You are on page 1of 2

General GP3579

Polymers® Standard Epoxy


Floors

Primer/ Binder
Part A GP3579 Series
Part B GP3579B01 Standard Hardener

Revised 01/12

Product Description Product Characteristics


GP3579 STANDARD PRIMER / BINDER is a high solids, clear or Color: Clear, Red, Gray, White
pigmented epoxy primer and binder resin. GP3579 STANDARD
Mix Ratio: 2:1
PRIMER / BINDER is available in clear, red, white and gray, has
good blush resistance and is low in viscosity to promote penetration Volume Solids: 96% ± 2%, mixed
of the concrete substrate and excellent wetting of mortar aggregate. Weight Solids: 96% ± 2%, mixed

VOC (EPA Method 24): <50 g/L mixed: 0.41 lbs/gal

Viscosity, mixed: 2,100 cps


Advantages
• Good blush resistance at room temperature Recommended Spreading Rate per coat:
• Low modulus of elasticity, stress relieving Minimum Maximum
• Low VOC permitting installation during normal working hours Wet mils (microns): 6 (150) 20 (500)
• Penetrates and reinforces substrates ~Coverage sq ft/gal (m2/L): varies according to usage
• Acceptable for use in USDA inspected facilities
Drying Schedule @ 6 mils (150 microns) wet:
@ 73°F (23ºC)
Typical Uses
To touch: 6-8 hours
GP3579 STANDARD PRIMER / BINDER is a VOC (volatile or- To recoat: 10-20 hours
ganic content)compliant epoxy primer for coatings, slurries, mortar If maximum recoat time is exceeded, abrade surface before recoating.
overlays, and patches. It can be also used as a binder resin. For Drying time is temperature, humidity, and film thickness dependent.
slurries, mortar and patching systems. Pot Life: gallon mass 25-30 minutess @ 73°F (23ºC)
Shelf Life: Part A: 36 months, unopened
Part B (Standard): 36 months, unopened
Limitations
• Slab on grade requires vapor/moisture barrier. Store indoors at 50°F (10°C) to 90°F (32°C)
• Surface must be clean and dry. Flash Point: >230°F (>110°C), ASTM D 93, mixed
• Cool damp conditions may cause surface blushing.
• Substrate must be structurally sound and free
of bond inhibiting contaminants.
Performance Characteristics
• During installation and initial cure cycle substrate andambient Test Name Test Method Results
air temperature must be at a minimum of 50ºF (10ºC). Adhesion ACI 503R 300 psi
Substrate temperature must be least 5ºF (-15ºC) above the concrete failure
dew point (for lower temperature installation contact your local Compressive ASTM D 695 9,000 psi
representative. Strength
• When required, adequate ventilation shall be provided and Flammability Self-extinguishing
proper clothing and respirators worn. over concrete
• Strictly adhere to published coverage rates. Flexural Strength ASTM D 790 6,000 psi
Hardness, Shore D ASTM D 2240 75/65
Tensile Strength ASTM D 638 3,000 psi

Surface Preparation
Proper inspection and preparation of the substrate to receive
resinous material is critical. Read and follow the “Instructions for
Concrete Surface Preparation” (Form G-1) for complete details.

continued on back
General GP3579
y Polymers® Standard Epoxy
Floors

Primer/ Binder
s Part A GP3579 Series
Part B GP3579B01 Standard Hardener

Product Information
Application Cleanup
Clean up mixing and application equipment immediately after
• APPLICATION INSTRUCTIONS
use. Use toluene or xylene. Observe all fire and health precau-
1. Add 2 parts 3579A (resin) to 1 part 3579B (hardener) by volume. tions when handling or storing solvents.
Mix with low speed drill and Jiffy blade for three minutes and until
uniform. To insure proper system cure and performance, strictly
follow mix ratio recommendations. Safety
Refer to the MSDS sheet before use.
2. 3579 may be applied via spray, roller or brush. Apply evenly,
with no puddles. Coverage will vary depending upon porosity of Published technical data and instructions are subject to change
without notice. Contact your Sherwin-Williams representative
the substrate and surface texture. for additional technical data and instructions.
3. 3579 application varies upon usage.
Maintenance
NOTE: Epoxy materials may tend to blush at the surface especially
Occasional inspection of the installed material and spot repair
in humid environments. After the surface is primed and before can prolong system life. For specific information, Contact your
installation of each subsequent coat, surface must be examined Sherwin-Williams representative.
for blush (a whitish greasy film and/or low gloss). The blush must
be completely removed prior to recoating using warm detergent Shipping
water or through solvent wipe. • Destinations East of the Rocky Mountains are shipped F.O.B.
Cincinnati, Ohio.
Epoxy materials will appear to be cured and dry to touch prior
to full chemical cross linking. Allow epoxy to cure for 2-3 • Destinations West of the Rocky Mountains are shipped F.O.B.
days prior to exposure to water or other chemicals for best Victorville, California.
performance. For specific information relating to international shipments, contact
your local sales representative.

Ordering Information Disclaimer


The information and recommendations set forth in this Product Data Sheet are
Packaging: based upon tests conducted by or on behalf of The Sherwin-Williams Company.
Such information and recommendations set forth herein are subject to change and
Part A: 1 gallon (3.8L) and pertain to the product offered at the time of publication. Consult your Sherwin-
5 gallon (18.9L) containers Williams representative to obtain the most recent Product Data Information and
Part B: 1 gallon (3.8L) and Application Bulletin.
5 gallon (18.9L) containers
Warranty
Weight: 9.4 ± 0.2 lb/gal; 1.13 Kg/L The Sherwin-Williams Company warrants our products to be free of manufactur-
mixed, may vary by color ing defects in accord with applicable Sherwin-Williams quality control procedures.
Liability for products proven defective, if any, is limited to replacement of the defec-
tive product or the refund of the purchase price paid for the defective product as
determined by Sherwin-Williams. NO OTHER WARRANTY OR GUARANTEE
OF ANY KIND IS MADE BY SHERWIN-WILLIAMS, EXPRESSED OR IMPLIED,
STATUTORY, BY OPERATION OF LAW OR OTHERWISE, INCLUDING MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

www.sherwin-williams.com/protective

You might also like