6SL3210-1KE13-2UF1 Datasheet en
6SL3210-1KE13-2UF1 Datasheet en
Line voltage 380 ... 480 V +10 % -20 % Switching level: 0→1 11 V
Output Number 1
Rated voltage 400V IEC 480V NEC 1) Number as relay changeover contact 1
150 % base load current IL for 3 s, followed by 110 % base load current IL for 57 s PTC/ KTY interface
in a 300 s cycle time
1 motor temperature sensor input, sensors that can be connected PTC, KTY and
High Overload (HO) Thermo-Click, accuracy ±5 °C
200 % base load current IH for 3 s, followed by 150 % base load current IH for 57 Closed-loop control techniques
s in a 300 s cycle time
V/f linear / square-law / parameterizable Yes
General tech. specifications V/f with flux current control (FCC) Yes
Power factor λ 0.70 ... 0.85
V/f ECO linear / square-law Yes
Offset factor cos φ 0.95
Sensorless vector control Yes
Efficiency η 0.97
Vector control, with sensor No
Sound pressure level (1m) 52 dB
Encoderless torque control No
Power loss 46.1 W
Torque control, with encoder No
Filter class (integrated) Unfiltered
Communication
Communication PROFINET, EtherNet/IP
Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 1 of 2 Generated Thu Jan 25 15:36:09 CET 2024
Data sheet for SINAMICS G120C
Cooling air requirement 0.005 m³/s (0.177 ft³/s) Comparison with the reference
26.2 %
converter (90% / 100%)
Installation altitude 1,000 m (3,280.84 ft)
Ambient temperature
I 39.5 W (1.8 %) 42.5 W (2.0 %) 46.1 W (2.1 %)
Operation -10 ... 40 °C (14 ... 104 °F) 100%
Relative humidity
Connections
31.1 W (1.4 %) 31.8 W (1.5 %)
Signal cable 25%
Mechanical data
Degree of protection IP20 / UL open type
Dimensions
Standards
Compliance with standards UL, cUL, CE, C-Tick (RCM)
Technical data are subject to change! There may be discrepancies between calculated and rating plate values. Page 2 of 2 Generated Thu Jan 25 15:36:09 CET 2024