RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 1 28.09.2020 11:54:40


The ebm-papst RadiPac series
is now modernized
in. wg
Pa

2600
10

2400 Air performance range for RadiPac „High pressure“


400
355
2200

2000
8

560 630

1800

1600
6

1400

250
1200 Air performance range for RadiPac „Standard“

1000 280
4

800

600 560
2

400
630
450
200 355 400 1000
310 500 710 800
pfs

0 5000 10000 15000 20000 25000 cfm

qv 10000 20000 30000 40000 m³/h


Air performance range for RadiPac "Standard" 250 -1000 and RadiPac "High pressure" 355 - 630
The graph shows the maximum air performance for each size. If less performance is required, variants with smaller motors can be used.
This saves additional costs. The right fan for every application!

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 2 28.09.2020 11:54:43


EC centrifugal fans
RadiPac & RadiFit

the engineer’s choice


Page Page

Information 4 About ebm-papst / GreenIntelligence 4

Information

Information
A convincing concept with a wide range 6
of applications / FanScout
Product overview 12

RadiPac - Standard 20 EC centrifugal fans - RadiPac

250 - 1000 250 - 355 24

EC centrifugal fans - RadiPac / FanGrid


400 - 560 52

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


EC centrifugal fans - RadiPac
630 - 1000 86

RadiPac - Gastronomy 108 Gastronomy execution


400 - 500 400 - 500 112

RadiPac - High pressure 118 High pressure execution


355 - 630 355 - 630 122

RadiPac - ATEX 128 ATEX execution


400 - 630 400 - 630 130

RadiFit 138 RadiFit execution


250 - 400 250 - 400 142

Accesories 152 FlowGrid air inlet grill 154

Accesories

Accesories
Intake finger guard 155
Inlet rings 156
Vibration absorbers 160

Technology 162 Connection diagrams 164


Effects of installation space 178
Technology

Technology

Airflow determination 179


Technical parameters
& scope 180

Contacts 186 www.ebmpapst.com/contact 186


Contacts

Contacts

ebm-papst worldwide

EC centrifugal fans - RadiPac · Edition 2020-08 3

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 3 28.09.2020 11:54:43


About ebm-papst

ebm-papst is a leader in ventilation and drive engineering technology and a much sought-after engineering partner in many
Information

Information

industries. With around 20.000 different products, we have the perfect solution for practically every requirement. We have
placed the highest emphasis on economy and ecology for many years.
We believe the consistent further development of our highly-efficient GreenTech EC technology provides our customers
with the best opportunities for the future in industrial digitization. With GreenIntelligence, ebm-papst already offers in-
telligent networked complete solutions that are unique anywhere in the world today and that secure our customers a
decisive advantage.

Six reasons why we are your ideal partner:

Our systems expertise. Proximity to our customers.


Of course you always want the best solution for every pro- ebm-papst has 29 worldwide production facilities, inclu-
ject. To get it, you need to consider the ventilation and drive ding those in Germany, China, the USA, plus 48 sales of-
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

engineering aspects as a whole. fices with an extensive network of sales representatives.


And that is precisely what we do...with motor technology You always have a local contact who speaks your langua-
that sets standards, highly sophisticated electronics and ge and is familiar with your market.
aerodynamically optimized designs – all from a single sour-
ce and perfectly matched. Our quality standards.
These system solutions release unique synergies worldwide. Of course you can rely on the top qu ality of our pro-
What’s more: they save you a lot of work. Using them means ducts. After all, we employ an uncompromising quality
you can concentrate on your core business. management system at every stage of the process.
This is documented by our certification in accordance
ebm-papst’s spirit of invention. with the DIN EN ISO 9001 and DIN EN ISO 14001 interna-
In addition to offering a wide range of products, we are tional standards, and the TS declaration of conformity.
able to develop customized solutions for you at any time.
At our three German locations in Mulfingen, Landshut and Sustainability as a way of life.
St. Georgen, a diverse team of 600 engineers and technici- Assuming responsibility – for the environment, our em-
ans is ready to work to your specifications. ployees and society – is an integral part of our corporate
Just get in touch with us to discuss your latest project. philosophy. That is why we develop products designed for
maximum environmental compatibility and produce them
Our cutting-edge technology. using processes that preserve resources.
ebm-papst is not only a pioneer in developing highly effi- We support environmental awareness among our junior
cient EC technology. We were also quick to recognize the staff and are actively involved in sporting, cultural and
potential of digitalization. educational activities.
This means we are now able to provide solutions that com- All of which makes us a better partner.
Accesories

Accesories

bine maximum energy efficiency with all the advantages of


IoT and digital connectivity.
Technology

Technology
Contacts

Contacts

4 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 4 28.09.2020 11:54:44


GreenIntelligence
Making Engineers Happy

Why do our customers look so happy? Because when it co- With our comprehensive range of services, we accom-
mes to the Internet of Things and the digital transformation, pany you and your projects through every step in the pro-

Information

Information
we provide them with a clear competitive edge with Green- cess, from your application’s planning to its deployment.
Intelligence for intelligent control and interconnection of Make use of our experts’ product expertise to offer your
fans, drives and systems to make applications more power- customers new and advanced features. Or use our digital
ful, processes more efficient, businesses more successful and tools for optimal product selection. That will make your
their customers more satisfied. processes more efficient and get your products to market
faster.
For industrial ventilation technology, solutions are in
demand that ensure top performance and operational relia- Now you know why ebm-papst makes engineers happy.
bility in every situation. GreenIntelligence gives you robust
fan solutions with intelligent networking capabilities that
provide reliable performance data and extensive control and
monitoring functions. They ensure high levels of efficiency
and system availability while guaranteeing maximum

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


data security.

Pablo improves the


performance of his
ventilation systems
even when they are
Here is how much already in operation.
GreenIntelligence
there is in RadiPac:
– Monitoring of motor and ambient
temperature
– Precise setting of air flow and operating
Accesories

Accesories

points
– Automatic condition monitoring
– Fan as a sensor
Technology

Technology
Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 5

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 5 28.09.2020 11:54:45


A convincing concept
with a wide range of applications

Simple and safe.


The electronics and motor form a single unit, which not
RadiPac stands for ...
Information

Information

only saves space but also makes for simple installation.


For instance, integrated commutation and control electro-
Realistic performance figures, because performance
nics take the place of an external variable frequency drive.
data is always measured for the entire fan consisting
And, because the motor and the electronics are already
of high-performance impeller, GreenTech EC motor
perfectly coordinated in the motor system, there is no need
and control electronics.
for any additional electronic filters and shielded cables. An
external motor protection switch is not required either. To
Effective logistics, because a single RadiPac part
sum up: No expensive adjustment work on commissioning,
number covers all the components required for your
and no grounding and shielding necessary. That’s how easy
ventilation application – that’s „one-stop shopping“.
it is with plug & play.
Easy commissioning, because all the functions re-
quired for operation are already incorporated and co-
Compact design.
ordinated. Simply connect using plug & play: that's it.
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

The high-performance impeller is mounted directly on


the rotor of the external rotor motor. This saves space and
Incidentally, the term RadiPac is made up of the
allows the entire rotating unit to be balanced in a single
German term „Radialventilator“, meaning centri-
clamping operation.
fugal fan, and the word „package“, meaning a
unit: it’s a ready-to-integrate, perfectly coordina-
ted, complete package that is easy to install.
Consistent series.
The fans completely cover all nominal sizes from 250 to
1000 and are available quickly. Sizes 250 and 280 are equip-
ped with impellers made of high-quality composite mate-
rial, manufactured in the injection molding process. Sizes
310 to 1000 have a high-efficiency aluminum impeller with
airfoil blades. The entire series was designed for maximum
efficiency with a low noise level at the same time. Sustain-
able production and resource conservation was also given
high importance. This is where the highly efficient Green-
Tech EC motor without rare earth magnets comes from.
Accesories

Accesories
Technology

Technology
Contacts

Contacts

6 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 6 28.09.2020 11:54:45


Design variants

Information

Information
Motor impellers are available in sizes 250 to 560 in all
impeller/motor combinations.
In addition to an inlet ring, an appropriately dimensi-
oned motor mount must be provided on site to operate
a motor-impeller.

RadiPacs with a support bracket are also available in


sizes 250 to 560 in all impeller/motor combinations as
ready-to-install support struts for wall mounting.

In sizes 630 to 800, these versions are only available in

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


combination with the lightweight size 150 motor.
The support bracket design includes the motor-impel-
ler, a welded support strut design, an inlet ring and a
square mounting plate.

RadiPacs with a cube design with impeller diameters


630 to 1000 and the „large“ size 200 motor are only
available in the cube design intended for floor moun-
ting.
The struts are extruded aluminum profiles, the corner
joints are made of die-cast aluminum, and the motor
mounting plate, inlet ring and nozzle plate are made
of galvanized sheet steel.
This version is not suitable for wall mounting. Accesories

Accesories

FanGrid modules are RadiPac centrifugal fans with


a support bracket in a special cube design.

The pre-assembled units in sizes 400 to 560 were


designed for setting up the „FanGrids“.
Technology

Technology

They are suitable for applications with very high


volumes of air that cannot be achieved by a single
fan with the required compact design.
Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 7

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 7 28.09.2020 11:54:50


Additional functions and special designs
Information

Information

RadiPac with resonance detection: FanGrid design kit:


Longer service life thanks to condition monitoring. modular solutions for high air performance levels.
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

Increased functionality: To achieve high air performance in ventilation technology,


– Simple status monitoring and vibration analysis instead of large individual fans, we are increasingly relying
– Test start-up during commissioning, including reso- on small fans operated in parallel in „FanGrids“. This type
nance point detection of arrangement is very flexible and efficient. What’s more,
– Suggestion for suppression of critical speed ranges the redundancy ensures a high level of operational reliabili-
ty; if one fan fails, the other fans compensate for the mis-
Intuitive operation: sing air quantity. The GreenTech EC fans offered by ebm-
– Full control over all settings and activities papst also help to significantly reduce operating costs.
– Hardware and software from a single supplier
Another advantage is that the air flows more evenly
Longer service life and lower maintenance costs: through upstream – and especially downstream – compo-
– High vibration ranges are automatically avoided nents such as filters and heat exchangers. This results in
– Warning in case of permanent imbalance more efficient air filtering and improved heat transfer per-
formance. Several small fans also require less space and are
RadiPac centrifugal fans with condition monitoring are lighter than a single large fan. This reduces the cost of the
available in selected sizes 400 to 560, including support system and makes replacing the fans simple.
bracket. Thanks to their perfectly integrated system and
plug & play, installation is very simple, so is the digital An important factor that tends to be overlooked in practice
connection for using the functions described with the is the risk of installation losses. If fans are installed too clo-
EC-Control control software. Even integration into exis- sely together, they tend to influence one another. The rule
ting building management systems is child’s play thanks of thumb is that the greater the volume of air that the fan
Accesories

Accesories

to the MODBUS RTU interface. has to convey, the further apart the fans should be. The di-
mensions of the FanGrid module with cube design are very
generous and large enough to prevent installation losses.
Technology

Technology
Contacts

Contacts

8 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 8 28.09.2020 11:55:01


Information

Information
RadiPac for restaurants and process exhaust air: RadiPac with high static pressure:
clean air according to standards. Ventilate buildings efficiently.

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


When preparing food in commercial kitchens, the ambient Air-handling units for large buildings like airports, sky-
air is severely contaminated, e.g. due to grease compo- scrapers or hotels face a special challenge: since residen-
nents and combustion gases, as well as heat and moisture. tial and commercial real estate are becoming increasingly
As a result, the air quality quickly has a questionable level expensive, centralized and space-saving solutions are
of hygiene, even in areas where the food is being handed generally preferred. This means that the air has to travel
out and across the entire dining room, without mentio- long distances through external pressure elements and
ning the unpleasant odors it creates. Legislation therefore through long air ducts to reach its destination. It becomes
requires AHUs to be installed. They extract foreign subs- even more problematic if it has to flow through additional
tances, moisture and odors from the air and bring in cool, „obstacles“, such as activated carbon filters, heat exchan-
clean air from outside. gers or separators (internal pressure losses). Fans with an
especially high static pressure increase are needed for all
Optimized for kitchen exhaust air. of these cases, and they need to be compact, efficient and
In contrast to the normal RadiPac, the motor and control reliable.
electronics have been removed from the contaminated
air flow in this special design in accordance with VDI 2052 (Air) resistance is futile.
and EN 1682, effectively preventing a layer of grease or oil To provide a reliable solution for AHU customers looking
from building up. Furthermore, the motor and controls are to ventilate and air-condition large buildings, ebm-papst
designed according to EN 60335-1 (Household and similar has improved its popular RadiPac product range to meet
electrical appliances – Safety). This standard must also be their special requirements. The result is high-performance
satisfied in the commercial sector if the devices are opera- centrifugal fans with a static pressure increase of up to
ted by non-experts and can therefore become a source of 2500 Pa, i.e. 15000 m³/h, and is available in sizes 355, 400,
Accesories

Accesories

danger. 560 and 630.

Optimum cooling included. Of course the new fans offer you the series’ many other
Thanks to the underpressure upstream of the fan com- advantages, including its high reliability, energy-efficiency
pared to the surroundings, cool ambient air is drawn in and compactness. And the rugged cube design is available
Technology

Technology

through a hose to cool the encapsulated motor. as an option again. Just install, connect with plug & play,
This means that the fan and the control system achieve and „turn up the pressure“.
their full output and high flow medium temperatures can
be allowed at a corresponding cooling air temperature.
Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 9

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 9 28.09.2020 11:55:07


Other variants

RadiPac with active PFC. RadiFit EC centrifugal fans:


Sizes 450, 500 and 560 are also available with the 3kW compact, efficient, easy to retrofit.
Information

Information

EC motor for three-phase supply networks with integrated


active PFC. With these products, we can now fulfill the Our RadiFit centrifugal fans with scroll housing and back-
increasingly frequent requests for total harmonic distortion ward-curved blades is the ideal system solution for a wide
of no more than 5 % (THDi ≤ 5 %). range of industrial and ventilation technology applications.
With their highly efficient GreenTech EC motors, they can
RadiPac with new 112 and 150 motors. offer excellent efficiency at high pressures. They are light,
Sizes 310 to 800 have been equipped with 112 and 150 EC robust and have the same installation dimensions as the
motors with 4 kW control electronics from the third industry standard. So installation and replacement are
Generation (Gen. III). These variants have been optimized child's play.
for high power density and minimal installation space.
Typical air conditioning and industrial applications:
RadiPac with increased corrosion protection.
The ready-to-install centrifugal fans are also available Low-profile air conditioners are used in air conditioned
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

in sizes 250 to 800 with additional corrosion protection buildings to temper the supply air using the warm exhaust
measures. This applies to both the centrifugal module with air. For this purpose, fans convey the air through the heat
support bracket and the cube design. In these versions, all exchanger and then through the inlet and exhaust air
metal surfaces have an additional coating. The color used ducts. Our RadiFit is compact, can be adjusted flexibly and
is black. is highly efficient, so it satisfies strict energy conservation
regulations.
RadiPac with reversed nozzle plate.
Centrifugal fans with a support bracket are available in In central air-conditioning units, the air must be trans-
sizes 310 to 560 in an additional mechanical design with a ported through various components such as filters, heat
reversed nozzle plate. exchangers, humidifiers and branched duct systems. The
fans have to compensate for the high pressure losses. The
In the standard version, the system should also save as much space as possible and per-
circumferential chamfer on mit simple, demand-based ventilation for a large number
the mounting plate faces up- of rooms. No problem for the RadiFit.
stream.
In the reversed version, the For cooling generators, a fan forces the ambient air
chamfer points downstream. through narrow ducts on the generator to cool it. The
RadiFit’s integrated speed control means that cooling can
ATEX fans. always be adapted to the load or heat generation. The fan
ebm-papst offers specially protected RadiPacs for use in requires very little space, as no separate control unit is
potentially explosive atmospheres available in sizes 400 to required. And it's maintenance-free too!
630. It is unique for a highly efficient EC motor with integ-
Accesories

Accesories

rated control electronics to also be suitable for use in po-


tentially explosive atmospheres of zones 1 and 2, making it
easier to use fans in the environment mentioned.
Technology

Technology
Contacts

Contacts

10 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 10 28.09.2020 11:55:08


ebm-papst FanScout:
click your way to the optimum RadiPac

Our axial fans can be configured individually for each appli- al measurements and the data calculated using the soft-
cation, and it is important to correctly consider all the rele- ware and assigned the accuracy of the calculation to the

Information

Information
vant aspects when selecting your axial fan. When making highest class.
your selection, you can rely on our experts' many years of
experience, and on our professional fan selection software Exact presentation of the life cycle costs:
as well: The costs of operation, acquisition, installation and service
can be calculated for a defined period of time.
With its outstanding user-friendliness and real measured A practical advantage:
values, the ebm-papst FanScout has more than proven its The software can be easily integrated into your device
worth already. It not only measures the performance of the configuration program using the DLL interface.
individual fan components but also that of the fan as a
complete system. The program allows you to quickly select The best part:
the best fan for your application, to describe and modify ebm-papst pre-selects the products that are suitable for
the operating behavior and to document the technical spe- you. This saves you the trouble of searching through the
cifications. Factors such as air performance, operating time broad product portfolio and helps you configure your appli-

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


and installation space can be taken into account in this pro- cation in advance.
cess. TÜV SÜD has tested the difference between the actu-

Accesories

Accesories
Technology

Technology

Would you like to find out more?


All products from this catalog are collated into a collection in FanScout. We will be pleased to provide you with this collection
on request. Or perhaps you have another question? Then get in touch with us for more information:
Contacts

Contacts

Ralf Mühleck, Tel. +49 7938 81-7035, Ralf.Muehleck@de.ebmpapst.com


or follow us at www.ebmpapst.com/radipac

EC centrifugal fans - RadiPac · Edition 2020-08 11

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 11 28.09.2020 11:55:09


EC centrifugal fans & modules
"RadiPac - Standard" 250 - 450

EC centrifugal fans - RadiPac (backward curved, Standard)


Information

Information

Nominal Max. Centrifugal Centrifugal


voltage input Centrifugal fan module with module with
range power support bracket cube design on
Size VAC W Page
Type Part number Type Part number Type Part number

1~200-277 500 VBS0250PSPGS R3G250PR04H1 VBH0250PSPGS K3G250PR04H2 --- ---

250 1~200-277 750 VBS0250PSPGS R3G250PR17I1 VBH0250PSPGS K3G250PR17I2 --- --- 24


3~380-480 1180 VBS0250PTPGS R3G250PR02J1 VBH0250PTPGS K3G250PR02J2 --- ---

1~200-277 500 VBS0280PSPGS R3G280PR03H1 VBH0280PSPGS K3G280PR03H2 --- ---

280 1~200-277 750 VBS0280PSPGS R3G280PR04I1 VBH0280PSPGS K3G280PR04I2 --- --- 30


3~380-480 1050 VBS0280PTPKS R3G280PS10J1 VBH0280PTPKS K3G280PS10J2 --- ---
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

1~200-277 1500 VBS0310PSRHS R3G310PG5721 VBH0310PSRHS K3G310PG5728 --- ---

1~200-277 1500 VBS0310PSRHS R3G310PG9321 VBH0310PSRHS K3G310PG9321 --- ---

3~380-480 1230 VBS0310PTPMS R3G310PT08J1 VBH0310PTPMS K3G310PT08J2 --- ---


310 36
3~380-480 1370 VBS0310PTPMS R3G310PT10W1 VBH0310PTPMS K3G310PT10W1 --- ---

3~380-480 3050 VBS0310PTRLS R3G310PV6903 VBH0310PTRLS K3G310PV6903 --- ---

3~380-480 3000 VBS0310PTRLS R3G310PV6902 --- --- --- ---

1~200-277 1500 VBS0355PSRLS R3G355PH3821 VBH0355PSRLS K3G355PH3822 --- ---

1~200-277 1500 VBS0355PSHRS R3G355PG5421 VBK0355PSHRS K3G355PG5422 --- ---

355 3~380-480 1300 VBS0355PTPMS R3G355PT12W1 VBH0355PTPMS K3G355PT12W1 --- --- 44


3~380-480 2900 VBS0355PTRLS R3G355PV7001 VBH0355PTRLS K3G355PV7001 --- ---

3~380-480 2900 VBS0355PTRLS R3G355PV7002 --- --- --- ---

3~380-480 3400 VBS0400PTRNS R3G400PW0301 VBK0400PTRNS K3G400PW0301 --- ---

3~380-480 3650 VBS0400PTTLS R3G400PA2702 --- --- --- ---


400 52
3~380-480 3650 VBS0400PTTLS R3G400PA2703 VBH0400PTTLS K3G400PA2703 VBH0400PTTLS K3G400PA27W4

3~380-480 3650 VBS0400PTTLS 1) R3G400PA2765 1) --- --- VBH0400PTTLS 1) K3G400PA27W5 1)


Accesories

Accesories

3~380-480 2650 VBS0450PTRNS R3G450PW1202 --- --- --- ---

3~380-480 2650 VBS0450PTRNS R3G450PW1201 VBH0450PTRNS K3G450PW1201 --- ---

3~380-480 3190 VBS0450PTTLS 2) R3G450PA21C1 2) VBH0450PTTLS 2) K3G450PA21C1 2) --- ---


Technology

Technology

450 3~380-480 4450 VBS0450PTTLS R3G450PA3102 --- --- --- --- 58


3~380-480 4450 VBS0450PTTLS R3G450PA3103 VBH0450PTTLS K3G450PA3103 VBH0450PTTLS K3G450PA31W3

3~380-480 4450 VBS0450PTTLS 1) R3G450PA3165 1) --- --- VBH0450PTTLS 1) K3G450PA31W5 1)

