Professional Documents
Culture Documents
RadiPac-Katalog 2020 EN 28 09 2020 Final Klein 1
RadiPac-Katalog 2020 EN 28 09 2020 Final Klein 1
2600
10
2000
8
560 630
1800
1600
6
1400
250
1200 Air performance range for RadiPac „Standard“
1000 280
4
800
600 560
2
400
630
450
200 355 400 1000
310 500 710 800
pfs
Information
Information
A convincing concept with a wide range 6
of applications / FanScout
Product overview 12
Accesories
Accesories
Intake finger guard 155
Inlet rings 156
Vibration absorbers 160
Technology
Contacts
ebm-papst worldwide
ebm-papst is a leader in ventilation and drive engineering technology and a much sought-after engineering partner in many
Information
Information
industries. With around 20.000 different products, we have the perfect solution for practically every requirement. We have
placed the highest emphasis on economy and ecology for many years.
We believe the consistent further development of our highly-efficient GreenTech EC technology provides our customers
with the best opportunities for the future in industrial digitization. With GreenIntelligence, ebm-papst already offers in-
telligent networked complete solutions that are unique anywhere in the world today and that secure our customers a
decisive advantage.
Accesories
Technology
Contacts
Contacts
Why do our customers look so happy? Because when it co- With our comprehensive range of services, we accom-
mes to the Internet of Things and the digital transformation, pany you and your projects through every step in the pro-
Information
Information
we provide them with a clear competitive edge with Green- cess, from your application’s planning to its deployment.
Intelligence for intelligent control and interconnection of Make use of our experts’ product expertise to offer your
fans, drives and systems to make applications more power- customers new and advanced features. Or use our digital
ful, processes more efficient, businesses more successful and tools for optimal product selection. That will make your
their customers more satisfied. processes more efficient and get your products to market
faster.
For industrial ventilation technology, solutions are in
demand that ensure top performance and operational relia- Now you know why ebm-papst makes engineers happy.
bility in every situation. GreenIntelligence gives you robust
fan solutions with intelligent networking capabilities that
provide reliable performance data and extensive control and
monitoring functions. They ensure high levels of efficiency
and system availability while guaranteeing maximum
Accesories
points
– Automatic condition monitoring
– Fan as a sensor
Technology
Technology
Contacts
Contacts
Information
Accesories
Technology
Technology
Contacts
Contacts
Information
Information
Motor impellers are available in sizes 250 to 560 in all
impeller/motor combinations.
In addition to an inlet ring, an appropriately dimensi-
oned motor mount must be provided on site to operate
a motor-impeller.
Accesories
Technology
Contacts
Information
Accesories
to the MODBUS RTU interface. has to convey, the further apart the fans should be. The di-
mensions of the FanGrid module with cube design are very
generous and large enough to prevent installation losses.
Technology
Technology
Contacts
Contacts
Information
RadiPac for restaurants and process exhaust air: RadiPac with high static pressure:
clean air according to standards. Ventilate buildings efficiently.
Accesories
Optimum cooling included. Of course the new fans offer you the series’ many other
Thanks to the underpressure upstream of the fan com- advantages, including its high reliability, energy-efficiency
pared to the surroundings, cool ambient air is drawn in and compactness. And the rugged cube design is available
Technology
Technology
through a hose to cool the encapsulated motor. as an option again. Just install, connect with plug & play,
This means that the fan and the control system achieve and „turn up the pressure“.
their full output and high flow medium temperatures can
be allowed at a corresponding cooling air temperature.
Contacts
Contacts
Information
in sizes 250 to 800 with additional corrosion protection buildings to temper the supply air using the warm exhaust
measures. This applies to both the centrifugal module with air. For this purpose, fans convey the air through the heat
support bracket and the cube design. In these versions, all exchanger and then through the inlet and exhaust air
metal surfaces have an additional coating. The color used ducts. Our RadiFit is compact, can be adjusted flexibly and
is black. is highly efficient, so it satisfies strict energy conservation
regulations.
RadiPac with reversed nozzle plate.
Centrifugal fans with a support bracket are available in In central air-conditioning units, the air must be trans-
sizes 310 to 560 in an additional mechanical design with a ported through various components such as filters, heat
reversed nozzle plate. exchangers, humidifiers and branched duct systems. The
fans have to compensate for the high pressure losses. The
In the standard version, the system should also save as much space as possible and per-
circumferential chamfer on mit simple, demand-based ventilation for a large number
the mounting plate faces up- of rooms. No problem for the RadiFit.
stream.
In the reversed version, the For cooling generators, a fan forces the ambient air
chamfer points downstream. through narrow ducts on the generator to cool it. The
RadiFit’s integrated speed control means that cooling can
ATEX fans. always be adapted to the load or heat generation. The fan
ebm-papst offers specially protected RadiPacs for use in requires very little space, as no separate control unit is
potentially explosive atmospheres available in sizes 400 to required. And it's maintenance-free too!
630. It is unique for a highly efficient EC motor with integ-
Accesories
Accesories
Technology
Contacts
Contacts
Our axial fans can be configured individually for each appli- al measurements and the data calculated using the soft-
cation, and it is important to correctly consider all the rele- ware and assigned the accuracy of the calculation to the
Information
Information
vant aspects when selecting your axial fan. When making highest class.
your selection, you can rely on our experts' many years of
experience, and on our professional fan selection software Exact presentation of the life cycle costs:
as well: The costs of operation, acquisition, installation and service
can be calculated for a defined period of time.
With its outstanding user-friendliness and real measured A practical advantage:
values, the ebm-papst FanScout has more than proven its The software can be easily integrated into your device
worth already. It not only measures the performance of the configuration program using the DLL interface.
individual fan components but also that of the fan as a
complete system. The program allows you to quickly select The best part:
the best fan for your application, to describe and modify ebm-papst pre-selects the products that are suitable for
the operating behavior and to document the technical spe- you. This saves you the trouble of searching through the
cifications. Factors such as air performance, operating time broad product portfolio and helps you configure your appli-
Accesories
Accesories
Technology
Technology
Contacts
Information
Accesories
Technology
Contacts
1) Centrifugal fan & FanGrid with resonance sensor 2) With active PFC
Information
Information
Nominal Max. Centrifugal Centrifugal
voltage input Centrifugal fan module with module with
range power support bracket cube design on
Size VAC W Page
Type Part number Type Part number Type Part number
3~380-480 4250
???? VBS0630PTTRS R3G630PC0803 VBH0630PTTRS K3G630PC0803 --- ---
3~380-480 3750
???? VBS0630PTTRS
VBS0710PTTRS R3G630PC0803
R3G710PC0503 VBH0710PTTRS K3G710PC0503 --- ---
3~380-480 2800
???? VBS0630PTTRS
VBS0800PTTRS R3G630PC0803
R3G800PC0203 VBH0800PTTRS K3G800PC0203 --- ---
Accesories
Technology
Contacts
EC centrifugal fans - RadiPac (with reversed nozzle plate / improved corrosion protection)
Information
Information
Accesories
Technology
Contacts
Information
Information
Nominal Max. Centrifugal module with Centrifugal module with
voltage input support bracket and support bracket and impro-
range power reversed nozzle plate ved corrosion protection
Size VAC W
Type Part number Type Part number
Accesories
Technology
Technology
Contacts
EC centrifugal fans - RadiPac (with reversed nozzle plate / improved corrosion protection)
Information
Information
Accesories
Technology
Technology
Contacts
EC centrifugal fans - RadiPac (for the food service sector and process exhaust air)
Information
Information
Nominal Max.
voltage input Centrifugal module with cube design
range power on
Size VAC W Page
Type Part number
Accesories
Accesories
Technology
Technology
Contacts
Information
Nominal Max.
voltage input Centrifugal module with cube design
range power on
Size VAC W Page
Type Part number
Accesories
Technology
Technology
Contacts
Information
Information
Nominal Max. Centrifugal fan - RadiFit
voltage input with housing
range power on
Size VAC W Page
Type Part number
Accesories
Accesories
Technology
Technology
Contacts
Type R3G... RadiPac motor impellers are available in sizes 250 to 560 for all impeller/motor combinations. For sizes 630 to 800,
these versions are only available in combination with the lightweight size 150 motor. Operation of a type R3G... motor impeller
requires an inlet ring and a motor mounting of suitable dimensions to be provided by the customer.
Tender specification 22
Information
250 24
280 30
310 36
355 44
400 52
500 68
560 78
630 86
710 92
800 98
1000 104
Accesories
Technology
Contacts
Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics.
Impeller made of aluminum, with 5 backwards-curved, con- connected to die-cast corner plates, nozzle plate and inlet
tinuously welded, hollow-profile blades; impeller sizes 250 ring made of sendzimir galvanized sheet steel, motor
and 280 made of plastic; flow-optimized inlet ring made of mounting plate made of coated sheet steel. This version is
galvanized sheet steel with pressure test nipple. not suitable for wall mounting.
Motor impeller statically and dynamically balanced on two Any work required for isolation from structure-borne noise
planes to balancing grade G 6.3 (motor size 200 to balan- to be performed by the customer. Fan satisfies the applica-
cing grade G 4.0) in accordance with DIN ISO 21940. ble EMC guidelines and requirements with regard to circuit
EC centrifugal fans - RadiPac · Edition 2020-08
Technical data:
Fan type = __ __ __ __ __ __ - __ __ __ __ - __ __
Information
Air flow qV = _________________________________ m3/h, cfm
Line frequency f = 50 / 60 Hz
Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)
Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)
Accesories
Weight of fan m = _________________________________ kg
Technology
Contacts
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: PP plastic
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 6
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 26 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa
C sheets.
3 =max.
