You are on page 1of 18
REPORT OF (ON No.0270-02-BPC/0003/E10-L11/P8/2022 CLIENT : PT. KOTA MINYAK INTERNUSA JOB TITLE : CALIBRATION NAME OF EQUIPMENT —:_ DIGITAL PRESSURE GAUGE DATE OF CALIBRATION: FEBRUARY 26, 2022 LOCATION : LABORATORIUM KALIBRASI PT BIRO KLASIFIKASI INDONESIA (PERSERO) CABANG UTAMA KOMERSIL BALIKPAPAN bki PT. BIRO KLASIFIKASI INDONESIA (PERSERO) COMMERCIAL MAIN BRANCH OF BALIKPAPAN 2022 SUMMARY REPORT. PAGE iit REPORT No. : 0270-02-BPC/0003/ REF. NO : Ee E10-L11/P8/2022 DATED : MARCH 04, 2022 TITLE of REPORT CLIENT / SPONSOR OF PROJECT CALIBRATION OF DIGITAL PRESSURE PT KOTA MINYAK INTERNUSA GAUGE CLIENT / SPONSOR OF PROJECT PT BIRO KLASIFIKASI INDONESIA (PERSERO) BALIKPAPAN COMMERCIAL MAIN BRANCH SM OPERATION & MARKETING PT KOTA MINYAK INTERNUSA WORK CARRIED OUT BY PT BIRO KLASIFIKASI INDONESIA (PERSERO) BALIKPAPAN COMMERCIAL MAIN BRANCH CUNDUCTED BY ARDI ARIANTO Based upon records of calibration there are summarize as follows : | Location ‘TYPE OF UNIT TOTAL UNIT | RESULT a eae ean 4 (one) unit Certificate of Calioration Batkpapan | ee er tsps 1 (one) unit | Certificate of Calibration CIENT 2625pst i (one) unit | Certificate of Calibration Pwene COVER . SUMMARY REPORT |. REPORT OF CALIBRATION . CERTIFICATE OF CALIBRATION 4.1, PRESSURE GAUGE CAPACITY 0 - 40bar / 580psi 4.2, PRESSURE GAUGE CAPACITY 0 - 70bar / 1015psi 4.3. PRESSURE GAUGE CAPACITY 0 - 25MPa / 3625psi . APPENDIX 5.1. COPY CERTIFICATE OF PERSONNEL 5.2. COPY ACREDITATION OF LABORATORY 8482: PT. BIRO KLASIFIKASI INDONESIA (Persero) Cabang Utama Komersil Balikpapan 1964 T OF CALIBRATION Report No. : 0270-03-BPC/0003/E10-L11/P8/2022 THIS IS TO CERTIFY THAT, based on the request of PT. Kota Minyak Internusa, Calibration Laboratory of PT. Biro Klasifikasi Indonesia (Persero) Balikpapan of Commercial Main Branch Office has been carried out calibration for “Digital Pressure Gauge ” with the result as follows : A RAL INI TION Principle : PT. Kota Minyak Internusa Job Description 1 Calibration of Digital Pressure Gauge Date of Calibration : February 26, 2022 Place of Calibration : Balikpapan Number of Equipment 3 (three) Units B. RESULT of CALIBRATION 1, Pressure Gauge cap. 0 ~ 40bar / 580psi Nilai Standar Penunjukan Alat Koreksi (psi) (osi) (psi) Ketidakpastian Naik Turun Naik Turun Naik Torun 0 0 0,0 0,0 0,0 0,0 50 50 49,75 49,75 0,25 -0,25 100 100) 99,95 99,95 -0,05 -0,05 160 160 160,86 | 160,86 0,86 0,86 220 220 218,86 | 218,86 | -1,14 =1414 280 280 278,95 | 278,95 =1,05, “1,05 0,8 psi 340) 340 338,66 | 338,66 =1,34 =1,34 400) 400 399,85 | 399,85 “0,15 “0,15 460 460 | 458,85 | 458,85 “1,15 “1,15, 520 520 518,55 | 518,55 “1,45 “1,45, 