SHREYASH ENTERPRISES Unit- 1: LC-108, Sec. 21, Yamuna Nagar, Nigadl, Pune - 411 044, Unit -2 : 203, B-17, Swapnanagari, Telegaon - Chakan Road, Talegaon Dabhade, Pune - 410507. cc-2113, Mob. : 09822695961, 09067592861, E-mail : mukesh.navalakhe@gmail.com CALIBRATION CERTIFICATE ULR No. (Unique Lab Report No.):_ ULR-CC211322000002641F Certificate No. ‘SE 22.04.0090, (Calibration Date (08/04/2022 Certificate Issue Date 08/04/2022 |Next Calibration Due Date 07/04/2023 Work Order No. 455-13, (As per Customer Requirement) Date of Receipt 8/04/2022 Page No, tof |Customer Name & Address © Mis. Bharat Tanks & Vessels LLP, Gat No.647, Pimpri Budrukh, Khed, Pune. Location of Calibration + Location-1 (Lab - Nigadi) ‘stomer Reference BTV-MI-CH-01 (Thr. M/s. Radha Krishna Associates.) Dated: 08/04/2022 Name & Description of Measuring Tape item Under Calibration Range: 0to1Smtr. = LC. : 1mm Make. FREEMANS uc) Id.No. : BTV/6M/MT/O1 Sr.No. © L 109-19 Condition of item at Receipt Visually ok (Calibration Method ‘Our Calibration Method No.: SE/CM/43, Reference Standard: IS 1269 (Part 1 & 2) [Environmental Conditions Temperature: 20 + 2°C & Humidity: 40 to 60 % Rh STANDARDS & MASTER EQUIPMENTS USED : Name of Master Equipment/ | 1D.No./ Sr.No. | _ Calibrated By Certificate No. Valid Upto Reference Standard Tape & Scale Calibrator SEMTSCIO COATT SE21.11,0080, 097172022, [Traceability: Traceable to National / International standards through NABL Accredited calibration laboratory [Mechanical Calibration (Dimension) CALIBRATION RESULTS (All Readings are in mm) Standard] “OBSENEE | irq, | Standard | Observed | co, | Standard] Observed | Reading | Reading Reading | Reading* Reading | Reading 0.0 0.000 [0.000 | 2000.0 | 2000277 | -o277 | 000.0 | 8000 842 40.0 40.178 | 0.478 | 3000.0 | 3000.04 | -0.404 | 9000.0 | 9000764 7100.0 700.425 | 0.125 | 5000.0 | 5000.23 | 0.423 | 1000.0] 10000.846 500.0 499798 [0202 | 6000.0 | 000.488 | -0.488 | 100000] 12000.981 0000 | 1000.156 | -0.156 | 7000.0 | 7000611 | -o6t1 | 150000 | 18007.237 Note: Standard reading is the reading set on Tape (UC) hc Uncertainty of £0.5mm qa \ [Measurement (at confidence level of 95.45% & coverage factor k=2) ie Maximum Perms Bor as per G. 6.1 of S 1269 Pal. Vaues main ] Gass] Forma "Loin rer mre [at etstTa>slel7 [elem ne] ms Tuyis I |zor+01f 2 [os [oa los|oo}or}oafos|io[ 11] i2}istaatiep ie iW Jzosr02nf 05 [or [oolsi] 19} 15117] 19] 21| 25] esl ertesfart ss w= |xosroanf 10 [14[iel22|20]s0ls«lselazlas]solestestes[ee SEN} Shivaji ‘a SENN Harshal More / Mukes falakhe (Sr. Calibration Engineer / Lab Manager) Approved By TD, Calibrated By{Calibration Engineer) SECC, Aen Ne 2 Arend BU OSES? ‘The calibration resulis reporied in this certificate are vald atthe a ‘stated condition of the measurements, ‘The caltoration cotificate shal not be reproduced except in fll, without writen approval ofthe Shreyash Enterprises This Certificate relates only tothe tem Calibrated YOOXX—-END OF REPORT——XXXX SHREYASH ENTERPRISES Unit 1 : LC-10B, Sec. 21, Yamuna Nagar, Nigadi, Pune - 411 044, Unit -2 : 203, 8-17, Swapnanagari, Talegaon - Chakan Road, Talegaon Dabhade, Pune - 410507. cc-2113 ‘Mob. : 098228959611, 0906759286, E-mail : mukesh.navalakhe@gmail.com CALIBRATION CERTIFICATE ULR No. (Unique Lab Report No.) ULR-CO211322000002634F (Certificate No. ‘SE.22.04.0083, (Calibration Date 08/04/2022 Certificate Issue Date 08/04/2022 INext Calibration Due Date 07/04/2023, lWork Order No. 455 -6 (As per Customer Requirement) Date of Receipt 08/04/2022 Page No, toft |Customer Name & Address © M/s. Bharat Tanks & Vessels LLP, Gat No.647, Pimpri Budrukh, Khed, Pune. Location of Calibration Location-1 (Lab - Nigadi) ustomer Reference BTV-MI-CH-01 (Thr. Mis. Radha Krishna Associates) Dated: : 08/04/2022 Name & Description