—Trescal I CALI@RATION SOLUTIONS TO IMPROVE YOUR PERFORMANCE | — Certificate of Calibration Reference No 523113402, Date of Issue 19 Sep 2028 ‘Customer BROMMA (Malaysia) SDN. BHD. Lot 18, Jalan Klebang 1/6 1D: 028214 Zon Perindustrian Bebas Kinta 131200 Ipoh Perak Instrument. Bevel Protractor ‘Model Mitutoyo Serial No 100892 Control No cya751 Equipment iD NA Capacity/Range 0° to 180° Date of Receipt ‘11 Sep 2023 Date of Calibration 19 Sop 2023, Recalibration Date 19 Sep 2025 (Specified by Customer) The User should be aware there are many factors may cause this Instrument to drift out ‘of calibration limits prior to the stated recalibration date. Condition of Instrument Bofore Calibration Item stained After Calibration Calibrated and Serviceable Location of Calibration _—_‘Trescal Laboratory Calibration Environment (20.0 + 1.0) °C, (85 + 15) %érh Calibration Method LOP 01432 Reference Standard Used | Reference Instrument Equipment ID © ControlNo —GertificateNo ‘Traceableto Due Date | Stel Square Prt-DP.sa2 ‘cesook—«PSYP-29000088 -—«NMIMINIST 10 Feb 2024 ‘angle Bloc PHOS-ABI caosses ——_PSYP-20011181 Nn 18 Feb 2024 | | Calibrated By ‘Approved Signatory Binti Satar 30 Hun Wel ‘Siti Fari ‘Tre reported exaeded measure: uncer stated 2s he Sarda messrment uncertain muted te coverage atau that e cove pabaiycvespands to apresinaely 9% This cetifcate is isued in accordance withthe laboratory accreditation requirements of Skim Akeditasi Makmal Malaysia (SAM) of Standards Malaysia which sa signatory tothe LAC HRA itprevides traceability of measurement tothe SI system of units and/or to units of measurement realised atthe National Metrology Intute of ‘Malaya (RMIM) and other recognises national metology Institutes. Copyright of his ciate is owned by tha ising laboratory and may not be reproduce athe than in ful except wih the prior written approval ofthe Head a the fssung laboratory. en ey ee ee ene Se eg ee ee (rescal “LIBRATION SOLUTIONS TO IMPROVE YOUR PERFORMANCE | - Certificate of Calibration Control No. CY2781 Cert. No. PSYP-23066427 Remark: (*) mean Out of Specification in 1. WUT: Unt Under Test: CW: Clockaise: CCW: Courterochvise 2. Tre Value =UUT Resting + Corecton 2 Unceainy Parameter, associate wth ho resut of measurement hat chracaes ihe persion of he vale that easoneby be sould tome measures “Page? of Instrument Calibrated Specification 25" ACCURACY TEST REFERENCE uuT ‘SPECIFICATION ‘ANGLE MEASURED VALUE | CORRECTION + Degree(°) | Minutes(') | Degree(°) | Minutes(') | Minutes (*) Minutes (*) 9 0 0 5 5 5 ° 5 ° o | 10 0 10 0 0 5 30 ° 29 55 5 80 ° 59 55 5 | 90 ° 89 85 5 CCW SOLUTION "| ACCURACYTEST REFERENCE uuT SPECIFICATION "ANGLE. __ MEASURED VALUE | CORRECTION | 8°" > Degree (*) | Minutes (*) | Degree (®) | Minutes(*)| Minutes (*) | Minutes (*) ° 0 0 8 6 5 o 5 o ° 10 ° 10 o ° 5 30 o 30 o ° 60 o 60 o 0 80 o 90 ° ° Measurement Uncertainty = 5! Oe k=2 | | | ‘he rooted enunded mesures uncer satad he standard easueen uncaring car sch hl the coverage prota cvespands to appanaty OK “This certifat is issued n accordance with the laboratory accrediation requirements of Skim Aedes Maka Malaysia (ANN) of Standards Malaysia which isa signatory "te the LAC MRA provides traceability of measurement to the Sl system of uns and/or to unt of measurement realised atthe Nationa Metrology Institue Walaysia (NIM) and other recognised national metrology institutes. Copyright ofthis certificate is anne by the issuing aboratry and may not be 1 reproduced other than in fll excot withthe plo written approval ofthe Hea ofthe Isuing aboratory. ee TY ee ec ene ee cet wo

You might also like