580) 580, 579,25 | 579,25 “0,75 “0,75 2. Pressure Gauge cap. 0 - 70bar / 1015psi Nilai Standar Penunjukan Alat Koreksi (psi) (psi) (psi) Ketidakpastian Naik Turun Naik Torun Naik Torun 0 0 0,0 0,0 0,0 0,0 90 90 89,85 80,85 0,15 -0,15 180 180 179,85 |" 179,85 “0,15 0,15 360) 360 360,95 | 360,95 0,95 0,95 450 450, 450,95 | 450,95 0,95 0,95 540 540 540,95 [540,95 0,95 0,95 1,4 psi 640 | 640 640,95 | 640,95 0,95 0,95 780 780, 779,95 | 779,95 -0,05) -0,05 920 920 920,25 | 920,25 0,25 0,25 950) 950) 955,48__| 955,48 5,48 5,48 995) 995 994,85 | 994,85 -0,15 -0,15 B. 1 PT. BIRO KLASIFIKASI INDONESIA (Persero) —___ Cabang Utama Komersil Balikpapan 1964 3. Pressure Gauge cap. 0 ~ 25MPa / 3625psi Nilai Standar Penunjukan Alat Koreksi (psi) (psi) (psi) Ketidakpastian Naik Turun Naik Turun Naik Turun 0 0 0,0 0,0 0,0 0.0 400) 400 400,95 | 400,95 0,95 0,95 800) ‘800 800,95 | 800,95 0,95 0,95 1200 1200 | 119995 |" 1199,95 | -0,05 0,05 1600 1600 | 1601,95 | 1601,95_|~_1,95 1,95 2000 2000 | 200,95 [201,95 _|_1,95 1,95 4,8 psi 2300 2300 | 2301,95 | 2301,95 1,95 1,95 2600 2600 | 2601,95 | 2601,95 1,95 1,95 3000 3000 | 299,95 | 2999,95 |" -0,05 -0,05 3300 3300__ [302,95 | 3302,95 [2,95 2,95 3600 3600 | 3601,95 | 3601,95 | 1,95 195 NOTE : Final result of calibration see on the certificate as attached. Balikpapan, March 04, 2022 Head of Balikpapan Commercial h Operator Ardi Arianto {+ PRESSURE GAUGE S/N. SDI2 5-L-3-1-020 |] CAP. 0 — 40bar / 580psi BALIKPAPAN COMMERCIAL MAIN BRANCH bki PT. BIRO KLASIFIKASI INDONESIA (Persero) Vi ‘KAN JLMTHaryono No.8 Rng Road BALIKPAPAN ~76326 LK-254408 Phone: (462-542) 876642, 576643, ‘omal: oe@bidco.id 'so/tec 17025:2017 SERTIFIKAT KALIBRASI iLIBRATION CERTIFICATE Nomor —: 010-PG-LK254-BPC-22 Number ALAT Hal 12 Equipment 1 Nama Pressure Gauge 4 Kapasitas 40bar / 580 psi Name Capacity 2 Type/Model Digital / Gi92-001 5 Resolusi i 1 psi ‘iypecmoaet ‘Kesotutton 3 MerkiBuatan : Brothoterm 6 Nomor Seri SDI2.5-L-3-1-020 ‘Manufacturer Dental Number ILIK Owner 1 Nama PT Kota Minyak intermusa Name 2 Alamat A. Jend, Suditman No.12 Kel. Damai - Balikpapan Adeiress STANDAR Standard 1 Nama DWT - Budenberg / CPBS800 Name 2 Ketelusuran — : Hasilklibrai yang dilaporkan tertelusur ke Satu Pengulran SI melalui LK-057-IDN Traccabiniy TANGGALDITERIMA Ta 26 Februari 2022 Date ofaccepiance — 22.