3~380-480 5250 VBS0450PTTPS R3G450PB2401 VBH0450PTTPS K3G450PB2401 --- ---


Contacts

Contacts

1) Centrifugal fan & FanGrid with resonance sensor 2) With active PFC

12 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 12 28.09.2020 11:55:14


EC centrifugal fans & modules
"RadiPac - Standard" 500 - 1000

EC centrifugal fans - RadiPac (backward curved, Standard)

Information

Information
Nominal Max. Centrifugal Centrifugal
voltage input Centrifugal fan module with module with
range power support bracket cube design on
Size VAC W Page
Type Part number Type Part number Type Part number

3~380-480 2350 VBS0500PTRNS R3G500PW0901 VBH0500PTRNS K3G500PW0901 --- ---

3~380-480 3100 VBS0500PTTLS 2) R3G500PA26C1 2) VBH0500PTTLS 2) K3G500PA26C1 2) --- ---

3~380-480 3350 VBS0500PTTLS R3G500PA2803 VBH0500PTTLS K3G500PA2803 --- ---

500 3~380-480 3900 VBS0500PTTPS R3G500PB2402 --- --- --- --- 68


3~380-480 3900 VBS0500PTTPS R3G500PB2403 VBH0500PTTPS K3G500PB2403 VBH0500PTTPS K3G500PB24W3

3~380-480 3900 VBS0500PTTPS 1) R3G500PB2465 1) --- --- VBH0500PTTPS 1) K3G500PB24W5 1)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


3~380-480 5700 VBS0500PTTPS R3G500PB3301 VBH0500PTTPS K3G500PB3301 --- ---

3~380-480 3060 VBS0560PTTPS 2) R3G560PB22C1 2) VBH0560PTTPS 2) K3G560PB22C1 2) --- ---

3~380-480 4400 VBS0560PTTPS R3G560PB3102 --- --- --- ---

560 3~380-480 4250 VBS0560PTTPS R3G560PB3103 VBH0560PTTPS K3G560PB3103 VBH0560PTTPS K3G560PB31W3 78


3~380-480 4250 VBS0560PTTPS 1) R3G560PB3165 1) --- --- VBH0560PTTPS 1) K3G560PB31W5 1)

3~380-480 5000 VBS0560PTTRS R3G560PC0401 VBH0560PTTRS K3G560PC0401 --- ---

3~380-480 4250
???? VBS0630PTTRS R3G630PC0803 VBH0630PTTRS K3G630PC0803 --- ---

630 3~380-480 7060


???? --- --- --- --- VBF0630PTVNS K3G630PV0401 86
3~380-480 9780
???? --- --- --- --- VBF0630PTVQS K3G630PW0401

3~380-480 3750
???? VBS0630PTTRS
VBS0710PTTRS R3G630PC0803
R3G710PC0503 VBH0710PTTRS K3G710PC0503 --- ---

710 3~380-480 7050


???? --- --- --- --- VBF0710PTVQS K3G710PV0501 92
3~380-480 11450
???? --- --- --- --- VBF0710PTVTS K3G710PW0601

3~380-480 2800
???? VBS0630PTTRS
VBS0800PTTRS R3G630PC0803
R3G800PC0203 VBH0800PTTRS K3G800PC0203 --- ---

800 3~380-480 7950


???? --- --- --- --- VBF0800PTVTS K3K800PV1301 98
3~380-480 11300
???? --- --- --- --- VBT0800PTVTS K3G800PW0701
Accesories

Accesories

1000 3~380-480 6340


???? VBS0630PTTRS
--- R3G630PC0803
--- --- --- VBF1000PTVTS
--- K3GA00PV0301
--- 104
1) Centrifugal fan & FanGrid with resonance sensor 2) With active PFC
Technology

Technology

Subject to technical changes.


Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 13

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 13 28.09.2020 11:55:15


EC centrifugal modules "RadiPac - Standard"
with support bracket & reversed nozzle plate 310 - 800
with support bracket & improved corrosion protection 250 - 560

EC centrifugal fans - RadiPac (with reversed nozzle plate / improved corrosion protection)
Information

Information

Nominal Max. Centrifugal module with Centrifugal module with


voltage input support bracket and support bracket and impro-
range power reversed nozzle plate ved corrosion protection
Size VAC W
Type Part number Type Part number

1~200-277 500 --- --- VBH0250PSPGS K3G250PR04H3

250 1~200-277 750 --- --- VBH0250PSPGS K3G250PR17I3

3~380-480 1180 --- --- VBH0250PTPGS K3G250PR02J3

1~200-277 500 --- --- VBH0280PSPGS K3G280PR03H3

280 1~200-277 750 --- --- VBH0280PSPGS K3G280PR04I3

3~380-480 1050 --- --- VBH0280PTPKS K3G280PS10J3


EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

1~200-277 1500 VBH0310PSRHZ K3G310PG5726 --- ---

1~200-277 1500 VBH0310PSRHS K3G310PG9327 --- ---

310 3~380-480 1230 VBH0310PTPMS K3G310PT08J4 VBH0310PTPMS K3G310PT08J3

3~380-480 1370 VBH0310PTPMS K3G310PT10W2 --- ---

3~380-480 3050 VBH0310PTRLS K3G310PV6905 --- ---

1~200-277 1500 VBK0355PSRLS K3G355PH3825 --- ---

1~200-277 1500 VBH0355PSRHS K3G355PG5426 --- ---


355
3~380-480 1300 VBH0355PTPMS K3G355PT12W2 --- ---

3~380-480 2900 VBH0355PTRLS K3G355PV7005 --- ---

3~380-480 2700 VBK0400PTRNS K3G400PW0305 --- ---

400 3~380-480 3650 VBH0400PTTLS K3G400PA2762 VBH0400PTTLS K3G400PA2733

3~380-480 3650 VBH0400PTTLS 1) K3G400PA2765 1) --- ---

3~380-480 2650 VBH0450PTRNS K3G450PW1205 --- ---

450 3~380-480 4450 VBH0450PTTLS K3G450PA3161 VBH0450PTTLS K3G450PA3133

3~380-480 4450 VBH0450PTTLS 1) K3G450PA3165 1) --- ---


Accesories

Accesories

3~380-480 2350 VBH0500PTTRNS K3K500PW0905 --- ---

3~380-480 3350 VBH0500PTTLS K3G500PA2805 --- ---

500 3~380-480 3900 VBH0500PTTPS K3K500PB2461 VBH0500PTTPS K3G500PB2433


Technology

Technology

3~380-480 3900 VBH0500PTTPS 1) K3K500PB2465 1) --- ---

3~380-480 5700 VBH0500PTTPS K3G500PB3305 VBH0500PTTPS K3G500PB3331

3~380-480 4250 VBH0560PTTPS K3G560PB3161 VBH0560PTTPS K3G560PB3133

560 3~380-480 4250 VBH0560PTTPS 1) K3G560PB3165 1) --- ---


Contacts

Contacts

3~380-480 5000 VBH0560PTTRS K3G560PC0405 VBH0560PTTRS K3G560PC0431


1) Centrifugal module with resonance sensor

14 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 14 28.09.2020 11:55:18


EC centrifugal fans - RadiPac (with reversed nozzle plate / improved corrosion protection)

Information

Information
Nominal Max. Centrifugal module with Centrifugal module with
voltage input support bracket and support bracket and impro-
range power reversed nozzle plate ved corrosion protection
Size VAC W
Type Part number Type Part number

630 3~380-480 4250 VBH0630PTTRS K3G630PC0804 --- ---

710 3~380-480 3750 VBH0710PTTRS K3G710PC0505 --- ---

800 3~380-480 2800 VBH0800PTTRS K3G800PC0205 --- ---

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories

Accesories
Technology

Technology

Subject to technical changes.


Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 15

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 15 28.09.2020 11:55:18


EC centrifugal modules "RadiPac - Standard"
with support bracket, reversed nozzle plate & improved
corrosion protection 400 - 560
with cube design & improved corrosion protection 630 - 800

EC centrifugal fans - RadiPac (with reversed nozzle plate / improved corrosion protection)
Information

Information

Centrifugal module with


Nominal Max. Centrifugal module with
support bracket, reversed
voltage input cube design & improved
nozzle plate and improved
range power corrosion protection
corrosion protection
Size VAC W
Type Part number Type Part number

400 3~380-480 3650 VBH0400PTTLS K3G400PA2734 --- ---

450 3~380-480 4450 VBH0450PTTLS K3G450PA3134 --- ---

500 3~380-480 3900 VBH0500PTTPS K3G500PB2434 --- ---

560 3~380-480 4400 VBH0560PTTPS K3G560PB3134 --- ---

3~380-480 7060 --- --- VBF0630PTVNS K3G630PV0402


630
3~380-480 9780 --- --- VBF0630PTVQS K3G630PW0402
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08

3~380-480 7050 --- --- VBF0710PTVTS K3G710PV0502


710
3~380-480 11450 --- --- VBF0710PTVTS K3G710PW0602

3~380-480 7950 --- --- VBF0800PTVTS K3G800PV1302


800
3~380-480 11300 --- --- VBF0800PTVTS K3G800PW0702
Accesories

Accesories
Technology

Technology

Subject to technical changes.


Contacts

Contacts

16 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 16 28.09.2020 11:55:20


EC centrifugal modules "Gastronomy & High pressure"
with cube design - Gastronomy 400 - 500
with support bracket - High pressure 355 - 400
with cube design - High pressure 560 - 630

EC centrifugal fans - RadiPac (for the food service sector and process exhaust air)

Information

Information
Nominal Max.
voltage input Centrifugal module with cube design
range power on
Size VAC W Page
Type Part number

400 3~380-480 3000 VBH0400NTTLS K3G400AQ27K1

450 3~380-480 2780 VBH0450NTTLS K3G450AQ23K1 112


500 3~380-480 3000 VBH0500NTTLS K3G500AP28K1

EC centrifugal fans - RadiPac (High pressure execution)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Nominal Max. Centrifugal module with Centrifugal module
voltage input support bracket with cube design
range power on
Size VAC W Page
Type Part number Type Part number

355 3~380-480 4700 VBH00355NTTLS K3G355HA3401 --- ---

400 3~380-480 6000 VBH0400NTTPS K3G400HB4101 --- ---


122
560 3~380-480 12000 --- --- VBF0560NTVQS K3G560HE0701

630 3~380-480 13750 --- --- VBF0630NTVTS K3G630AT0911

Accesories

Accesories
Technology

Technology

Subject to technical changes.


Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 17

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 17 28.09.2020 11:55:21


EC centrifugal modules "RadiPac - ATEX"
with cube design - ATEX 400 - 630

EC centrifugal fans - RadiPac (backward curved, ATEX execution)


Information

Information

Nominal Max.
voltage input Centrifugal module with cube design
range power on
Size VAC W Page
Type Part number

400 3~380-480 2100 VBF0400NTTLS K3G400AQ2390

450 3~380-480 2950 VBF0450NTTLS K3G450AQ2490

500 3~380-480 2970 VBF0500NTTLS K3G500AP2590 130


560 3~380-480 2940 VBF0560NTTPS K3G560AP2390

630 3~380-480 2970 VBF0630NTTRS K3G630AP0190


EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories

Accesories
Technology

Technology

Subject to technical changes.


Contacts

Contacts

18 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 18 28.09.2020 11:55:22


EC centrifugal modules "RadiPac - RadiFit"
with housing - RadiFit - 250 - 400

EC centrifugal fans - RadiFit (backward curved, with housing)

Information

Information
Nominal Max. Centrifugal fan - RadiFit
voltage input with housing
range power on
Size VAC W Page
Type Part number

250 3~380-480 1810 VCD0250FTPMS 1) D3G250GG0901 1)

280 3~380-480 1320 VCD0280FTPMS 1) D3G280GG1001 1)

3~380-480 3180 VCD0310FTRNS 1) D3G310GG0501 1)


310
3~380-480 3180 VCD0310FTRNS 2) D3G310GG0504 2)
142
3~380-480 3160 VCD0355FTRNS 1) D3G355GG0301 1)
355
3~380-480 3160 VCD0355FTRNS 2) D3G355GG0304 2)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


3~380-480 2380 VCD0400FTRNS 1) D3G400GG0401 1)
400
3~380-480 2380 VCD0400FTRNS 2) D3G400GG0404 2)
1) RadiFit with mounting bracket 2) RadiFit with mounting frame

Accesories

Accesories
Technology

Technology

Subject to technical changes.


Contacts

Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 19

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 19 28.09.2020 11:55:22


RadiPac - Standard:

Type R3G... RadiPac motor impellers are available in sizes 250 to 560 for all impeller/motor combinations. For sizes 630 to 800,
these versions are only available in combination with the lightweight size 150 motor. Operation of a type R3G... motor impeller
requires an inlet ring and a motor mounting of suitable dimensions to be provided by the customer.

Type K3G... centrifugal fans are also


available in sizes 250 to 560 and for
all impeller/motor combinations in
a ready-toinstall design with sup-
port struts for wall mounting.
For sizes 630 to 800, these versions
are only available in combination
with the lightweight size 150 motor.
The K3G "spider" design includes
the motor impeller, a welded sup-
port strut assembly, an inlet ring
and a square mounting plate.

Type K3G... centrifugal fans with


impeller diameters 630 to 1000 and
the "large" size 200 motor are only
available in the cube design inten-
ded for floor mounting.
The struts are extruded aluminum
profile, the corner joints are made
of die-cast aluminum, and the
motor mounting plate, the inlet
ring and the nozzle plate are made
of galvanized sheet steel.
This version is not suitable for wall
mounting.

Type K3G (cube for FanGrid) cen-


trifugal fans in sizes 400 to 560 are
designed as pre-assembled units
for creating so-called FanGrids.
These units are suitable for applica-
tions with very high volumes of air
that cannot be achieved by a single
fan with the required compact
design. For installation, we recom-
mend the stainless steel mounting
elements available as accessories.

20 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 20 28.09.2020 11:55:25


RadiPac 250 - 1000
Standard

the engineer’s choice


Page

Tender specification 22

Information
250 24

280 30

310 36

355 44

400 52

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


450 58

500 68

560 78

630 86

710 92

800 98

1000 104

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 21

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 21 28.09.2020 11:55:26


Tender specification
EC centrifugal fans - RadiPac "Standard"
Fan size 250 to 1000

Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics.

Impeller made of aluminum, with 5 backwards-curved, con- connected to die-cast corner plates, nozzle plate and inlet
tinuously welded, hollow-profile blades; impeller sizes 250 ring made of sendzimir galvanized sheet steel, motor
and 280 made of plastic; flow-optimized inlet ring made of mounting plate made of coated sheet steel. This version is
galvanized sheet steel with pressure test nipple. not suitable for wall mounting.

Motor impeller statically and dynamically balanced on two Any work required for isolation from structure-borne noise
planes to balancing grade G 6.3 (motor size 200 to balan- to be performed by the customer. Fan satisfies the applica-
cing grade G 4.0) in accordance with DIN ISO 21940. ble EMC guidelines and requirements with regard to circuit
EC centrifugal fans - RadiPac · Edition 2020-08

feedback (for specific information, see the respective data


GreenTech EC external rotor motor surpasses efficiency
sheet). Documentation and marking conform to the appli-
class IE4, magnets with no rare earths, maintenance-free
cable EU Directives.
ball bearings with long-term lubrication, theoretical nomi-
nal service life of at least 40.000 hours of operation. Reliable performance data, air performance measurements
on intake-side chamber test rig according to ISO 5801 and
Soft start, integrated current limitation, extended voltage
DIN 24163, noise measurements in anechoic rooms accor-
input 1~200-277 V, 50/60 respectively 3~380-480 V, 50/60
ding to DIN EN ISO 3745.
Hz. Fan can be used with all standard power supply net-
works with unaltered air performance. Integrated electro- Integrated protective devices:
nics, low-noise commutation logic; 100 % open-loop speed - Alarm relay with zero-potential change-over contacts
control; all fans have an RS485/MODBUS RTU interface, (250 V AC/2 A, cos w = 1)
and do not need to be installed with shielded cables. - Locked-rotor protection
All 1~ types have an integrated active PFC (Power Factor - Phase failure detection
Correction) to reduce disturbing harmonic content. - Soft start of motors
Terminal box made of aluminum/plastic with easily acces- - Mains under-voltage detection
sible connection area with spring-loaded terminals, en- - Thermal overload protection for electronics and motor
vironment-resistant cable glands, or with external variable - Short circuit protection
cable (sizes 250 to 280).
Optional:
Version for wall mounting: - Other and specific requirements on request
Support bracket, sizes 250 to 560 and 630 to 800 with size - FlowGrid air inlet grill:
150 motor as ready-to-install support bracket intended for FlowGrid air inlet grill tailor-made for the fan, to re-
wall mounting. Support bracket made of bent round bar duce assembly and system-related noise. Grill made of
steel or round tube, welded and coated in black. Mounting high-grade composite material in one piece, available
plate and inlet ring made of sendzimir galvanized sheet ready for installation and also suitable for retrofitting.
steel. Ideal solution for confined intake conditions at the fan
and/or if upstream turbulence-inducing fittings are un-
Version for floor mounting:
avoidable. The FlowGrid breaks up the turbulence fields
Cube design, sizes 630 to 1000 with size 200 motor as
and straightens the flow, resulting in distinct noise re-
ready-toinstall cube design intended exclusively for floor
duction.
mounting. Struts made of extruded aluminum sections

22 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 22 28.09.2020 11:55:26


Tender specification
EC centrifugal fans - RadiPac "Standard"
Fan size 250 to 1000

Technical data:

Fan type = __ __ __ __ __ __ - __ __ __ __ - __ __

Information
Air flow qV = _________________________________ m3/h, cfm

Stat. pressure increase pfs = _________________________________ Pa, in wg

Stat. overall efficiency es = _________________________________ %

Operating speed n = _________________________________ min-1

Motor type = EC motor

Type of control = 0-100 % speed control

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Motor efficiency class = IE5

Total power input Ped = _________________________________ kW

Specific fan power SFP = _________________________________ kW/(m3/s)

Nominal voltage range UN = _________________________________ V

Line frequency f = 50 / 60 Hz

Nominal current IN = _________________________________ A

Degree of protection = IP54

Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)

Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)

Perm. ambient temperature T = _______________ to _______________ °C

Accesories
Weight of fan m = _________________________________ kg

Technology
Contacts

EC centrifugal fans - RadiPac EC centrifugal fans - RadiPac Optionally Flow Grid


Support bracket Cube design Air inlet grill
Fan size 250 - 800 Fan size 630 - 1000

Refer to data sheet for dimensions and wiring.

EC centrifugal fans - RadiPac · Edition 2020-08 23

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 23 28.09.2020 11:55:27


RadiPac 250
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: PP plastic
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 6
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 26 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

C sheets.
3 =max.

B 4
5

1200

3
1000 4
4

A
4
800
3
3

3
600 2
2

400 2
2
1

200

0 500 1000 1500


1 1
2000
1 cfm
pfs

qv 500 1000 1500 2000 2500 3000 3500 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

24 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 24 28.09.2020 11:55:31


RadiPac 250

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0250PSPGS R3G250PR04H1
fan ❶ 230 3380 490 2,16 84
❷ 230 3125 520 2,29 77
A ❸ 230 3080 500 2,30 74 -25..+40 IP 55 RP3)

VBH0250PSPGS K3G250PR04H2 Support ❹ 230 3220 500 2,30 78


bracket

Information
Centrifugal
VBS0250PSPGS R3G250PR17I1
fan ❶ 230 3645 630 2,74 87
❷ 230 3490 730 3,19 82
B ❸ 230 3450 750 3,30 78 -25..+40 IP 55 RP3)

VBH0250PSPGS K3G250PR17I2 Support ❹ 230 3500 720 3,15 82


bracket

Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C


Type Part number Fan type

Centrifugal
VBS0250PTPGS R3G250PR02J1
fan ❶ 400 4000 820 1,27 91
❷ 400 4000 1110 1,72 86
C ❸ 400 4000 1180 1,80 83 -25..+40 IP 55 RP4)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


VBH0250PTPGS K3G250PR02J2 Support ❹ 400 4000 1060 1,64 83
bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 25

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 25 28.09.2020 11:55:31


RadiPac 250

A VBS0250PSPGS R3G250PR04H1 (EC centrifugal fan) Dimensions in mm

4x90°
2 M6 (4x)
45°

47.7

Ø172.5±0.3
Ø150±0.35

Ø270
Ø178

+20
1

1000
116.8
3 4

85±10
152.5±1.8

8
10 Ø164±0.35

1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

A VBH0250PSPGS K3G250PR04H2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85
8 ±1
0
Ø11 (4x)

10 3

2
4
1.5 298
5 2 350
187±2 400
234.7±3

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid

26 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 26 28.09.2020 11:55:37


RadiPac 250

B VBS0250PSPGS R3G250PR17I1 (EC centrifugal fan) Dimensions in mm

4x90°

45°
2 M6 (4x)
64.1

Ø172.5±0.3
Ø169±0.35

Ø270
Ø200

Information
1

+20
1000
116.8
152.5±1.8 3 4

85±10
8
10 Ø186±0.5

1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

B VBH0250PSPGS K3G250PR17I2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85

Accesories
8 ±1
0
Ø11 (4x)

10 3

2
4
1.5 298
5 2 350
Technology

187±2 400
251.1±3
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 27

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 27 28.09.2020 11:55:43


RadiPac 250

C VBS0250PTPGS R3G250PR02J1 (EC centrifugal fan) Dimensions in mm

4x90°

2 M6 (4x) 45°

64.1

Ø172.5±0.3
Ø169±0.35

Ø270
Ø200

+20
1

1000
116.8
152.5±1.8 3
4

85±10
8
10 Ø186±0.5

1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 6x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

C VBH0250PTPGS K3G250PR02J2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85
8 ±1
0
Ø11 (4x)

10 3

2
4
1.5 298
5 2 350
187±2 400
251.1±3

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 6x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid

28 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 28 28.09.2020 11:55:49


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 29
EC centrifugal fans - RadiPac · Edition 2020-08
29
RadiPac 250

