You are on page 1of 11
Product data sheet VAPODEST® eee AP 450 ve 450 WAP 200 MAP 300 NAP E00 pithouttitrator with titrator Mult Touch Sensitive Screen 7 ° ° Programmable addition H,80, Programmable addition H/0 Programmable addition NaOH J reagent Programmable reaction time Programmable distillation time Programmable staem power 10- 100% Programmable suction of ample waste Programmable suction of the receiver Selection of language Diffaront user lvels Optical and acoustical error messages Method data base Programmable methods Connection for external keyboard Connection for external PC-mouse ‘Automatic check of chemical reservir Kjeldatherm digestion tubes can be used! Kjeldahl flasks can be used Titration with external C6 ttrator possible Titrator included the delivery USB-interlace on the front side 1x 1x 1x 1x USB-interface onthe back 4x a ax 4x Ethernet-interfaceon the back 1x 1x 1x 1x RS-202 interface on the back = 1 1x 1x 1x Tubing set complete 1x 1x 1x 1x KJELOATHERM-digestion tube, 250/300ml 1x tx 1x 1x Butter solution pH 7, 250 ml Butter solution pH 4, 250 mi KCL slectrolite solution, 250 mi eevee eovcce eeccccce . (© = Standard configuration I= See digestion tubes and Kjeldahl-tlasks on page 3 Product data sheet VAPODEST® Order Informations VAPODEST® iy Rey (Coating water consumption Winial 2/577 2rsin 21817 21817 27519 Distillation time [min] 2-4 2-4 2-6 2-4 2-4 Recoveryrate%6) > 99,5 2995 2995; 3995 2995 Reproducibiliy 4] 4/1 HA a WA 4FA Detection init Nfimg) 1 04 04 o4 01 Nominatvoltage(VAC] 220/115 230/115 230/115 230/115 230/115, Frequency Hel 50-60 50-60 50-60 50-60 50-60 Nominal wattage (WI 2200, 2200 2200 7200 2200 Weight ig] 35 37 28 38 40) Dimensions W/D/Hmm) 527/390/ 697 527/390/497 527/390/497 527/390/497 527/390 /697 1 Inet. Titrator Cla eue) Version Standard, 230 Seanad 12.0530 12-0540 12.0550 12.0545 Version Acid resistant, 230 ent aeen| 2 s 12.0532 12-0542 12.0557 12.0567 Version Stand feereapeaee [mnrcix 12-0826 12-0678 12.0632 12.0836 complete with tubing et ia cela rasa AE (gre 0c? 12.0626 12.0690 12.0634 12-0638 Equipped with acd resistant pumps 1 special for dosing of phosphoric ac max. 85 % and hydruchloric acid max. 6% - more acids an request Product data sheet VAPODEST® Order information accessories and consumables CONSUMABLES AND ACCESSORIES Make sure to use only original C. Gerhardt spare parts in order to obtain the best possible results. These parts have been tested thoroughly for the operation with VAPODEST® in the C. Gerhardt application lab. Depending on sample type and sample quantity VAPODEST can use a lot of Kjeldahl-digestion tubes as well as Kjeldahl-flasks, All tubes are made of high standard Duran® material, veaa0 JELDATHERM®peston ube, mace 2070-109 teow KIO JGELOATHERN®-pesin ube mace ZOE mi consi arated a 250 mk Sena Bec TOELOMTHERN®-agesin ue 0 dind teasto. —KODIEO ———Amtneenton wed ms astt Kaba. atest tea ald teas KODIZOO———_Amtwaestion be 200m tak TGELDATHERN-agesion gs mio 100 mt 1 pes tee KOE TOELDATHERN® pains mice 0 ml thence salt at 10m eon TUELOMTHERN®-Oer, iv em calmed 0 ms 7S tao Kase Necetnst laengel feasts Koso Mant asst wih ergs neck ss tau KOI Itasca neck pee an veaoas smoos ve sean eats xq of ol of ~) *4 Mi M4 M UN = = z : = = roan veaoes ses01 seare sas aa 4 Pe of *y * | yo KA INS ENS = 7 a a 7 = Pago 3 Product data sheet VAPODEST® Order information accessories and consumables Insert racks made of stainless steel, best for collecting the single digestion tubes, e.g, for direct distillation 12.0269 E6625 Insert rack d:place for tubes 250 ml 12-0273 E6125 Insert rack 12-place for tubes 250 ml 