You are on page 1of 12
https phosnixcontact.com/pifproducts/2004605 PHCENIX Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Please be informed that the data shown in is POF Document is generated from our Online Catalog. Please find the complete dain tne user's, documentation, Our Ganeral Terms of Lis for Downloads are vais (hitsTohoenixcontact.comidownload) Primary-svitcned power eupoiy unt, QUINT POWER, Pushin connection, DIN rail mounting, input 1-phase, output: 12V0G/2.5 A ‘Your advantages 5 staring of heavy loads with dynamic Boost [5 Preventive function monitring incicates crical operating states before errors occur High emcieney and long service tie, wth low power csipation and low heating [5 Spave savings in te control cabinet, thanks toa narrow, slim ne design © Fastand easy startup, thanks 1 tol free Pusivin connection technology Key Commercial Data = = om (ANA UN) Technical data Dimensions With 25mm Height 108 re Depth Oram Installation distance gave (active, passive) (Omm Orm (Pe, 3505) Installation dlstence right (passive) Simin Si (Po 250%) Tnatallation alten righ (active) T5men/ 18 mam (Pan 250%) Installation aistanca toprboriom (activa, passive) 30 ren 730 TAT Po 55028) Installation distance topfbotiom (passive) SD mam) a0 ma (Pa, 280%) Tnatallation distance topfbotiom (active) 30mm 30 ma Po, 250%) Ambient conditions Dogroo of protection P20 ‘DarIz 2020 Page 1712 ito: proarixcontact. con pifproducs/2004605 Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Technical data ‘Ambient conditions Tnflammablity clase in aos. with UL 94 (housing / terminal blocks) vo ‘Anibient temperature (operation) 250. 710-0 00 C Darang: 25 900) ‘Anibint temperaiur (storegetranspor) 40°C. 85°C Max, porisibie rlative humic (operation) 205 % (at 25°, non condensing) Clmate cass 3G nace. wth EN BO7E Degree of potion Tnstaliaion height 75000 m (> 2000 m,cbserve derating) Input data Trout votage range TOOVAG 200 VAG 1856 “10% TIOV DC ..260V DC 20%. 0% Diclectic evength maximum BWVACOOS Frequency range (t) SOHE . 60HE-10%., HOM Discharge current PE 0.25 mA (204 V AG, 60 He) ‘Curent consumption (0.44 A(100V AO) Da5ACI2OVAG) 0.19 A(@30V AD) DZARADVAC Nominal power consumption 328VA Tomas current yp BAGS) Mains buffering te yp. 54 ms (120 VAG) typ. 54 ms (230 V AG) Tnputse 3.18 A (Gow blow, itera FResammandad breaker fr input provacion GA... 16 A (Ghatactarisic 8, Cor comparable) “Type of protection Transient surge protection Proteciive croul/oamponent varistor Output data Nominal ouput volaoe 12vDC “Sotung range ofthe autput votlage (Ua) T2VDG... 15 V D0 (oonstant capacity) Nominal output carent () BEA ‘StaUG BOOS (reo) 3125 A400) Dynamic Bo08t onan) ASAE 00°C 68) ‘Connection parallel Yes for redundancy and increased capacity ‘Connection in series ves Feeaback voliage resistance =25VDE Pioteclon agains! overvoiage at the oulpat (OVP) = lave Control deviation 0.2% (Stal load change 10 % 90%) 2% (Dynaic load change 10% .. 00%, (10 Ha) 0:1 (change in input volage #10 %) Resigual ripple = 30 Vee (wth nominal values) er1272020 Page 2/12 ito: proarixcontact. con pifproducs/2004605 Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Technical data Output data ‘Ouiput power 30W “Toil response time 500 m= Maximum power dissipation in no-load condition =04W@30VAD) <0SW(2OVAD) Power loss nominal load max, 148000 @5°O) > 780000 (40°0) > 459000 h (60°O) Insulation voltage inpuvoutput RV AC (ype tos) RV AD (routine test) Degree of protection iz Provecion cass Teflammablity class in aos, with UL 94 (hausing /Terminal blocks) vo Connection data, input ‘Conneaton method Pustrin connection ‘Conductor rose section 60d mi D2 ane ‘Conductor ross seaion sold max: 25 mene ‘Conductor ross section flexible min Da mene ‘Conductor crass section flexible max 25 nF ‘Conductar cross