A key success factor for modern companies is transparency across all data levels. Data from all company divisions must be acquired and consolidated in order to optimize planning for production processes, establish safety measures to protect systems and machines, and save costs, for example. This objective entails a number of challenges, because
different standards, interfaces and communication options must be coordinated with each other. Networking areas that were previously examined separately, from the machine level to ERP systems and building management systems is very complex. OPC UA is a data transmission standardization that simplifies this consolidation. The Janitza UMG
801 energy measurement device offers various communication interfaces and enables direct data transmission to higher-level systems via OPC UA, eliminating the need for costly integration. The modularly expandable UMG 801 is ideally suited for the complete acquisition of an energy management system (e.g. ISO 50001).
You gain transparency about energy consumption and energy costs at all measurement levels. In addition, critical deviations in power quality as well as residual currents (RCM), which load or even systems at risk, can be detected. Future-proof investment: the measuring points can be subsequently extended to up to 92 measurement channels thanks
to easily integrated current measuring modules. +49 6441 9642-0 (Phone)info@janitza.de News Downloads Company Energy and power quality measurement products ▼ Scroll to page 2 of 104 advertisement Thank you for your participation! * Your assessment is very important for improving the workof artificial intelligence, which forms the content
of this project 1912/1912773-umg511.pdf file (10 Nov 2022) Read janitza UMG 511 PDF Manual Online: Accompanying Data: janitza UMG 511 Measuring Instruments PDF Installation And Commissioning Manual (Updated: Thursday 10th of November 2022 03:32:19 AM) Rating: 4.4 (rated by 14 users) Compatible devices: MRG 512 PQ Flex, UMG
503, MRG 96RM-E Flex RCM, UMG 103-CBM, UMG 509, UMG 96 RM-P, UMG 512, UMG 801. Recommended Documentation: (Ocr-Read Version Summary of Contents, UPD: 10 November 2022) 27, 27 Measurement voltages and measure- ment currents must come from the same network. m Frequency measurement The UMG511 needs the network
frequency to measure and calculate measurement values. The network frequency must be in a range be- tween 15Hz and 440Hz. For automatic ascertainment (wide range) of the frequency, an L-N voltage large… 56, 56 Frequency measurement The UMG511 needs the network frequency to measure. The network frequency can be spec- ified by the
user or automatically determined by the device. • For automatic ascertainment of the fre- quency using the UMG511, an L-N volt- age larger than 10Veff must be applied to at least one of the voltage measureme… 34, UMG 511 34 Installation Shielding A twisted, shielded cable is foreseen for con- nections through the RS485 interface. • Earth the
shields on all cables, that lead into the cabinet, at the cabinet inlet. • Connect the shield extensively and with good conductivity with a low voltage exter- nal earth. • Intercept the cable mechanically above the earth clamp in order to avoid d… 53, 53 Password With the password, the user can block access to the "settings". It is then only possible to
change the settings directly on the device by entering the password.
A password (000000) is not programmed in the factory. The password consists of a 6 digit number combination. Setting range: 1-999999 = with password 000000 = without… 33, 33 Installation Connection of bus cables The incoming bus cable is connected to clamps 1A and 1B. The bus cable for the next device in the line is connected to clamps 2A
and 2B. If no device follows in the line, the bus cable must be terminated with resistors (switch to ON). In the ON switch position, the clamps 2A and 2B are switched off for… 37, 37 Installation Fig. connection example; UMG511 and PC re- quire a fixed IP address. Fig. connection example; UMG511 and PC re- ceive the IP address automatically
allocated by a DHCP server. DHCP Server Switch PC UMG511 Patch cable PC UMG511 Patch cable Switch Fig. connection example; direct connection between UMG511 and PC using a twisted patch cable (art. no 08.01.505)… 22, 22 Installation Fig. measurement using 3 voltage converters in a three-phase 4 conductor network with asymmetrical
load. Main measurement, inputs 1-3 Fig. measurement in a three-phase 4 conduc- tor network with asymmetrical load. Fig. measurement using 2 voltage converters in a three-phase 4 conductor network with asymmetrical load. Fig. measurement using a three-… 31, 31 Direct measurement Nominal currents up to 5A can also be directly measured
with the UMG511. Please pay at- tention to the fact that each current measure- ment input may be permanently loaded with 6A or with a maximum of 60A for 1 second. Due to the fact that the UMG511 does not have integrated protection for the current measurement, this protection… 7, 7 Art. no. Designation 13 10 539 Profibus plug, 9-pin DSUB,
with integrated switchable terminating resistors.
29 01 903 Sealing, 144x144. 1) Article number - see delivery note Goods-in check Scope of supply Available accessories Number Art. no. Designation 1 52 19 xxx 1) UMG511 1 33 03 089 Installation and commissioning instructions. 1 51 00 116 … 21, UMG 511 21 Installation When connecting the voltage measurement, the following must be observed:
• In order to disconnect the voltage and cur- rent, a suitable circuit breaker is to be pro- vided. • The circuit breaker must be positioned near to the UMG511, identified for the user and easy to reach. • Only use authorised UL/IEC excess current prote… 67, UMG 511 67 Technical data 8 digital inputs Maximum counting frequency : 20Hz Reaction
time (Jasic programme) : 200ms Input signal is applied : 18V .. 28V DC (typical 4mA) Input signal is not applied : 0 ..