B 4
5
1200
3
1000 4
4
A
4
800
3
3
3
600 2
2
400 2
2
1
200
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0250PSPGS R3G250PR04H1
fan ❶ 230 3380 490 2,16 84
❷ 230 3125 520 2,29 77
A ❸ 230 3080 500 2,30 74 -25..+40 IP 55 RP3)
Information
Centrifugal
VBS0250PSPGS R3G250PR17I1
fan ❶ 230 3645 630 2,74 87
❷ 230 3490 730 3,19 82
B ❸ 230 3450 750 3,30 78 -25..+40 IP 55 RP3)
Centrifugal
VBS0250PTPGS R3G250PR02J1
fan ❶ 400 4000 820 1,27 91
❷ 400 4000 1110 1,72 86
C ❸ 400 4000 1180 1,80 83 -25..+40 IP 55 RP4)
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
4x90°
2 M6 (4x)
45°
47.7
Ø172.5±0.3
Ø150±0.35
Ø270
Ø178
+20
1
1000
116.8
3 4
85±10
152.5±1.8
8
10 Ø164±0.35
1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules
1 10
00 +
20
85
8 ±1
0
Ø11 (4x)
10 3
2
4
1.5 298
5 2 350
187±2 400
234.7±3
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid
4x90°
45°
2 M6 (4x)
64.1
Ø172.5±0.3
Ø169±0.35
Ø270
Ø200
Information
1
+20
1000
116.8
152.5±1.8 3 4
85±10
8
10 Ø186±0.5
1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)
1 10
00 +
20
85
Accesories
8 ±1
0
Ø11 (4x)
10 3
2
4
1.5 298
5 2 350
Technology
187±2 400
251.1±3
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid
4x90°
2 M6 (4x) 45°
64.1
Ø172.5±0.3
Ø169±0.35
Ø270
Ø200
+20
1
1000
116.8
152.5±1.8 3
4
85±10
8
10 Ø186±0.5
1 Accessory part: Inlet ring 96355-2-4013 with pressure tap (k-factor: 76) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 6x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules
1 10
00 +
20
85
8 ±1
0
Ø11 (4x)
10 3
2
4
1.5 298
5 2 350
187±2 400
251.1±3
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 6x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 76)
5 Mounting holes: for FlowGrid
28.09.2020 11:55:49
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: PP plastic
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 6
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 32 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa
sheets.
C 3 =max.
5
1200
4
B 4
4
800 A 4
3
2
2
400 2
2
1
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0280PSPGS R3G280PR03H1
fan ❶ 230 2990 500 2,18 85
❷ 230 2785 500 2,30 79
A ❸ 230 2670 500 2,30 72 -25..+45 IP 55 RP3)
Information
Centrifugal
VBS0280PSPGS R3G280PR04I1
fan ❶ 230 3260 640 2,81 87
❷ 230 3115 730 3,18 82
B ❸ 230 3000 750 3,30 77 -25..+45 IP 55 RP3)
Centrifugal
VBS0280PTPKS R3G280PS10J1
fan ❶ 400 3400 740 1,17 88
❷ 400 3400 960 1,49 83
C ❸ 400 3400 1050 1,60 80 -25..+45 IP 55 RP4)
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
4x90°
2 45°
M6 (4x)
47.7
Ø187.5±0.3
Ø150±0.35
Ø294
Ø178
+20
1
1000
127
85±10
160±1.8 3 4
8
Ø164±0.35
8
1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 5x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules
1 10
00 +
20
85
8 ±1
0
Ø11 (4x)
10 3
2
4
1.25 298
5 2 350
194.5±2 400
242.2±3
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid
4x90°
2 45°
M6 (4x)
64.1
Ø187.5±0.3
Ø169±0.35
Ø200
Ø294
Information
+20
1
1000
127
85±10
3 4
8
160±1.8
Ø186±0.5
8
1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)
1 10
00 +
20
85
Accesories
8 ±1
0
Ø11 (4x)
10 3
2
4
1.25
298
5 2 350
Technology
194.5±2 400
258.6±3
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 5x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid
4x90°
2 45°
M6 (4x)
64.1
Ø187.5±0.3
Ø169±0.35
Ø200
Ø294
+20
1
1000
127
85±10
3 4
8
175±1.8
Ø186±0.5
8
1 Accessory part: Inlet ring 28004-2-4013 with pressure tap (k-factor: 77) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable: PVC AWG18, 6x crimped ferrules
4 Cable: PVC AWG22, 5x crimped ferrules
1 10
00 +
20
85
8 ±1
0
Ø11 (4x)
10 3
2
4
1.25 298
5 2 350
209.5±2 400
273.6±3
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable: PVC AWG18, 6x crimped ferrules
3 Cable: PVC AWG22, 5x crimped ferrules
4 Inlet ring: with pressure tap (k-factor: 77)
5 Mounting holes: for FlowGrid
28.09.2020 11:56:17
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 38 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 165 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa
sheets.
2000 3 =max.
44
1800
1600 E 3
D 3
6
1400 F
4
4
1200 4
4
1000 C 333
4
3 3 2 2
800 B
600 2
2 2
2
400
200 A
1 1 13500 1 1 cfm
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0310PSRHS R3G310PG5721
fan ❶ 230 3200 875 3,80 93
❷ 230 3200 1380 6,01 84
A ❸ 230 3200 1500 6,50 82 -25..+45 IP 54 RP7)
Information
Centrifugal
VBS0310PSRHS R3G310PG9321
fan ❶ 230 3200 1035 4,51 95
❷ 230 3200 1375 6,00 88
B ❸ 230 3200 1500 6,60 81 -25..+55 IP 54 RP7)
Centrifugal
VBS0310PTPMS R3G310PT08J1
fan ❶ 400 3010 670 1,06 95
❷ 400 3010 1050 1,61 84
C ❸ 400 3010 1230 1,90 78 -25..+40 IP 55 RP4)
Centrifugal
VBS0310PTPMS R3G310PT10W1
fan ❶ 400 3140 900 1,40 93
❷ 400 3140 1240 1,90 86
D ❸ 400 3140 1370 2,10 81 -40..+40 IP 55 RP4)
Centrifugal
VBS0310PTRLS R3G310PV6903
fan ❶ 400 4000 2200 3,44 105
❷ 400 4000 2855 4,41 93
E ❸ 400 4000 3050 4,70 89 -40..+40 IP 55 RP5)
Centrifugal
VBS0310PTRLS R3G310PV6902
fan ❶ 400 4000 1760 2,79 103
❷ 400 4000 2640 4,08 91
F ❸ 400 4000 3000 4,70 86 -40..+40 IP 55 RP5)
Accesories
Subject to change Values set in blue are nominal data at operating point with maximum load.
Technology
Contacts
2 M10 (6x)
72
6x6
0°
Ø223.5+1
Ø360
Ø232
1
98.2 M20x1.5 (3x)
179 3
231±2 Ø252 ±0.5
Ø275
6
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm
4x90
5 Ø4.5 (4x) 45
1
3
Ø11 (4x)
4
Ø290 15 M20x1.5 (3x) 2
275.5 1 375
347.5 3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
2 M10 6x)
72
6x6
0
Ø223.5+1
Ø232
Ø360
4
Information
98.2 1 3 M20x1.5 (3x)
179 Ø252 0.5
204 2 Ø275
6
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
4x90
5 Ø4.5 (4x) 45
1
3
Accesories
Ø9.2 (8x)
4
Ø290 15 M20x1.5 (3x) 2
Technology
248.5 1 375
320.5 3 450
500
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
4x9
45° 0°
2 M6 (4x)
108.5
Ø169±0.35
Ø223.5+1
Ø360
Ø200
1 4
98.2 3
179 Ø186±0.5
255.5±1.8
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
EC centrifugal fans - RadiPac · Edition 2020-08
3 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
5 Tightening torque: 1.5 ± 0.2 Nm
4x90
°
45°
Ø4.5 (x4) 5
6
1
Ø11 (4x)
2 3
4
Ø290 15 372
300±2.5 450
408.5±3 500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm
4x90
2 M6 (4x) 45
108.5
Ø223.5+1
5
Ø169
Ø360
Information
1
3
98.2
4
179
Ø186 0.5
255.5 2
6 Ø200
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
4x90
5 Ø4.5 (4x) 45
1 6
Accesories
Ø11 (4x)
3
2
4
Ø290 15 372
Technology
244 2 450
352.5 3 500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
Contacts
2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm
2 M10 (6x)
70
6x6
0
Ø223.5+1
Ø360
Ø232
98.2 3
179 M20x1.5 (3x) Ø252 0.5
227 2 Ø275
6
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm
4x90
45
5 Ø4.5 (4x)
4
Ø11 (4x)
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 116)
5 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø223.5+1
Ø232
Ø360
4
Information
1
98.2 3
179 Ø252 0.5
271 2 Ø275
6
1 Accessory part: Inlet ring 31475-2-4013 with pressure tap (k-factor: 116) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 46 Drawings
■ Mounting: Maintenance-free ball bearings
on Page 152 Accesories
on Page 164 Connection diagrams and technical features Further Information
on Page 180 Technical parameters & scope ■ Information about touch current, electrical
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
can be found in the product-specific data
in. wg
Pa
sheets.
4 4 3 =max.