section AWG min me ‘Conductar cross section AWG max 2 ‘Stripping ena Tom Connection data, output ‘Connection mathod Pushin connection ‘Conduciar e038 seston said min Da mane ‘Conductor ose section sold max 25 nae ‘Conductor cross section flexible min D2 mane ‘Conductor ross seaionflexble max: 25 mene ‘Conductar cress section AWG min. 2 ‘Conductor cress saction AWG max 1% ‘Stipping enath Toma Connection data for signaling ‘Conneaton method Pusirin connection ‘Conductor oss section sold min Da ane er1272020 Page 3/12 ito: proarixcontact. con pifproducs/2004605 CQPHEND Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Technical data Connection data for signaling ‘Conductor ross section sold max. 25 men? ‘Conductor ross section flexible min 02 mF ‘Conductor cross section flexible max 25 nF ‘Conductareross section AWG min. 2 ‘Conducter cross section AWG max 1% ‘Stripping engi Tomm Standards ‘Standard Safety of wansformers EN 1560-216 “Standard safely for equipment for measurement, contro and eCoIIod laboratory use ‘Standerd— Safety exreow votage TEC BI010-1 SEL) TEC B10102-201 (PEL) “Sianderd- Safe solation TEC SIsSe216 “Standard Linfation of mains harmonic currents EN 6 T0002 Conformance/approvals UL approvals UL Listed UL 610107 UL Listed UL S101 2201 UL 1310 Clase 2 Pawor Unis [ANSVUL 121201 Class, Dison 2, Groupe A.B, ©, D (Hazardous Location) sa (CB Scheme (EO B1010-1, EO 10102 201) EMC data Elecromaaneiio compatibity Conformance with EMG Directive 2014/90U ‘Conducted noise emission ENSSOT6 EN61000.6.3 (Glass 8) Noise emission EN 55016 EN 61000-6-5 (Gass 5) Harmonie curents EN 6100032 EN 1000-52 (Gass A) Fckar EN 61000-3 Flecromatio decharge ENS T0002 ‘Contact dscharge BAY TestLevel Discharge in air TSKV (Tost Level 4) Elactomagnoilo HF fald EN 100043 Frequency range SOMME. 1GHe Test fold strength 2O Vira (Test LevelXy Frequency range 1 Gre. 6GHE Test field strength TO Vin (Fest Level 3) Comment Criterion A Fast transients (burst) EN 610004 0971272020 Page 12 ito: proarixcontact. con pifproducs/2004605 Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Technical data EMC data Input “4 RV (Test Lovel 4 asymmeuica) Ouiput 4 AV (Test Level X- asymmetiioad) ‘Signal 4 AV (Test Level X- asymmetiioal) ‘Commants Criterion A ‘Surge voltage load (surge) EN 6100085 Input 2 xV (Test Laval 4 aymmatoal [ARV (lest Level 4 asymmetrical) Output TAY (Test Level 3 aymnmetioa 2AV (Tost Level 3 asymmetical ‘Sonat DS KY (Test Laval 2 eymnmatioad ‘Comments Greron A ‘Conducted interference EN 6100046 TOs ‘asymnmotical Frequency range O15 Me .. 80 ME Voraas TOV (Tost Levels) ‘Commons rerio A Powor frequency magnetic fold EN 6100046 Frequency 1687 He B0re b0re Test reid arena Toa ‘aaational text ee ‘Comments Gren A Frequency SORE Bore Frequency range BORz.60He Test fold aronath TA ‘Addtional text 3 Frequency Ore “Test field strength 300 Alm ‘Addtional text DG.608 Votege dps EN 61000-6717 vous Toa VAG Frequency core Votege dip 70% Number of parods| 0571730 poriods ‘adtional ext Test Laval? ‘Comments Criterion A Vonage ip 40% Number of periods 10750 periods er1272020 Page 5/12 ito: proarixcontact. con pifproducs/2004605 Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Technical data EMC data ‘Addtional text Test Level 2 ‘Comments Criterion Votage oip 0% ‘Number of periods 05/1/51) 80 perods ‘Adational txt Test Level? ‘Comments Cerion & Pulse-shape magnetic ela EN61000-69 Test fold strength 1000 Aim ‘Comments Grteron A “Aentated sinusoidal osatations (ang wave) EN 61000812 input 2 AV (eymmaricad 4 RV (esymnmetica) Commons CGreron A “Asymmetrical conducted disturbance variables ENOT000-216 Test vel 16.07 HE 50 He OO He 150 He 180 He (Tost Level) Vousas 30 GOs) Test lovel2 16.67 Fiz 50 He 60 Fz (Test Lovel 2) Volos 300 (1s) ‘Comments Creo A ‘Atenucied oacilating wave EN 