5V DC, current lower than 0.5mA 5 digital outputs, semi conductor relay, not short-circuited. Switching voltage : max. 60V DC, 30V AC Switching current : ma… 46, 46 Relevant voltage Depending on the application, the voltage be- tween the external cables (L) or the voltage between the external cables (L) and neutral wire (N) is relevant for analysis
of the network quality. The setting "L-N" is recommended for meas- urement of the network quality in low voltage networks.
You should select the setting &qu… 14, 14 Assembly Place of installation The UMG511 is suitable for installation in sta- tionary and weather-protected control panels. Conductive control panels must be earthed. Installation position In order to achieve sufficient ventilation, the UMG511 must be installed vertically. The clearance at the top and bottom
must be at least 50mm and 20mm at the sides. Beneath the dev… janitza UMG 511 User Manual janitza UMG 511 User Guide janitza UMG 511 PDF Manual janitza UMG 511 Owner's Manuals DOC-a0850b48: Powershot SD430, BDL4221M, EB-1720, SNP-3371TH PCB Piezotronics Model 3503A112KG TRIAXIAL HIGH AMPLITUDE MEMS SHOCK
ACCELEROMETER Installation and Operating Manual For assistance with the operation of this product,contact the PCB Piezotronics, Inc. Toll-free: 716-684-000124-hour SensorLine: 716-684-0001Fax: 716-684-0987E-mail: [email protected]: www.pcb.com ... 3503A112KG 11 WARRANTY:This instrument is warranted from all defects in materials and
manufacturing fora period of two years from the date of purchase.If during this period, the repair or replacement of parts is required, where thedamage is not due to negligence or erroneous operation by the user, please returnthe parts to either dealer or our ofce and the repair wi ... MW14 2 WFM720UP, WFM820UP, and WFM830UP Upgradesfor
the WFM7200, WFM8200, and WFM8300Waveform MonitorsZZZInstructionsxxWarningThe servicing instructions are for use by qualified personnelonly. To avoid personal injury, do not perform any servicingunless you are qualified to do so. Refer to all safety summariesprior to performing service.www.te ktronix.com*P075100103*075-1001-03 ...
WFM720UP 33 Operator's ManualRDO®PRO-X Process Optical Dissolved Oxygen ProbeInformation subject to change without notice. In-Situ, In-Situ logo, Baro Merge, BaroTROLL, HERMIT, HydroVu™, iSitu, Pocket-Situ, RDO,RuggedCable, RuggedReader, SmarTROLL™, TROLL, VuSitu, and Win-Situ are trademarks or registered trademarks of In-
Situ Inc.©2008-2015. All rights reserved. This product may be covered by pa ... RDO PRO-X 29 WARNINGStrictly follow the Instructions for Use. The user must fully understand and strictly observe the instructions.
Use the product only for the purposes specified in the Intended use section of this document.!Dräger Polytron 5200/53X0Instructions for Useiwww.norrscope.com ... Polytron 5200 31 Instructions de montage Installation Instructions Instruciones de Montaje CHASSIS COMPLET EQUIPE RFO 144 Livré sans module FRAME EQUIPPED COMPLETE
RFO 144 Delivered without module CHASIS RFO 144 COMPLETAMENTE EQUIPADO Suministrado sin módulos Nous vous conseillons de lire intégralement cette instruction avant de commenc ... RFO 144 15 User Manual• Mode d’emploi• Bedienungshandbuch• Manual d’Uso• Manual de uso• AnvändarhandbokACD-15 Pro &ACD-15 TRMS
ProClamp-on Multimeter Seriesw ww . . co [email protected] ... ACD-15 Pro 117 BD-2100o w n e r ’ s m a n u a l510INS-0006 REV. 01/11W H E N A C C U R A C Y I S T H E P O I N T.®TMW H E N A C C U R A C Y I S T H E P O I N T.®TMFor 65 years Delmhorst Instrumenthas been the leading manufacturerof high quality, US-made moisturemeters
and thermo-hygrometers.Today we offer a wide range of me-ters for applications includingwater damage re ... BD-2100 11 Dwyer Instruments Series TH2-10 Thermo-Hygrometer PenSpecifications - Installation and Operating InstructionsTE-TH2-10DWYER INSTRUMENTS, INC. Phone: 219/879-8000 www.dwyer-inst.comP.O. BOX 373 • MICHIGAN
CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: [email protected]: RH: 0 to 99.99%; Temperature: -4 to 122°F (-20 to 50°C).Accuracy: ±3% @ 25°C/10 to 9 ... TH2-10 series 2 Manual / BedienungsanleitungClub SeriesCS-500RGY / CS-1000RGYCS-500RGY SE / CS-1000RGY SEPlease read this manual carefully prior to product operation!Bitte
lesen Sie diese Bedienungsanleitung vor Inbetriebnahme des Produkts! rev. 06/2012 vsEnglishDeutsch ... Club Series 20 Product Types by janitza: ▼ Scroll to page 2 of 112 advertisement Thank you for your participation! * Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project