The most popular method in the world for testing the hardness of metals using a portable
hardness tester is the Leeb method (ASTM A956).
The so-called dynamic method for determining hardness is widespread due to its ease of use.
The user does not need to have special skills and or knowledge in the field of hardness
measurement, to carry out the measurement, it is necessary to charge up the impact body of
the device’s probe, install the probe on the tested surface, press the release button of the
probe and the hardness value will be displayed on the device screen.
This method is recommended for large products, weighing from 5 kg and a thickness of 10 mm
and more, however, observing certain requirements for fixing the product, it is possible to
measure also small parts.
o D
o DC
o DL
Probe types o C
o D+15
o E
o G
o HRC:20~70
o HB:90~650
o HV:230~940
Measuring range for steel
o HLD:170~960
o Tensile strength, MPa: 370~1740
o User calibrations for any range (for example: HV100-1600)
o HRC: 2HRC
o HB: 10HB
Measuring accuracy
o HV: 15HV
o HLD: 4HLD
o ASTM A 956
o ASTM E 140
o ASTM A 370
o ISO 16859
Standards
o DIN 50156
o GB/T 17394
o JB/T 9378
o ISO 18265
o Temperature: -20°C~40°C
Operating environment
o Humidity: 30%~80%R.H.