1000-618 vous TAY (@ymmetcad 2.5 KV (@symimatioa TAY (oymmetcad Commants Gren A Galierion A ‘Normal oparaing btavior within the speciied iis Gaap Terror mparmerio operational ohare corecod byte Temporary aaverse effects on he operating behavior. whieh the catteron & vice corrects automatically or which can be restored by actuating the ‘perating ements Drawings er1272020 Page 6/12 ito: proarixcontact. con pifproducs/2004605 PHCENIX Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 ‘Schematic diagram Housing Input Signaling CO) Lo— & —o NnO— A 0 A Output —o- —o- Block diagram ra i 1 ic y 09/1212020 Page 7/12 ito: proarixcontact. con pifproducs/2004605 COPHEND Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Diagram ea0.40 = Uy: 120 V AC/Ug,:: 12 V DC — @=U,:230 V AC/Uy,.: 12 VDC 00 05 #10 15 20 25 30 3,5 = Nou [Al Diagram e 2 N Power Factor oe esseses cot NORD 120V ACI: 12VDE — In: 230 V ACU: 12 V DC n 1 I I 0,5 1,0 15 2,0 25 3,0 3,5 oe lou [Al 09/1212020 Page 8/12 https phosnixcontact.com/pifproducts/2004605 PHCENIX Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Diagram z 95; S| 90 w .. o 80} 75: | Uy: 120 V AC/Up4: 12 V DC 70 U,:230 V AC/U,.: 12V DC | a py 0 Of 10 15 20 25 30 3,5 a Nou [Al Classifications ecl@ss eos oT TraaDTOT 20103551 wr242a13 ac1@s 60 77040000 SaOS TO 1048002 01055 80 77040002 ais 90 TrOA0TOt TIM ETS ECO ETMG0 EODO25A ETM 70 EODO25A0 UNSPSC ORSPSO TEE Tornoe UNSPSC 160 woiRioge UNSPSC 180 a07Di008 UNSPSCZOO erzi00e UNSPSC21O S01DI008 Approvals Approvals 971272020 Page 9/12 https phosnixcontact.com/pifproducts/2004605 CQPHEND Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Approvals Approvals UL Listed /IECEE Ca Scheme /oUL Listed / EAC / DNV GL / oiLus Listed Ex Approvals UL Listed / cL List / cULus Listed Approval details UL Ustea hntpsidatabase uLcomicp-binXYVitemplata/LISEXT/IFRAMBlindex tim — FILE E 123528 IECEE CB Scheme Intpsiweviaces 0g shone sage ‘UL Listed ‘ hntp/Satabase uLcomiog-bivxXYViemplata/LISEXT/IFRAME/ndex tim — FILE E 123528 “ EAL RUDE EO187a DNVGL hitps:/lapprovatinder nal com ‘TAROQOOISN sd Q« Accessories Accessories Device protection (09/1212020 Page 1012 ito: proarixcontact. con pifproducs/2004605 COPHEND Power supply unit - QUINT4-PS/1AC/12DC/2.5/PT - 2904605 Accessories Type 3 surge protection device - PLT-SEC-T3-230-FM-UT - 2807819 4 “Typo 213 surge protection, consisting of protective plug and base element wit screw connection. For single-phase power supply natoorc wth integrated status indicator and ermots signaling. Nominal voltage 230 V AIDC. Type 3 surge protection device - PLT-SEC-T3-24-FM-UT - 2907916 “Type 3 surge protection, consisting of protective plug and base element, with integrated status insiestar and remote. ‘signaling fr inglo-phase power supply networks. Nominal vltage 24 V ACIDC. Type 8 surge protection device - PLT-SEC-T3-230-FM.PT - 2007028 “Type 218 surge protaction, consisting of protective plug and basa element with Pushin connection. For single-phase power supply network With iniagrated slats indlcaior and variate signaling. Nominal voliage 230 V AC/DC. Type 3 surge protection device - PLT-SEC-T3-24-FM-PT - 2907825 “Type 3 surge protection, consisting of protective plug and base element, wth integrated status insiestar and remote ‘signaling for inglo-phase power supply networks. Nominal vllage 24 V ACIDC. Screwdriver tools Screwdriver « SF-SL 0,4X2,0480 - 1212546 Sorowrsiver Nat bladed, siz: 0.4 x 2.0.x 60 mm, 2-component ap, wth Nen-aip arp (08/1212020 Page 1112 ito: proarixcontact. con pifproducs/2004605 Phoendx Contact 2020.9 - all rights reserved htp:fwew.phoanbcontact.com PHOENIX CONTACT GmbH & Co. KG Flachsmerktstr. 8 32825 Blomberg Germany Tel, +49 5235 300 Fax +49 5235 3 41200 httpuwww.phoenixcontact.com. CQPHEND (09/1212020 Page 12/12

You might also like