PERSPECTIVE VIEW
SCALE NTS
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3 1 2 3
10000
5800 4200
A A
5400
B B
DW
4600
16000
C C DN
6000
UP
D D
GROUND FLOOR PLAN SECOND FLOOR PLAN
SCALE NTS SCALE NTS
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR-1.0
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
1 2 3
A
A
B
B
C DN
C
D
D
FOUNDATION PLAN FRAMING PLAN
SCALE NTS SCALE
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 ST-1.0
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
ROOF FRAMING PLAN
SCALE NTS
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 ST
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
TRANSVERSE SECTION
SCALE NTS
NAME SCHOOL
UNIVERSITY OF RIZAL SYSTEM RCD
JOSE MIGUEL C. HAGOSOJOS PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043
AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
A B C D
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
LONGITUDINAL SECTION
SCALE NTS
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
FRONT SIDE VIEW
SCALE NTS
NAME SCHOOL
RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
MORONG,CAMPUS
PROFESSOR DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
3 2 1
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
REAR SIDE VIEW
SCALE NTS
NAME SCHOOL
UNIVERSITY OF RIZAL SYSTEM RCD
JOSE MIGUEL C. HAGOSOJOS PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043
AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
A B C D
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
LEFT SIDE VIEW
SCALE NTS
NAME SCHOOL
RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
D C B A
Level 4
7000
Level 3
6000
Level 2
3000
Level 1
0
foundation
-2500
RIGHT SIDE VIEW
SCALE NTS
NAME SCHOOL
RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
Level 4
7000
Level 3
6000
Level 2
3000 GRID A 1-3 FRAME ELEV
SCALE NTS
Level 1
0
foundation
-2500
1 2 3
Level 4
7000
Level 3
6000
Level 2
3000
GRID B 1-3 FRAME ELEV
SCALE NTS
Level 1
0
foundation
-2500
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 ST
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
1 2 3
Level 4
7000
Level 3
6000
Level 2 GRID C 1-3 FRAME ELEV
3000
SCALE NTS
Level 1
0
foundation
-2500
1 2 3
Level 4
7000
Level 3
6000
Level 2
3000
GRID D 1-3 FRAME ELEV
SCALE NTS
Level 1
0
foundation
-2500
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
MORONG,CAMPUS
PROFESSOR DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 ST
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
D C B A
Level 4
7000
Level 3
6000
GRID 1 A-D FRAME ELEV
SCALE NTS
Level 2
3000
Level 1
0
foundation
-2500
D C B A
Level 4
7000
Level 3
6000
Level 2
3000
GRID 2 A-D FRAME ELEV
SCALE NTS
Level 1
0
foundation
-2500
NAME SCHOOL RCD
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043 ST
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
D C B A
Level 4
7000
Level 3
6000
GRID 3 A-D FRAME ELEV
Level 2
3000 SCALE NTS
Level 1
0
foundation
-2500
NAME SCHOOL
UNIVERSITY OF RIZAL SYSTEM RCD
JOSE MIGUEL C. HAGOSOJOS PROPOSED 2-STOREY SCHOOL YEAR 2023-2024
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE STUDENT NUMBER M 2020-0043
ST
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN SECTION 4CE - A
CIVIL ENGINEERING
740 1500
2400
STEEL FRAME STEEL
MAHOGANY
WOOD MULLION
MAHOGANY
WOOD
GLASS GLASS
2200 2200 2000
900 500
WINDOW 1
DOOR 1 DOOR 2
400
3600 1200
STEEL
STEEL
MULLION
MULLION
GLASS
GLASS
2500 2000
2000
WINDOW 2 WINDOW 3 WINDOW 1
NAME SCHOOL
JOSE MIGUEL C. HAGOSOJOS UNIVERSITY OF RIZAL SYSTEM PROPOSED 2-STOREY
PROFESSOR
MORONG,CAMPUS
DEPARTMENT / COLLEGE AR
ENGR. JOHN JERBY YTANG COLLEGE OF ENGINEERING RESIDENTIAL HOUSE PLAN
CIVIL ENGINEERING