28.09.2020 11:55:49
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 280
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: PP plastic
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 6
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 32 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

sheets.
C 3 =max.
5

1200
4

B 4
4

800 A 4
3

2
2

400 2

2
1

0 400 800 1200 1600 2000


1 1 1 cfm
pfs

qv 1000 2000 3000 4000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

30 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 30 28.09.2020 11:55:53


RadiPac 280

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0280PSPGS R3G280PR03H1
fan ❶ 230 2990 500 2,18 85
❷ 230 2785 500 2,30 79
A ❸ 230 2670 500 2,30 72 -25..+45 IP 55 RP3)

VBH0280PSPGS K3G280PR03H2 Support ❹ 230 2835 500 2,30 77


bracket

Information
Centrifugal
VBS0280PSPGS R3G280PR04I1
fan ❶ 230 3260 640 2,81 87
❷ 230 3115 730 3,18 82
B ❸ 230 3000 750 3,30 77 -25..+45 IP 55 RP3)

VBH0280PSPGS K3G280PR04I2 Support ❹ 230 3180 720 3,15 82


bracket

Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C


Type Part number Fan type

Centrifugal
VBS0280PTPKS R3G280PS10J1
fan ❶ 400 3400 740 1,17 88
❷ 400 3400 960 1,49 83
C ❸ 400 3400 1050 1,60 80 -25..+45 IP 55 RP4)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


VBH0280PTPKS K3G280PS10J2 Support ❹ 400 3400 930 1,43 85
bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 31

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 31 28.09.2020 11:55:53


RadiPac 280

A VBS0280PSPGS R3G280PR03H1 (EC centrifugal fan) Dimensions in mm

4x90°

2 45°
M6 (4x)

47.7

Ø187.5±0.3
Ø150±0.35

Ø294
Ø178

+20
1

1000
127

85±10
160±1.8 3 4

8
Ø164±0.35
8

1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

A VBH0280PSPGS K3G280PR03H2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85
8 ±1
0
Ø11 (4x)

10 3

2
4
1.25 298
5 2 350
194.5±2 400
242.2±3

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid

32 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 32 28.09.2020 11:56:03


RadiPac 280

B VBS0280PSPGS R3G280PR04I1 (EC centrifugal fan) Dimensions in mm

4x90°

2 45°
M6 (4x)
64.1

Ø187.5±0.3
Ø169±0.35
Ø200

Ø294

Information
+20
1

1000
127

85±10
3 4

8
160±1.8

Ø186±0.5
8

1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

B VBH0280PSPGS K3G280PR04I2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85

Accesories
8 ±1
0
Ø11 (4x)

10 3

2
4
1.25
298
5 2 350
Technology

194.5±2 400
258.6±3
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 33

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 33 28.09.2020 11:56:09


RadiPac 280

C VBS0280PTPKS R3G280PS10J1 (EC centrifugal fan) Dimensions in mm

4x90°

2 45°
M6 (4x)
64.1

Ø187.5±0.3
Ø169±0.35
Ø200

Ø294

+20
1

1000
127

85±10
3 4

8
175±1.8

Ø186±0.5
8

1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 6x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules

C VBH0280PTPKS K3G280PS10J2 (EC centrifugal module with support bracket) Dimensions in mm

1 10
00 +
20

85
8 ±1
0
Ø11 (4x)

10 3

2
4
1.25 298
5 2 350
209.5±2 400
273.6±3

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 6x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid

34 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 34 28.09.2020 11:56:17


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 35
EC centrifugal fans - RadiPac · Edition 2020-08
35
RadiPac 280

28.09.2020 11:56:17
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 310
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 38 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 165 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

sheets.
2000 3 =max.

44
1800

1600 E 3
D 3
6

1400 F
4
4
1200 4
4
1000 C 333
4

3 3 2 2
800 B

600 2
2 2
2

400

200 A

1 1 13500 1 1 cfm
pfs

0 500 1000 1500 2000 2500 3000 4000

qv 1000 2000 3000 4000 5000 6000 7000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

36 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 36 28.09.2020 11:56:21


RadiPac 310

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0310PSRHS R3G310PG5721
fan ❶ 230 3200 875 3,80 93
❷ 230 3200 1380 6,01 84
A ❸ 230 3200 1500 6,50 82 -25..+45 IP 54 RP7)

VBH0310PSRHS K3G310PG5728 Support ❹ 230 3200 1450 6,32 85


bracket

Information
Centrifugal
VBS0310PSRHS R3G310PG9321
fan ❶ 230 3200 1035 4,51 95
❷ 230 3200 1375 6,00 88
B ❸ 230 3200 1500 6,60 81 -25..+55 IP 54 RP7)

VBH0310PSRHS K3G310PG9321 Support ❹ 230 3200 1490 6,50 86


bracket

Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C


Type Part number Fan type

Centrifugal
VBS0310PTPMS R3G310PT08J1
fan ❶ 400 3010 670 1,06 95
❷ 400 3010 1050 1,61 84
C ❸ 400 3010 1230 1,90 78 -25..+40 IP 55 RP4)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


VBH0310PTPMS K3G310PT08J2 Support ❹ 400 3010 1190 1,82 85
bracket

Centrifugal
VBS0310PTPMS R3G310PT10W1
fan ❶ 400 3140 900 1,40 93
❷ 400 3140 1240 1,90 86
D ❸ 400 3140 1370 2,10 81 -40..+40 IP 55 RP4)

VBH0310PTPMS K3G310PT10W1 Support ❹ 400 3140 1315 2,01 84


bracket

Centrifugal
VBS0310PTRLS R3G310PV6903
fan ❶ 400 4000 2200 3,44 105
❷ 400 4000 2855 4,41 93
E ❸ 400 4000 3050 4,70 89 -40..+40 IP 55 RP5)

VBH0310PTRLS K3G310PV6903 Support ❹ 400 4000 2995 4,61 90


bracket

Centrifugal
VBS0310PTRLS R3G310PV6902
fan ❶ 400 4000 1760 2,79 103
❷ 400 4000 2640 4,08 91
F ❸ 400 4000 3000 4,70 86 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 4000 2865 4,42 91


bracket

Accesories
Subject to change Values set in blue are nominal data at operating point with maximum load.

Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 37

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 37 28.09.2020 11:56:21


RadiPac 310

A VBS0310PSRHS R3G310PG5721 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

72

6x6

Ø223.5+1
Ø360
Ø232

1
98.2 M20x1.5 (3x)
179 3
231±2 Ø252 ±0.5
Ø275
6

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm

A VBH0310PSRHS K3G310PG5728 (EC centrifugal module with support bracket) Dimensions in mm

4x90
5 Ø4.5 (4x) 45

1
3
Ø11 (4x)

4
Ø290 15 M20x1.5 (3x) 2
275.5 1 375
347.5 3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid

38 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 38 28.09.2020 11:56:23


RadiPac 310

B VBS0310PSRHS R3G310PG9321 (EC centrifugal fan) Dimensions in mm

2 M10 6x)

72

6x6
0
Ø223.5+1
Ø232

Ø360
4

Information
98.2 1 3 M20x1.5 (3x)
179 Ø252 0.5
204 2 Ø275
6

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm

B VBH0310PSRHS K3G310PG9321 (EC centrifugal module with support bracket) Dimensions in mm

4x90
5 Ø4.5 (4x) 45

1
3

Accesories
Ø9.2 (8x)

4
Ø290 15 M20x1.5 (3x) 2
Technology

248.5 1 375
320.5 3 450
500
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 39

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 39 28.09.2020 11:56:25


RadiPac 310

C VBS0310PTPMS R3G310PT08J1 (EC centrifugal fan) Dimensions in mm

4x9
45° 0°
2 M6 (4x)

108.5
Ø169±0.35

Ø223.5+1
Ø360
Ø200

1 4
98.2 3
179 Ø186±0.5
255.5±1.8

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
EC centrifugal fans - RadiPac · Edition 2020-08

3 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
5 Tightening torque: 1.5 ± 0.2 Nm

C VBH0310PTPMS K3G310PT08J2 (EC centrifugal module with support bracket) Dimensions in mm

4x90
°
45°
Ø4.5 (x4) 5

6
1
Ø11 (4x)

2 3
4

Ø290 15 372
300±2.5 450
408.5±3 500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm

40 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 40 28.09.2020 11:56:32


RadiPac 310

D VBS0310PTPMS R3G310PT10W1 (EC centrifugal fan) Dimensions in mm

4x90
2 M6 (4x) 45

108.5

Ø223.5+1
5
Ø169

Ø360

Information
1
3
98.2
4
179
Ø186 0.5
255.5 2
6 Ø200

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


3 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
5 Tightening torque: 1.5 ± 0.2 Nm

D VBH0310PTPMS K3G310PT10W1 (EC centrifugal module with support bracket) Dimensions in mm

4x90
5 Ø4.5 (4x) 45

1 6

Accesories
Ø11 (4x)

3
2

4
Ø290 15 372
Technology

244 2 450
352.5 3 500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
Contacts

2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm

EC centrifugal fans - RadiPac · Edition 2020-08 41

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 41 28.09.2020 11:56:34


RadiPac 310

E VBS0310PTRLS R3G310PV6903 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø223.5+1
Ø360
Ø232

98.2 3
179 M20x1.5 (3x) Ø252 0.5
227 2 Ø275
6

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

E VBH0310PTRLS K3G310PV6903 (EC centrifugal module with support bracket) Dimensions in mm

4x90
45

5 Ø4.5 (4x)

4
Ø11 (4x)

Ø290 15 M20x1.5 (3x) 2


272.5 2.5 375
343 3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid

42 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 42 28.09.2020 11:56:35


RadiPac 310

F VBS0310PTRLS R3G310PV6902 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)
70

6x6
0
Ø223.5+1
Ø232

Ø360
4

Information
1

98.2 3
179 Ø252 0.5
271 2 Ø275
6

1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 43

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 43 28.09.2020 11:56:36


RadiPac 355
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 46 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

sheets.
4 4 3 =max.
1600
E
6

1400 D 3
3
1200 B

4 4
1000 4
4

33
800
A 3 2
2
600

2
2

2 2
400

200 C

1 14000 1cfm
1
pfs

0 1000 2000 3000

qv 1000 2000 3000 4000 5000 6000 7000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

44 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 44 28.09.2020 11:56:40


RadiPac 355

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0355PSRLS R3G355PH3821
fan ❶ 230 2590 885 3,74 88
❷ 230 2590 1360 5,94 81
A ❸ 230 2590 1500 6,60 80 -25..+40 IP 54 RP7)

VBK0355PSRLS K3G355PH3822 Support ❹ 230 2590 1430 6,23 83


bracket

Information
Centrifugal
VBS0355PSHRS R3G355PG5421
fan ❶ 230 2600 920 4,03 98
❷ 230 2600 1340 5,83 86
B ❸ 230 2600 1500 6,60 79 -25..+40 IP 55 RP7)

VBK0355PSHRS K3G355PG5422 Support ❹ 230 2600 1500 6,60 82


bracket

Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C


Type Part number Fan type

Centrifugal
VBS0355PTPMS R3G355PT12W1
fan ❶ 400 2500 735 1,15 95
❷ 400 2500 1060 1,78 81
C ❸ 400 2500 1300 2,00 77 -40..+40 IP 55 RP4)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


VBH0355PTPMS K3G355PT12W1 Support ❹ 400 2500 1200 1,84 81
bracket

Centrifugal
VBS0355PTRLS R3G355PV7001
fan ❶ 400 3230 1760 2,77 100
❷ 400 3230 2500 3,85 90
D ❸ 400 3230 2900 4,40 85 -40..+40 IP 55 RP5)

VBH0355PTRLS K3G355PV7001 Support ❹ 400 3230 2690 4,13 88


bracket

Centrifugal
VBS0355PTRLS R3G355PV7002
fan ❶ 400 3230 1630 2,58 102
❷ 400 3230 2540 3,91 89
E ❸ 400 3230 2900 4,40 83 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 3230 2625 4,04 89


bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 45

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 45 28.09.2020 11:56:40


RadiPac 355

A VBS0355PSRLS R3G355PH3821 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

72

6x6

Ø252.5+1
Ø232

Ø405
4

110.5 1 M20x1.5 (3x)


199.7 3
272 ±2 Ø252 ±0.5
Ø275
6

1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm

A VBK0355PSRLS K3G355PH3822 (EC centrifugal module with support bracket) Dimensions in mm

5 (4x)

3
Ø11 (4x)

4
15 M20x1.5 (3x) 2
325.5 2 417
397.5 3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid

46 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 46 28.09.2020 11:56:42


RadiPac 355

B VBS0355PSRHS R3G355PG5421 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

72

6x6
0
Ø252.5+1
Ø232

Ø405
4

Information
1
M20x1.5 (3x)
110.5 3
199.7 Ø252 0.5
225 2 Ø275
6

1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm

B VBH0355PSRHS K3G355PG5422 (EC centrifugal module with support bracket) Dimensions in mm

5 (4x)

1
3

Accesories
Ø11 (4x)

4
15 M20x1.5 (3x) 2
279.5 417
Technology

2
351.5 3 450
500
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 47

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 47 28.09.2020 11:56:44


RadiPac 355

C VBS0355PTPMS R3G355PT12W1 (EC centrifugal fan) Dimensions in mm

4x90
2 M6 (4x) 45

108.5

Ø252.5+1
5
Ø169

Ø405
1
110.5 3
199.7 4
251.8 2 6 Ø186 0.5
Ø200

1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
EC centrifugal fans - RadiPac · Edition 2020-08

3 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
5 Tightening torque: 1.5 ± 0.2 Nm

C VBH0355PTPMS K3G355PT12W1 (EC centrifugal module with support bracket) Dimensions in mm

5 (4x)

1 6
Ø11 (4x)

3
2

4
15 414
305.5 2 450
414 3 500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm

48 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 48 28.09.2020 11:56:45


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 49
EC centrifugal fans - RadiPac · Edition 2020-08
49
RadiPac 355

28.09.2020 11:56:45
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 355

D VBS0355PTRLS R3G355PV7001 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø252.5+1
Ø232

Ø405
4

110.5 1 3
199.7 Ø252 0.5
248 2 Ø275
6

1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

D VBH0355PTRLS K3G355PV7001 (EC centrifugal module with support bracket) Dimensions in mm

5 (4x)

1
3
Ø405

Ø11 (4x)

4
15 2
302.5 2 375
372.5 3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid

50 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 50 28.09.2020 11:56:46


RadiPac 355

E VBS0355PTRLS R3G355PV7002 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø252.5+1
Ø232

Ø405
4

Information
1

110.5 3
199.7 Ø252 0.5
292 2 Ø275
6

1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 51

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 51 28.09.2020 11:56:48


RadiPac 400
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 54 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

can be found in the product-specific data


3 =max. sheets.
1600 4 C
4
6

1400

1200
A 3
3
1000 B
4

800

600 2 2
2

400

200

1 1 cfm
1
pfs

0 1000 2000 3000 4000 5000 6000

qv 2000 4000 6000 8000 10000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

52 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 52 28.09.2020 11:56:51


RadiPac 400

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0400PTRNS R3G400PW0301
fan ❶ 400 2700 2175 3,38 98
❷ 400 2700 2980 4,57 90
A ❸ 400 2700 3400 5,20 85 -40..+40 IP 55 RP5)

VBK0400PTRNS K3G400PW0301 Support ❹ 400 2700 3140 4,81 87


bracket

Information
Centrifugal
VBS0400PTTLS R3G400PA2702
fan ❶ 400 2800 2175 3,38 99
❷ 400 2800 3190 4,88 91
B ❸ 400 2800 3650 5,50 86 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 2800 3480 5,32 89


bracket

VBS0400PTTLS R3G400PA2703 Centrifugal


fan

Reso-
VBS0400PTTLS R3G400PA2765 Centrifugal nance-
fan sensor

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


❶ 400 2800 2290 3,54 98
C VBH0400PTTLS K3G400PA2703 Support ❷ 400 2800 3220 4,92 91
-40..+40 IP 55 RP5)
bracket ❸ 400 2800 3650 5,50 86
❹ 400 2800 3430 5,23 89

VBH0400PTTLS K3G400PA27W4 Cube


(FanGrid)

Reso-
VBH0400PTTLS K3G400PA27W5 Cube nance-
(FanGrid) sensor

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 53

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 53 28.09.2020 11:56:52


RadiPac 400

A VBS0400PTRNS R3G400PW0301 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø288.2+1.5
Ø232

Ø455
4

1
128.75 3
225.5 Ø252 0.5
273 3 Ø275
5

1 Accessory part: Inlet ring 40078-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

A VBK0400PTRNS K3G400PW0301 (EC centrifugal module with support bracket) Dimensions in mm

4x90
15 5 Ø9 (4x)

3
Ø455

Ø11 (4x)

4
Ø440 15 2
331.2 2.5 417
401.2 3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid

54 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 54 28.09.2020 11:56:53


RadiPac 400

B VBS0400PTTLS R3G400PA2702 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø285.2+1.5
Ø232

Ø455
4

Information
1

128.8 3
225.5 Ø252 0.5
310 2 Ø275
5

1 Accessory part: Inlet ring 40075-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 55

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 55 28.09.2020 11:56:54


RadiPac 400

C VBS0400PTTLS R3G400PA2703 & R3G400PA2765 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6

Ø285.2+1.5
Ø232

Ø455
4

M20x1.5 (3x)
128.75 1 3
225.5 Ø252 ±0.5
273 ±2 Ø275
5

1 Accessory part: Inlet ring 40075-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm

C VBH0400PTTLS K3G400PA2703 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
Ø9 (4x) 5 35°

1
3
Ø455

Ø11 (8x)

4
Ø440 15 M20x1.5 (3x) 2
331.2±2.5 417
401.2±3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid

56 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 56 28.09.2020 11:56:57


RadiPac 400

C VBH0400PTTLS K3G400PA27W4 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø9 (4x) 35° Ø9 (16x)

200
1

200
3

Information
200
2
Ø440 20
4
699 40
445
522

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid

C VBH0400PTTLS K3G400PA27W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø9 (4x) 35° Ø9 (16x)
200

1
200

Accesories
200

2
Ø440 20
4
699 40
Technology

445
522
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 57

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 57 28.09.2020 11:56:59


RadiPac 450
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 60 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

3 =max. can be found in the product-specific data


F sheets.
1800 4

1600 4
C E 4
6

1400 3
4
B
1200 3
44 3
1000 A
4

800 3 2

600 2 22
2

400 22 D

200

111 11 1
pfs

0 1000 2000 3000 4000 5000 6000 7000 8000 cfm

qv 2000 4000 6000 8000 10000 12000 14000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

58 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 58 28.09.2020 11:57:03


RadiPac 450

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0450PTRNS R3G450PW1202
fan ❶ 400 2040 1515 2,42 93
❷ 400 2040 2160 3,36 86
A ❸ 400 2040 2650 4,10 79 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 2040 2530 3,90 85


bracket

Information
Centrifugal
VBS0450PTRNS R3G450PW1201
fan ❶ 400 2040 1625 2,58 95
❷ 400 2040 2210 3,43 87
B ❸ 400 2040 2650 4,10 80 -40..+40 IP 55 RP5)

VBH0450PTRNS K3G450PW1201 Support ❹ 400 2040 2585 3,99 84


bracket

Centrifugal PFC
VBS0450PTTLS R3G450PA21C1
fan active ❶ 400 2200 1960 2,84 96
❷ 400 2200 2915 4,20 88
C ❸ 400 2200 3190 4,60 87 -25..+40 IP 55 RP1)

VBH0450PTTLS K3G450PA21C1 Support PFC ❹ 400 2200 3000 4,33 90


bracket active

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Centrifugal
VBS0450PTTLS R3G450PA3102
fan ❶ 400 2480 2775 4,26 99
❷ 400 2480 3895 5,93 91
D ❸ 400 2480 4450 6,80 85 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 2480 4450 6,80 89


bracket

VBS0450PTTLS R3G450PA3103 Centrifugal


fan

Reso-
VBS0450PTTLS R3G450PA3165 Centrifugal nance-
fan sensor
❶ 400 2480 2775 4,26 99
Support ❷ 400 2480 3925 5,98 92
E VBH0450PTTLS K3G450PA3103
bracket ❸ 400 2480 4450 6,80 85
-40..+45 IP 55 RP5)
❹ 400 2480 4415 6,71 89

VBH0450PTTLS K3G450PA31W3 Cube


(FanGrid)

Reso-
VBH0450PTTLS K3G450PA31W5 Cube nance-

Accesories
(FanGrid) sensor

Centrifugal
VBS0450PTTPS R3G450PB2401
fan ❶ 400 2600 3065 4,78 102
❷ 400 2600 4640 7,13 92
F ❸ 400 2600 5250 8,00 87 -25..+50 IP 55 RP1)
Support ❹ 400 2600 5140 7,89 91
Technology

VBH0450PTTPS K3G450PB2401
bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 59

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 59 28.09.2020 11:57:03


RadiPac 450

A VBS0450PTRNS R3G450PW1202 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø319.7+1.5
Ø232

Ø530
4

140.2 3
253.6 Ø252 0.5
368 3 Ø275
5

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

60 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 60 28.09.2020 11:57:04


RadiPac 450

B VBS0450PTRNS R3G450PW1201 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø319.7+1.5
Ø232

Ø530
4

Information
140.2 1 3
253.6 Ø252 0.5
304 3 Ø275
5

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

B VBH0450PTRNS K3G450PW1201 (EC centrifugal module with support bracket) Dimensions in mm

4x90
5 Ø10 (4x) 15

1
3

Accesories
Ø11 (8x)

4
Ø440 15 2
369.5 2 551
439.5 3 580
Technology

630
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 61

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 61 28.09.2020 11:57:05


RadiPac 450

C VBS0450PTTLS R3G450PA21C1 (EC centrifugal fan and PFC, active) Dimensions in mm

2 M10 (6x)

113

6x6

Ø319.7+1.5
Ø280

Ø530
5

140 M20x1.5 (2x) 3


1
254 4 M25x1.5
309±2 Ø304 ±0.5
5
Ø324

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

C VBH0450PTTLS K3G450PA21C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm

4x90°
15°
6 Ø10 (4x)

1
4
Ø530

5
Ø11 (8x)

Ø440 15 M20x1.5 (2x) 2


3
374.5±2 M25x1.5
488 ±3 580
622
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 240)
6 Mounting holes: for FlowGrid

62 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 62 28.09.2020 11:57:07


RadiPac 450

D VBS0450PTTLS R3G450PA3102 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø319.7+1.5
Ø232

Ø530
4

Information
1

140.2 3
253.6 Ø252 0.5
341 2 5 Ø275

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 63

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 63 28.09.2020 11:57:08


RadiPac 450

E VBS0450PTTLS R3G450PA3103 & R3G450PA3165 (EC centrifugal fan) Dimensions in mm

6x60°
304±2 2
M10 (6x)

60
70

°
Ø319,7+1,5
Ø232

Ø530
Ø275

140,2 3
253,6 Ø252±0,5
5

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

E VBH0450PTTLS K3G450PA3103 (EC centrifugal module with support bracket) Dimensions in mm

Ø10 (4
x) 5
4x90°
15°

1
3
Ø11 (8x)

Ø440 369,5±2,5 15 2 M20x1,5 (3x)


439,5±3 551
580
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid

64 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 64 28.09.2020 11:57:19


RadiPac 450

E VBH0450PTTLS K3G450PA31W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø10 (4x) 15° Ø9 (16x)

200
1

200
3

200

Information
2
Ø440 20
4
799 40
483
620

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid

E VBH0450PTTLS K3G450PA31W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø10 (4x) 15° Ø9 (16x)
200

1
200

Accesories
200

2
Ø440 20
4
799 40
483
Technology

620
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 65

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 65 28.09.2020 11:57:21


RadiPac 450

F VBS0450PTTPS R3G450PB2401 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

113

6x6

Ø319.7+1.5
Ø280

Ø530
5

1
M20x1.5 (2x)
3
140 M25x1.5
4
254
376 ±2 Ø304 ±0.5
5 Ø324

1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 25 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

F VBH0450PTTPS K3G450PB2401 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
6 Ø9 (4x) 15°

1
4
Ø530

Ø11 (8x)

M25x1.5

5
Ø440 15 M20x1.5 (2x) 2
3
442.5±2
556±3 580
622
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 240)
6 Mounting holes: for FlowGrid

66 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 66 28.09.2020 11:57:23


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 67
EC centrifugal fans - RadiPac · Edition 2020-08
67
RadiPac 450

28.09.2020 11:57:23
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 500
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 70 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

can be found in the product-specific data


3 =max.
sheets.
1600 F
E 4
D
6

1400

4 4
4
1200 C 3
4
1000 B 3 33
4

4
3
800 A
3 2
600

2 22
2

400 2

200

1 8000 1 11 1
pfs

0 2000 4000 6000 10000 cfm

qv 2000 4000 6000 8000 10000 12000 14000 16000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

68 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 68 28.09.2020 11:57:27


RadiPac 500

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0500PTRNS R3G500PW0901
fan ❶ 400 1670 1340 2,17 100
❷ 400 1670 2020 3,16 89
A ❸ 400 1670 2350 3,60 80 -40..+40 IP 55 RP5)

VBH0500PTRNS K3G500PW0901 Support ❹ 400 1670 2175 3,39 83


bracket

Information
Centrifugal PFC
VBS0500PTTLS R3G500PA26C1
fan active ❶ 400 1810 1800 2,60 102
❷ 400 1810 2700 3,90 91
B ❸ 400 1810 3100 4,50 82 -25..+40 IP 55 RP1)

VBH0500PTTLS K3G500PA26C1 Support PFC ❹ 400 1810 2850 4,10 86


bracket active

Centrifugal
VBS0500PTTLS R3G500PA2803
fan ❶ 400 1890 2020 3,16 101
❷ 400 1890 2950 4,53 92
C ❸ 400 1890 3350 5,20 85 -40..+40 IP 55 RP5)

VBH0500PTTLS K3G500PA2803 Support ❹ 400 1890 3165 4,85 87


bracket

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Centrifugal
VBS0500PTTPS R3G500PB2402
fan ❶ 400 2000 2290 3,55 103
❷ 400 2000 3290 5,03 94
D ❸ 400 2000 3900 6,00 86 -40..+45 IP 55 RP5)

--- --- Support ❹ 400 2000 3725 5,68 89


bracket

VBS0500PTTPS R3G500PB2403 Centrifugal


fan

Reso-
VBS0500PTTPS R3G500PB2465 Centrifugal nance-
fan sensor
❶ 400 2000 2410 3,73 101
E VBH0500PTTPS K3G500PB2403 Support ❷ 400 2000 3375 5,15 93
-40..+45 IP 55 RP5)
bracket ❸ 400 2000 3900 6,00 86
❹ 400 2000 3750 5,71 88

VBH0500PTTPS K3G500PB24W3 Cube


(FanGrid)

Reso-
VBH0500PTTPS K3G500PB24W5 Cube nance-

Accesories
(FanGrid) sensor

Centrifugal
VBS0500PTTPS R3G500PB3301
fan ❶ 400 2250 3240 5,05 105
❷ 400 2250 4860 7,47 95
F ❸ 400 2250 5700 9,00 88 -25..+40 IP 55 RP1)
Support ❹ 400 2250 5700 8,74 87
Technology

VBH0500PTTPS K3G500PB3301
bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 69

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 69 28.09.2020 11:57:27


RadiPac 500

A VBS0500PTRNS R3G500PW0901 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6

Ø355 +2
Ø232

Ø585
4

1 M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 Ø275
5

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

A VBH0500PTRNS K3G500PW0901 (EC centrifugal module with support bracket) Dimensions in mm

4x90
5 Ø9 (4x) 15

1
3
Ø585

Ø11 (8x)

4
Ø440 15 M20x1.5 (3x) 2
401 2 551
471 3 580
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid

70 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 70 28.09.2020 11:57:28


RadiPac 500

B VBS0500PTTLS R3G500PA26C1 (EC centrifugal fan with PFC, active) Dimensions in mm

2 M10 (6x)

113

6x6

Ø355±2
Ø585
Ø280

Information
1
156 M20x1.5 (2x) 3
282 4 M25x1.5
341±2 Ø304±0.5
5 Ø324

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

B VBH0500PTTLS K3G500PA26C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm

4x90°
6 Ø10 (4x) 15°

4
Ø585

Accesories
Ø11 (8x)

0.5

Ø440 15 M20x1.5 (2x) 2


3
406±2 M25x1.5
Technology

519.5±3 580
622
630
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 281)
6 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 71

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 71 28.09.2020 11:57:30


RadiPac 500

C VBS0500PTTLS R3G500PA2803 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6

Ø355+2
Ø232

Ø585
4

1 M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 Ø275
5

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

C VBH0500PTTLS K3G500PA2803 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
Ø10 (4x) 5 15°

1
3
Ø585

Ø11 (8x)

4
Ø440 15 M20x1.5 (3x) 2
401±2.5 551
471±3 580
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid

72 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 72 28.09.2020 11:57:32


RadiPac 500

D VBS0500PTTPS R3G500PB2402 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø355 +2
Ø585
Ø232

Information
1

156 3
282 Ø252 0.5
403 2 5 Ø275

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 73

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 73 28.09.2020 11:57:33


RadiPac 500

E VBS0500PTTPS R3G500PB2403 & R3G500PB2465 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6

Ø355+2
Ø232

Ø585
4

1
M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 5
Ø275

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

E VBH0500PTTPS K3G500PB2403 (EC centrifugal module with support bracket) Dimensions in mm

Ø9 (4x) 5 15°

1
3
Ø585

Ø11 (8x)

4
Ø440 15 M20x1.5 (3x) 2
401±2.5 551
471±3 580
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid

74 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 74 28.09.2020 11:57:35


RadiPac 500

E VBH0500PTTPS K3G500PB24W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø9 (4x) 15° Ø9 (16x)

225
1

225
3

225

Information
2
Ø440 20
4
899 40
514
651

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid

E VBH0500PTTPS K3G500PB24W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø9 (4x) 15° Ø9 (16x)
225

1
225

Accesories
225

2
Ø440 20
4
899 40
514
Technology

651
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 75

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 75 28.09.2020 11:57:37


RadiPac 500

F VBS0500PTTPS R3G500PB3301 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

113

6x6

Ø355 +2
Ø280

Ø585
5

M20x1.5 (2x)
1 3
156 M25x1.5
282 4
408 ±2 Ø304 ±0.5
Ø324
5

1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

F VBH0500PTTPS K3G500PB3301 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
6 Ø8 (4x) 15°

4
Ø585

Ø11 (8x)

Ø440 M20x1.5 (2x) 2


5 3
15 M25x1.5
473.5 ±2 580
587±3 622
630

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 281)
6 Mounting holes: for FlowGrid

76 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 76 28.09.2020 11:57:39


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 77
EC centrifugal fans - RadiPac · Edition 2020-08
77
RadiPac 500

28.09.2020 11:57:39
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 560
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 80 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

D can be found in the product-specific data


3 =max. sheets.
1400

4
1200 C 4
B 4

1000 3
4

4
33
A
800

3
600

22 2
2

400 2

200

1 1 1cfm
pfs

0 2000 4000 6000 8000 10000

qv 2000 4000 6000 8000 10000 12000 14000 16000 18000 m³/h
Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

78 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 78 28.09.2020 11:57:43


RadiPac 560

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal PFC
VBS0560PTTPS R3G560PB22C1
fan active ❶ 400 1470 1800 2,60 96
❷ 400 1470 2710 3,94 87
A ❸ 400 1470 3060 4,40 79 -25..+40 IP 55 RP1)

VBH0560PTTPS K3G560PB22C1 Support PFC ❹ 400 1470 2830 4,10 83


bracket active

Information
Centrifugal
VBS0560PTTPS R3G560PB3102
fan ❶ 400 1700 2520 3,89 103
❷ 400 1700 3830 5,84 92
B ❸ 400 1700 4400 6,60 84 -40..+40 IP 55 RP5)

--- --- Support ❹ 400 1700 4270 6,50 87


bracket

VBS0560PTTPS R3G560PB3103 Centrifugal


fan

Reso-
VBS0560PTTPS R3G560PB3165 Centrifugal nance-
fan sensor

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


❶ 400 1700 2500 3,86 102
C VBH0560PTTPS K3G560PB3103 Support ❷ 400 1700 3765 5,74 90
-40..+40 IP 55 RP5)
bracket ❸ 400 1700 4250 6,50 82
❹ 400 1700 4070 6,20 85

VBH0560PTTPS K3G560PB31W3 Cube


(FanGrid)

Reso-
VBH0560PTTPS K3G560PB31W5 Cube nance-
(FanGrid) sensor

Centrifugal
VBS0560PTTRS R3G560PC0401
fan ❶ 400 1760 2790 4,36 101
❷ 400 1760 4250 6,52 92
D ❸ 400 1760 5000 7,70 84 -25..+40 IP 55 RP1)

VBH0560PTTRS K3G560PC0401 Support ❹ 400 1760 4790 7,32 87


bracket

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 79

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 79 28.09.2020 11:57:43


RadiPac 560

A VBS0560PTTPS R3G560PB22C1 (EC centrifugal fan with PFC, active) Dimensions in mm

2 M10 (6x)

113

6x6

Ø398.2+2
Ø280

Ø655
5

1
175 M20x1.5 (2x) 3
314 4 M25x1.5
370.5±2 Ø304 ±0.5
6
Ø324

1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

A VBH0560PTTPS K3G560PB22C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm

4x90°
15°

6 Ø10 (4x)

1
4
Ø655

M25x1.5
Ø11 (8x)

Ø545 5 M20x1.5 (2x) 2


3
15 750
441.5±2 792
555 ±3 800

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 348)
6 Mounting holes: for FlowGrid

80 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 80 28.09.2020 11:57:45


RadiPac 560

B VBS0560PTTPS R3G560PB3102 (EC centrifugal fan with PFC, active) Dimensions in mm

2 M10 (6x)

70

6x6
0
Ø398.2 +2
Ø655
Ø232

Information
1

174.6 3
314 Ø252 0.5
433 2 6 Ø275

1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 81

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 81 28.09.2020 11:57:46


RadiPac 560

C VBS0560PTTPS R3G560PB3103 & R3G560PB3165 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

70

6x6

Ø398.2+2
Ø232

Ø655
4

1 M20x1.5 (3x)
174.6 3
314.3 Ø252 ±0.5
366 ±2 Ø275
6

1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

C VBH0560PTTPS K3G560PB3103 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
Ø10 (4x) 5 15°

1
3
Ø655

Ø11 (8x)

4
Ø545 15 M20x1.5 (3x) 2
436.5±2.5 555
506.5±3 750
800

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 348)
5 Mounting holes: for FlowGrid

82 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 82 28.09.2020 11:57:49


RadiPac 560

C VBH0560PTTPS K3G560PB31W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø10 (4x) 15° Ø9 (16x)

250
1

250
3

250

Information
2

Ø545 20
4
999 40
550
722

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 348)
5 Mounting holes: for FlowGrid

C VBH0560PTTPS K3G560PB31W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm

4x90°
5 Ø10 (4x) 15° Ø9 (16x)
250

1
250

Accesories
250

2
Ø545 20
4
999 40
Technology

550
722
Contacts

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 348)
5 Mounting holes: for FlowGrid

EC centrifugal fans - RadiPac · Edition 2020-08 83

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 83 28.09.2020 11:57:51


RadiPac 560

D VBS0560PTTRS R3G560PC0401 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

113

6x6

Ø398.2+2
Ø280

Ø655
5

1 M20x1.5 (2x)
175 3 M25x1.5
314 4
472.5±2 Ø304 ±0.5
Ø324
6

1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm

D VBH0560PTTRS K3G560PC0401 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
Ø10 (4x) 6 15°

1
4
Ø655

Ø11 (8x)

M25x1.5

5
Ø545 15 M20x1.5(2x) 2
544.5±2 3
658 ±3 750
792
800

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 348)
6 Mounting holes: for FlowGrid

84 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 84 28.09.2020 11:57:53


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 85
EC centrifugal fans - RadiPac · Edition 2020-08
85
RadiPac 560

28.09.2020 11:57:53
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 630
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 88 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

can be found in the product-specific data


3 =max. sheets.
1800 C 4

1600

3
6

4
1400 B

1200

3
1000
A 4
4

800 2
3

600
2
2

400 2

200

1 1 1
pfs

0 2000 4000 6000 8000 10000 12000 14000 cfm

qv 5000 10000 15000 20000 25000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

86 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 86 28.09.2020 11:57:57


RadiPac 630

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0630PTTRS R3G630PC0803
fan ❶ 400 1500 2295 3,65 93
❷ 400 1500 3520 5,38 86
A ❸ 400 1500 4250 6,50 82 -40..+40 IP 55 RP5)

VBH0630PTTRS K3G630PC0803 Support ❹ 400 1500 4165 6,33 84


bracket

Information
Centrifugal
--- ---
fan ❶ 400 1750 3735 5,89 99
❷ 400 1750 6000 9,22 90
B ❸ 400 1750 7060 10,80 86 -40..+40 IP 55 RP1)

VBF0630PTVNS K3G630PV0401 Cube


❹ 400 1750 6900 10,55 89

Centrifugal
--- ---
fan ❶ 400 1950 5080 8,40 105
❷ 400 1950 8400 13,19 96
C ❸ 400 1950 9780 15,20 89 -40..+40 IP 55 RP1)

VBF0630PTVQS K3G630PW0401 Cube


❹ 400 1950 9330 14,55 94

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 87

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 87 28.09.2020 11:57:57


RadiPac 630

A VBS0630PTTRS R3G630PC0803 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

6x6
70


Ø446.8+2.5
Ø232

Ø716
4

M20x1.5 (3x)
1 3
190.6
333.5 Ø252 ±0.5
384 ±3 Ø275
10

1 Accessory part: Inlet ring 64045-2-4013 with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

A VBH0630PTTRS K3G630PC0803 (EC centrifugal module with support bracket) Dimensions in mm

4x90°
5 Ø10 (4x) 15°

1
3
Ø716

Ø11 (8x)

4
Ø545 15 M20x1.5 (3x) 2
467.5±2.5 750
537.5±3 792
800

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 438)
5 Mounting holes: for FlowGrid

88 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 88 28.09.2020 11:57:59


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 89
EC centrifugal fans - RadiPac · Edition 2020-08
89
RadiPac 630

28.09.2020 11:58:00
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 630

B VBF0630PTVNS K3G630PV0401 (EC centrifugal module with cube design) Dimensions in mm

273.7
2 5
M10 (4x)

260
M20x1.5 (2x) 3
4 M25x1.5
676
4x90°
6 Ø10 (4x) 45°
7
Ø545

1
Ø9 (16x)
EC centrifugal fans - RadiPac · Edition 2020-08

250 20
600 532.7
666 663.7
760

1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

90 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 90 28.09.2020 11:58:01


RadiPac 630

C VBF0630PTVQS K3G630PW0401 (EC centrifugal module with cube design) Dimensions in mm

301.9
2
5
M10 (4x)

278.8
M20x1.5 (2x) 3
4 M25x1.5
676

Information
4x90°
6 Ø10 (4x) 45°
7
Ø545

1
Ø9 (16x)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


250 20
600 571.7
666 710.7
760

1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 91

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 91 28.09.2020 11:58:02


RadiPac 710
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 94 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

can be found in the product-specific data


sheets.
1800 3 =max.
4
1600 C
6

1400

3
4
1200
B

1000 A 3
4

4
800

2
3
600

2
2

400
2

200

1 1 1
pfs

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 cfm

qv 5000 10000 15000 20000 25000 30000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

92 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 92 28.09.2020 11:58:06


RadiPac 710

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0710PTTRS R3G710PC0503
fan ❶ 400 1150 1950 3,05 83
❷ 400 1150 3195 4,90 81
A ❸ 400 1150 3750 5,70 78 -40..+40 IP 55 RP5)

VBH0710PTTRS K3G710PC0503 Support ❹ 400 1150 3485 5,33 81


bracket

Information
Centrifugal
--- ---
fan ❶ 400 1430 3730 5,88 89
❷ 400 1430 5785 8,90 86
B ❸ 400 1430 7050 10,70 84 -40..+40 IP 55 RP1)

VBF0710PTVQS K3G710PV0501 Cube


❹ 400 1430 6765 10,35 86

Centrifugal
--- ---
fan ❶ 400 1680 5995 9,70 91
❷ 400 1680 9630 15,00 87
C ❸ 400 1680 11450 17,70 85 -40..+40 IP 55 RP1)

VBF0710PTVTS K3G710PW0601 Cube


❹ 400 1680 10745 16,65 89

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 93

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 93 28.09.2020 11:58:06


RadiPac 710

A VBS0710PTTRS R3G710PC0503 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

6x6
70

0
Ø503.6+2.5
Ø232

Ø806
4

M20x1.5 (3x)
1 3
214.9
374.9 Ø252 0.5
426 2 Ø275
10

1 Accessory part: Inlet ring 71075-2-4013 with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 2±0,3 Nm
4 Tightening torque: 1,5±0,2 Nm

A VBH0710PTTRS K3G710PC0503 (EC centrifugal module with support bracket) Dimensions in mm

4x90 880
5 Ø10 (4x) 45 600

1
3
Ø806

Ø11 (12x)

4
Ø630 25 M20x1.5 (3x) 2
527.5 2.5 777
597.5 3 960

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 2±0,3 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 545)
5 Mounting holes: for FlowGrid

94 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 94 28.09.2020 11:58:09


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 95
EC centrifugal fans - RadiPac · Edition 2020-08
95
RadiPac 710

28.09.2020 11:58:09
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 710

B VBF0710PTVQS K3G710PV0501 (EC centrifugal module with cube design) Dimensions in mm

268.4
2
M10 (4x)

350.8
5

M20x1.5 (2x) 3
876 4 M25x1.5

4x90°
6 Ø10 (4x) 45° 7
Ø9 (12x)

250
Ø630
786

1
EC centrifugal fans - RadiPac · Edition 2020-08

Ø11 (12x)

600 40
880 618.2
960 749.2

1 Inlet ring: with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

96 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 96 28.09.2020 11:58:10


RadiPac 710

C VBF0710PTVTS K3G710PW0601 (EC centrifugal module with cube design) Dimensions in mm

239.6
2
5

451.6
M10 (4x)

M20x1.5 (2x)
3 M25x1.5
4
876

Information
4x90°
6 Ø10 (4x) 45° 7
Ø9 (12x)

250

786
Ø630

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


9
Ø11 (12x)

600 40
880 682.2
960 821.2

1 Inlet ring: with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 97

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 97 28.09.2020 11:58:11


RadiPac 800
EC centrifugal fans, backward curved

Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 100 Drawings


■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa

3 =max. can be found in the product-specific data


sheets.
1600
6

4
1400 C
B

1200
4
3
1000
4

3
800
A
600 2
4
2
2

400 3

200 2

1 1 1 cfm
pfs

0 5000 10000 15000 20000

qv 5000 10000 15000 20000 25000 30000 35000 40000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

98 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 98 28.09.2020 11:58:15


RadiPac 800

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
VBS0800PTTRS R3G800PC0203
fan ❶ 400 845 1520 2,42 80
❷ 400 845 2235 3,47 77
A ❸ 400 845 2800 4,30 74 -40..+40 IP 55 RP5)

VBH0800PTTRS K3G800PC0203 Support ❹ 400 845 2680 4,13 76


bracket

Information
Centrifugal
--- ---
fan ❶ 400 1215 4250 6,64 89
❷ 400 1215 6890 10,55 85
B ❸ 400 1215 7950 12,10 83 -25..+40 IP 55 RP1)

VBF0800PTVTS K3G800PV1301 Cube


❹ 400 1215 7530 11,51 86

Centrifugal
--- ---
fan ❶ 400 1370 6370 10,26 91
❷ 400 1370 9600 14,99 88
C ❸ 400 1370 11300 17,50 85 -25..+40 IP 55 RP1)

VBT0800PTVTS K3G800PW0701 Cube


❹ 400 1370 10990 17,04 88

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 99

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 99 28.09.2020 11:58:15


RadiPac 800

A VBS0800PTTRS R3G800PC0203 (EC centrifugal fan) Dimensions in mm

2 M10 (6x)

6x6
0
70

Ø566.3+3
Ø232

Ø909
4

M20x1.5 (3x)
1
244.3 3
418.8 Ø252 0.5
471.3 2 Ø275
20

1 Accessory part: Inlet ring 80075-2-4013 with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm

A VBH0800PTTRS K3G800PC0203 (EC centrifugal module with support bracket) Dimensions in mm

4x90
45
Ø9 (4x) 5

Ø 75
0
1
Ø909
Ø11 (16x)

3
4

600 586.8 2.5 25 M20x1.5 (3x) 2


880 657 3 930
960

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 695)
5 Mounting holes: for FlowGrid

100 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 100 28.09.2020 11:58:17


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 101
EC centrifugal fans - RadiPac · Edition 2020-08
101
RadiPac 800

28.09.2020 11:58:17
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


RadiPac 800

B VBF0800PTVTS K3G800PV1301 (EC centrifugal module with cube design) Dimensions in mm

307.6
M10 (4x) 2

420.4
M20x1.5 (2x)
3 M25x1.5
4
876

4x90°
6 Ø9 (4x) 45° 7
Ø9 (12x)

250

786
Ø750

1
EC centrifugal fans - RadiPac · Edition 2020-08

9.5
Ø11 (12x)

600 40
880 727
960 858

1 Inlet ring: with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

102 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 102 28.09.2020 11:58:19


RadiPac 800

C VBT0800PTTVS K3G800PW0701 (EC centrifugal module with cube design) Dimensions in mm

258.4
2

491.6
M10 (4x)

M20x1.5 (2x) 3
4 M25x1.5
876

Information
4x90°
6 Ø9 (4x) 45°
7
Ø9 (12x)

250
Ø750
786

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Ø11 (12x)

600 40
880 741
960 880

1 Inlet ring: with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 103

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 103 28.09.2020 11:58:20


RadiPac 1000
EC centrifugal fans, backward curved

Material/surface
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 106 Drawings


■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

A sheets.
800 3 =max.
3

700 4
2.5

600

3
500
2

400
1.5

300 2
1

200
0.5

100

1cfm
pfs

0 5000 10000 15000 20000 25000

qv 10000 20000 30000 40000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

104 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 104 28.09.2020 11:58:24


RadiPac 1000

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
--- ---
fan ❶ 400 750 3540 5,63 84
❷ 400 750 5485 8,49 80
A ❸ 400 750 6340 9,80 77 -25..+40 IP 55 RP1)

VBF1000PTVTS K3GA00PV0301 Cube


❹ 400 750 6122 9,40 79

Information
Subject to change Values set in blue are nominal data at operating point with maximum load.