¥eb, 2021 ‘Late of calibration KONDISL Suhu/Temp, Kelembaban -Exwrronment condition of calioration 20°C 7% LOKASIKALIBRASI Laboratorium Kalibrasi - PT BKI Cabang Utama Komersil Balikpapan ‘Location of calibration ‘ODA, SL Pressure Gauge in dikalibrasi dengan menggunakan alt Standar Dead Weight Tester Calibration method dengan nomor sei CPBS800, ketertuusaren ke Satan Laernasinal (SI) mela Laboratorium Kalibrasi Global Quality Indonesia LK-0S7-IDN ‘Metode kerja yang digunakan sesuai dengan Prosedur Mutu Laboratorium Kalibrasi PT Bito Klasifikasi indonesia (Persero) No. : WI-LAB-18 issued 04 ACUAN BS/EN 837-1 : 1998, ISOMEC Guide 98-3:2008, DKD-R 6-1:2014 ‘Kejerence LD, "ASTIAN. RAST it ‘Kesulf of calbration and uncertainty of caloranon (attached D (04 Maret 2022 ‘Date of sssue bki PT. BIRO KLASIFIKAS! INDONESIA (Persero) KAN BALIKPAPAN COMMERCIAL MAIN BRANCH JL MT Haryono No. Ring Road BALIKPAPAN —76214 Phone: (462-542) 875582, 876643, mal: boc@bkicoid ISO/IEC 170252017 LAMPIRAN SERTIFIKAT KALIBRASI Attachment of calibration certificate Hal22 Noor 010-PG-LK254-BPC-22 Tanggal 04 Maret 2022 Number Date 1. Hasil Kalibrasi osull of Calioraton ‘Nilai Standar Penunjukan Alat Koreksi Ketidakpastian (psi) (psi) (psi) | Uncertainty *) Naik | Turun Naik Turun Up_| Down (psi) 0 0 0,00 0,00 0,00 | 0,00 50 50 49,75 49,75 0.25 | -0,25 100 | 100 99,95 99.95 -0,05 | -0,05 160 | 160 160,86 160,86 0,86 | 0,86 220 | 220 218,86 218,86 Aid | 114 280 | 280 278,95 278,95 -1,05 | -1,05 08 340 | 340 338,66 338,66 -134 | 134 400 | 400 399,85 399,85 -0,15 | -015 460 | 460 458,85 458,85 LAs | -115 520 | 520 518,55 518,55 “145 | -1,45 580 | seo 519,25 579,25 0,75 | 0,75 ‘Note: *) Keiidakpastian yang dilaporkan adalah Ketdakpastian bentangan dengan tngkat Kepercayaan 95% dan faktor cakupan ke2 DILARANG mengutip/memperbanyak SERTIFICAT ita tlh ina BALIKPAPAN COMMERCIAL MAIN BRANCH JL.MIF Haryona No.8 ng Road BALIKPAPAN ~76124 UG264108 Phone: (462-542) 875642, 876543 emai: be@blico.d bki PT, BIRO KLASIFIKASI INDONESIA (Persero) Vi ‘KAN ISO/IEC 17025:2017 SERTIFIKAT KALIBRASI CALIBRATION CERTIFICATE Nomor — : 011-PG-LK254-BPC-22 Number ALAT Hal 12 Equipment 1 Nama 1: Pressure Gauge 4 Kepesitas ‘TObar / 1015 psi Name Capacity 2 TypeModel —: Digital /G192-5001 5 Resolusi 1 psi ‘DypetModet ‘xesolution 3 Merk/Buatan : Brothoterm 6 Nomor Seri. SDI2.5-L-3-1-070 Manufacturer ‘Serial Number MILIK Owner 1 Nama PT Kota Minyak Intemusa Name 2 Alamat Il Jend, Sudirman No.12 Kel. Damai - Balikpapan Address STANDAR ‘Standard 1 Nama DWT - Budenberg / CPB5800 Name 2 Ketelusuran —: Hasilkalibrasi yang dilaporkan tertelusur ke Satuan Pengukuran SI melalui LK-057-IDN Traceaoility TANGGAL DI TANGGAL KALIBRAST 26 Februari 2022 Dale of acceprance 22Feb, 2022 Date of canoration KONDISL UNGANKALIBRASI: Suhu/Temp. Kelembaban, Environment condition of calibration 19 61.5% LOKASIKALIBRASI Laboratorium Kalibrasi - PT BKI Cabang Utama Komersil Balikpapan ‘Locanon of cauibration METODA KALIBRASL ‘Pressure Gauge ini dikalibrasi dengan menggunakan alat Standar Dead Weight Tester Calibration method {dengan nomor seri CPBS800, ketertlusuran ke Satuan interasional (SI) melalui Laborstorium Kalibrasi Giobal Quality Indonesia LK-057-IDN ‘Metode kerja yang digunakan sesuai dengan Prosedur Mutu Laboratorium Kalibresi PT Biro Klasifikasi indonesia (Persero) No. : WL-LAB-18 issucd 04 ACUAN ‘BS/EN 837-1 : 1998, ISOMEC Guide 98-3:2008, DKD-R 6-1:2014 Kefjerence RASI DA KALI ‘Clerlampir) ‘Result of calibrattion and uncertainty of calibration (Attached) DITERBITKAN TANGGAL: 04 Maret 2022 Date of rssue bki PT. BIRO KLASIFIKASI INDONESIA (Persero) VKAN BALIKPAPAN COMMERCIAL MAIN BRANCH LMF Haryono No. ing Road BALIKPRPAN ~76114 UC25HI0N Phone: (+62:582) #76082, 875643 ‘email: oobi coig ISO/IEC 17025:2017 LAMPIRAN SERTIFIKAT KALIBRASI Attachment of calibration certificate Hal 2/2 ‘Nomor 011-PG-LK254-BPC-22 ‘Tangeal 04 Maret 2022 ‘Number bate 1. Hail Kalibrasi Result of Cabioraton Nilai Standar Penunjukan Alat Koreksi__| Ketidakpastian (psi) (psi) si) J Uncertainty *) Naik _|Turun Naik ‘Turun Up_| Down (psi) 0 0 0,00 0,00 0,00 | 0,00 90 Ei) 89,85 89,85 0,15 | -0,15 180, 180 179,85 179,85 0,15 | -0,15 360 360 360,95 360,95 0,95 0,95 450 450 450,95 450,95 0,95 | 0,95 540 540 540,95 540,95 0,95 0,95 14 640 640 640,95 640,95 0,95 0,95 780 780 779,95 779,95 0,05 | -0,05 920 | 920 920,25 920,25 0,25 | 0,25 950 | 950 955,48 955,48 5,48 | 548 995 | 995 994,85 994,85 0,15 | 0,15 Note: *) Ketidakpastian yang dilsporkan adalah Ketidakpastian bentangan deogan tingkat Kepercayaan 95% dan faktor cakupan k=2 | PRESSURE GAUGE S/N. 2002 254056204 CAP. 0 — 25MPa / 3625psi PT. BIRO KLASIFIKASI INDONESIA (Persero) VKAN b BALIKPAPAN COMMERCIAL MAIN BRANCH — JI. MT Haryeno No Ring Road BALKPAPAN ~76114 U25440N Phone: (362-542) 876642, 576543 ema: boc@bKicoid ISO/IEC 17025:2017 SERTIFIKAT KALIBRASI ‘CALIBRATION CERTIFICATE Nomor : 012-PG-LK254-BPC-22 Number ALAT Hal 12 Equipment 1 Name Pressure Gauge 4 Kapasitas 25MPa//3625 psi Name Capacity ‘2 TypelModel Analog /G192-5001 5 Resolusi | psi ‘Typetmodet Kesolution 3 Merk/Buatan —: Brothoterm 6 Nomor Seri 2002 254056204 ‘Marugacturer Serial Number PEMILIK Owner 1 Nama PT Kota Minyak Internusa fame 2 Alamat IL Jend. Sudirman No.12 Kel, Damai - Balikpspan Aaaress STANDAR ‘Standard 1 Name : DWT -Budenberg / CPBS800 2 Ketelusuran = Hasitkalibrasi yang dlaporkan tertelusur ke Setuan Penguikwan SI melalui LK-057.1DN draceaninty ‘TANGGAL DITERIMA TANGGAL KALIBRAST 26 Februari 2022 Dae of aecepiance 22 Keb. 2022 ‘Date af calibration KONDISLLINGKUNGANKALIBRASI: Suhu/Temp. Kelembaban ‘Environment conaiiuon of