As per ISO 16810:2014, the following scannings are permitted
a Fully automated
b Semi-Automated
c Manual
d All of the above

2 What will be the best technique to catch a forging flake whose major dimension is parallel to the through thickness
dimension of a 50mm forging bar?
a Straight beam
b Pitch catch
c Through transmission
d Both b and c

3 As per ISO 16810:2014, how the signal amplitude is to be measured?


a Comparison with DGS Curve
b Comparison with TCG Curve
Echoes from SDH
Echoes from 25mm radius of V2 block

4
As per ISO 16810:2014, amplification settings
a Must be same during examination and evaluation
b Can be different during examination and evaluation
c Both
d None of the above

5 As per ISO 16810:2014, frequency and dimension of the transducer must be such that
a the near field length shall be smaller than the thickness of the object
b the near field length shall be larger than the thickness of the object
c the near field length shall equal the thickness of the object
d None of the above

6 As per ISO 16810:2014, examinations in normal cases utilises the following frequency ranges
a 10Mhz to 25 Mhz
b 0.5Mhz to 5Mhz
c 1Mhz to 10 Mhz
d None of the above

7 As per ISO 16810:2014, the choice of probe must take into account the dead zone in relation to the examination
volume. To cover the scanning zone of dead zone, the following scan plan may be used.
a Scanning from single side of the object
b Scanning from both side of the object
c Scanning perpendicular to the forging direction
d Using a probe with a lower Mhz frequency

8 As per ISO 16810:2014, the focussing probe is to be used for


a Detection of smaller defects
b Sizing of reflectors
c Both

1 of 3
d None of the above

9 As per ISO 16810:2014, when is it necessary to use transfer correction


a If the calibration and examination surfaces are same
b If the calibration and examination surfaces are different
c If the calibration is not performed
d None of the above

10 As per ISO 16810:2014, method of checking the stability of sensitivity is


a Using IIW V1 block
b Using IIW V2 block
c Using specific blocks with known defects.
d Using IOW blocks

11 As per ISO 16810:2014, when shall the filtering be used


a When sensitivity is less
b When resolution is less
c When damping is low
d None of the above

12 As per ISO 16810:2014, What are the following factors that needs to be considered while optimizing the scanning
speed.
a PRF
b Ability of the operator to recognise indications
c Ability of the UFD to record signals
d All of the above

13 As per DIN EN 10228-3:2016, While using a straight beam B4S probe on a rectangular bar of dimension
500mm(length) x 200mm(width) x 110mm(thickness), it is observed that an indication of a certain amplitude is
touching 3mm ERS of a constructed DGS curve. The indication as per quality class 4 is to be:
a Recorded
b Repaired
c Not Recorded
d None of the above

14 As per DIN EN 10228-3:2016, while inspecting a hollow ring forging of OD-254mm and ID-101.6mm , it is observed
that an indication of a certain amplitude is reading ERS value of 1.8mm of a constructed DGS curve with normal
beam probe. The indication as per quality class 4 is to be:
a Repaired
b Recorded
c Neither recorded not repaired
d None of the above

15 As per DIN EN 10228-3:2016, the ERS value to be used while recording isolated discontinuities as per quality class
2 is:
a Less than 5
b Greater than 5
c Equal to 5
d None of the above

16 Surface finish for Quality class 4 is to be maintained at 7.1µm as per DIN EN 10228-3:2016
a TRUE
b FALSE

17 As per procedure AFL/SP/06/13D Rev 02 an indication of size 1.2 is observed at 28mm from OD on an object having
OD of 355mm. The indication is
a Reject
b Register
c Record

2 of 3
18 As per procedure AFL/SP/06/13D Rev 02 an indication of size 0.6 is observed at 22mm from ID on an object having
OD of 402mm. The indication is
a Reject
b Register
c Record

19 As per Flender Specification TL-901 Rev 5 Quality class 4, Max allowable BWR attenuation in dB for QC 1 is
a 2
b 6
c 8
d 12

20 As per DIN EN 10228-3:2016, dual element probes are to be used for:


a Near Surface inspection
b Far Surface inspection
c Not needed
d None of the above
Prepared By: Debjyoti Sengupta Signature: