You are on page 1of 1

0 1 2 3 4 5 6 7

Chopping Measuring Capacitive Capacitive


spark gap sphere gap voltage divider voltage divider

Unit allocation
+AFC AFC 670/2400
+AS MIAS 100-14/4 B
+BG BG 5I (E)
+GE GEOS 100/ 2x100 +IG +AFC +KF +SMC1 +SMC2
Earthing Earthing
A +IG IG 240/2400 G Impulse voltage generator Rd A
+KF MKF 50
rope 1 -Cs2 rope 2
+MR SMW 10000
+OD OD 130 I
+SMC1 SMC 670/2400 -Rd -Rd Test object *)
+SMC2 SMC 4000/400
+ST ST 6
Re
Rl2 -Co -Co
-Cs1

-Rd -Rd
Rl1 Rd
-Cs2 Impulse current
Ignition measuring
generator
resistor
Charging voltage Charging voltage
measurement 1 measurement 2 H366

+ST MFK +MR


+GE Charging unit B1 B2
Re device
Control unit -Cs1
U1
-Rv1 M
-W6 U2 -Rdu -Rdu
25 mm² 25 mm² G -T1 -C1 -Rv2
B Cu Cu -T2 3x25 Rearth Rearth Rm Rm B
*) -AT2 *) -XS0 -K1 -Rm
-X0 -F3 100/1A 25kVA Impulse
-Ck1 detection
L1
L2 v -Cu -Cu
100A 250A k l -C2
2PE, 415V, 40kVA, 50Hz

very slow 2 3NE4327-0B


Power supply power *)

Fan
*) -W15
-T3 V1 -A20 CY PiDY (TP)
100/1A 5x2x0,25
-F2
L1 u 0
L2 U1 U2 to_ST
k l V1 1.5:C
100A 250A
3NE4327-0B V2 Earthing Earthing
very slow 2 PE switch 1 switch 2
*)
+/- -XU1 -XU2 lg. Earthing device Earthing device Ch. spark
drive -QI1 -QI2 spark gap dev 1 2 gap dev.
PE
PE

H366
B2
H372
M M M M M M
415V/400V B1
40kVA -W5
CY PiDY (TP)

Motor

Motor

Feedb.
IN PE 5x2x0,25
I> -XE.. -XE..
-MI2 -MI3/4 -MI4/5 -XI2
M Ignition
generator
-K2 IN -XI4
to_ST / 1.6:B
adj.:0,66A
I>
M -X1 -WI18
C LiYCY C
-K3 4x0,75
adj.:0,66A -WI17 -W51 -W53
FSMA
G 2FSMA
4x1

-W52
-W2.1 -WI3 -WI4 -WU1 -WU2 -WI1 -WI2 -WI5 -WI11 -WI7 2FSMA -W11 -W12 -W13
LiYCY G G RG58 RG58 G G CY G G CY G L35 L35 L35
2x0,75 3x1 3x1 4x1 4x1 4x1 4x1 4x1
-W2.2 -WI9 -WI6 -WI12 -WI8
LiYCY LiYCY CY G LiYCY CY G
2x0,75 4x0,75 4x1 4x0,75 4x1

-AT1 -W3 -W55 -WI10 -WI13 -WI15


3NPE,240/415V, 3kVA, 50Hz

LiYCY G LiYCY G G
Power supply Control *)

G 3 G 4x0,75 5x0,75 4x0,75 3x1 3x1


5x2,5 5x2,5
*) *) -XS1 -WI14 -WI16
-X10 Control/ G G
Power supply 3x1 3x1

-X5
3 -XS1
I charge (2) I charge (1)
Δ/Y measuring measuring
D 415V D
230/400V
4kVA
-WS53
2FSMA
PROFIBUS DP

Thyr.-erg. +/- Earth switch Earth switch Fan lg. spark Earth. dev. MFK Ch. spark Earth. dev.
drive drive drive drive drive gap drive drive drive gap drive drive
-WS20
L123
+Safety X2/DP
X2 X5 B1 B2 B5 B3 B4

Profibus-DP

Ready 1

Trig 1

Impulse

Ready 2

Trig 2
-A2
AI 8 x 12BIT
*)
-X2 -A1 -A1 -A4 -A5
CP343-LEAN H 405-DP
CPU 314 C-2 DP CPU 314 C-2 DP
Safety -A3
box DO16 Profibus-DP Phase
-W23 RJ45 X15 B7
G

UN6332-1S
16x1
-WS30
L142

RJ45
T R
-B3
FL Switch
E R T E
-WS31 -WS21
SC BF0C
-XS1 -X3 -X4 -X6

-X1

-W1 PROFIBUS DP -W20


L4 BF0C
8x1

TCP/ IP -W30
+OD SC
-X1
+BG -W31
PROFIBUS DP SC

R
-A109
IF1B -X4 CH1
UN6332-1S T
OP177 B IPC
-WB1 to LAN
L123 *) +AS
RDA 23
Operator device Measuring/ CH2
Evaluation system
Mains

F Mains (switched) RA 50-1 F


1NPE~ 50/60Hz 230V -X3 Mains
CH3

50 Ohm

Date 28.07.2009 Prime Electric Ltd. Overall circuit diagram = IP


HIGHVOLT Prüftechnik
*) Not contained in this order Ed. Dan Keller General circuit diagram +
Appr Impulse voltage test system (1) S4009-S003-01- 7612 Page 1
Modification Date Name Original 523411_IPL_360_2400_G.ell Replaced by Replaced by ID: 56058 AKZ: 523601 IPL 240/2400 G Page 13
0 1 2 3 4 5 6 7

You might also like