1600
E
6
1400 D 3
3
1200 B
4 4
1000 4
4
33
800
A 3 2
2
600
2
2
2 2
400
200 C
1 14000 1cfm
1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 1~200-277 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0355PSRLS R3G355PH3821
fan ❶ 230 2590 885 3,74 88
❷ 230 2590 1360 5,94 81
A ❸ 230 2590 1500 6,60 80 -25..+40 IP 54 RP7)
Information
Centrifugal
VBS0355PSHRS R3G355PG5421
fan ❶ 230 2600 920 4,03 98
❷ 230 2600 1340 5,83 86
B ❸ 230 2600 1500 6,60 79 -25..+40 IP 55 RP7)
Centrifugal
VBS0355PTPMS R3G355PT12W1
fan ❶ 400 2500 735 1,15 95
❷ 400 2500 1060 1,78 81
C ❸ 400 2500 1300 2,00 77 -40..+40 IP 55 RP4)
Centrifugal
VBS0355PTRLS R3G355PV7001
fan ❶ 400 3230 1760 2,77 100
❷ 400 3230 2500 3,85 90
D ❸ 400 3230 2900 4,40 85 -40..+40 IP 55 RP5)
Centrifugal
VBS0355PTRLS R3G355PV7002
fan ❶ 400 3230 1630 2,58 102
❷ 400 3230 2540 3,91 89
E ❸ 400 3230 2900 4,40 83 -40..+40 IP 55 RP5)
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
2 M10 (6x)
72
6x6
0°
Ø252.5+1
Ø232
Ø405
4
1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 3.5 ± 0.5 Nm
5 (4x)
3
Ø11 (4x)
4
15 M20x1.5 (3x) 2
325.5 2 417
397.5 3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid
2 M10 (6x)
72
6x6
0
Ø252.5+1
Ø232
Ø405
4
Information
1
M20x1.5 (3x)
110.5 3
199.7 Ø252 0.5
225 2 Ø275
6
1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
5 (4x)
1
3
Accesories
Ø11 (4x)
4
15 M20x1.5 (3x) 2
279.5 417
Technology
2
351.5 3 450
500
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 3.5 ± 0.5 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid
4x90
2 M6 (4x) 45
108.5
Ø252.5+1
5
Ø169
Ø405
1
110.5 3
199.7 4
251.8 2 6 Ø186 0.5
Ø200
1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 16 mm rotor on bottom, rotor on top on request
EC centrifugal fans - RadiPac · Edition 2020-08
3 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
5 Tightening torque: 1.5 ± 0.2 Nm
5 (4x)
1 6
Ø11 (4x)
3
2
4
15 414
305.5 2 450
414 3 500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
3 Cable gland M16 x 1.5 (2x): Cable diameter min. 6 mm, max. 10 mm, Tightening torque 1.8 ± 0.3 Nm
(use must be made of seal provided)
Cable diameter min. 4 mm, max. 7 mm, Tightening torque 1.8 ± 0.3 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid
6 Tightening torque: 1.5 ± 0.2 Nm
28.09.2020 11:56:45
EC centrifugal fans - RadiPac · Edition 2020-08
2 M10 (6x)
70
6x6
0
Ø252.5+1
Ø232
Ø405
4
110.5 1 3
199.7 Ø252 0.5
248 2 Ø275
6
1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm
5 (4x)
1
3
Ø405
Ø11 (4x)
4
15 2
302.5 2 375
372.5 3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 148)
5 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø252.5+1
Ø232
Ø405
4
Information
1
110.5 3
199.7 Ø252 0.5
292 2 Ø275
6
1 Accessory part: Inlet ring 35675-2-4013 with pressure tap (k-factor: 148) Pin assignment: (see connection diagram)
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
Accesories
Technology
Contacts
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 54 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
1400
1200
A 3
3
1000 B
4
800
600 2 2
2
400
200
1 1 cfm
1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0400PTRNS R3G400PW0301
fan ❶ 400 2700 2175 3,38 98
❷ 400 2700 2980 4,57 90
A ❸ 400 2700 3400 5,20 85 -40..+40 IP 55 RP5)
Information
Centrifugal
VBS0400PTTLS R3G400PA2702
fan ❶ 400 2800 2175 3,38 99
❷ 400 2800 3190 4,88 91
B ❸ 400 2800 3650 5,50 86 -40..+40 IP 55 RP5)
Reso-
VBS0400PTTLS R3G400PA2765 Centrifugal nance-
fan sensor
Reso-
VBH0400PTTLS K3G400PA27W5 Cube nance-
(FanGrid) sensor
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
2 M10 (6x)
70
6x6
0
Ø288.2+1.5
Ø232
Ø455
4
1
128.75 3
225.5 Ø252 0.5
273 3 Ø275
5
1 Accessory part: Inlet ring 40078-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm
4x90
15 5 Ø9 (4x)
3
Ø455
Ø11 (4x)
4
Ø440 15 2
331.2 2.5 417
401.2 3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø285.2+1.5
Ø232
Ø455
4
Information
1
128.8 3
225.5 Ø252 0.5
310 2 Ø275
5
1 Accessory part: Inlet ring 40075-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
2 M10 (6x)
70
6x6
0°
Ø285.2+1.5
Ø232
Ø455
4
M20x1.5 (3x)
128.75 1 3
225.5 Ø252 ±0.5
273 ±2 Ø275
5
1 Accessory part: Inlet ring 40075-2-4013 with pressure tap (k-factor: 188)) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
4 Tightening torque: 1.5 ± 0.2 Nm
4x90°
Ø9 (4x) 5 35°
1
3
Ø455
Ø11 (8x)
4
Ø440 15 M20x1.5 (3x) 2
331.2±2.5 417
401.2±3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid
C VBH0400PTTLS K3G400PA27W4 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø9 (4x) 35° Ø9 (16x)
200
1
200
3
Information
200
2
Ø440 20
4
699 40
445
522
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
C VBH0400PTTLS K3G400PA27W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø9 (4x) 35° Ø9 (16x)
200
1
200
Accesories
200
2
Ø440 20
4
699 40
Technology
445
522
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 188))
5 Mounting holes: for FlowGrid
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 60 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
1600 4
C E 4
6
1400 3
4
B
1200 3
44 3
1000 A
4
800 3 2
600 2 22
2
400 22 D
200
111 11 1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0450PTRNS R3G450PW1202
fan ❶ 400 2040 1515 2,42 93
❷ 400 2040 2160 3,36 86
A ❸ 400 2040 2650 4,10 79 -40..+40 IP 55 RP5)
Information
Centrifugal
VBS0450PTRNS R3G450PW1201
fan ❶ 400 2040 1625 2,58 95
❷ 400 2040 2210 3,43 87
B ❸ 400 2040 2650 4,10 80 -40..+40 IP 55 RP5)
Centrifugal PFC
VBS0450PTTLS R3G450PA21C1
fan active ❶ 400 2200 1960 2,84 96
❷ 400 2200 2915 4,20 88
C ❸ 400 2200 3190 4,60 87 -25..+40 IP 55 RP1)
Reso-
VBS0450PTTLS R3G450PA3165 Centrifugal nance-
fan sensor
❶ 400 2480 2775 4,26 99
Support ❷ 400 2480 3925 5,98 92
E VBH0450PTTLS K3G450PA3103
bracket ❸ 400 2480 4450 6,80 85
-40..+45 IP 55 RP5)
❹ 400 2480 4415 6,71 89
Reso-
VBH0450PTTLS K3G450PA31W5 Cube nance-
Accesories
(FanGrid) sensor
Centrifugal
VBS0450PTTPS R3G450PB2401
fan ❶ 400 2600 3065 4,78 102
❷ 400 2600 4640 7,13 92
F ❸ 400 2600 5250 8,00 87 -25..+50 IP 55 RP1)
Support ❹ 400 2600 5140 7,89 91
Technology
VBH0450PTTPS K3G450PB2401
bracket
Subject to change Values set in blue are nominal data at operating point with maximum load.
Contacts
2 M10 (6x)
70
6x6
0
Ø319.7+1.5
Ø232
Ø530
4
140.2 3
253.6 Ø252 0.5
368 3 Ø275
5
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
2 M10 (6x)
70
6x6
0
Ø319.7+1.5
Ø232
Ø530
4
Information
140.2 1 3
253.6 Ø252 0.5
304 3 Ø275
5
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
4x90
5 Ø10 (4x) 15
1
3
Accesories
Ø11 (8x)
4
Ø440 15 2
369.5 2 551
439.5 3 580
Technology
630
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid
2 M10 (6x)
113
6x6
0°
Ø319.7+1.5
Ø280
Ø530
5
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm
C VBH0450PTTLS K3G450PA21C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm
4x90°
15°
6 Ø10 (4x)
1
4
Ø530
5
Ø11 (8x)
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 240)
6 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø319.7+1.5
Ø232
Ø530
4
Information
1
140.2 3
253.6 Ø252 0.5
341 2 5 Ø275
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
6x60°
304±2 2
M10 (6x)
60
70
°
Ø319,7+1,5
Ø232
Ø530
Ø275
140,2 3
253,6 Ø252±0,5
5
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
Ø10 (4
x) 5
4x90°
15°
1
3
Ø11 (8x)
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid
E VBH0450PTTLS K3G450PA31W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø10 (4x) 15° Ø9 (16x)
200
1
200
3
200
Information
2
Ø440 20
4
799 40
483
620
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
E VBH0450PTTLS K3G450PA31W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø10 (4x) 15° Ø9 (16x)
200
1
200
Accesories
200
2
Ø440 20
4
799 40
483
Technology
620
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 240)
5 Mounting holes: for FlowGrid
2 M10 (6x)
113
6x6
0°
Ø319.7+1.5
Ø280
Ø530
5
1
M20x1.5 (2x)
3
140 M25x1.5
4
254
376 ±2 Ø304 ±0.5
5 Ø324
1 Accessory part: Inlet ring 45075-2-4013 with pressure tap (k-factor: 240) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 25 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm
4x90°
6 Ø9 (4x) 15°
1
4
Ø530
Ø11 (8x)
M25x1.5
5
Ø440 15 M20x1.5 (2x) 2
3
442.5±2
556±3 580
622
630
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 240)
6 Mounting holes: for FlowGrid
28.09.2020 11:57:23
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 70 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
1400
4 4
4
1200 C 3
4
1000 B 3 33
4
4
3
800 A
3 2
600
2 22
2
400 2
200
1 8000 1 11 1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0500PTRNS R3G500PW0901
fan ❶ 400 1670 1340 2,17 100
❷ 400 1670 2020 3,16 89
A ❸ 400 1670 2350 3,60 80 -40..+40 IP 55 RP5)
Information
Centrifugal PFC
VBS0500PTTLS R3G500PA26C1
fan active ❶ 400 1810 1800 2,60 102
❷ 400 1810 2700 3,90 91
B ❸ 400 1810 3100 4,50 82 -25..+40 IP 55 RP1)
Centrifugal
VBS0500PTTLS R3G500PA2803
fan ❶ 400 1890 2020 3,16 101
❷ 400 1890 2950 4,53 92
C ❸ 400 1890 3350 5,20 85 -40..+40 IP 55 RP5)
Reso-
VBS0500PTTPS R3G500PB2465 Centrifugal nance-
fan sensor
❶ 400 2000 2410 3,73 101
E VBH0500PTTPS K3G500PB2403 Support ❷ 400 2000 3375 5,15 93
-40..+45 IP 55 RP5)
bracket ❸ 400 2000 3900 6,00 86
❹ 400 2000 3750 5,71 88
Reso-
VBH0500PTTPS K3G500PB24W5 Cube nance-
Accesories
(FanGrid) sensor
Centrifugal
VBS0500PTTPS R3G500PB3301
fan ❶ 400 2250 3240 5,05 105
❷ 400 2250 4860 7,47 95
F ❸ 400 2250 5700 9,00 88 -25..+40 IP 55 RP1)
Support ❹ 400 2250 5700 8,74 87
Technology
VBH0500PTTPS K3G500PB3301
bracket
Subject to change Values set in blue are nominal data at operating point with maximum load.
Contacts
2 M10 (6x)
70
6x6
0°
Ø355 +2
Ø232
Ø585
4
1 M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 Ø275
5
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90
5 Ø9 (4x) 15
1
3
Ø585
Ø11 (8x)
4
Ø440 15 M20x1.5 (3x) 2
401 2 551
471 3 580
630
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid
2 M10 (6x)
113
6x6
0°
Ø355±2
Ø585
Ø280
Information
1
156 M20x1.5 (2x) 3
282 4 M25x1.5
341±2 Ø304±0.5
5 Ø324
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
B VBH0500PTTLS K3G500PA26C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm
4x90°
6 Ø10 (4x) 15°
4
Ø585
Accesories
Ø11 (8x)
0.5
519.5±3 580
622
630
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 281)
6 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0°
Ø355+2
Ø232
Ø585
4
1 M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 Ø275
5
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90°
Ø10 (4x) 5 15°
1
3
Ø585
Ø11 (8x)
4
Ø440 15 M20x1.5 (3x) 2
401±2.5 551
471±3 580
630
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø355 +2
Ø585
Ø232
Information
1
156 3
282 Ø252 0.5
403 2 5 Ø275
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
2 M10 (6x)
70
6x6
0°
Ø355+2
Ø232
Ø585
4
1
M20x1.5 (3x)
156 3
282 Ø252 ±0.5
336 ±2 5
Ø275
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
Ø9 (4x) 5 15°
1
3
Ø585
Ø11 (8x)
4
Ø440 15 M20x1.5 (3x) 2
401±2.5 551
471±3 580
630
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid
E VBH0500PTTPS K3G500PB24W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø9 (4x) 15° Ø9 (16x)
225
1
225
3
225
Information
2
Ø440 20
4
899 40
514
651
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
E VBH0500PTTPS K3G500PB24W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø9 (4x) 15° Ø9 (16x)
225
1
225
Accesories
225
2
Ø440 20
4
899 40
514
Technology
651
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 281)
5 Mounting holes: for FlowGrid
2 M10 (6x)
113
6x6
0°
Ø355 +2
Ø280
Ø585
5
M20x1.5 (2x)
1 3
156 M25x1.5
282 4
408 ±2 Ø304 ±0.5
Ø324
5
1 Accessory part: Inlet ring 64025-2-4013 with pressure tap (k-factor: 281) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm
4x90°
6 Ø8 (4x) 15°
4
Ø585
Ø11 (8x)
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 281)
6 Mounting holes: for FlowGrid
28.09.2020 11:57:39
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 80 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
4
1200 C 4
B 4
1000 3
4
4
33
A
800
3
600
22 2
2
400 2
200
1 1 1cfm
pfs
qv 2000 4000 6000 8000 10000 12000 14000 16000 18000 m³/h
Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal PFC
VBS0560PTTPS R3G560PB22C1
fan active ❶ 400 1470 1800 2,60 96
❷ 400 1470 2710 3,94 87
A ❸ 400 1470 3060 4,40 79 -25..+40 IP 55 RP1)
Information
Centrifugal
VBS0560PTTPS R3G560PB3102
fan ❶ 400 1700 2520 3,89 103
❷ 400 1700 3830 5,84 92
B ❸ 400 1700 4400 6,60 84 -40..+40 IP 55 RP5)
Reso-
VBS0560PTTPS R3G560PB3165 Centrifugal nance-
fan sensor
Reso-
VBH0560PTTPS K3G560PB31W5 Cube nance-
(FanGrid) sensor
Centrifugal
VBS0560PTTRS R3G560PC0401
fan ❶ 400 1760 2790 4,36 101
❷ 400 1760 4250 6,52 92
D ❸ 400 1760 5000 7,70 84 -25..+40 IP 55 RP1)
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
2 M10 (6x)
113
6x6
0°
Ø398.2+2
Ø280
Ø655
5
1
175 M20x1.5 (2x) 3
314 4 M25x1.5
370.5±2 Ø304 ±0.5
6
Ø324
1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm
A VBH0560PTTPS K3G560PB22C1 (EC centrifugal module with support bracket and PFC, active) Dimensions in mm
4x90°
15°
6 Ø10 (4x)
1
4
Ø655
M25x1.5
Ø11 (8x)
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 348)
6 Mounting holes: for FlowGrid
2 M10 (6x)
70
6x6
0
Ø398.2 +2
Ø655
Ø232
Information
1
174.6 3
314 Ø252 0.5
433 2 6 Ø275
1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
2 M10 (6x)
70
6x6
0°
Ø398.2+2
Ø232
Ø655
4
1 M20x1.5 (3x)
174.6 3
314.3 Ø252 ±0.5
366 ±2 Ø275
6
1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90°
Ø10 (4x) 5 15°
1
3
Ø655
Ø11 (8x)
4
Ø545 15 M20x1.5 (3x) 2
436.5±2.5 555
506.5±3 750
800
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 348)
5 Mounting holes: for FlowGrid
C VBH0560PTTPS K3G560PB31W3 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø10 (4x) 15° Ø9 (16x)
250
1
250
3
250
Information
2
Ø545 20
4
999 40
550
722
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
C VBH0560PTTPS K3G560PB31W5 (EC centrifugal module with cube design / FanGrid) Dimensions in mm
4x90°
5 Ø10 (4x) 15° Ø9 (16x)
250
1
250
Accesories
250
2
Ø545 20
4
999 40
Technology
550
722
Contacts
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
2 Cable gland M20 x 1.5: Cable diameter min. 4 mm, max. 10 mm, Tightening torque 4 ± 0.6 Nm
3 Tightening torque: 1.5 ± 0.2 Nm
4 Inlet ring: with pressure tap (k-factor: 348)
5 Mounting holes: for FlowGrid
2 M10 (6x)
113
6x6
0°
Ø398.2+2
Ø280
Ø655
5
1 M20x1.5 (2x)
175 3 M25x1.5
314 4
472.5±2 Ø304 ±0.5
Ø324
6
1 Accessory part: Inlet ring 64030-2-4013 with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
5 Tightening torque: 3,5±0,5 Nm
4x90°
Ø10 (4x) 6 15°
1
4
Ø655
Ø11 (8x)
M25x1.5
5
Ø545 15 M20x1.5(2x) 2
544.5±2 3
658 ±3 750
792
800
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Cable diameter: min. 9 mm, max. 16 mm, Tightening torque 6±0,9 Nm
4 Tightening torque: 3,5±0,5 Nm
5 Inlet ring: with pressure tap (k-factor: 348)
6 Mounting holes: for FlowGrid
28.09.2020 11:57:53
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 88 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
1600
3
6
4
1400 B
1200
3
1000
A 4
4
800 2
3
600
2
2
400 2
200
1 1 1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0630PTTRS R3G630PC0803
fan ❶ 400 1500 2295 3,65 93
❷ 400 1500 3520 5,38 86
A ❸ 400 1500 4250 6,50 82 -40..+40 IP 55 RP5)
Information
Centrifugal
--- ---
fan ❶ 400 1750 3735 5,89 99
❷ 400 1750 6000 9,22 90
B ❸ 400 1750 7060 10,80 86 -40..+40 IP 55 RP1)
Centrifugal
--- ---
fan ❶ 400 1950 5080 8,40 105
❷ 400 1950 8400 13,19 96
C ❸ 400 1950 9780 15,20 89 -40..+40 IP 55 RP1)
Accesories
Technology
Contacts
2 M10 (6x)
6x6
70
0°
Ø446.8+2.5
Ø232
Ø716
4
M20x1.5 (3x)
1 3
190.6
333.5 Ø252 ±0.5
384 ±3 Ø275
10
1 Accessory part: Inlet ring 64045-2-4013 with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90°
5 Ø10 (4x) 15°
1
3
Ø716
Ø11 (8x)
4
Ø545 15 M20x1.5 (3x) 2
467.5±2.5 750
537.5±3 792
800
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 438)
5 Mounting holes: for FlowGrid
28.09.2020 11:58:00
EC centrifugal fans - RadiPac · Edition 2020-08
273.7
2 5
M10 (4x)
260
M20x1.5 (2x) 3
4 M25x1.5
676
4x90°
6 Ø10 (4x) 45°
7
Ø545
1
Ø9 (16x)
EC centrifugal fans - RadiPac · Edition 2020-08
250 20
600 532.7
666 663.7
760
1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
301.9
2
5
M10 (4x)
278.8
M20x1.5 (2x) 3
4 M25x1.5
676
Information
4x90°
6 Ø10 (4x) 45°
7
Ø545
1
Ø9 (16x)
1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
Accesories
Technology
Contacts
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
on Page 94 Drawings
■ Mode: Continuous operation (S1)
on Page 152 Accesories ■ Mounting: Maintenance-free ball bearings
on Page 164 Connection diagrams and technical features
Further Information
on Page 180 Technical parameters & scope
More at www.ebmpapst.com/worldwide www.ebmpapst.com/radipac
■ Information about touch current, electrical
connection, degree of protection, insulation
class, environmental protection class, EMC
standards as well as standards and approvals
in. wg
Pa
1400
3
4
1200
B
1000 A 3
4
4
800
2
3
600
2
2
400
2
200
1 1 1
pfs
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 cfm
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0710PTTRS R3G710PC0503
fan ❶ 400 1150 1950 3,05 83
❷ 400 1150 3195 4,90 81
A ❸ 400 1150 3750 5,70 78 -40..+40 IP 55 RP5)
Information
Centrifugal
--- ---
fan ❶ 400 1430 3730 5,88 89
❷ 400 1430 5785 8,90 86
B ❸ 400 1430 7050 10,70 84 -40..+40 IP 55 RP1)
Centrifugal
--- ---
fan ❶ 400 1680 5995 9,70 91
❷ 400 1680 9630 15,00 87
C ❸ 400 1680 11450 17,70 85 -40..+40 IP 55 RP1)
Accesories
Technology
Contacts
2 M10 (6x)
6x6
70
0
Ø503.6+2.5
Ø232
Ø806
4
M20x1.5 (3x)
1 3
214.9
374.9 Ø252 0.5
426 2 Ø275
10
1 Accessory part: Inlet ring 71075-2-4013 with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 2±0,3 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90 880
5 Ø10 (4x) 45 600
1
3
Ø806
Ø11 (12x)
4
Ø630 25 M20x1.5 (3x) 2
527.5 2.5 777
597.5 3 960
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 2±0,3 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 545)
5 Mounting holes: for FlowGrid
28.09.2020 11:58:09
EC centrifugal fans - RadiPac · Edition 2020-08
268.4
2
M10 (4x)
350.8
5
M20x1.5 (2x) 3
876 4 M25x1.5
4x90°
6 Ø10 (4x) 45° 7
Ø9 (12x)
250
Ø630
786
1
EC centrifugal fans - RadiPac · Edition 2020-08
Ø11 (12x)
600 40
880 618.2
960 749.2
1 Inlet ring: with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
239.6
2
5
451.6
M10 (4x)
M20x1.5 (2x)
3 M25x1.5
4
876
Information
4x90°
6 Ø10 (4x) 45° 7
Ø9 (12x)
250
786
Ø630
600 40
880 682.2
960 821.2
1 Inlet ring: with pressure tap (k-factor: 545) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
Accesories
Technology
Contacts
Material/surface
■ Support bracket: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
EC centrifugal fans - RadiPac · Edition 2020-08
4
1400 C
B
1200
4
3
1000
4
3
800
A
600 2
4
2
2
400 3
200 2
1 1 1 cfm
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
VBS0800PTTRS R3G800PC0203
fan ❶ 400 845 1520 2,42 80
❷ 400 845 2235 3,47 77
A ❸ 400 845 2800 4,30 74 -40..+40 IP 55 RP5)
Information
Centrifugal
--- ---
fan ❶ 400 1215 4250 6,64 89
❷ 400 1215 6890 10,55 85
B ❸ 400 1215 7950 12,10 83 -25..+40 IP 55 RP1)
Centrifugal
--- ---
fan ❶ 400 1370 6370 10,26 91
❷ 400 1370 9600 14,99 88
C ❸ 400 1370 11300 17,50 85 -25..+40 IP 55 RP1)
Accesories
Technology
Contacts
2 M10 (6x)
6x6
0
70
Ø566.3+3
Ø232
Ø909
4
M20x1.5 (3x)
1
244.3 3
418.8 Ø252 0.5
471.3 2 Ø275
20
1 Accessory part: Inlet ring 80075-2-4013 with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
not included in scope of delivery (Dimensions: see "Accessories" chapter) Installation position: Shaft horizontal or
2 Max. clearance of screw: 20 mm rotor on bottom, rotor on top on request
3 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
4 Tightening torque: 1,5±0,2 Nm
4x90
45
Ø9 (4x) 5
Ø 75
0
1
Ø909
Ø11 (16x)
3
4
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
or Rotor on bottom, rotor on top on request
2 Cable diameter: min. 4 mm, max. 10 mm, Tightening torque 4±0,6 Nm
3 Tightening torque: 1,5±0,2 Nm
4 Inlet ring: with pressure tap (k-factor: 695)
5 Mounting holes: for FlowGrid
28.09.2020 11:58:17
EC centrifugal fans - RadiPac · Edition 2020-08
307.6
M10 (4x) 2
420.4
M20x1.5 (2x)
3 M25x1.5
4
876
4x90°
6 Ø9 (4x) 45° 7
Ø9 (12x)
250
786
Ø750
1
EC centrifugal fans - RadiPac · Edition 2020-08
9.5
Ø11 (12x)
600 40
880 727
960 858
1 Inlet ring: with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
258.4
2
491.6
M10 (4x)
M20x1.5 (2x) 3
4 M25x1.5
876
Information
4x90°
6 Ø9 (4x) 45°
7
Ø9 (12x)
250
Ø750
786
600 40
880 741
960 880
1 Inlet ring: with pressure tap (k-factor: 695) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
Accesories
Technology
Contacts
Material/surface
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades: 5
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
A sheets.