12-0271 EGA Insort rack deplace for tubes 400 mil 12.0272 EG4B0 Insert rack 4-place for tubes 800 ml 12-0277 EG12-100. Insert rack 12-place for tubes 100 ml oon 100509 108 Tank level control for Reagent-storage tank, incl. cable labels fr clear identification, suitable for tanks withthe following dimensions: “= Height = mi, 130 mm. max, 2000 mm Filler neck = min. 640 mm... max. 50 mm 1005721 PAB ‘Tank level control for sample waste storage tank, incl. cable Tank ovel control 1005098 labels fr clear identification, suitable for tanks withthe following dimensions: Height =a tanks: Filler neck = min. @47 mm... max. @ 50 mm ustration 12-0560 NIV200._—_ Tank level control set for 2Reagent-tanks, Position in tank eee 2 Tank level control no, 1005098 12.0861 NINQ00.——_ Tank level control set fr 2 Reagent-tanks and 1 sample waste tank, consisting of += 2x Tank evel contro for reagent-tank no, 1005098 = 1x Tank level control for sample waste tank, no, 1008721 12.0562 NIVAO0.—_ Tank evel control set for 3 reagent-tanks and 1 sample waste tank, consisting of: 13. Tank evel contro for reagent-tank no, 1005099 ~1x Tank level control fr sample waste tank, no, 1008721 ge tan 100589 KANTO. Tank made of HOPE, 101. 1005850 -KAN20 Tank made of HOPE, 201. ' Product data sheet VAPODEST® Order information accessories and consumables 12-0351 Viten-connection stopper, normal size 12.0567 Viton-connection topper, ‘Special size for Buchi-Adapter 12-0382 Connection stopper VK, Ioversinic miro, special elton for {the use of micro digestion tubes 100 mt 12-0241 Kit for alcohol determination ‘Special for alcohol determination, easy to mount Wren 12.0568 Behl - Upgrade it, complete with 41x iton-comnection stopper, No, 12-0351 a 41x\iton-connection stopper, No. 12-0567 ‘x Adapter PP eee 2 12.0356 ET-KCL_pH-combined electrode KCL, require regulary filling with ket. 12-0355 ET-GEL__pli-combined electrode gel electrolyte, maintenance free Product data sheet VAPODEST® Order information accessories and consumables Order No. Type Description 1000178 Electrolyte solution KCL 000174 Bulfer solution pH & 1000177 Bulfer solution pH 7 Order No. Type Description 12.0556 Distribution head glass, standard version Eee Order No. Type Description 120581 Distillation condenser alss, standard version with connecting piece for vetitation valve 000036 Ventilation valve for distilaion condenser PP-Distribution head kit Order No. Type Description 120866 /PP-distribution heaé kit, compte wits 1 x P-Distribution head, No, 12-0553 1 xDitilation condenser, No. 12-0562 inl. Viton connection stopper and GL-screw caps Order No. Type Description ‘000394 Water inlet tube 10/17, 2m long, 90baF, 78x 1/2" 3/8 3/6 ‘0004+ Pvc-tubing, 8x 12mm 1000499 \erpren-tubing 8x 12 mm 1000567 PVC-pipe 400 mm long, 10.2 1,4 mm “Length needed when order Product data sheet VAPODEST® Order information accessories and consumables 1004320 1004321 1004322 1000358 1000355 1000367 ‘Screw eap GLA, nat white ‘Screw cap GL, nat. white ‘Screw cap GL 32, nat white Silicone seal GL 14with connection, straight Slicone-seal GL 18 Slicone-seal GL92 eee 12.0565 12.0569 “Titator T5000 for connection to VAPODEST® 450 Upgrade kt for connection trator T5000 ‘The upgrade kit contains al necessary accessories for the ‘subsequent conversion ofthe VAPODEST® 460, no, 12-0550, ‘complete incl Holder for receiver, pH-electrode, cable for electrode, tubings and connection cables, iting screws 12.0584 |SOdoc-CREATOR, Software to create documents \VAPODEST-data transfer via USB-stick toa PC to create and print out [SO 17025-compliant documents, Delivery incl. USB-stick