calioration ZC 66% LOKAS! KALIBRASI Laboratorium Kalibrasi - PT BKI Cabang Utama Komersil Balikpapan ‘Location of calrbranon METODA KALIBRASL Pressure Gauge ini dikalibrasi dengan menggunekanalat Standar Dead Weight Tester Calibration method éengan nomor seri CPBS80O, ketertulusuran ke SatuanInterasional (1) melahi Laboratorium Kalibrasi Global Quality Indonesia LK-0S7-IDN ‘Metode kerja yang digunakan sesusi dengan Prosedur Mutu Laboratorium Kalibrai PY Biro Kiasifkasi indonesia (Persero) No. : WILAB-S8 issued O& ACUAN BS/EN 837-1 : 1998, ISO/IEC Guide 98-3:2008, DKD-R 6-1:2014 Kejerence HASIL KALIBRASI DAN KETIDAKPASTIAN KALIBRAST (Teslampir) ‘Kesuit calibration and uncertainty oj calioranon (anacnea) (04 Maret 2022 Date of issue inn abortorian aoa PT Bo Kia! agonal (eres) SERTIFICAT isa itt bun anéetangen plat yng berwenang dan cp abortariam alas PT re Kailas done (ers) bki PT. BIRO KLASIFIKAS! INDONESIA (Persero) VKAN BALIKPAPAN COMMERCIAL MAIN BRANCH LMT Haryone No. Ring Read BAUKPAPAN ~76116 Lk.254:0N Phone: 462-542) 875582, 576643, ‘emai: bpe@iskicoid 's0/tEC 17025:2017 LAMPIRAN SERTIFIKAT KALIBRASI ~~ Attachment of calibration certificate Hal 22 Nomar 012-PG-LK254-BPC-22 Tanggel 04 Maret 2022 ‘umber Date 1. Hasil Kalibrasi ‘Result of Cattoranon Nilai Standar Penunjukan Alat Koreksi | Ketidakpastian (psi) (psi) (psi)__|/ Uncertainty *) Naik [Turan Naik Turun Up_| Down (psi) 0 0 0,00 0,00 0,00 | 0,00 400 400 400,95 400,95 0,95 0,95 800 800 800,95 800,95 0,95 0,95 1.200 1.200 1199.95, 1,199,95 -0,05 | -0,05 1.600 1,600 1601,95 1.601,95 1,95 1,95 2.000 | 2.000 2001,95 2.001,95 195 | 1,95 48 2300 | 2.300 2301,95 2.301,95 195 | 1,95 2.600 | 2.600 2601,95 2.601,95 195 | 1,95 3.000 | 3.000 2999.95 2.999,95 -0,05 | -0,05 3.300 3.300 3302,95, 3.302,95 2,95 2,95 3.00 | 3,600 3601,95 3.601,95 195 | 1,95 "Note: *) Ketidakpastian yang dilaporkan adalah ketidakpastian bentangan dengan tingkat kepercayaan 9596 dan faktor cakupan k=2 CERTIFICATE OF PERSONNEL & ACREDITATION CERTIFICATE OF LABORATORY 1201 40BEAC @ TUN, TUEVard TW we ested ners. ents eenton eins le ao CERTIFICATE This is to certify that Ardi Arianto has attended the training on Calibration Method at PT Biro Klasifikasi Indonesia The training covered the following subjects: Calibration Work Instruction of Test Gauge, Pressure Gauge, Ultrasonic Thickness, Hardness Tester Estimation of Uncertainty in Calibration Quality Assurance of Calibration Results Training Date : 2016 July 25 - 27 Certificate Registration No, 1303212504/01 fs (on behalf of TUV Rheinland Group Jakarta/indonesia, 2017 January 26 es aie ZX TOvrheiniand® Precisely Right.

You might also like