800 3 =max.
3
700 4
2.5
600
3
500
2
400
1.5
300 2
1
200
0.5
100
1cfm
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
--- ---
fan ❶ 400 750 3540 5,63 84
❷ 400 750 5485 8,49 80
A ❸ 400 750 6340 9,80 77 -25..+40 IP 55 RP1)
Information
Subject to change Values set in blue are nominal data at operating point with maximum load.
277.9
2
5
M10 (4x)
465.2
M20x1.5 (2x) 3
4 M25x1.5
1096
4x90°
6 Ø9 (4x) 45° 7
Ø 960
Ø9 (20x)
1036
250
750
1
EC centrifugal fans - RadiPac · Edition 2020-08
Ø11 (12x)
800 30
1100 742.1
1180 873.1
1 Inlet ring: with pressure tap (k-factor: 1200) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 4 ± 0.6 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
Information
EC centrifugal fans - RadiPac · Edition 2020-08
Information
400 - 500 112
Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics and a motor enclosure.
Impeller made of aluminum, with 7 backwards-curved, con- Support structure, ready to install, for wall mounting.
tinuously welded blades; flow-optimized inlet ring made of Struts made of extruded aluminum profile. Mounting
galvanized sheet steel with pressure test nipple. plate made of galvanized sheet steel. Ready-made intake
nozzle for external air supply DN 100. Pre-installed, flexible
Motor-impeller in accordance with DIN ISO 21940, stati-
air hose between motor capsule and nozzle plate; easily
cally and dynamically balanced on two planes to balancing
replaceable; good mechanical resistance, flame retardant
grade G 6.3.
in accordance with UL 94 V-0. Easy cleaning and inspection
in accordance with EN 16282.
EC centrifugal fans - RadiPac · Edition 2020-08
Technical data:
Information
Air flow qV = _________________________________ m3/h, cfm
Line frequency f = 50 / 60 Hz
Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)
Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)
Accesories
Weight of fan m = _________________________________ kg
Technology
Contacts
Material/surface
■ Housing: Steel, painted black
■ Support plate: Sheet steel, galvanized
■ Spacer: Aluminium
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
Mechanical characteristics
■ Number of blades: 7
■ Direction of rotation: anticlockwise seen
the shaft
■ Installation position: See product drawing
■ Mode: Continuous operation (S1)
■ Mounting: Maintenance-free ball bearings
EC centrifugal fans - RadiPac · Edition 2020-08
3 =max.
1400
4
1200
4
1000 4 3
4
3
800 3 C
600 2 2
2
2
400 A
200 1 1 1
B
pfs
Degree of protection
Sound power level
Min. Gegendruck
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) Pa °C
Type Part number Fan type
Information
❶ 400 2040 2010 3,16 88
Centrifugal ❷ 400 2040 2560 3,96 85
B VBH0450NTTLS K3G450AQ23K1
module ❸ 400 2040 2780 4,30 84 200 -40..+60 IP 54 RP4)
❹ 400 2040 2295 3,57 86
Accesories
Technology
Contacts
A VBH0400NTTLS K3G400AQ27K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm
500 533±3
450 518±3 441
Ø370 251
6 10
X
45.5
Ø11 (8x)
Y
10
9 8 1 7 (9x)
420 11
Y 3
4 M20x1.5 (2x)
Z X
2
EC centrifugal fans - RadiPac · Edition 2020-08
M20x1.5 (2x)
Z
1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture
B VBH0450NTTLS K3G450AQ23K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm
630 562±3
580 547±3 441
Ø470 251 15
6 10
60.5 X
Ø11 (8x)
Y
725
10
Information
9 8 1 7 (9x)
492 11
Y 3
4 M20x1.5 (2x)
Z X
1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)
Accesories
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture
Technology
Contacts
C VBH0500NTTLS K3G500AP28K1 (EC centrifugal modules - RadiPac for the food service sector) Dimensions in mm
630 574±3
580 559±3 441
Ø470 251
6 10
60.5 X
Ø11 (8x)
Y
10
9 8 1 7 (9x)
492 11
Y 3
4 M20x1.5 (2x)
X
EC centrifugal fans - RadiPac · Edition 2020-08
Z 2
M20x1.5 (2x)
Z
1 Installation position: Shaft horizontal (only fit air hose at bottom as illustrated !) or rotor on bottom
2 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 2.5 ± 0.4 Nm
3 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
4 Cable gland: Cable diameter min. 8 mm, max. 12 mm, Tightening torque 1.8 ± 0.3 Nm
Y Housing: opened
Z Terminal box: Pin assignment see connection diagram
5 Tightening torque: 3 ± 0.5 Nm
6 Customer ventilation port: DN 100
7 Tightening torque: 3.5 ± 0.5 Nm
8 Inlet ring: with pressure tap (k-factor: 188)
9 Spiral hose: Ø 80 mm, PVC - coated polyester fabric (self-extinguishing)
10 Remove caps: prior to start-up
11 Installation aperture
28.09.2020 11:58:33
EC centrifugal fans - RadiPac · Edition 2020-08
Information
355 - 630 122
Direct-drive single inlet centrifugal fans with backwards-curved high-performance centrifugal impellers with radial
diffusers, mounted on a GreenTech EC external rotor motor with integrated control electronics.
Impeller made of aluminum, with 5 backwards-curved, con- Any work required for isolation from structure-borne noise
tinuously welded, blades; flow-optimized inlet ring made of to be performed by the customer. Fan satisfies the applica-
galvanized sheet steel with pressure test nipple. ble EMC guidelines and requirements with regard to circuit
feedback (for specific information, see the respective data
Motor impeller statically and dynamically balanced on two
sheet). Documentation and marking conform to the appli-
planes to balancing grade G 6.3 (motor size 200 to balan-
cable EU Directives.
cing grade G 4.0) in accordance with DIN ISO 21940.
Reliable performance data, air performance measurements
EC centrifugal fans - RadiPac · Edition 2020-08
Technical data:
Information
Air flow qV = _________________________________ m3/h, cfm
Line frequency f = 50 / 60 Hz
Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)
Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)
Accesories
Weight of fan m = _________________________________ kg
Technology
Contacts
Material/surface
■ Support bracket (355,400): Steel, painted black
■ Support plate (355,400): Sheet steel,
galvanized
■ Support structure(560,630): Sheet steel,
galvanized
■ Inlet ring: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Number of blades (355,400): 5
■ Number of blades (560): 6
■ Number of blades (630): 7
EC centrifugal fans - RadiPac · Edition 2020-08
3
1500
6
1000 2 2 2
4
500 B
2
A C
1 1 1 1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Information
❶ 400 3700 3460 5,35 102
Support ❷ 400 3700 4915 7,50 97
B VBH400NTTPS K3G400HB4101
bracket ❸ 400 3700 6000 9,10 94 -40..+40 IP 55 RP9)
❹ 400 3700 5660 8,62 95
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
6 (4x)
4
1
Ø11 (4x)
M25x1.5
5
Ø345 1 M20x1.5 (2x) 2
15 3
275.1±2 421
388.6±3 450
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
EC centrifugal fans - RadiPac · Edition 2020-08
6 4x90°
Ø9 (4x) 35
1
4
Ø455
Ø11 (4x)
Information
M25x1.5
5 3
Ø440 15 M20x1.5 (2x) 2
323.8±2.5 450
437.3±3 492
500
1 Installation position: Shaft horizontal (Install support struts only vertically according to view!) Pin assignment: (see connection diagram)
Accesories
Technology
Contacts
247
5
2
M10 (4x)
M25x1.5
224
4
586
3
4x90° M20x1.5 (2x)
6 Ø10 (4x) 45° 7
Ø545
250
1
Ø9.5 (12x)
1
EC centrifugal fans - RadiPac · Edition 2020-08
1 250 40
566 422
670 561
1 Inlet ring: with pressure tap (k-factor: 348) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
228
2
5
M10 (4x)
327
4 M25x1.5
676 M20x1.5 (2x)
3
Information
4x90°
6 Ø10 (4x) 45° 7
Ø545
1
Ø9.5 (12x)
1 Inlet ring: with pressure tap (k-factor: 438) Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements: Tightening torque 40 Nm
3 Cable gland: Cable diameter min. 5 mm, max. 13 mm, Tightening torque 6 ± 0.9 Nm
4 Cable gland: Cable diameter min. 16 mm, max. 20.5 mm, Tightening torque 6 ± 0.9 Nm
5 Tightening torque: 3.5 ± 0.5 Nm
6 Mounting holes: for FlowGrid
7 Installation position: Shaft horizontal (motor support plate must stand upright!) or rotor on bottom,
rotor on top on request!