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 105

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 105 28.09.2020 11:58:24


RadiPac 1000

A VBF1000PTVTS K3GA00PV0301 (EC centrifugal module with cube design) Dimensions in mm

277.9
2
5
M10 (4x)

465.2
M20x1.5 (2x) 3
4 M25x1.5
1096

4x90°
6 Ø9 (4x) 45° 7
Ø 960
Ø9 (20x)

1036
250
750

1
EC centrifugal fans - RadiPac · Edition 2020-08

Ø11 (12x)

800 30
1100 742.1
1180 873.1

1 Inlet ring: with pressure tap (k-factor: 1200) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

106 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 106 28.09.2020 11:58:25


RadiPac 1000

Information
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 107

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 107 28.09.2020 11:58:25


Standard-compliant ventilation with ready-to-install RadiPacs
for the food service sector and process exhaust air:
There’s something in the air. Operators of commercial kitchens have a thing or two to say about that; cooking fouls the surroun-
ding air with grease vapors and combustion gases, not to mention heat and moisture. All that can quickly make the air quality
reach hygienically questionable levels, not only in the kitchen but also in the serving area and throughout the dining areas – whe-
re bad smells can ruin the pleasant atmosphere. So legislation calls for the installation of air handling units (AHUs) in these areas.
They extract air pollutants, moisture and odors from the air and bring in cool and clean air from outside.

Radically perfect with RadiPac.

Keeping air clean in canteens and


cafeterias can be challenging. To
improve air quality, fans used in
AHUs have to meet special require-
ments. According to VDI 2052, mo-
tors may not lie directly in the path
of air flows bearing particulates.

In addition, incoming air must be


kept free of contaminants and, ac-
cording to EN 16282, the fans need
to be easily accessible and easy to
clean. At the same time, the AHUs
have to serve as humidity and tem-
perature control in the rooms.

To meet this challenge, ebm-papst


modified its proven RadiPac pro-
duct range with EC centrifugal fans
and optimized it for these special
conditions. Now, manufacturers of
AHUs for the food service sector
and emissions-heavy processes or
higher flow medium temperatures
can finally benefit from the ad-
vantages of energy-efficient EC
technology as these fans meet all
their requirements.

108 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 108 28.09.2020 11:58:27


RadiPac 400 - 500
for the food service sector

the engineer’s choice


Page

Tender specification 110

Information
400 - 500 112

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 109

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 109 28.09.2020 11:58:28


Tender specification
EC centrifugal modules - RadiPac "Gastronomy"
with motor enclosure and hose for food service sector
Fan size 400 to 500

Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics and a motor enclosure.

Impeller made of aluminum, with 7 backwards-curved, con- Support structure, ready to install, for wall mounting.
tinuously welded blades; flow-optimized inlet ring made of Struts made of extruded aluminum profile. Mounting
galvanized sheet steel with pressure test nipple. plate made of galvanized sheet steel. Ready-made intake
nozzle for external air supply DN 100. Pre-installed, flexible
Motor-impeller in accordance with DIN ISO 21940, stati-
air hose between motor capsule and nozzle plate; easily
cally and dynamically balanced on two planes to balancing
replaceable; good mechanical resistance, flame retardant
grade G 6.3.
in accordance with UL 94 V-0. Easy cleaning and inspection
in accordance with EN 16282.
EC centrifugal fans - RadiPac · Edition 2020-08

FlowGrid air-inlet grille, for reducing mounting-related and


system-related noise. Ideal solution for confined intake
Any work required for isolation from structure-borne noise
conditions at the fan and/or if upstream turbulence-in-
is to be performed by the customer. The fan satisfies the
ducing fittings are unavoidable. The FlowGrid breaks up
applicable EMC guidelines and requirements with regard
the turbulence fields and straightens the flow, resulting in
to harmonic effects (see applicable data sheet for specific
distinct noise reduction.
figures). Documentation and marking in accordance with
GreenTech EC external rotor motor surpasses efficiency the applicable EU directives.
class IE4, permanent magnets with no rare earths, main-
Reliable performance data, air performance measurements
tenance-free ball bearings with long-term lubrication,
in intake-side chamber test rig according to ISO 5801 and
theoretical nominal service life of at least 40.000 hours of
DIN 24163, sound measurements in an anechoic test cham-
operation.
ber in accordance with DIN EN ISO 3745.
Soft start, integrated current limitation, extended voltage
Integrated protective devices:
input 3~380-480 V, 50/60 Hz. The fan can be used with all
- Alarm relay with floating contacts
standard power supply networks with unaltered air perfor-
(250 V AC/2 A, cos w = 1)
mance.
- Locked-rotor protection
The motor and control electronics have been removed - Phase failure detection
from the contaminated air flow in accordance with VDI - Soft start of motors
2052 and EN 16282. Motor and control system in accordan- - Line undervoltage detection
ce with EN 60335-1. - Thermal overload protection for electronics and motor
- Short circuit protection
Electronics integrated in motor enclosure, low-noise
commutation logic; 100% open-loop speed control; all fans Optional:
have an RS485/MODBUS RTU interface and do not need to - Other and specific requirements on request
be installed with shielded cables.

Terminal box made of aluminum integrated into housing,


cover made of PA66, with easily accessible connection
area, environment-resistant cable glands. Robust, corro-
sion-resistant motor enclosure, completely sealed (IP54),
made of CDP-coated sheet steel.

110 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 110 28.09.2020 11:58:28


Tender specification
EC centrifugal modules - RadiPac "Gastronomy"
with motor enclosure and hose for food service sector
Fan size 400 to 500

Technical data:

Fan type = K3G __ __ __ - __ __ __ __ - __ __

Information
Air flow qV = _________________________________ m3/h, cfm

Stat. pressure increase pfs = _________________________________ Pa, in wg

Stat. overall efficiency es = _________________________________ %

Operating speed n = _________________________________ rpm

Motor type = EC motor

Type of control = 0-100 % speed control

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Motor efficiency class = IE4

Total power input Ped = _________________________________ kW

Specific fan power SFP = _________________________________ kW/(m3/s)

Nominal voltage range UN = _________________________________ V

Line frequency f = 50 / 60 Hz

Nominal current IN = _________________________________ A

Degree of protection = IP54

Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)

Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)

Perm. ambient temperature T = _______________ to _______________ °C

Accesories
Weight of fan m = _________________________________ kg

Technology
Contacts

EC centrifugal fans - RadiPac


with motor enclosure and hose for food service sector
Sizes 400, 450 and 500

Refer to data sheet for dimensions and wiring.

EC centrifugal fans - RadiPac · Edition 2020-08 111

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 111 28.09.2020 11:58:28


RadiPac 400 - 500
EC centrifugal modules for the food service sector

Material/surface
■ Housing: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
Mechanical characteristics
■ Number of blades: 7
■ Direction of rotation: anticlockwise seen
the shaft
■ Installation position: See product drawing
■ Mode: Continuous operation (S1)
■ Mounting: Maintenance-free ball bearings
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 114 Drawings Further Information


on Page 152 Accesories
■ Information about touch current, electrical
on Page 164 Connection diagrams and technical features connection, degree of protection, insulation
on Page 180 Technical parameters & scope class, environmental protection class, EMC
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
standards as well as standards and approvals
can be found in the product-specific data
sheets.
in. wg
Pa

3 =max.

1400

4
1200

4
1000 4 3
4

3
800 3 C

600 2 2
2
2

400 A

200 1 1 1

B
pfs

0 1000 2000 3000 4000 5000 6000 cfm

qv 2000 4000 6000 8000 10000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, Installationskategorie A. Please contact ebm-papst for the exact measurement setup.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

112 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 112 28.09.2020 11:58:30


RadiPac 400 - 500

Degree of protection
Sound power level

Min. Gegendruck
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) Pa °C
Type Part number Fan type

❶ 400 2550 2170 3,39 90


Centrifugal ❷ 400 2550 2660 4,11 89
A VBH0400NTTLS K3G400AQ27K1
module ❸ 400 2550 3000 4,60 88 200 -40..+50 IP 54 RP4)
❹ 400 2550 2600 4,02 89

Information
❶ 400 2040 2010 3,16 88
Centrifugal ❷ 400 2040 2560 3,96 85
B VBH0450NTTLS K3G450AQ23K1
module ❸ 400 2040 2780 4,30 84 200 -40..+60 IP 54 RP4)
❹ 400 2040 2295 3,57 86

❶ 400 1780 2160 3,37 89


Centrifugal ❷ 400 1780 2640 4,08 86
C VBH0500NTTLS K3G500AP28K1
module ❸ 400 1780 3000 4,60 84 200 -40..+55 IP 54 RP4)
❹ 400 1780 2680 4,14 84

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 113

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 113 28.09.2020 11:58:30


RadiPac 400

A VBH0400NTTLS K3G400AQ27K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm

500 533±3
450 518±3 441
Ø370 251
6 10
X
45.5

Ø11 (8x)
Y

10

9 8 1 7 (9x)
420 11
Y 3
4 M20x1.5 (2x)

Z X
2
EC centrifugal fans - RadiPac · Edition 2020-08

M20x1.5 (2x)
Z

1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture

114 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 114 28.09.2020 11:58:31


RadiPac 450

B VBH0450NTTLS K3G450AQ23K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm

630 562±3
580 547±3 441
Ø470 251 15
6 10

60.5 X

Ø11 (8x)
Y
725

10

Information
9 8 1 7 (9x)
492 11

Y 3
4 M20x1.5 (2x)
Z X

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


2
M20x1.5 (2x)
Z

1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)

Accesories
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture

Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 115

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 115 28.09.2020 11:58:32


RadiPac 500

C VBH0500NTTLS K3G500AP28K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm

630 574±3
580 559±3 441
Ø470 251
6 10

60.5 X

Ø11 (8x)
Y

10

9 8 1 7 (9x)
492 11

Y 3
4 M20x1.5 (2x)

X
EC centrifugal fans - RadiPac · Edition 2020-08

Z 2
M20x1.5 (2x)
Z

1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture

116 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 116 28.09.2020 11:58:33


RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 117
EC centrifugal fans - RadiPac · Edition 2020-08
117

28.09.2020 11:58:33
EC centrifugal fans - RadiPac · Edition 2020-08

Contacts Technology Accesories EC centrifugal fans - RadiPac · Edition 2020-08 Information


Ventilating large buildings efficiently – with ready-to-install RadiPacs. (Air) resistance is futile:
Special challenges call for special fans. To provide a reliable solution for AHU users looking to ventilate and air-condition large
buildings, ebm-papst has improved and optimized its popular RadiPac series to meet their special requirements.
The result: high-performance centrifugal fans with a static pressure increase of up to 2.500 Pa and air flow of up to 15.000 m³/h
and available in sizes 355, 400, 560 and 630. Of course, you also benefit from the many other advantages offered by this fan line,
including high reliability, energy-efficiency and compactness. And the robust cube design is again available as an option. Just
install, connect with plug & play, and turn up the pressure.

Long paths and other


obstacles.

Air-handling units for lar-


ge buildings like airports,
skyscrapers or hotels face
a special challenge: Since
residential and commer-
cial space is becoming
External Internal
increasingly expensive,
pressure pressure
centralized and space-
elements elements
saving solutions are gene-
rally preferred.

That means the air has to


be moved over long dis-
tances through external
pressure elements and
long air ducts to reach its
destination – past many
corners and junctions on
its way to the outlets.

Things get even more dif-


ficult when it has to over-
come additional obstacles
such as activated carbon
filters, heat exchangers
and separators (internal
pressure losses), because
they also affect the requi-
red pressure increase.

For all such cares, fans


with particularly high
statistic pressure increase Various Heat
are needed – and they filters exchangers
should be compact,
efficient and reliable.

118 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 118 28.09.2020 11:58:35


RadiPac 355 - 630
with high static pressure

the engineer’s choice


Page

Tender specification 120

Information
355 - 630 122

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 119

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 119 28.09.2020 11:58:35


Tender specification
EC centrifugal modules - RadiPac "High pressure"
with high static pressure
Fan size 355 to 630

Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics.

Impeller made of aluminum, with 5 backwards-curved, con- Any work required for isolation from structure-borne noise
tinuously welded, blades; flow-optimized inlet ring made of to be performed by the customer. Fan satisfies the applica-
galvanized sheet steel with pressure test nipple. ble EMC guidelines and requirements with regard to circuit
feedback (for specific information, see the respective data
Motor impeller statically and dynamically balanced on two
sheet). Documentation and marking conform to the appli-
planes to balancing grade G 6.3 (motor size 200 to balan-
cable EU Directives.
cing grade G 4.0) in accordance with DIN ISO 21940.
Reliable performance data, air performance measurements
EC centrifugal fans - RadiPac · Edition 2020-08

GreenTech EC external rotor motor surpasses efficiency


on intake-side chamber test rig according to ISO 5801 and
class IE4, magnets with no rare earths, maintenance-free
DIN 24163, noise measurements in anechoic rooms accor-
ball bearings with long-term lubrication, theoretical nomi-
ding to DIN EN ISO 3745.
nal service life of at least 40.000 hours of operation.
Integrated protective devices:
Soft start, integrated current limitation, respectively
- Alarm relay with zero-potential change-over contacts
3~380-480 V, 50/60 Hz. Fan can be used with all standard
(250 V AC, 2 A, cos φ = 1)
power supply networks with unaltered air performance.
- Locked-rotor protection
Integrated electronics, low-noise commutation logic;
- Phase failure detection
100 % open-loop speed control; all fans have an RS485/
- Soft start of motors
MODBUS RTU interface, and do not need to be installed
- Mains under-voltage detection
with shielded cables.
- Thermal overload protection for electronics and motor
Terminal box made of aluminum with easily accessible - Short circuit protection
connection area, environment-resistant cable glands.
Optional:
Version for wall mounting:
- Other and specific requirements on request
Support bracket, sizes 355 and 400 with size 150 motor as
- FlowGrid air inlet grill:
ready-to-install support bracket intended for wall moun-
FlowGrid air inlet grill tailor-made for the fan, to re-
ting. Support bracket made of bent round bar steel or
duce assembly and system-related noise. Grill made of
round tube, welded and coated in black. Mounting plate
high-grade composite material in one piece, available
and inlet ring made of sendzimir galvanized sheet steel.
ready for installation and also suitable for retrofitting.
Version for floor mounting: Ideal solution for confined intake conditions at the fan
Cube design, sizes 560 and 630 with size 200 motor as and/or if upstream turbulence-inducing fittings are
ready-to-install cube design intended exclusively for floor unavoidable. The FlowGrid breaks up the turbulence
mounting. Struts made of extruded aluminum sections fields and straightens the flow, resulting in distinct noise
connected to die-cast corner plates, nozzle plate and inlet reduction.
ring made of sendzimir galvanized sheet steel, motor
mounting plate made of coated sheet steel. This version is
not suitable for wall mounting.

120 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 120 28.09.2020 11:58:36


Tender specification
EC centrifugal modules - RadiPac "High pressure"
with high static pressure
Fan size 355 to 630

Technical data:

Fan type = K3G__ __ __ - __ __ __ __ - __ __

Information
Air flow qV = _________________________________ m3/h, cfm

Stat. pressure increase pfs = _________________________________ Pa, in wg

Stat. overall efficiency es = _________________________________ %

Operating speed n = _________________________________ rpm

Motor type = EC motor

Type of control = 0-100 % speed control

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Motor efficiency class = IE4

Total power input Ped = _________________________________ kW

Specific fan power SFP = _________________________________ kW/(m3/s)

Nominal voltage range UN = _________________________________ V

Line frequency f = 50 / 60 Hz

Nominal current IN = _________________________________ A

Degree of protection = IP55

Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)

Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)

Perm. ambient temperature T = _______________ to _______________ °C

Accesories
Weight of fan m = _________________________________ kg

Technology
Contacts

EC centrifugal fans - RadiPac EC centrifugal fans - RadiPac Optional


Support bracket Cube design Air inlet grill Flow Grid
Fan size 355 - 400 Fan size 560 - 630

Refer to data sheet for dimensions and wiring.