of Measuring Tape Item Under Calibration Range: OtoSmtr. Le. : 1mm Make FREEMANS \(uc*) Id.No. : BTVISM/MTIO1 Sr.No, : $ 225-19 |Condition of item at Recei Visually ok |Calibration Method (Our Calibration Method No.: SE/CM/43, Reference Standard: IS 1269 (Part 1 & 2) Environmental Conditions ‘Temperature: 20 + 2°C & Humidity: 40 to 60 % Rh |STANDARDS & MASTER EQUIPMENTS USED : Name of Master Equipment / 1D. No./Sr. No. | Calibrated By Certificate No. Valid Upto Reference Standard Tape & Scale Calibrator SEMTSCIOI C2118 ‘SE21.11,0080 0971172022, [Traceability: Traceable to National International standards through NABL Accredited calibration laboratory Mechanical Calibration (Dimension) CALIBRATION RESULTS (All Readings are in mm) Standard] Observed Standard | Observed L. Reading | Readinge | ©" | Reading | Reading | ENO 0.0 (0.000 | 0.000 | 1000.0 | 1000.130 | -0.130 10.0 e982 | 0008 | 2000.0 | 2000272 | -0272 700.0 100.160 [0.160 [30000 | 3000215 | -0.215 300.0 300.551 | -0551 [ 40000 | 4000393 | 0.303 5000) 500.366 | -0.356 | 6000.0 | 500.824 | -0.624 Note: Standard reading is the reading set on Tape (TUC) [Uncertainty of £0.30mm [Measurement (at confidence level of 95.45% & coverage factor k=2) Maximum Permesibie Error as per G. 6.1 of lS 1269 (Part @)- Vakies n= mm [Gass] Formaia "Lin wer am nme [4 ?atst«ts,e,r[el|slo[n] mlm, mis [= |xo70.15[ 02 [os foal osloelo7}oslos|io[i11}12]13[ aa] is[ie n—|x0020[ 05 [or [ool i1{13[15]17]19]21]23|25]27]| 20 arpa w-|xoeroary[ 10 [14] 18]22|26]s0[s4}sel2]as]solsalcele>lsc Shivaji E Harshal More / Mukesh Navalakhe [free (Ci bration En, ‘SEICCISTION, Amend. No: 02, Amend Di 3170472024 ‘The calibration results reported in tis cortficae are all atthe trie of and under stated condition of te measurements ‘The calipation certificate shall not be reproduced except in fl, without wien approval of the Shreyash Enterprises ‘This Certificate relates only tothe tem Calibrated. XXXK--END OF REPORT-—XXXX SHREYASH ENTERPRISES CALIBRATION CERTIFICATE Certificate No. SE.22.04.0128 (Calibration Date 08/04/2022 Certificate Issue Date: 08/04/2022 Next Calibration Due Date 07/04/2023, Work Order No. 456-21 (As per Customer Requirement) Date of Receipt oaio4r2022 Page No 4oft Customer Name & — : M/s. Bharat Tanks & Vessels LLP, |Address Gat No 647, Pimpri Budrukh, Khed, Pune, Location of Calibration; Location-1 (Lab - Nigadi) [Customer Reference: BTV-MI-CH-01 (Thr. M/s. Radha Krishna Associates.) Dated: 08/04/2022 Name & Description : Bevel Angle Gauge lof Item Under Size eorto7s = LG. Make = - Calibration Id.No. : BTVIBAG/OL Sr.No. 2 = [Calibration Method: InstumentalExor was determined a8 per our metod SECMITO Environmental Temperature: 20 + 2°C, Humidity: 40 to 60% Rh |Conditions |Master Equipment / Standards Used For Calibration & its Traceability: Name of Master Equipment’ ] 1D.No./Sr.No. | _ Calibrated By Certificate No Valid Upto Reference Standard Digital Bevel Protractor ‘SE/DBPION Coats Sezio2.046 | 147022025] ‘Traceability: Traceable to National / International standards through NABL Accredited calibration laboratory Mechanical Calibration (Dimension) CALIBRATION RESULTS Nominal Angle of UC ‘Observed Angie \ an: sar we - = 8 i ora j ce 3 76 70 a = 7 ON UC: item Under Calibration \ ‘Uncertainty of +35 min Measurement (at confidence level of 95.45% frpeverage factor k=2) Se Harspral More oF oy Mukesh Navalakhe pute — \ CAB hue Calibrated By (Calibration Engineer) Approved By (Lab Manager) ‘SEICCIAPIO, Amend. No. O1, Amend. DL OUDUEDIS “The clan ress reported nts Gericaa ave vaid ate Une of and unde Hated cordon ofthe messurements The calixaton carte shal not be reproduced except in fl wihout itn aorovl fhe Steyash Enterprises Ths Catia laos ony tothe tm Carats YOO END OF REPORT—XXXK

You might also like