Accesories
Technology
Contacts
Explosion group
Protection level
Protection level
Protection level
protection level
Intrinsic safety
Equipment
acrylonitrile, hydrogen
enclosure
acetaldehyde)
3G ic IIA T1 Gc
Zone 2
Corresponding T2 Increased
Hardly ever, rarely
to Zone 2 protection
Zone 1
II 2G Ex db eb ib IIB T3 Gb Occasionally
I 1G ia IIC T4 Ga
Not available
Zone 0
Corresponding T5 Very high
Constantly, often
to Zone 0 T6 protection
Information
EC centrifugal fans - RadiPac · Edition 2020-08
Material/surface
■ Support structure: Sheet steel, galvanized
■ Inlet ring: Sheet aluminium
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium,
painted black
Mechanical characteristics
■ Number of blades: 7
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
EC centrifugal fans - RadiPac · Edition 2020-08
A sheets.
3 =max.
1400
4
1200 B
4 3
1000 4
C
4
3
4
800 D
3
4 3
600 2
E 3
2
2
400 2 2
2
200
1 1 1 1 1
pfs
qv 2000 4000 6000 8000 10000 12000 14000 16000 18000 m³/h
Measuring requirements
Air performance measured according to: ISO 5801, installation category A, with ebm-papst inlet ring without contact protection.
Intake-side sound level: LwA according to 13347, LpA measured at 1 m distance from fan axis. The values given are only applicable
under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation
from the standard configuration, the parameters must be checked in installed condition.
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Centrifugal
--- ---
fan ❶ 400 2550 2035 3,11 92
❷ 400 2550 2715 4,14 88
A ❸ 400 2550 3100 4,70 86 -40..+50 IP 44 RP6)
Information
Centrifugal
--- ---
fan ❶ 400 2040 1840 2,82 92
❷ 400 2040 2685 3,92 88
B ❸ 400 2040 2950 4,50 86 -40..+50 IP 44 RP6)
Centrifugal
--- ---
fan ❶ 400 1780 2010 3,03 94
❷ 400 1780 2640 3,95 87
C ❸ 400 1780 2970 4,50 83 -40..+50 IP 44 RP6)
Centrifugal
--- ---
fan ❶ 400 1130 1895 2,93 90
❷ 400 1130 2515 3,87 84
E ❸ 400 1130 2970 4,60 83 -40..+50 IP 44 RP6)
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
B-B
95.8
6 M4x20 (7x)
2.82
330.6
8 2.82
2 9
M25x1.5
Ø9 (4x)
3
X
4 M20x1.5
5
435 7 (2x)
1
10
Ø9 (4x)
EC centrifugal fans - RadiPac · Edition 2020-08
B
X
434 15
500 333.4
466
1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian
103.1
B-B 6 M4x20 (7x)
3.17
357
2
8 3.17
Ø9 (4x)
9
M25x1.5 3 M20x1.5
X
4
565 5
Information
7 (2x)
1
10
Ø9 (4x)
519 15
630 367.1
500
1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
Accesories
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian
Technology
Contacts
B-B
105.9
6 M4x20 (7x)
3.53
2
369
8 3.53
Ø9 (4x)
9
M25x1.5 M20x1.5
X 3
565 4
5
7 (2x)
B
1
10
Ø9 (4x)
EC centrifugal fans - RadiPac · Edition 2020-08
B
X
519 15
630 381.9
514
1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian
B-B
196.1
6 M4x20 (7x)
3.95
2
258.5
8 3.95
Ø9 (4x)
M25x1.5 3 M20x1.5
X
688 4
Information
5
7 (2x)
1
10
X
689 15
760 425.35
561
1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
Accesories
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian
Technology
Contacts
B-B
243.45
6 M4x20 (7x)
4.44
2 8 4.44
339.5
9
Ø9 (4x)
M25x1.5 3 M20x1.5
X 4
688 5
7 (2x)
1
10
EC centrifugal fans - RadiPac · Edition 2020-08
Ø9 (4x)
B
X
689 15
760 553.7
689
1 Inlet ring with pressure tap Pin assignment: (see connection diagram)
2 Mounting position for vibration-absorbing elements Installation position: Shaft horizontal (base
3 Cable gland: Cable diameter min. 10 mm, max. 16 mm, Tightening torque 6 ± 0.6 Nm, mounting only) or rotor on bottom, rotor on
standard value depending on cable top not permitted !
4 Screw plug: M20x1.5
5 Cable gland: Cable diameter min. 10 mm, max. 14 mm, Tightening torque 6 ± 0.6 Nm
standard value depending on cable
6 Terminal box fastening screws: Tightening torque: 3.5 ± 0.5 Nm
7 Ground connection point: M8 (Functional ground for electrostatic discharge, no protective earth),
do not unfasten the nut provided, contact is established by way of another nut
8 Axial gap dimension
9 Radial gap dimension
10 Additional nameplate and warning sticker: in Russian
Information
EC centrifugal fans - RadiPac · Edition 2020-08
Information
250 - 400 142
Direct-drive dual-inlet centrifugal fans with backward-curved high-performance centrifugal impellers mounted on a
GreenTech EC external rotor motor with add-on control electronics.
Scroll housing made of galvanised sheet steel with bolted Fan satisfies the relevant EMC regulations and require-
-on adjustable mounting bracket, optimised step diffuser ments with regard to circuit feedback; documentation and
in discharge for low-noise operation, connection flange on marking conform to the applicable EU directives
pressure side.
Reliable performance data, air performance measurements
on inlet-side chamber test rig in accordance with ISO 5801
Aluminium impeller with 7 backward-curved, offset, conti-
and DIN 24163, noise measurements in low-reflection
nuously welded blades. Flow-optimised inlet nozzle made
acoustic test chamber as per DIN EN ISO 3745.
of galvanised sheet steel.
EC centrifugal fans - RadiPac · Edition 2020-08
Technical data:
Information
Air flow qV = _________________________________ m3/h, cfm
Line frequency f = 50 / 60 Hz
Sound power level LWA (A, in) = __________ / LWA (A, out) = __________ dB(A)
Sound pressure level (at 1 m) LPA (A, in) = __________ / LPA (A, out) = __________ dB(A)
Accesories
Weight of fan m = _________________________________ kg
Technology
Contacts
Material/surface
■ Housing: Sheet steel, galvanized
■ Impeller: Sheet aluminium
■ Rotor: Painted black
■ Electronics housing: Die-cast aluminium
Mechanical characteristics
■ Motor suspension: Motor mounted with
brackets on one side
■ Direction of rotation: Clockwise viewed toward
rotor
■ Installation position: See product drawing
■ Condensation drainage holes: Rotor side
■ Mode: Continuous operation (S1)
■ Mounting: Maintenance-free ball bearings
EC centrifugal fans - RadiPac · Edition 2020-08
3 =max.
1600
6
1400 4
1200 4
4
1000 3
4
4
800 3 4
3
600 3 3
2
2
400 2 2
2 2
200
E
B
A C D
1 1 1 1 1
pfs
Degree of protection
Sound power level
Nominal voltage
Operating point
Conn. diagram
Max. Input
Max. Input
power Ped
current I
ambient
Speed n
temp.
Perm.
LwA
Curve
Nominal voltage range 3~380-480 V AC, 50/60 Hz VAC rpm W A dB(A) °C
Type Part number Fan type
Moun-
VCD0250FTPMS D3G250GG0901 RadiFit ting ❶ 400 3850 1610 2,57 96
bracket
❷ 400 3850 1765 2,79 94
A ❸ 400 3850 1810 2,90 91 -25..+40 IP 54 RP8)
Information
Moun-
VCD0280FTPMS D3G280GG1001 RadiFit ting ❶ 400 2900 1190 1,98 92
bracket
❷ 400 2900 1295 2,10 89
B ❸ 400 2900 1320 2,10 86 -40..+40 IP 54 RP8)
Moun-
VCD0310FTRNS D3G310GG0501 RadiFit ting ❶ 400 3140 2825 4,35 97
bracket
❷ 400 3140 3095 4,74 95
C ❸ 400 3140 3180 4,90 91 -25..+40 IP 54 RP8)
Moun- ❹ 400 3140 2810 4,32 90
VCD0310FTRNS D3G310GG0504 RadiFit ting
frame
Moun-
VCD0400FTRNS D3G400GG0401 RadiFit ting ❶ 400 1920 2170 3,39 91
bracket
❷ 400 1920 2380 3,70 88
E ❸ 400 1920 2380 3,70 85 -25..+40 IP 54 RP8)
Moun- ❹ 400 1920 2160 3,38 84
VCD0400FTRNS D3G400GG0404 RadiFit ting
frame
Subject to change Values set in blue are nominal data at operating point with maximum load.
Accesories
Technology
Contacts
A VCD0250FTPMS D3G250GG0901 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm
140 140
352
347
10.5
Ø7
14
224
310 12
M20x1.5 (2x) 3
432 379
205 352
4 Ø7.5(12x) Ø9
1
322
161
X
322
381
107
EC centrifugal fans - RadiPac · Edition 2020-08
489
Ø166
X
4
220
180
326
376
B VCD0280FTPMS D3G280GG1001 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm
140 140
386.5
391
10.5
14.5 Ø7
224 12
Information
M20x1.5(2x) 3
310
475 418
225 391
4 Ø7.5(12x) Ø9
181.3
361
X
362.6
419.6
121.5
X
4
243
180
365
415
Accesories
Technology
Contacts
C VCD0310FTRNS D3G310GG0501 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm
2
440.2
(220.1)
8.5
14
280
12.65
1 404
202
X
463
404
138
EC centrifugal fans - RadiPac · Edition 2020-08
600
Ø212
X 4
258
90
270
408.5
465.5
C VCD0310FTRNS D3G310GG0504 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm
2
437.6
(218.8)
Ø10.5
280 106
15.25
Information
492 M20x1.5 (2x) 3
531 461.5
246 434
4 Ø9 Ø7.5 (16x)
1
404
202
X
463
404
138
578
90
270
408.5
468.5
Accesories
Technology
Contacts
D VCD0355FTRNS D3G355GG0301 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm
2
489.2
(244.6)
14 8.5
280
12.65
355
380 M20x1.5 (2x) 3
592 510.5
271 483
4 Ø9 Ø7.5(16x)
1 453
226.5
X
512
453
156
670
EC centrifugal fans - RadiPac · Edition 2020-08
Ø239
X
4
287
90
270
457.5
514.5
D VCD0355FTRNS D3G355GG0304 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm
2
495.6
(247.8)
Ø10.5
10.75
355 97
549
Information
M20x1.5 (2x) 3
593 510.5
271 483
4 Ø9 Ø7.5(16x)
1 453
226
X
511.6
453
156
656
90
270
457.5
517.5
Accesories
Technology
Contacts
E VCD0400FTRNS D3G400GG0401 (EC centrifugal fan - RadiFit with mounting bracket) Dimensions in mm
2
543
271.5
190 8.5
14
280
12.65
M20x1.5 (2x)
355
3
110 380
655 564.5
300 537
4 Ø9 Ø7.5 (20x)
253.5
507
X
565.6
507
178
750.2
EC centrifugal fans - RadiPac · Edition 2020-08
Ø271
X 4
318
180
360
511.5
568.5
E VCD0400FTRNS D3G400GG0404 (EC centrifugal fan - RadiFit with mounting frame) Dimensions in mm
2
550.6
275.3
Ø10.5
Information
355 129.5 M20x1.5 (2x)
10.25
614 3
662 564.5
300 537
4 Ø9 Ø7.5 (20x)
1 507
253.5
565.6
X
507
178
738
180
360
511.5
571.5
Accesories
Technology
Contacts
Accesories
FlowGrid air inlet grill In order to minimize the negative impact of the
ØB ØC ØE S H N* installation situation, ebm-papst offers the FlowGrid
Part number Fan size (mm) (mm) (mm) (mm) (mm) (Nm) air-inlet guard shown here. It is installed on the intake
20280-2-2957 250, 280 280 245-261 4,5 3,5 40 2±0,5 side of the fan and effectively reduces the noise
25310-2-2957 310 315 288-292 5,5 3,5 49 2±0,5 generated by the fan. Particularly annoying, low-fre-
00400-2-2957 355 370 334-346 4,5 3,5 56 2±0,5 quency noises are reduced efficiently.