EC centrifugal fans - RadiPac · Edition 2020-08 121

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 121 28.09.2020 11:58:37


RadiPac 355 - 630
EC centrifugal modules with high static pressure

Material/surface
■ Support bracket (355,400): Steel, painted black
■ Support plate (355,400): Sheet steel,
galvanized
■ Support structure(560,630): Sheet steel,
galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades (355,400): 5
■ Number of blades (560): 6
■ Number of blades (630): 7
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 124 Drawings


■ Direction of rotation: Clockwise viewed toward
on Page 152 Accesories rotor
on Page 164 Connection diagrams and technical features ■ Installation position: See product drawing
on Page 180 Technical parameters & scope ■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Mounting: Maintenance-free ball bearings
Further Information
in. wg
Pa

■ Information about touch current, electrical


4 3 =max. connection, degree of protection, insulation
2500 4
10

class, environmental protection class, EMC


4
4 standards as well as standards and approvals
can be found in the product-specific data
sheets.
2000 3 3 3
8

3
1500
6

1000 2 2 2
4

500 B
2

A C

1 1 1 1
pfs

0 2000 4000 6000 8000 10000 12000 cfm

qv 4000 8000 12000 16000 20000 24000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

122 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 122 28.09.2020 11:58:39


RadiPac 355 - 630

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

❶ 400 4100 2895 4,56 100


Support ❷ 400 4100 3945 6,13 95
A VBH0355NTTLS K3G355HA3401
bracket ❸ 400 4100 4700 7,20 93 -40..+50 IP 55 RP9)
❹ 400 4100 4480 6,89 99

Information
❶ 400 3700 3460 5,35 102
Support ❷ 400 3700 4915 7,50 97
B VBH400NTTPS K3G400HB4101
bracket ❸ 400 3700 6000 9,10 94 -40..+40 IP 55 RP9)
❹ 400 3700 5660 8,62 95

❶ 400 2600 7350 11,65 105


❷ 400 2600 10565 16,37 98
C VBF0560NTVQS K3G560HE0701 Cube
❸ 400 2600 12000 18,70 95 -25..+45 IP 55 RP1)
❹ 400 2600 11485 17,72 99

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


❶ 400 2200 8680 13,55 107
❷ 400 2200 12000 18,49 100
D VBF0630NTVTS K3G630AT0911 Cube
❸ 400 2200 13750 21,00 94 -40..+40 IP 55 RP1)
❹ 400 2200 12350 18,92 99

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 123

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 123 28.09.2020 11:58:39


RadiPac 355

A VBH0355NTTLS K3G355HA3401 (EC centrifugal module with support bracket) Dimensions in mm

6 (4x)

4
1

Ø11 (4x)
M25x1.5

5
Ø345 1 M20x1.5 (2x) 2
15 3
275.1±2 421
388.6±3 450
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08

or Rotor on bottom, rotor on top on request


2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 148)
6 Mounting holes: for FlowGrid

124 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 124 28.09.2020 11:58:40


RadiPac 400

B VBH0400NTTPS K3G400NTTPS (EC centrifugal module with support bracket) Dimensions in mm

6 4x90°
Ø9 (4x) 35

1
4

Ø455

Ø11 (4x)

Information
M25x1.5

5 3
Ø440 15 M20x1.5 (2x) 2
323.8±2.5 450
437.3±3 492
500

1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 188))
6 Mounting holes: for FlowGrid

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 125

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 125 28.09.2020 11:58:40


RadiPac 560

C VBF0560NTVQS K3G560HE0701 (EC centrifugal module with cube design) Dimensions in mm

247
5
2
M10 (4x)

M25x1.5

224
4

586
3
4x90° M20x1.5 (2x)
6 Ø10 (4x) 45° 7
Ø545
250

1
Ø9.5 (12x)

1
EC centrifugal fans - RadiPac · Edition 2020-08

1 250 40
566 422
670 561

1 Inlet ring: with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

126 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 126 28.09.2020 11:58:42


RadiPac 630

D VBF0630NTVTS K3G630AT0911 (EC centrifugal module with cube design) Dimensions in mm

228
2
5
M10 (4x)

327
4 M25x1.5
676 M20x1.5 (2x)
3

Information
4x90°
6 Ø10 (4x) 45° 7
Ø545

1
Ø9.5 (12x)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


250 40
666 546
760 685

1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 127

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 127 28.09.2020 11:58:43


Atmosphère Explosive
The European guideline on explosion protection

Certified safety.: ATEX fans:


ebm-papst’s ex-protected fans are based on the proven RadiPac centrifugal fans for use in potentially ex-
3 kW GreenTech EC external rotor motor and are tes- plosive atmospheres.
ted and certified in line with the European product di-
rective 2014/34/EU. They therefore meet all demands These fans are available in sizes 400 to 630.
made of devices used in areas at risk of explosion.
The ecentrifugal ex-protected fans are suitable for The combination of high-efficiency EC motor and integ-
equipment group II (explosion-protected areas outside rated control electronics for use in potentially explosive
mining) and the gases and vapours substance group in atmospheres of Zones 1 and 2 is unique and simplifies
explosion group IIB. The ex-protected fans can be used the use of high-efficiency fans in such environments for
in hazard zones 1 and 2. They therefore correspond to the operator.
category 2G (ATEX) and have the equipment protec-
tion level Gb (EN 60079-0). As per the ATEX 1999/92/EC
operating directive, the facility operator is responsible
for the categorisation of hazard zones. The correspon-
ding equipment categorisation is performed by the
manufacturer, i. e. ebm-papst.

Ex marking of the ebm-papst fans as per ATEX and EN 60079-0::


Zündschutzarten
Escape of gases,
Temperature classes
Equipment category

fog and vapours


Pressure-resistant

(e.g. ammonia, methane,


Increased safety

Explosion group
Protection level

Protection level

Protection level

protection level
Intrinsic safety

ethane, propane, town gas,


Ex marking

Equipment

acrylonitrile, hydrogen
enclosure

sulphide, ethyl ether,


Group

acetaldehyde)

3G ic IIA T1 Gc
Zone 2
Corresponding T2 Increased
Hardly ever, rarely
to Zone 2 protection

Zone 1
II 2G Ex db eb ib IIB T3 Gb Occasionally

Required customer Required customer


specification specification

The following requirements are not covered:

I 1G ia IIC T4 Ga
Not available

Zone 0
Corresponding T5 Very high
Constantly, often
to Zone 0 T6 protection

128 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 128 28.09.2020 11:58:45


RadiPac 400 - 630
ATEX execution

the engineer’s choice


Page

400 - 630 130

Information
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 129

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 129 28.09.2020 11:58:45


RadiPac 400 - 630
EC centrifugal fans, backward curved (ATEX execution)

Material/surface
■ Support structure: Sheet steel, galvanized
■ Inlet ring: Sheet aluminium
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium,
painted black
Mechanical characteristics
■ Number of blades: 7
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 132 Drawings


■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa

A sheets.
3 =max.

1400
4

1200 B

4 3
1000 4
C
4

3
4
800 D
3

4 3
600 2
E 3
2
2

400 2 2
2
200

1 1 1 1 1
pfs

0 2000 4000 6000 8000 10000 cfm

qv 2000 4000 6000 8000 10000 12000 14000 16000 18000 m³/h
Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

130 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 130 28.09.2020 11:58:47


RadiPac 400 - 630 (ATEX)

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Centrifugal
--- ---
fan ❶ 400 2550 2035 3,11 92
❷ 400 2550 2715 4,14 88
A ❸ 400 2550 3100 4,70 86 -40..+50 IP 44 RP6)

VBF0400NTTLS K3G400AQ2390 Cube


❹ 400 2550 2900 4,40 88

Information
Centrifugal
--- ---
fan ❶ 400 2040 1840 2,82 92
❷ 400 2040 2685 3,92 88
B ❸ 400 2040 2950 4,50 86 -40..+50 IP 44 RP6)

VBF0450NTTLS K3G450AQ2490 Cube


❹ 400 2040 2605 3,93 87

Centrifugal
--- ---
fan ❶ 400 1780 2010 3,03 94
❷ 400 1780 2640 3,95 87
C ❸ 400 1780 2970 4,50 83 -40..+50 IP 44 RP6)

VBF0500NTTLS K3G500AP2590 Cube


❹ 400 1780 2750 3,91 85

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Centrifugal
--- ---
fan ❶ 400 1500 1905 2,96 93
❷ 400 1500 2570 3,95 89
D ❸ 400 1500 2940 4,50 86 -40..+50 IP 44 RP6)

VBF0560NTTPS K3G560AP2390 Cube


❹ 400 1500 2545 3,91 86

Centrifugal
--- ---
fan ❶ 400 1130 1895 2,93 90
❷ 400 1130 2515 3,87 84
E ❸ 400 1130 2970 4,60 83 -40..+50 IP 44 RP6)

VBF0630NTTRS K3G630AP0190 Cube


❹ 400 1130 2545 3,93 82

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 131

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 131 28.09.2020 11:58:48


RadiPac 400 (ATEX)

A VBF0400NTTLS K3G400AQ2390 (EC centrifugal module with cube design) Dimensions in mm

B-B

95.8
6 M4x20 (7x)

2.82
330.6
8 2.82
2 9
M25x1.5
Ø9 (4x)

3
X
4 M20x1.5
5
435 7 (2x)

1
10
Ø9 (4x)
EC centrifugal fans - RadiPac · Edition 2020-08

B
X
434 15
500 333.4
466

1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian

132 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 132 28.09.2020 11:58:49


RadiPac 450 (ATEX)

B VBF0450NTTLS K3G450AQ2490 (EC centrifugal module with cube design) Dimensions in mm

103.1
B-B 6 M4x20 (7x)

3.17
357
2
8 3.17
Ø9 (4x)

9
M25x1.5 3 M20x1.5
X
4
565 5

Information
7 (2x)

1
10
Ø9 (4x)

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


B
X

519 15
630 367.1
500

1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut

Accesories
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian

Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 133

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 133 28.09.2020 11:58:49


RadiPac 500 (ATEX)

C VBF0500NTTLS K3G500AP2590 (EC centrifugal module with cube design) Dimensions in mm

B-B

105.9
6 M4x20 (7x)

3.53
2

369
8 3.53
Ø9 (4x)

9
M25x1.5 M20x1.5

X 3
565 4
5
7 (2x)

B
1
10
Ø9 (4x)
EC centrifugal fans - RadiPac · Edition 2020-08

B
X
519 15
630 381.9
514

1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian

134 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 134 28.09.2020 11:58:50


RadiPac 560 (ATEX)

D VBF0560NTTPS K3G560AP2390 (EC centrifugal module with cube design) Dimensions in mm

B-B

196.1
6 M4x20 (7x)

3.95
2

258.5
8 3.95
Ø9 (4x)

M25x1.5 3 M20x1.5
X
688 4

Information
5
7 (2x)

1
10

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Ø9 (4x)

X
689 15
760 425.35
561

1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut

Accesories
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian

Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 135

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 135 28.09.2020 11:58:51


RadiPac 630 (ATEX)

E VBF0630NTTRS K3G630AP0190 (EC centrifugal module with cube design) Dimensions in mm

B-B

243.45
6 M4x20 (7x)

4.44
2 8 4.44

339.5
9
Ø9 (4x)

M25x1.5 3 M20x1.5
X 4
688 5
7 (2x)

1
10
EC centrifugal fans - RadiPac · Edition 2020-08

Ø9 (4x)

B
X

689 15
760 553.7
689

1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian

136 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 136 28.09.2020 11:58:52


RadiPac 630 (ATEX)

Information
EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 137

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 137 28.09.2020 11:58:52


EC centrifugal fans RadiFit:
Compact, efficient, easily upgraded. Our RadiFit range of centrifugal fans with scroll housing and backward-curved blades is the
new system solution for many applications in industry and ventilation technology.
Thanks to the highly efficient GreenTech EC motors, it offers high efficiency at high pressures. They are also extremely compact,
robust and light. Best of all, RadiFit fans match the standard installation dimensions for fans.
This makes installing and replacing them child’s play. Fits, saves and makes sense!

Retrofit: replace with highly


efficient technology.

Energy efficiency means lower


operating costs.

Our centrifugal fans with Green-


Tech EC technology are so much
more advanced than normal fans,
that even retrofitting existing units
quickly pays for itself. Furthermore,
our new range has a particularly
long service life and requires no
maintenance at all, which results
in further cuts to operating and life
cycle costs.

Finally, we deliver the fans comple-


te with housing and installed cont-
rolled electronics (VSD). This also
reduces your installation costs to a
minimum.

Comparing this to an obsolete belt


drive and a flange-mounted motor
makes the difference clear to see.
Instead of connecting multiple
components to each other at great
effort and expense, RadiFit has
everything integrated already,
combined with minimal size and
maximum energy efficiency.

Typical applications in air


conditioning:
- Low profile air conditioning unit
with RadiFit 250
- Central air handling unit with
RadiFit 400

Typical industrial implementation:


- Generator cooling with RadiFit 310

138 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 138 28.09.2020 11:58:55


RadiFit 250 - 400

the engineer’s choice


Page

Tender specification 140

Information
250 - 400 142

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 139

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 139 28.09.2020 11:58:56


Tender specification
EC centrifugal fans - RadiFit
Fan size 250 to 400

Direct-drive dual-inlet centrifugal fans with backward-curved high-performance centrifugal impellers mounted on a
GreenTech EC external rotor motor with add-on control electronics.

Scroll housing made of galvanised sheet steel with bolted Fan satisfies the relevant EMC regulations and require-
-on adjustable mounting bracket, optimised step diffuser ments with regard to circuit feedback; documentation and
in discharge for low-noise operation, connection flange on marking conform to the applicable EU directives
pressure side.
Reliable performance data, air performance measurements
on inlet-side chamber test rig in accordance with ISO 5801
Aluminium impeller with 7 backward-curved, offset, conti-
and DIN 24163, noise measurements in low-reflection
nuously welded blades. Flow-optimised inlet nozzle made
acoustic test chamber as per DIN EN ISO 3745.
of galvanised sheet steel.
EC centrifugal fans - RadiPac · Edition 2020-08

Integrated protective devices:


Motorised impeller balanced in two planes (static and dy- - Alarm relay with floating contacts
namic) as per DIN ISO 21940 to balance quality G 6.3. (250 V AC/2 A, cos φ = 1)
- Locked-rotor protection
GreenTech EC external rotor motor surpasses efficiency - Phase failure detection
class IE4, magnets without use of rare earths, maintenan- - Motor soft start
ce-free ball bearings with long-term lubrication, theoretical - Mains undervoltage detection
nominal service life of at least 40.000 operating hours, - Excess temperature protection for electronics and motor
soft start, integrated current limitation, wide input voltage - Short circuit protection
range 3-phase 380-480 V, 50/60 Hz, fan suitable for use
with all standard power supply systems with no effect on Optional:
air performance. - Different requirements on request

Motorised impeller isolated from surroundings with spe-


cially designed vibration-absorbing elements, compact
electronics, aluminium housing, low-noise commutation
logic; 100% speed control; PID controller; RS485/MODBUS
RTU interface, no need for shielded wiring.

Readily accessible connection area with spring terminals,


cable entry can be moved through 180 degrees, environ-
ment-resistant cable glands.

140 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 140 28.09.2020 11:58:56


Tender specification
EC centrifugal fans - RadiFit
Fan size 250 to 400

Technical data:

Fan type = D3G__ __ __ - __ __ __ __ - __ __

Information
Air flow qV = _________________________________ m3/h, cfm

Stat. pressure increase pfs = _________________________________ Pa, in wg

Stat. overall efficiency es = _________________________________ %

Operating speed n = _________________________________ rpm

Motor type = EC motor

Type of control = 0-100 % speed control

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Motor efficiency class = IE4

Total power input Ped = _________________________________ kW

Specific fan power SFP = _________________________________ kW/(m3/s)

Nominal voltage range UN = _________________________________ V

Line frequency f = 50 / 60 Hz

Nominal current IN = _________________________________ A

Degree of protection = IP54

Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)

Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)

Perm. ambient temperature T = _______________ to _______________ °C

Accesories
Weight of fan m = _________________________________ kg

Technology
Contacts

EC centrifugal fans - RadiFit


With scroll housing
Fan size 250 - 400

Refer to data sheet for dimensions and wiring.

EC centrifugal fans - RadiPac · Edition 2020-08 141

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 141 28.09.2020 11:58:56


RadiFit 250 - 400
EC centrifugal fans, backward curved, with housing

Material/surface
■ Housing: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Motor suspension: Motor mounted with
brackets on one side
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
■ Mounting: Maintenance-free ball bearings
EC centrifugal fans - RadiPac · Edition 2020-08

on Page 144 Drawings


on Page 152 Accesories Further Information
on Page 164 Connection diagrams and technical features ■ Information about touch current, electrical
on Page 180 Technical parameters & scope connection, degree of protection, insulation
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
sheets.
in. wg
Pa

3 =max.
1600
6

1400 4

1200 4
4
1000 3
4

4
800 3 4
3

600 3 3
2
2

400 2 2
2 2
200
E
B
A C D
1 1 1 1 1
pfs

0 1000 2000 3000 4000 5000 6000 7000 cfm

qv 2000 4000 6000 8000 10000 12000 m³/h


Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.

142 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 142 28.09.2020 11:59:00


RadiFit 250 - 400

Degree of protection
Sound power level
Nominal voltage
Operating point

Conn. diagram
Max. Input

Max. Input
power Ped

current I

ambient
Speed n

temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type

Moun-
VCD0250FTPMS D3G250GG0901 RadiFit ting ❶ 400 3850 1610 2,57 96
bracket
❷ 400 3850 1765 2,79 94
A ❸ 400 3850 1810 2,90 91 -25..+40 IP 54 RP8)

--- --- ❹ 400 3850 1720 2,73 89

Information
Moun-
VCD0280FTPMS D3G280GG1001 RadiFit ting ❶ 400 2900 1190 1,98 92
bracket
❷ 400 2900 1295 2,10 89
B ❸ 400 2900 1320 2,10 86 -40..+40 IP 54 RP8)

--- --- ❹ 400 2900 1190 1,98 85

Moun-
VCD0310FTRNS D3G310GG0501 RadiFit ting ❶ 400 3140 2825 4,35 97
bracket
❷ 400 3140 3095 4,74 95
C ❸ 400 3140 3180 4,90 91 -25..+40 IP 54 RP8)
Moun- ❹ 400 3140 2810 4,32 90
VCD0310FTRNS D3G310GG0504 RadiFit ting
frame

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Moun-
VCD0355FTRNS D3G355GG0301 RadiFit ting ❶ 400 2600 2980 4,59 95
bracket
❷ 400 2600 3160 4,90 93
D ❸ 400 2600 3160 4,90 91 -25..+40 IP 54 RP8)
Moun- ❹ 400 2600 3040 4,68 89
VCD0355FTRNS D3G355GG0304 RadiFit ting
frame

Moun-
VCD0400FTRNS D3G400GG0401 RadiFit ting ❶ 400 1920 2170 3,39 91
bracket
❷ 400 1920 2380 3,70 88
E ❸ 400 1920 2380 3,70 85 -25..+40 IP 54 RP8)
Moun- ❹ 400 1920 2160 3,38 84
VCD0400FTRNS D3G400GG0404 RadiFit ting
frame

Subject to change Values set in blue are nominal data at operating point with maximum load.

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 143

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 143 28.09.2020 11:59:00


RadiFit 250

A VCD0250FTPMS D3G250GG0901 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm

140 140
352
347

10.5
Ø7
14

224
310 12
M20x1.5 (2x) 3

432 379
205 352
4 Ø7.5(12x) Ø9

1
322

161
X

322

381
107
EC centrifugal fans - RadiPac · Edition 2020-08

489

Ø166
X
4
220

180

326
376

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 134) on both sides

144 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 144 28.09.2020 11:59:01


RadiFit 280

B VCD0280FTPMS D3G280GG1001 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm

140 140
386.5
391

10.5
14.5 Ø7

224 12

Information
M20x1.5(2x) 3
310
475 418
225 391
4 Ø7.5(12x) Ø9

181.3
361
X

362.6

419.6
121.5

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Ø187.2
546

X
4
243

180

365
415

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 175) on both sides

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 145

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 145 28.09.2020 11:59:02


RadiFit 310

C VCD0310FTRNS D3G310GG0501 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm

2
440.2
(220.1)

8.5

14
280
12.65

355 M20x1.5 (2x) 3


380
529 461.5
246 434
4 Ø9 Ø7.5 (16x)

1 404

202
X

463
404
138
EC centrifugal fans - RadiPac · Edition 2020-08

600

Ø212
X 4
258

90

270
408.5
465.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 206) on both sides

146 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 146 28.09.2020 11:59:04


RadiFit 310

C VCD0310FTRNS D3G310GG0504 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm

2
437.6
(218.8)

Ø10.5

280 106
15.25

Information
492 M20x1.5 (2x) 3

531 461.5
246 434
4 Ø9 Ø7.5 (16x)

1
404

202
X

463
404
138
578

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


X Ø212
4
235

90

270
408.5
468.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 206) on both sides

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 147

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 147 28.09.2020 11:59:04


RadiFit 355

D VCD0355FTRNS D3G355GG0301 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm

2
489.2
(244.6)

14 8.5

280
12.65

355
380 M20x1.5 (2x) 3

592 510.5
271 483
4 Ø9 Ø7.5(16x)

1 453

226.5
X

512
453
156
670
EC centrifugal fans - RadiPac · Edition 2020-08

Ø239
X
4
287

90

270
457.5
514.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 277) on both sides

148 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 148 28.09.2020 11:59:06


RadiFit 355

D VCD0355FTRNS D3G355GG0304 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm

2
495.6
(247.8)

Ø10.5
10.75

355 97
549

Information
M20x1.5 (2x) 3

593 510.5
271 483
4 Ø9 Ø7.5(16x)

1 453

226
X

511.6
453
156
656

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Ø239
X
4
267

90

270
457.5
517.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 277) on both sides

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 149

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 149 28.09.2020 11:59:06


RadiFit 400

E VCD0400FTRNS D3G400GG0401 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm

2
543
271.5

190 8.5

14
280
12.65

M20x1.5 (2x)
355
3
110 380
655 564.5
300 537
4 Ø9 Ø7.5 (20x)

253.5
507
X

565.6
507
178
750.2
EC centrifugal fans - RadiPac · Edition 2020-08

Ø271
X 4
318

180

360
511.5
568.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 355) on both sides

150 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 150 28.09.2020 11:59:07


RadiFit 400

E VCD0400FTRNS D3G400GG0404 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm

2
550.6
275.3

Ø10.5

Information
355 129.5 M20x1.5 (2x)
10.25

614 3
662 564.5
300 537
4 Ø9 Ø7.5 (20x)

1 507

253.5

565.6
X

507
178
738

EC centrifugal fans - RadiPac · Edition 2020-08

EC centrifugal fans - RadiPac · Edition 2020-08


Ø271
X
4
301

180

360
511.5
571.5

1 Tightening torque: 3.5 ± 0.5 Nm Installation position: Shaft horizontal or


2 Terminal box: Pin assignment see connection diagram rotor on bottom, rotor on top on request
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm,
4 Inlet ring: with pressure tap (k-factor: 355) on both sides

Accesories
Technology
Contacts

EC centrifugal fans - RadiPac · Edition 2020-08 151

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 151 28.09.2020 11:59:08


152 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 152 28.09.2020 11:59:10


Accesories
for EC centrifugal fans - RadiPac

the engineer’s choice


Page

FlowGrid air inlet grill 154

Intake finger guard 155

Inlet rings 156

Vibration absorbers 160

Accesories

EC centrifugal fans - RadiPac · Edition 2020-08 153

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 153 28.09.2020 11:59:10


FlowGrid air inlet grill
efficient noise reduction

ebm-papst fans are not measured on our own advan-


ced test stands just for their air performance alone.
Information

The acoustic behavior of the fans is also examined


and the measurement results are included in the
technical documentation.

