, South Yorkshire, UK Office: +44 (0)1709 599 222 S63 5AB, UK Singapore Office: +65 6408 3334