35505-2-2957 400, 450, 500 470 440 9,0 3,5 71 10±2
00630-2-2957 560, 630 580 545 10 3,0 90 10±2
The level of noise reduction is dependent on the
50710-2-2957 710 666 630 10 3,0 106 10±2
installation situation, which is why no generally
63000-2-2957 800 785 750 10 3,0 125 10±2
applicable data is possible here.
Subject to change * Recommended tightening torque for fastening screws
If you need an
installation guide
Accesories
or more information
about the dimensions,
go to:
www.ebmpapst.com
Technology
/flowgrid-manual
or scan the
QR code below:
Contacts
E S
ØC H
ØB
Intake finger guard for backwards-curved centrifugal fans (according to EN ISO 13857)
a b d e
Part number Fan size Version Strut division
(mm) (mm) (mm) (mm)
79280-2-4039 250,280 1 280 4,5 227 2,8 4 x 90°
79310-2-4039 310 1 325 4,5 271 2,8 4 x 90°
79355-2-4039 355 1 345 4,5 308 2,8 4 x 90°
79400-2-4039 400 2 390 8,5 343 2,8 3 x 120°
79500-2-4039 450,500 2 445 8,5 417 2,8 3 x 120°
79560-2-4039 560 2 490 8,5 466 2,8 3 x 120°
79630-2-4039 630 3 600 8,5 551 3,9 3 x 120°
79710-2-4039 710, 800 3 700 8,5 651 3,9 3 x 120°
79900-2-4039 1000 4 850 8,5 801 3,9 6 x 60°
Subject to change
e b
b
Version 1 Version 2
Accesories
e
Ød Ød
Øa Øa
e b
b
Version 3 Version 4
e
Ød Ød
Øa Øa
Inlet rings with / without measuring device to determine the air flow for backwards-curved centrifugal fans
Part number Part number Part number
Fan size Dimensions / drawing
without measuring device with one pressure tap with piezometer
96350-2-4013 96355-2-4013 96345-2-4013 250 see Page 157
28000-2-4013 28004-2-4013 28003-2-4013 280 see Page 157
31470-2-4013 31475-2-4013 31480-2-4013 310 see Page 157
35670-2-4013 35675-2-4013 35680-2-4013 355 see Page 157
40073-2-4013 40078-2-4013 40083-2-4013 400 see Page 158
45070-2-4013 45075-2-4013 45080-2-4013 450 see Page 158
63072-2-4013 64025-2-4013 64002-2-4013 500 see Page 158
63071-2-4013 64030-2-4013 64001-2-4013 560 see Page 158
63070-2-4013 64040-2-4013 64000-2-4013 630 see Page 159
71070-2-4013 71075-2-4013 71080-2-4013 710 see Page 159
80070-2-4013 80075-2-4013 80080-2-4013 800 see Page 159
Subject to change
with
piezometer:
Technology
Contacts
0°°
x990
44x
RR11
77
R1
R3333
RR53
8
R 55.5
53
R35
R
Ø167.25
Ø176,7
Ø176,7
Ø161.3
Ø182
Ø182
Ø280
Ø280
Ø280
Accesories
R2
R
4
20
R 47
R74,5
R 58
R 63,5
,5
Ø211,7
Ø217
Ø350
Ø370
Ø246
Ø239
R2
5,5
R 49,5
8
R 55
R 78,5
R 87,5
)
3x
2(
39
4x90°
Ø303,4
Ø270,9
6x60°
Ø396
Ø480
Ø312
Ø278
EC centrifugal fans - RadiPac · Edition 2020-08
4x90°
Fan size 500: Fan size 560:
x)
(4
Ø9
45° Ø9(6x)
° 0°
6x60 6x6
R3
R2
0
15
R 60
R 95
8
°
R 49
)
R 87
Accesories
(6x
Ø9
Ø388,8
Ø515
Ø380
Ø470
Ø346
Ø337
15°
505
Technology
2 Ø490
82
2 Ø440
75 Ø445
Contacts
(6x
)
4x
0°
4x9
0°
R3
6x6
R 50.4
R4
7
R66.6
R355
R 114
7.9
R 72
Ø10 (4x)
15°
Ø492.6
Ø470.3
Ø720
Ø436.8
Ø427
Ø624
Ø545
2 Ø630
2 Ø600
117 Ø700
98.5
Ø9 (6x)
R5
4
Accesories
R 75
R 56.8
R400
710
Ø555.3
Ø529.7
Ø720
2.5 Ø700
131
M10 – Packaging:
Part numbers refer to one set consisting of 4x spring elements each.
Supplied in a box.
* Unloaded
M10
M10 – Packaging:
Part numbers refer to one set consisting of 4x rubber buffers, washers, and nuts each.
Supplied in a box.
18
40
(rpm) (mm)
M10
Technology
Attention:
The vibration absorbers recommended by ebm-papst are avai- The configuration of the unit in which the fan is installed can have
lable in a set of 4 pieces. The vibration absorbers are perfectly a strong influence on the fan‘s vibration characteristics, so
matched to their intended fans and the specified minimum speed. a vibration test always has to be performed after the fan has been
The installation and operation of several fans on one set of spring installed. The fan’s vibration characteristics must be tested under
elements is not allowed. all relevant operating conditions (such as speed, back pressure,
systemic fluctuations in back pressure) – when installed and in
During start-up, the fan has to pass through the speed range interaction with the complete system.
corresponding to the resonance frequency (below the minimum
speed). The vibrations caused by the fan’s residual imbalance are The maximum vibration severity may not exceed 3.5 mm/s, mea-
strongest within this speed range. This speed range must be pas- sured at the motor’s fastening pitch circle on the motor support
sed through as quickly as possible to avoid damage to the fan. plate in the direction of and perpendicular to the motor’s axis of
Operation below, close to or at the resonance frequency will rotation. Even when the vibration absorbers recommended by
destroy the fan! ebm-papst are used, their effectiveness must be tested in the
application. If vibration absorbers other than those specified are
When the fan is being operated, take care to ensure that the used, tests must be performed to determine how the resonance
fan’s speed does not go below the specified minimum speed. frequency, and thus the operating requirements, change.
This will prevent the fan from being operated continuously near
the resonance frequency. The specified minimum speed is always
for an individual fan without any influences from the system it is
installed in.
Accesories
Technology
Technical features:
• Control input 0-10 VDC / PWM • Locked-rotor protection / Soft start / Motor current limitation
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output 20 VDC (+/-20 %) max. 50 mA • PFC, passive (standard) or PFC, active (see product-specific catalog page)
• Output for slave 0-10 V max. 5 mA • Thermal overload protection for electronics/motor
• Input for sensor 0-10 V or 4-20 mA • Undervoltage/phase failure detection
• Operation and fault indicator • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)
KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain2 U
Ain2 I
+20V
GND
Aout
Din3
Din2
Ain1 U
Ain1 I
+10V
COM
GND
RS A
RS B
Din1
NO
NC
PE
L1
L2
L3
1 2 3 4 5 6 7 1 2 3 1 2 3
Technology
Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation / Alarm relay
• RS 485 MODBUS-RTU / PFC, passive • Undervoltage/phase failure detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator • External enable input/External 24 V input (parameterization)
• Integrated PI controller
KL 2 KL 1
5 6 7 8
Ain1 U
+10 V
Din1
NC
GND
RS A
RS B
PE
L1
L2
L3
C
1 2 3 4 1 2 3
7 Ain1 U Analog input 1 (set value) 0-10 V, Ri = 100 kΩ, adjustable curve; SELV
8 NC Status relay, floating status contact, break for failure
Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation
• RS 485 MODBUS-RTU / PFC, active • Undervoltage detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator
• Power limiter
• Alarm relay
Wire 1 Wire 2
0-10 V
+10 V
COM
GND
RSA
RSB
NC
PE
green/yellow blue black white 1 white 2 yellow brown white blue red
Technology
Technical features:
• Control input 0-10 VDC / PWM • Thermal overload protection for electronics/motor
• Output 10 VDC max. 10 mA • Motor current limitation / Alarm relay
• RS 485 MODBUS-RTU / PFC, passive • Undervoltage/phase failure detection
• Locked-rotor protection / Soft start • Control interface with SELV potential safely disconnected from supply
• Operation and fault indicator • External 24 V input (parameterization)
• Integrated PI controller
Wire 1 Wire 2
24 V IN
0-10 V
+10 V
COM
GND
RSA
RSB
NC
PE
PE
L2
L1
L3
green/yell. green/yell. black black black white 1 white 2 blue white brown yellow red
Technical features:
• Configurable inputs/outputs (I/O) • Voltage output 3,3-24 VDC, Pmax = 800 mW
• RFID - ISO 15693 compatible • RS 485 MODBUS-RTU / MODBUS V6
• Operation and fault indicator with LED • Thermal overload protection for electronics/motor
• Integrated PI controller • Undervoltage/phase failure detection
• Locked-rotor protection • Control interface with SELV potential safely disconnected from supply
• Soft start / Alarm relay • External 15-50 VDC input (parameterization)
• Motor current limitation
GND GND PE
L1
IO1 RSA LED
IO2 RSB L2
IO3 RSA PE
RFID L3
Vout RSB
CON1
NC COM
CON2
COM Status relay, floating status contact, contact rating 250 VAC / 2 A (AC1) min. 10 mA
reinforced insulation on supply side and on control interface side
NC Status relay, floating status contact, option 1: break for failure,
option 2: break for run monitoring error message
Technical features:
• Control input 0-10 VDC / PWM • Locked-rotor protection / Soft start
• Output 10 VDC max. 10 mA • RS 485 MODBUS-RTU / PFC, passive
• Output 20 VDC max. 50 mA • Thermal overload protection for electronics/motor
• Output for slave 0-10 V • Motor current limitation / Alarm relay
• Operation and fault indicator • Undervoltage/phase failure detection
• Integrated PI controller • External enable input/External 24 V input (parameterization)
• Input for sensor 0-10 V or 4-20 mA
KL 1 KL 2
HZ (not
HZ (not
Ain1 U
Ain2 U
Ain2 I
Ain1 I
+20 V
+10 V
COM
GND
Aout
Din2
Din3
Din1
used)
used)
RSA
RSB
NO
NC
PE
PE
L2
L1
L3
Technology
Technical features:
• Control input 0-10 VDC / PWM • Soft start / Motor current limitation
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output 20 VDC (+/-20 %) max. 50 mA • PFC, active / Power limiter
• Output for slave 0-10 V max. 5 mA • Thermal overload protection for electronics/motor
• Input for sensor 0-10 V or 4-20 mA • Undervoltage/phase failure detection
• Tach output • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)
KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain2 U
Ain2 I
+20V
GND
Aout
Din3
Din2
Ain1 U
Ain1 I
+10V
COM
GND
RS A
RS B
Din1
NO
NC
PE
L1
N
1 2 3 4 5 6 7 1 2 3 1 2
2 COM Status relay, floating status contact, changeover contact, common connection,
contact rating, max. 250 VAC / 2 A (AC1) min. 10 mA
3 NC Status relay, floating status contact, break for failure
5 +10V Voltage output 10 VDC,+10 V ± 3%,max.10 mA, power supply for external devices (e.g. pot), SELV
6 Ain1 I Analog input 1, set value: 4-20 mA, Ri = 100 Ω, adjustable curve,
only usable as alternative to input Ain1 U, SELV
7 Din1 Digital input 1: enable electronics,
enable: pin open or applied voltage 5-50 VDC, disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 VDC; SELV
8 Din2 Digital input 2: Switching parameter sets 1/2, according to EEPROM setting, the valid or used
parameter set can be selected via bus or via digital input DIN2.