Please note that the measurements are taken under


ideal conditions with undisturbed inflow and out-
flow. If the fans are subsequently installed and used
in devices with rather tight spaces, it is to be expec-
ted that the noise data provided in the documentati-
on will not be applicable.
EC centrifugal fans - RadiPac · Edition 2020-08

FlowGrid air inlet grill In order to minimize the negative impact of the
ØB ØC ØE S H N* installation situation, ebm-papst offers the FlowGrid
Part number Fan size (mm) (mm) (mm) (mm) (mm) (Nm) air-inlet guard shown here. It is installed on the intake
20280-2-2957 250, 280 280 245-261 4,5 3,5 40 2±0,5 side of the fan and effectively reduces the noise
25310-2-2957 310 315 288-292 5,5 3,5 49 2±0,5 generated by the fan. Particularly annoying, low-fre-
00400-2-2957 355 370 334-346 4,5 3,5 56 2±0,5 quency noises are reduced efficiently.
35505-2-2957 400, 450, 500 470 440 9,0 3,5 71 10±2
00630-2-2957 560, 630 580 545 10 3,0 90 10±2
The level of noise reduction is dependent on the
50710-2-2957 710 666 630 10 3,0 106 10±2
installation situation, which is why no generally
63000-2-2957 800 785 750 10 3,0 125 10±2
applicable data is possible here.
Subject to change * Recommended tightening torque for fastening screws

Would you like


to find out more?

If you need an
installation guide
Accesories

or more information
about the dimensions,
go to:

www.ebmpapst.com
Technology

/flowgrid-manual

or scan the
QR code below:
Contacts

E S
ØC H
ØB

154 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 154 28.09.2020 11:59:15


Intake fi nger guard
Wire mesh finger guard

– Material: Steel wire, phosphated,


Versions 1 and 2:
Painted pebble gray (RAL 7032)
Versions 3 and 4:
Painted light gray (RAL 7035)

Intake finger guard for backwards-curved centrifugal fans (according to EN ISO 13857)
a b d e
Part number Fan size Version Strut division
(mm) (mm) (mm) (mm)
79280-2-4039 250,280 1 280 4,5 227 2,8 4 x 90°
79310-2-4039 310 1 325 4,5 271 2,8 4 x 90°
79355-2-4039 355 1 345 4,5 308 2,8 4 x 90°
79400-2-4039 400 2 390 8,5 343 2,8 3 x 120°
79500-2-4039 450,500 2 445 8,5 417 2,8 3 x 120°
79560-2-4039 560 2 490 8,5 466 2,8 3 x 120°
79630-2-4039 630 3 600 8,5 551 3,9 3 x 120°
79710-2-4039 710, 800 3 700 8,5 651 3,9 3 x 120°
79900-2-4039 1000 4 850 8,5 801 3,9 6 x 60°
Subject to change
e b
b

Version 1 Version 2

Accesories

e
Ød Ød
Øa Øa

e b
b

Version 3 Version 4

e
Ød Ød
Øa Øa

EC centrifugal fans - RadiPac · Edition 2020-08 155

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 155 28.09.2020 11:59:18


Inlet rings
with / without measuring device

– Material: Galvanized sheet steel


Information
EC centrifugal fans - RadiPac · Edition 2020-08

Inlet rings with / without measuring device to determine the air flow for backwards-curved centrifugal fans
Part number Part number Part number
Fan size Dimensions / drawing
without measuring device with one pressure tap with piezometer
96350-2-4013 96355-2-4013 96345-2-4013 250 see Page 157
28000-2-4013 28004-2-4013 28003-2-4013 280 see Page 157
31470-2-4013 31475-2-4013 31480-2-4013 310 see Page 157
35670-2-4013 35675-2-4013 35680-2-4013 355 see Page 157
40073-2-4013 40078-2-4013 40083-2-4013 400 see Page 158
45070-2-4013 45075-2-4013 45080-2-4013 450 see Page 158
63072-2-4013 64025-2-4013 64002-2-4013 500 see Page 158
63071-2-4013 64030-2-4013 64001-2-4013 560 see Page 158
63070-2-4013 64040-2-4013 64000-2-4013 630 see Page 159
71070-2-4013 71075-2-4013 71080-2-4013 710 see Page 159
80070-2-4013 80075-2-4013 80080-2-4013 800 see Page 159
Subject to change

without with one


measuring device: pressure tap:
Accesories

with
piezometer:
Technology
Contacts

156 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 156 28.09.2020 11:59:22


Inlet rings
Dimensioned drawings with one pressure tap

Fan size 250: 6x60° Fan size 280:


15°
Ø4.5 (4x) Ø4,5
Ø4,5
Ø5 (6x)

0°°
x990
44x
RR11
77
R1

R3333

RR53
8
R 55.5

53
R35

R
Ø167.25

Ø176,7
Ø176,7
Ø161.3

Ø182
Ø182

Ø280
Ø280
Ø280

1.5 Ø250 1,25


1,25 Ø260
Ø260
48 Ø260 46
46

Fan size 310: Fan size 355:


Ø4,5 Ø4,5
Ø4,5

Accesories
R2
R

4
20

R 47

R74,5
R 58

R 63,5

,5
Ø211,7
Ø217

Ø350

Ø370
Ø246
Ø239

1,5 Ø290 1,5 Ø345


54,8 Ø325 64,4

EC centrifugal fans - RadiPac · Edition 2020-08 157

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 157 28.09.2020 11:59:23


Inlet rings
Dimensioned drawings with one pressure tap
Information

Fan size 400: 6x60° Fan size 450:


6x6
30° 9 45° 0°
Ø4,5(6x)
Ø10(4x)
Ø9(6x)
R2

R2
5,5
R 49,5

8
R 55
R 78,5

R 87,5
)
3x
2(
39

4x90°
Ø303,4
Ø270,9

6x60°
Ø396

Ø480
Ø312
Ø278
EC centrifugal fans - RadiPac · Edition 2020-08

1,5 Ø376 2 Ø430


67,7 75,6 Ø440
Ø460

4x90°
Fan size 500: Fan size 560:
x)
(4
Ø9

45° Ø9(6x)
° 0°
6x60 6x6
R3
R2

0
15

R 60

R 95
8

°
R 49

)
R 87
Accesories

(6x
Ø9

Ø388,8

Ø515
Ø380
Ø470
Ø346
Ø337

15°

505
Technology

2 Ø490
82

2 Ø440
75 Ø445
Contacts

158 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 158 28.09.2020 11:59:24


Inlet rings
Dimensioned drawings with one pressure tap

Fan size 630: Fan size 710: 15°


Ø10.5 (6x) 6x6
0° x)
Ø10 (4
Ø9
°
90

(6x
)
4x


4x9


R3

6x6
R 50.4

R4
7

R66.6
R355
R 114

7.9
R 72

Ø10 (4x)
15°

Ø492.6
Ø470.3

Ø720
Ø436.8
Ø427

Ø624

Ø545
2 Ø630
2 Ø600
117 Ø700
98.5

Fan size 800: 15°



6x6

Ø9 (6x)
R5
4

Accesories
R 75
R 56.8
R400

710
Ø555.3
Ø529.7

Ø720

2.5 Ø700
131

EC centrifugal fans - RadiPac · Edition 2020-08 159

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 159 28.09.2020 11:59:24


Vibration absorbers
for EC centrifugal fans - RadiPac
Information

M10 – Packaging:
Part numbers refer to one set consisting of 4x spring elements each.
Supplied in a box.

– For further information, see: Installation instructions no.: 45014-4-8670


*94

Vibration absorbers (steel)


Minimum speed Deflection
Part number (Set) Type (rpm) (mm)
EC centrifugal fans - RadiPac · Edition 2020-08

* Unloaded
M10

11064-4-5142 K3G 630-PV04-01 510 7,5


11065-4-5142 K3G 630-PW04-01 570 5,9
Ø70

11065-4-5142 K3G 710-PV05-01 530 6,5


11065-4-5142 K3G 710-PW06-01 490 7,8
11065-4-5142 K3G 800-PV13-01 500 7,4
11065-4-5142 K3G 800-PW07-01 480 8,0
11064-4-5142 K3G A00-PV03-01 370 13,8
Subject to change

M10 – Packaging:
Part numbers refer to one set consisting of 4x rubber buffers, washers, and nuts each.
Supplied in a box.
18

– For further information, see: Installation instructions no.: 45014-4-8670


Accesories

40

Vibration absorbers (rubber)


Minimum speed Deflection
Part number (Set) Type
T

(rpm) (mm)
M10
Technology

10005-4-5164 K3G 630-PV04-01 790 2,1


40
10005-4-5164 K3G 630-PW04-01 725 2,5
10005-4-5164 K3G 710-PV05-01 701 2,6
10005-4-5164 K3G 710-PW06-01 629 3,3
10005-4-5164 K3G 800-PV13-01 656 3,1
10005-4-5164 K3G 800-PW07-01 620 3,4
Contacts

10008-4-5164 K3G A00-PV03-01 496 5,3


Subject to change

160 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 160 28.09.2020 11:59:24


Vibration absorbers
for EC centrifugal fans - RadiPac

Attention:
The vibration absorbers recommended by ebm-papst are avai- The configuration of the unit in which the fan is installed can have
lable in a set of 4 pieces. The vibration absorbers are perfectly a strong influence on the fan‘s vibration characteristics, so
matched to their intended fans and the specified minimum speed. a vibration test always has to be performed after the fan has been
The installation and operation of several fans on one set of spring installed. The fan’s vibration characteristics must be tested under
elements is not allowed. all relevant operating conditions (such as speed, back pressure,
systemic fluctuations in back pressure) – when installed and in
During start-up, the fan has to pass through the speed range interaction with the complete system.
corresponding to the resonance frequency (below the minimum
speed). The vibrations caused by the fan’s residual imbalance are The maximum vibration severity may not exceed 3.5 mm/s, mea-
strongest within this speed range. This speed range must be pas- sured at the motor’s fastening pitch circle on the motor support
sed through as quickly as possible to avoid damage to the fan. plate in the direction of and perpendicular to the motor’s axis of
Operation below, close to or at the resonance frequency will rotation. Even when the vibration absorbers recommended by
destroy the fan! ebm-papst are used, their effectiveness must be tested in the
application. If vibration absorbers other than those specified are
When the fan is being operated, take care to ensure that the used, tests must be performed to determine how the resonance
fan’s speed does not go below the specified minimum speed. frequency, and thus the operating requirements, change.
This will prevent the fan from being operated continuously near
the resonance frequency. The specified minimum speed is always
for an individual fan without any influences from the system it is
installed in.

Installation example: Floor-mounted, shaft horizontal

Accesories

EC centrifugal fans - RadiPac · Edition 2020-08 161

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 161 28.09.2020 11:59:26


162 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 162 28.09.2020 11:59:30


Technology
for EC centrifugal fans - RadiPac

the engineer’s choice


Page

Conection diagrams 164

Effects of installation space 178

Air flow measurement 179

Technical parameters & scope 180

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 163

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 163 28.09.2020 11:59:30


Connection diagram: RP1)

Technical features:
• Control input 0-10 VDC / PWM • Locked-rotor protection / Soft start / Motor current limitation
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output 20 VDC (+/-20 %) max. 50 mA • PFC, passive (standard) or PFC, active (see product-specific catalog page)
• Output for slave 0-10 V max. 5 mA • Thermal overload protection for electronics/motor
• Input for sensor 0-10 V or 4-20 mA • Undervoltage/phase failure detection
• Operation and fault indicator • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)

KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain2 U

Ain2 I
+20V
GND

Aout
Din3
Din2

Ain1 U

Ain1 I
+10V

COM
GND
RS A

RS B

Din1

NO

NC

PE

L1

L2

L3
1 2 3 4 5 6 7 1 2 3 1 2 3

Terminal Pin Designation Assignment/function


KL1 1 L1 Power supply, phase, see nameplate for voltage range
2 L2 Power supply, phase, see nameplate for voltage range
3 L3 Power supply, phase, see nameplate for voltage range
PE PE Protective earth
KL2 1 NO Status relay, floating status contact, option 1: break for failure,
option 2: break for run monitoring error message
2 COM Status relay, floating status contact, common connection, contact rating 250 VAC / 2 A (AC1)
min. 10 mA, reinforced insulation on supply side and on control interface side
3 NC Status relay, floating status contact, option 1: make for failure,
option 2: make for run monitoring error message
KL3 1 RSA RS485 interface for MODBUS RSA, SELV
2 RSB RS485 interface for MODBUS RSB, SELV
3/10 GND Reference ground for control interface, SELV
4 Ain1 U / PWM Analog input 1 (set value); 0-10 V; Ri= 100 kΩ; adjustable curve;
Technology

only for use as alternative to input Ain1 I, SELV


5 +10V Voltage output, power supply for external devices (e.g. potentiometers), SELV
6 Ain1 I Analog input 1 (set value); 4-20 mA; Ri= 100 Ω; adjustable curve,
only for use as alternative to input Ain1 U, SELV
7 Din1 Digital input 1: Enable electronics; Enable: Pin open or applied voltage 5...50 VDC;
Disable: Bridge to GND or applied voltage < 1 VDC;
Reset function: Triggering of software reset after level change to < 1VDC, SELV
8 Din2 Digital input 2: Switching parameter sets 1/2, according to EEPROM setting,
the valid/used parameter set can be selected via bus or via digital input Din2.
Parameter set 1: Pin open or voltage 5-50 VDC;
Parameter set 2: Bridge to GND or applied voltage < 1 VDC, SELV

164 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 164 28.09.2020 11:59:31


Connection diagram: RP1)

Terminal Pin Designation Assignment/function


KL3 9 Din3 Digital input 3: Direction of action of integrated controller; According to EEPROM setting,
the direction of action of the integrated controller can be selected as normal/inverse via bus
or digital input; Normal: Pin open or applied voltage 5...50 VDC;
Inverse: Bridge or applied voltage < 1 VDC, SELV
11 Ain2 U Analog input 2; Measured value 0-10 V; Ri= 100 kΩ;
adjustable curve; only for use as alternative to input Ain2 I, SELV
12 +20V Voltage output, power supply for external devices (e.g. sensors), SELV
13 Ain2 I Analog input 2; Measured value 4-20 mA; Ri= 100 Ω;
adjustable curve, only for use as alternative to input Ain2 U, SELV
14 Aout Analog output 0-10 V; max. 5 mA; output of current motor modulation level/current motor
speed. Adjustable curve, SELV

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 165

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 165 28.09.2020 11:59:31


Connection diagram: RP2)

Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation / Alarm relay
• RS 485 MODBUS-RTU / PFC, passive • Undervoltage/phase failure detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator • External enable input/External 24 V input (parameterization)
• Integrated PI controller

KL 2 KL 1
5 6 7 8
Ain1 U
+10 V
Din1

NC
GND
RS A

RS B

PE

L1

L2

L3
C

1 2 3 4 1 2 3

Terminal Pin Designation Assignment/function


KL1 1 L1 Power supply, phase, see nameplate for voltage range
2 L2 Power supply, phase, see nameplate for voltage range
3 L3 Power supply, phase, see nameplate for voltage range
PE PE Protective earth
KL2 1 RSA RS485 interface for MODBUS RSA, SELV
2 RSB RS485 interface for MODBUS RSB, SELV
3 GND Reference ground for control interface; SELV
4 C Status relay, floating status contact, contact rating 250 VAC / 2 A (AC1) min. 10 mA,
reinforced insulation on supply side and on control interface side
5 Din1 Digital input 1 enable electronics, enable: pin open or applied voltage 5-50 VDC
disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 V; SELV
6 +10V Voltage output, power supply for external devices (e.g. potentiometers), SELV
or: +24 VDC input for parameter setting via MODBUS without line voltage
Technology

7 Ain1 U Analog input 1 (set value) 0-10 V, Ri = 100 kΩ, adjustable curve; SELV
8 NC Status relay, floating status contact, break for failure

166 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 166 28.09.2020 11:59:32


Connection diagram: RP3)

Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation
• RS 485 MODBUS-RTU / PFC, active • Undervoltage detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator
• Power limiter
• Alarm relay

Wire 1 Wire 2
0-10 V

+10 V
COM

GND
RSA
RSB
NC
PE

green/yellow blue black white 1 white 2 yellow brown white blue red

Wire Designation Color Assignment/function


1 PE green/yellow Protective earth
N blue Power supply, neutral conductor, voltage range see nameplate
L black Power supply, phase, voltage range see nameplate
NC white 1 Status relay, floating status contact, break for failure
COM white 2 Status relay, floating status contact, contact rating 250 VAC / 2 A (AC1) min. 10 mA,
basic insulation on supply side and reinforced insulation on control interface side
2 0-10 V / PWM yellow Control input 0-10 V or PWM, impedance 100 kΩ, SELV, adjustable curve
RSB brown RS485 interface for MODBUS, RSB, SELV
RSA white RS485 interface for für MODBUS, RSA, SELV
GND blue Reference ground for control interface, SELV
+10 V (max. 10 mA) red Voltage output, power supply for ext. devices (e.g. potentiometer), SELV

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 167

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 167 28.09.2020 11:59:33


Connection diagram: RP4)

Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation / Alarm relay
• RS 485 MODBUS-RTU / PFC, passive • Undervoltage/phase failure detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator • External 24 V input (parameterization)
• Integrated PI controller

Wire 1 Wire 2

24 V IN
0-10 V

+10 V
COM

GND

RSA

RSB
NC
PE

PE

L2
L1

L3

green/yell. green/yell. black black black white 1 white 2 blue white brown yellow red

Wire Designation Color Assignment/function


1 PE green/yellow Protective earth
L1 black Power supply, phase, see nameplate for voltage range
L2 black Power supply, phase, see nameplate for voltage range
L3 black Power supply, phase, see nameplate for voltage range
NC white 1 Status relay, floating status contact, break for failure
COM white 2 Status relay, floating status contact, contact rating 250 VAC / 2 A (AC1) min. 10 mA,
basic insulation on supply side and reinforced insulation on control interface side
2 GND blue basic insulation on supply side and reinforced insulation on control interface side
RSA white RS485 interface for MODBUS, RSA, SELV
RSB brown RS485 interface for MODBUS, RSB, SELV
0-10 V / PWM yellow Control input 0-10 V or PWM, impedance 100 kΩ, SELV, adjustable curve
+10 V red Voltage output, power supply for external devices (e.g. potentiometers), SELV
or: +24 VDC input for parameter setting via MODBUS without line voltage
Technology

168 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 168 28.09.2020 11:59:33


Connection diagram: RP5)

Technical features:
• Configurable inputs/outputs (I/O) • Voltage output 3,3-24 VDC, Pmax = 800 mW
• RFID - ISO 15693 compatible • RS 485 MODBUS-RTU / MODBUS V6
• Operation and fault indicator with LED • Thermal overload protection for electronics/motor
• Integrated PI controller • Undervoltage/phase failure detection
• Locked-rotor protection • Control interface with SELV potential safely disconnected from supply
• Soft start / Alarm relay • External 15-50 VDC input (parameterization)
• Motor current limitation

GND GND PE
L1
IO1 RSA LED
IO2 RSB L2

IO3 RSA PE
RFID L3
Vout RSB
CON1
NC COM
CON2

Terminal Designation Assignment/function


CON1 L1, L2, L3 Power supply, phase, see nameplate for voltage range
PE PE Protective earth
CON2 RSA RS485 interface for MODBUS, RSA, SELV
RSB RS485 interface for MODBUS, RSB, SELV
GND Reference ground for control interface, SELV
IO1 IN2: Digital input - positive logic (factory setting: Enable) function parameterizable, SELV
- normal: Pin open or applied voltage < 1,5 VDC
- inverse: applied voltage 3,5-50 VDC
IO2 IN1: Analog input 0-10 V; 0-10 V, Ri=100 K, parameterizable as set value or measured value (factory
setting: set value), characteristic curve parameterizable, SELV
IO3 OUT1: Analog output 0-10 V; 0-10 V, max 5 mA, function parameterizable (factory setting: modulation
lrvel) max output frequency 300 Hz, SELV
Vout Voltage output 3,3-24 VDC +/-5 %, Pmax=800 mW, voltage parameterizable (factory setting: 10 VDC)
short-circuitproof, supply for external devices, SELV
alternatively: 15-50 VDC input for parameterization via Modbus without line voltage
Technology

COM Status relay, floating status contact, contact rating 250 VAC / 2 A (AC1) min. 10 mA
reinforced insulation on supply side and on control interface side
NC Status relay, floating status contact, option 1: break for failure,
option 2: break for run monitoring error message

EC centrifugal fans - RadiPac · Edition 2020-08 169

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 169 28.09.2020 11:59:33


Connection diagram: RP6)

Technical features:
• Control input 0-10 VDC / PWM • Locked-rotor protection / Soft start
• Output 10 VDC max. 10 mA • RS 485 MODBUS-RTU / PFC, passive
• Output 20 VDC max. 50 mA • Thermal overload protection for electronics/motor
• Output for slave 0-10 V • Motor current limitation / Alarm relay
• Operation and fault indicator • Undervoltage/phase failure detection
• Integrated PI controller • External enable input/External 24 V input (parameterization)
• Input for sensor 0-10 V or 4-20 mA

KL 1 KL 2
HZ (not

HZ (not

Ain1 U

Ain2 U

Ain2 I
Ain1 I

+20 V
+10 V

COM
GND

Aout

Din2

Din3
Din1
used)

used)

RSA

RSB

NO

NC
PE

PE

L2
L1

L3

Terminal Designation Assignment/function


KL1 PE Protective earth
L1 Power supply, phase, see nameplate for voltage range
L2 Power supply, phase, see nameplate for voltage range
L3 Power supply, phase, see nameplate for voltage range
HZ not used (optional: internal heating element)
KL2 RSA Bus connection RS485, RSA, MODBUS RTU; double terminal point (SELV)
RSB Bus connection RS485, RSB, MODBUS RTU; double terminal point (SELV)
GND Reference ground for control interface (SELV)
Ain1 U Analog input 1, set value: 0-10 V, Ri = 100 kΩ, adjustable curve,
only usable as alternative to input Ain1I; SELV
+10 V Fixed voltage output 10 VDC, + 10 V +/-3 %, max. 10 mA, short-circuit-proof power supply for external
devices (e.g. Poti); SELV
Ain1 I Analog input 1, set value: 4-20 mA, Ri = 100 Ω, adjustable curve,
only usable as alternative to input Ain1U; SELV
Din1 Digital input 1: enable electronics, enable: pin open or applied voltage 5-50 VDC
disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 VDC; SELV
Aout Analog output 0-10 VDC, max. 5 mA, output of current motor modulation level / motor speed
Technology

adjustable curve; SELV


Din2 Digital input 2: Switching parameter sets 1/2, according to EEPROM setting, the valid or used
parameter set can be selected via bus or via digital input DIN2.
Parameter set 1: pin open or applied voltage 5-50 VDC
Parameter set 2: bridge to GND or applied voltage <1 VDC; SELV
Din3 Digital input 3: Direction of action of integrated controller, according to EEPROM setting, the
direction of action of the integrated controller can be selected as normal/inverse via bus or digital input
Normal: Pin open or applied voltage 5-50 VDC;
Inverse: Bridge to GND or applied voltage < 1 VDC; SELV