Product data sheet VAPODEST® Order information support and service SUPPORT AND SERVICE In addition to its high quality instruments, C. Gerhardt offers comprehensive services to maintain the functionality and effeciency of your equipment. Erne ae are oO ABL-VAP ‘Setup and installation VAPODEST®: = connection ofthe system ~ easy performance check a MEB-VAP Mathod creation and guidance VAPODEST: Guidance and intense instruction of the system = Creation of fest method ~ applicative advice and support O la-var Installation Qualification VAPODEST® incl. documentation oO 0.vap (Operational Qualification VAPODEST® incl. documentation a PO.VAP Performance Qualification VAPODEST® incl. documentation O 0F-vAP Equipment qualification VAPODEST®, complete service package inc. = Setup and installation - Creation of 2 method and advice Complete 1 /00/ PQ nck. documentation “= VAPODEST®.Dacument folder Training document Certificate euch coca cart For detailed information on servicing and maintenance concepts, please contact your local authorised C. Gerhardt repre: sentative (cro ea ne anenn For detailed information on trainings and workshops, please contact your local authorised C. Gerhardt representative APPLICATION SERVICE Product data sheet VAPODEST® Order inorration application data sheet The following listed applications are examples from our comprehensive application data base, Please contact your local C. Gerhardt representative or write to application@agerhardt de to ask for one of the listed application data sheets or to ‘ask for an application which is not yet listed l t t i i i ( i ( tl wl i i w i i ( i i i ( q t i tl t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Selection Description Non Protein content in Meat Nitrogen in bread and rolls “otal Nitrogen in Raw Material for Breweries Solulable Nitrogen Content Wort Raw Protein Determination in Eggs. “otal Protein in Margarine Tomato puree and Ketchup Nitrogen in Milk and Dairy Products Nitrogen in Cream Protein in Mik Powder NNon-Protei in Milk and Dairy Products Raw Protein in Meat and Meat Products Raw Protein in Grain and Grain Products Raw Protein in Bear and Wort ace. to Lochner Total Nitragen in Sugar at very ow N-content Nitrogen in Starch Nitrogen in Figh and Fish Products Nitrogen in Chocolate “otal Protein in Fresh Yeast Raw Protein in Feed Volatile Acids in Wine Sulphur Diowde in Food Sorbie acid in wine WEN in Fish and Fich Products VieinatDiketones in Beer ‘Alcohol. Beverages and Intermediates Selection Description CCoagulated Nitrogen Nitrogen Determination in Fertilizers with Nitrate Fertilizers without Nitrate Content ‘Ammonium Determination in Fertilizers ‘Water soluable Ammonium nitrogen in Fertilizers Determination of Nitra and Ammonium Nitrogen fert Total Nitrogen in Xanthan Total Nitrogen in Water “otal Nitrogen in Soi Total Nitrogen in Grass and Plant Materia Total Nitrogen in Coal Phenol IndexinSolls and Water ‘Aenmonium in Solid Samples ‘Ammonium in Aqueous Samples Nitrate in Aqueous Samples and Elvates Total Cyanide in Water, Soil and Sludge Volatile Organic Acids in Studge Total Formaldehyde in Aminoplast Adhesive Product data sheet VAPODEST® ‘TABLE OF CONFIGURATION Please arrange the required system Eternal Quantity Order No. Type Description Cees ‘Quantity Order No. Type Description Ete ‘Quantity Order No. Type Description Send offer to: Customer Na Company Name ‘ddross Tet E-Mat Web Product data sheet VAPODEST® Votre revendeur : ®clou p 42 a 48 bd de Polangis - BP 260 94502 Champigny-sur-Marne - Cedex a 01 48 83 21 76 - & 0148835101 info@cloup.fr www.cloup.fr

You might also like