Parameter set 1: pin open or applied voltage 5-50 VDC
Parameter set 2: bridge to GND or applied voltage < 1 VDC; SELV
Technology
Technical features:
• Control input 0-10 VDC / PWM • PFC, passive / Temperature derating
• Output 10 VDC (+10 %) max. 10 mA • RS 485 MODBUS-RTU
• Alarm relay / Soft start • EEPROM write cycles: 100.000 maximum
• Power limiter • Thermal overload protection for electronics/motor
• Motor current limitation • Undervoltage/phase failure detection
• Operation and fault indicator • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External 24 V input (parameterization)
NC L1
KL3
COM
L2 KL2
10V
0-10V L3
KL4 GND
RSA
RSB PE PE KL1
Technical features:
• Control input 0-10 VDC • Soft start / PFC, passive
• Output 10 VDC max. 10 mA • RS 485 MODBUS-RTU / Alarm relay
• Output for slave 0-10 V • Thermal overload protection for electronics/motor
• Motor current limitation • Undervoltage/phase failure detection
• Reverse polarity and locked-rotor protection • Control interface with SELV potential safely disconnected from supply
• Integrated PI controller • External enable input/External 24 V input (parameterization)
• Power limiter
KL 3 KL 2 KL 1
8 9 10 11 12 13 14
Ain1 U
+10V
Aout
COM
GND
RS A
RS B
Din1
NO
NC
PE
L1
L2
L3
1 2 3 4 5 6 7 1 2 3 1 2 3
enable: pin open or applied voltage 5-50 VDC, disable: bridge to GND or applied voltage < 1 VDC
reset function: triggers software reset after a level change to < 1 VDC; SELV
5 ---
6 ---
7 ---
8 ---
Technology
Correction values
for the air flow
Fan size 250 - 1000:
1,00
0,99
0,98
0,97
0,96
Correction factor for air flow
Technology
0,95
0,94
The correction values shown here were determined from an The new RadiPac fans are known to be less vulnerable to tight
extensive series of measurements taken on our own internal installation situations. For square cross sections that are
chamber test rig. Here, square and rectangular outflow cross greater than 1.7 x the impeller diameter, no deduction has to
sections were considered. This is why the hydraulic diameter be applied to the catalog curves.
was used to determine the correction values.
Airflow determination:
The differential pressure method compares the static pressure The pressure is tapped at 1 (4) point(s) on the circumference of
upstream of the inlet ring with the static pressure in the inlet ring. the inlet ring.
The airflow can be calculated from the differential pressure (bet- The customer connection consists of a built-in T-shaped
ween the static pressures) according to the following equation: hose fitting.
∆p = q V2 : k2
Technology
General performance parameters The service life of the insulation system is essentially governed by
the voltage level, the temperature and the ambient conditions such
Any deviations from the technical data and parameters described
as humidity and condensation.
here are listed on the product-specific data sheet.
Degree of protection The service life of the bearing system is primarily governed by the
thermal load on the bearings. For the majority of our products we
The type of protection is specified in the product-specific data use maintenance-free ball bearings which can be fitted in any ins-
sheets. tallation position. Sleeve bearings can alternatively be employed,
as described in the product-specific data sheets.
Insulation class
As a rough guide (depending on the general conditions), the ball
The insulation class is specified in the product-specific data sheets. bearings have a life expectancy L10 of approx. 40.000 hours of
operation at an ambient temperature of 40 °C.
Installation position
We will gladly provide you with a life expectancy calculation based
The mounting position is specified in the product-specific data on your specific usage conditions.
sheets.
Motor protection/thermal protection
Condensate discharge holes
Information on motor protection and thermal protection is provi-
Information on the condensate discharge holes is provided in the ded in the product-specific data sheets.
product-specific data sheets. The following protection methods are provided depending on the
type of motor and area of application:
Mode of operation
– Thermal overload protector, in-circuit or external
The mode of operation is specified in the product-specific data
sheets. – PTC with electronic diagnostics
– Impedance protection
Protection class – Thermal overload protector with electronic diagnostics
The protection class is specified in the product-specific data sheets. – Current limitation via electronics
If use is made of an external thermal overload protector, a commer-
Tightening torques for fan assembly cially available tripping unit must be connected by the customer for
Technology
Please consult your ebm-papst contact for questions about which shut-off. Motor protection conforming to the applicable standard
tightening torque to use. must be fitted for products not provided with a built-in thermal
overload protector and not protected against improper use.
Service life
Mechanical strain/performance parameters
The service life of ebm-papst products depends on two main
factors: All ebm-papst products are subjected to comprehensive testing in
conformity with the normative specifications and also incorpora-
– The service life of the insulation system
ting the extensive experience of ebm-papst.
– The service life of the bearing system
systems, telecommunications, household appliances, heating and operated at nominal voltage, with alternating current also at
systems, machinery and installations, drive engineering. nominal frequency, without any additional attachments such as a
Our products are not intended for use in the aerospace industry! guard grill.
As required by the standards, the air performance curves shown are
Legal and normative specifications referenced to an air density of 1,15 kg/m³.
The products described in this catalog are developed and manufac-
tured in accordance with the standards applying to the particular
product and, if known, in accordance with the conditions of the
particular area of application.
All sound measurements are taken in anechoic rooms with rever- Measurement set-up according to ISO 13347-3 and DIN 45635-38:
berant floor. ebm-papst acoustic test chambers meet the require- 10 measuring pointse
ments of accuracy class 1 as per DIN EN ISO 3745. d≥D
For sound measurement, the fans being tested are positioned in a h = 1,5d ... 4,5d
reverberant wall and operated at nominal voltage, with alternating Measurement area S = 6d² + 7d (h + 1,5d)
current also at nominal frequency, without any additional attach-
ments such as a guard grill.
1,5d
D
Technology
3d
2d
15
[dB(A)]
[dB]
The addition of 2 sound sources with the same level produces a
level increase of approx. 3 dB.
10
shown in the adjacent graph.
9
Example: There are 8 axial fans A3G800 on a condenser. According
to the data sheet, the sound pressure level of one fan is 75 dB(A).
The level increase determined from the graph is 9 dB. This means
that a total level of 84 dB(A) is to be expected for the installation.
5
0
1 2 3 4 5 6 7 8 9 10 15 20 25
3
[dB(A)]
The noise characteristics of two different fans can be predicted [dB]
on the basis of the sound values specified in the data sheet. This
is shown in the adjacent graph.
Increase in sound pressure / sound power level
axial fan A3G710 with 71 dB(A). The difference in level is 4 dB. The
level increase of approx. 1.5 dB can now be read off the graph. This
1,5
means that a total level of 76.5 dB(A) is to be expected for the unit.
1
0
0 4 8 12 16 20 24
Distance laws Difference in level with two sources of sound [dB]
[dB(A)]
The sound power level is not governed by the distance from the
noise source. By contrast, the sound pressure level decreases with
increasing distance from the sound source. The adjacent graph
0
[dB(A)]
shows the decrease in level under far fi eld conditions. Far field
[dB]
on far fields. The level in the far fi eld decreases by 6 dB each time
the distance is doubled. Different relationships apply in the near
Decrease in sound pressure level
-20
field of the fan and the level may decrease to a far lesser extent.
The following example only applies to far field conditions and may
-26
1 2 5 10 20 50 100
Distance [m]
[%]
[dB(A)]
[Pa]
Middle section of the air performance curve:
– Maximum efficiency
– Minimum noise
To the left and right of the middle section of the air performance
curve:
– Reduced efficiency
– Increasing noise
efficiency
optimum operating range
0
[dB]
The sound power level for changes in speed can be approximately
determined based on the adjoining diagram and the following
20
formula:
10
Modification in sound pressure level
Lw₁ = Sound power level after speed change
Lw₂ = Sound power level before speed change
0
n₁ = Changed speed
n₂ = Initial speed
-10
-20
Technology
Germany
ww.ebmpapst.com/contact
ebm-papst
Mulfingen GmbH & Co. KG
Bachmühle 2
74673 Mulfingen
Germany
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com