170 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 170 28.09.2020 11:59:34


Connection diagram: RP6)

Terminal Designation Assignment/function


KL2 Ain2 U Analog input 2, measured value: 0-10 V, Ri = 100 kΩ, adjustable curve,
only usable as alternative to input Ain2 I; SELV
+20 V Fixed voltage output 20 VDC, + 20 V +25/-10 %, max. 50 mA, short-circuit-proof power supply for
external devices (e.g. sensors); SELV
or: +24 VDC input for parameter setting via MODBUS without line voltage
Ain2 I Analog input 2, measured value: 4-20 mA, Ri = 100 Ω, adjustable curve,
only usable as alternative to input Ain2 U; SELV
NO Status relay, floating status contact, make for failure,
COM Status relay, floating status contact, common connection,
contact rating 250 VAC / max. 2 A (AC1) / min. 10 mA
NC Status relay, floating status contact, break for failure,

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 171

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 171 28.09.2020 11:59:34


Connection diagram: RP7)

Technical features:
• Control input 0-10 VDC / PWM • Soft start / Motor current limitation
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output 20 VDC (+/-20 %) max. 50 mA • PFC, active / Power limiter
• Output for slave 0-10 V max. 5 mA • Thermal overload protection for electronics/motor
• Input for sensor 0-10 V or 4-20 mA • Undervoltage/phase failure detection
• Tach output • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)

KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain2 U

Ain2 I
+20V
GND

Aout
Din3
Din2

Ain1 U

Ain1 I
+10V

COM
GND
RS A

RS B

Din1

NO

NC

PE

L1

N
1 2 3 4 5 6 7 1 2 3 1 2

Terminal Pin Designation Assignment/function


KL1 1 L1 Power supply, phase, see nameplate for voltage range
2 N Power supply, neutral conductor, see nameplate for voltage range
PE PE Protective earth
KL2 1 NO Status relay, floating status contact, make for failure

2 COM Status relay, floating status contact, changeover contact, common connection,
contact rating, max. 250 VAC / 2 A (AC1) min. 10 mA
3 NC Status relay, floating status contact, break for failure

KL3 1 RSA Bus connection RS485, RSA, MODBUS-RTU; SELV


2 RSB Bus connection RS485, RSB, MODBUS-RTU; SELV
3/10 GND Reference ground for control interface, SELV
4 Ain1 U / PWM Analog input 1, set value: 0-10 V, Ri = 100 kΩ, adjustable curve,
only usable as alternative to input Ain1 I, SELV
Technology

5 +10V Voltage output 10 VDC,+10 V ± 3%,max.10 mA, power supply for external devices (e.g. pot), SELV
6 Ain1 I Analog input 1, set value: 4-20 mA, Ri = 100 Ω, adjustable curve,
only usable as alternative to input Ain1 U, SELV
7 Din1 Digital input 1: enable electronics,
enable: pin open or applied voltage 5-50 VDC, disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 VDC; SELV
8 Din2 Digital input 2: Switching parameter sets 1/2, according to EEPROM setting, the valid or used
parameter set can be selected via bus or via digital input DIN2.
Parameter set 1: pin open or applied voltage 5-50 VDC
Parameter set 2: bridge to GND or applied voltage < 1 VDC; SELV

172 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 172 28.09.2020 11:59:35


Connection diagram: RP7)

Terminal Pin Designation Assignment/function


KL3 9 Din3 Digital input 3: according to EEPROM setting, the integrated controller's direction of action can
be selected via bus or digital input Din3;
normal: pin open or applied voltage 5-50 VDC
inverse: bridge to GND or applied voltage < 1 VDC; SELV
11 Ain2 U Analog input 2, measured value: 0-10 V, Ri = 100 kΩ, adjustable curve,
only usable as alternative to input Ain2 I; SELV
12 +20V Voltage output 20 VDC,+20 V +25/-10%,max.50 mA, p. supply for ext.devices (e.g. sens.), SELV
13 Ain2 I Analog input 2, measured value: 4-20 mA, Ri = 100 Ω, adjustable curve,
only usable as alternative to input Ain2 U; SELV
14 Aout Analog output 0-10 VDC, max. 5 mA,
output of current motor modulation level / motor speed adjustable curve; SELV

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 173

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 173 28.09.2020 11:59:35


Connection diagram: RP8)

Technical features:
• Control input 0-10 VDC / PWM • PFC, passive / Temperature derating
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU
• Alarm relay / Soft start • EEPROM write cycles: 100.000 maximum
• Power limiter • Thermal overload protection for electronics/motor
• Motor current limitation • Undervoltage/phase failure detection
• Operation and fault indicator • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External 24 V input (parameterization)

NC L1
KL3
COM
L2 KL2
10V

0-10V L3

KL4 GND
RSA
RSB PE PE KL1

Terminal Designation Assignment/function


KL1 PE, PE Protective earth
KL2 L1, L2, L3 Power supply 50 / 60 Hz
KL3 NC Status relay, floating status contact, break for failure; contact rating 250 VAC / 2 A (AC1) / min. 10 mA,
reinforced insulation on supply side and basic insulation on control interface side
(or reinforced insulation on control interface side up to 250 VAC potential difference)
COM Status relay, floating status contact, break for failure; contact rating 250 VAC / 2 A (AC1) / min. 10 mA,
reinforced insulation on supply side and basic insulation on control interface side
(or reinforced insulation on control interface side up to 250 VAC potential difference)
KL4 +10 V Fixed voltage output 10 VDC, SELV, +10 V ±3%, max. 10 mA, short-circuit-proof,
power supply for external devices (e.g. pot);
fixed voltage input 24 VDC for setting parameters via MODBUS without line voltage supply
0-10 V Analog input (set value) SELV, 0-10 V, Ri = 100 kΩ, adjustable curve
GND Reference ground for control interface, SELV
RSA RS485 interface for MODBUS, RSA; SELV
RSB RS485 interface for MODBUS, RSB; SELV
Technology

174 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 174 28.09.2020 11:59:35


Technology

EC centrifugal fans - RadiPac · Edition 2020-08 175

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 175 28.09.2020 11:59:35


Connection diagram: RP9)

Technical features:
• Control input 0-10 VDC • Soft start / PFC, passive
• Output 10 VDC max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output for slave 0-10 V • Thermal overload protection for electronics/motor
• Motor current limitation • Undervoltage/phase failure detection
• Reverse polarity and locked-rotor protection • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)
• Power limiter

KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain1 U
+10V

Aout

COM
GND
RS A

RS B

Din1

NO

NC

PE

L1

L2

L3
1 2 3 4 5 6 7 1 2 3 1 2 3

Terminal Pin Designation Assignment/function


KL1 1 L1 Power supply, phase, see nameplate for voltage range
2 L2 Power supply, phase, see nameplate for voltage range
3 L3 Power supply, phase, see nameplate for voltage range
PE PE Protective earth
KL2 1 NO Status relay, floating status contact,
option 1: make for failure, option 2: make for error for run monitor
2 COM Status relay, floating status contact, common connection, contact rating 250 VAC / 2 A (AC1) /
min. 10 mA; basic insulation on supply side and reinforced insulation on control interface side
3 NC Status relay, floating status contact,
option 1: break for failure, option 2: break for error message for run monitor
KL3 1 RSA RS485 interface for MODBUS, RSA; SELV
2 RSB RS485 interface for MODBUS, RSB; SELV
3 GND Reference ground for control interface; SELV
4 Din1 Digital input 1: enable electronics,
Technology

enable: pin open or applied voltage 5-50 VDC, disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 VDC; SELV
5 ---
6 ---
7 ---
8 ---

176 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 176 28.09.2020 11:59:36


Terminal Pin Designation Assignment/function
KL3 9 +10V Voltage output, power supply for external devices (e.g. potentiometers), SELV
10 Ain1 U Analog input 1, set value: 0-10 V, Ri = 100 kΩ, adjustable curve; SELV
11 Aout Analog output 0-10 VDC, max. 5 mA, output of current motor modulation level / motor speed
adjustable curve; SELV
12 ---
13 ---
14 ---

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 177

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 177 28.09.2020 11:59:36


Effects of installation space
for EC centrifugal fans

Effects of installation space: Installation in a square box


W
may cause a reduction of the air performance.

Direction of air flow

d h = hydraulic diameter W = Width of the box


Formula: dh= 2 x W x H / (W + H) H = Height of the box D = Outside diameter of the fan

Correction values
for the air flow
Fan size 250 - 1000:
1,00
0,99
0,98
0,97
0,96
Correction factor for air flow
Technology

0,95
0,94

1,2 1,4 1,6 1,7 1,8

hydraulic diameter dh/D

The correction values shown here were determined from an The new RadiPac fans are known to be less vulnerable to tight
extensive series of measurements taken on our own internal installation situations. For square cross sections that are
chamber test rig. Here, square and rectangular outflow cross greater than 1.7 x the impeller diameter, no deduction has to
sections were considered. This is why the hydraulic diameter be applied to the catalog curves.
was used to determine the correction values.

178 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 178 28.09.2020 11:59:37


Airflow determination
for EC centrifugal fans

Airflow determination:

The differential pressure method compares the static pressure The pressure is tapped at 1 (4) point(s) on the circumference of
upstream of the inlet ring with the static pressure in the inlet ring. the inlet ring.

The airflow can be calculated from the differential pressure (bet- The customer connection consists of a built-in T-shaped
ween the static pressures) according to the following equation: hose fitting.

The hose fitting is suitable for pneumatic hoses with an


q V= k .£∆p qVin [m3/h] und ∆p in [Pa] inside diameter of 4 mm.

If the airflow is to be regulated to remain constant, the inlet pres-


sure must be kept constant:

∆p = q V2 : k2

k takes the specifi c properties of the inlet ring into account.

Direction of air flow


∆p
p

Technology

k-factors: (for RadiPac inlet rings)

Fan size 250 280 310 355 400 450 500


k-factor 76 77 116 148 188 240 281

Fan size 560 630 710 800 1000


k-factor 348 438 545 695 1200

EC centrifugal fans - RadiPac · Edition 2020-08 179

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 179 28.09.2020 11:59:37


Technical parameters & scope

High standards for all ebm-papst products


Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best possible product for your
application. Careful monitoring of the market ensures that technical innovations are reflected in the improvements of our products. Based
on the technical parameters listed below and the ambience you want our product to operate in, we here at ebm-papst can always work
out the best solution for your specific application.

General performance parameters The service life of the insulation system is essentially governed by
the voltage level, the temperature and the ambient conditions such
Any deviations from the technical data and parameters described
as humidity and condensation.
here are listed on the product-specific data sheet.

Degree of protection The service life of the bearing system is primarily governed by the
thermal load on the bearings. For the majority of our products we
The type of protection is specified in the product-specific data use maintenance-free ball bearings which can be fitted in any ins-
sheets. tallation position. Sleeve bearings can alternatively be employed,
as described in the product-specific data sheets.
Insulation class
As a rough guide (depending on the general conditions), the ball
The insulation class is specified in the product-specific data sheets. bearings have a life expectancy L10 of approx. 40.000 hours of
operation at an ambient temperature of 40 °C.
Installation position
We will gladly provide you with a life expectancy calculation based
The mounting position is specified in the product-specific data on your specific usage conditions.
sheets.
Motor protection/thermal protection
Condensate discharge holes
Information on motor protection and thermal protection is provi-
Information on the condensate discharge holes is provided in the ded in the product-specific data sheets.
product-specific data sheets. The following protection methods are provided depending on the
type of motor and area of application:
Mode of operation
– Thermal overload protector, in-circuit or external
The mode of operation is specified in the product-specific data
sheets. – PTC with electronic diagnostics
– Impedance protection
Protection class – Thermal overload protector with electronic diagnostics
The protection class is specified in the product-specific data sheets. – Current limitation via electronics
If use is made of an external thermal overload protector, a commer-
Tightening torques for fan assembly cially available tripping unit must be connected by the customer for
Technology

Please consult your ebm-papst contact for questions about which shut-off. Motor protection conforming to the applicable standard
tightening torque to use. must be fitted for products not provided with a built-in thermal
overload protector and not protected against improper use.
Service life
Mechanical strain/performance parameters
The service life of ebm-papst products depends on two main
factors: All ebm-papst products are subjected to comprehensive testing in
conformity with the normative specifications and also incorpora-
– The service life of the insulation system
ting the extensive experience of ebm-papst.
– The service life of the bearing system

180 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 180 28.09.2020 11:59:38


Technical parameters & scope

Vibration testing Standards


Vibration testing is performed as follows: Information on standards is provided in the product-specific data
– Vibration test in operation according to DIN IEC 68 Part 2-6 sheets.
– Vibration test at standstill according to DIN IEC 68 Part 2-6
EMC
Shock load
Information on EMC standards is provided in the product-specific
Shock load testing is performed as follows: data sheets. Compliance with EMC standards has to be assessed on
– Shock load according to DIN IEC 68 Part 2-27 the final product, as EMC properties may change under different
installation conditions.
Balancing grade
Touch current
Balancing grade testing is performed as follows:
– Residual imbalance according to DIN ISO 1940 Information on touch current is provided in the product-specific
– Standard balancing quality level G 6.3 data sheets. Measurement is performed according to IEC 60990.
Should your particular application require a higher level of
balancing, please contact us and specify the details in your order. Approvals

Please contact us if you require a specific type of approval (VDE,


Chemical and physical strain/performance parameters
UL, GOST, CCC, CSA, etc.) for your ebm-papst product. Most of
Please consult your ebm-papst contact for any questions regarding our products can be supplied with the applicable approval. Infor-
chemical and physical strain. mation on existing approvals is provided in the product-specific
data sheets.
Areas of use, industries & applications
Air performance measurements
Our products are used in a variety of industries and for numerous
applications: All air performance measurements are conducted on intake-side
Ventilation, air conditioning and refrigeration technology, clean chamber test rigs conforming to the requirements of ISO 5801
room technology, automotive and railway engineering, medi- and DIN 24163. The fans under test are attached to the measuring
cal and laboratory technology, electronics, computer and office chamber with free air intake and exhaust (installation category A)
Technology

systems, telecommunications, household appliances, heating and operated at nominal voltage, with alternating current also at
systems, machinery and installations, drive engineering. nominal frequency, without any additional attachments such as a
Our products are not intended for use in the aerospace industry! guard grill.
As required by the standards, the air performance curves shown are
Legal and normative specifications referenced to an air density of 1,15 kg/m³.
The products described in this catalog are developed and manufac-
tured in accordance with the standards applying to the particular
product and, if known, in accordance with the conditions of the
particular area of application.

EC centrifugal fans - RadiPac · Edition 2020-08 181

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 181 28.09.2020 11:59:38


Technical parameters & scope

Air and sound measurement conditions


Sound pressure and sound power level
Measurements on ebm-papst products are taken under the follo-
wing conditions: All acoustic values are determined in accordance with ISO 13347, DIN
– Axial and diagonal fans in airflow direction “V” in full 45635 and ISO 3744/3745 as per accuracy class 2 and given in A-rated
nozzle without guard grill form.
– Backward-curved centrifugal fans, free-running with For measurement of the sound pressure level Lp the microphone
inlet ring is located on the intake side of the fan being tested, generally at a
– Forward-curved single and dual-inlet centrifugal fans distance of 1 m on the fan axis.
with housing For measurement of the sound power level Lw 10 microphones are
– Backward-curved dual-inlet centrifugal fans with distributed over an enveloping surface on the intake side of the fan
housing being tested (see graphic). The measured sound power level can be
roughly calculated from the sound pressure level by adding 7 dB.
Sound measurements

All sound measurements are taken in anechoic rooms with rever- Measurement set-up according to ISO 13347-3 and DIN 45635-38:
berant floor. ebm-papst acoustic test chambers meet the require- 10 measuring pointse
ments of accuracy class 1 as per DIN EN ISO 3745. d≥D
For sound measurement, the fans being tested are positioned in a h = 1,5d ... 4,5d
reverberant wall and operated at nominal voltage, with alternating Measurement area S = 6d² + 7d (h + 1,5d)
current also at nominal frequency, without any additional attach-
ments such as a guard grill.

1,5d
D
Technology

3d

2d

182 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 182 28.09.2020 11:59:38


Technical parameters & scope

Cumulative level of several sound sources with the same level

15
[dB(A)]
[dB]
The addition of 2 sound sources with the same level produces a
level increase of approx. 3 dB.

Increase in sound pressure / sound power level


The noise characteristics of several identical fans can be predicted
on the basis of the sound values specified in the data sheet. This is

10
shown in the adjacent graph.

9
Example: There are 8 axial fans A3G800 on a condenser. According
to the data sheet, the sound pressure level of one fan is 75 dB(A).
The level increase determined from the graph is 9 dB. This means
that a total level of 84 dB(A) is to be expected for the installation.

5
0
1 2 3 4 5 6 7 8 9 10 15 20 25

Number of sources of sound with identical level

Cumulative level of two sound sources with different levels

3
[dB(A)]
The noise characteristics of two different fans can be predicted [dB]
on the basis of the sound values specified in the data sheet. This
is shown in the adjacent graph.
Increase in sound pressure / sound power level

Example: In a ventilation unit, there is one axial fan A3G800 with a


sound pressure level of 75 dB(A) at the point of operation and one
2

axial fan A3G710 with 71 dB(A). The difference in level is 4 dB. The
level increase of approx. 1.5 dB can now be read off the graph. This
1,5

means that a total level of 76.5 dB(A) is to be expected for the unit.
1
0

0 4 8 12 16 20 24
Distance laws Difference in level with two sources of sound [dB]
[dB(A)]
The sound power level is not governed by the distance from the
noise source. By contrast, the sound pressure level decreases with
increasing distance from the sound source. The adjacent graph
0
[dB(A)]

shows the decrease in level under far fi eld conditions. Far field
[dB]

conditions apply if there is a considerable distance between the


microphone and the fan in relation to the fan diameter and the wa-
velength under consideration. On account of the complexity of the
-10

topic, literature should be consulted for more detailed information


Technology

on far fields. The level in the far fi eld decreases by 6 dB each time
the distance is doubled. Different relationships apply in the near
Decrease in sound pressure level
-20

field of the fan and the level may decrease to a far lesser extent.
The following example only applies to far field conditions and may
-26

vary considerably as a result of installation effects:


For an axial fan A3G300, a sound pressure level of 65 dB(A) was
-30

measured at a distance of 1 m. From the adjacent graph, this would


yield a reduction of 26 dB at a distance of 20 m, i.e. a sound
pressure level of 39 dB(A).
-40

1 2 5 10 20 50 100

Distance [m]

EC centrifugal fans - RadiPac · Edition 2020-08 183

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 183 28.09.2020 11:59:39


Technical parameters & scope
Aerodynamics fundamentals:

Further information can be found in our brochure "Technology - Basic principles"

Centrifugal fan operating range:

[%]
[dB(A)]
[Pa]
Middle section of the air performance curve:
– Maximum efficiency
– Minimum noise

To the left and right of the middle section of the air performance
curve:
– Reduced efficiency
– Increasing noise

sound pressure level


The fan‘s optimal range of use is highlighted in green in the static pressure increase
adjoining performance curve.

efficiency
optimum operating range
0

air flow [m³/h]


Technology

184 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 184 28.09.2020 11:59:39


Technical parameters & scope- Strömungstechnische Grundlagen

Influence of Speed n on the sound power level Lw:

[dB]
The sound power level for changes in speed can be approximately
determined based on the adjoining diagram and the following

20
formula:

Lw₂ - Lw₁ = 50 dB · log (n₂ : n₁)

10
Modification in sound pressure level
Lw₁ = Sound power level after speed change
Lw₂ = Sound power level before speed change

0
n₁ = Changed speed
n₂ = Initial speed
-10
-20

0,5 1 1,5 2 2,5 3

Factor of speed change

Technology

EC centrifugal fans - RadiPac · Edition 2020-08 185

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 185 28.09.2020 11:59:39


Always find the right contact person! www.eb

186 EC centrifugal fans - RadiPac · Edition 2020-08

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 186 28.09.2020 11:59:41


Contacts
Worldwide

the engineer’s choice

Germany

ebm-papst Mulfingen GmbH & Co. KG


Bachmühle 2
74673 Mulfingen
GERMANY
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com

ebm-papst St. Georgen GmbH & Co. KG


Hermann-Papst-Straße 1
78112 St. Georgen
GERMANY
Phone +49 7724 81-0
Fax +49 7724 81-1309
info2@de.ebmpapst.com

ebm-papst Landshut GmbH


Hofmark-Aich-Straße 25
84030 Landshut
GERMANY
Phone +49 871 707-0
Fax +49 871 707-465
info3@de.ebmpapst.com
Contacts

ww.ebmpapst.com/contact

EC centrifugal fans - RadiPac · Edition 2020-08 187

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 187 28.09.2020 11:59:42


www.ebmpapst.com

the engineer’s choice

ebm-papst
Mulfingen GmbH & Co. KG

Bachmühle 2
74673 Mulfingen
Germany
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com

RadiPac-Katalog_2020_EN_28_09_2020_Final___.indd 188 28.09.2020 11:59:43

You might also like